Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
Eye Vis (Lond) ; 11(1): 30, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39004731

RESUMO

BACKGROUND: Accurately assessing corneal structural status is challenging when thickness deviates from the average. Polarization-sensitive optical coherence tomography (PS-OCT) measures tissue-specific polarization changes, providing additional contrast for accurate segmentations and aids in phase retardation (PR) measurements. Previous studies have shown PR's effectiveness in identifying sub-clinical keratoconus (KC) in asymmetric cases. Thus, this study aims to assess PR distribution in thick corneas with and without KC. METHODS: In this retrospective and cross-sectional study, 45 thick corneas from 30 Asian-Indian subjects, categorized into healthy (n = 26) and KC (n = 19) groups were analyzed. All eyes underwent standard clinical evaluations, tomographic assessments, and corneal biomechanics measurements. PR and individual layer thicknesses were measured using custom-designed ultrahigh-resolution PS-OCT. PR en-face maps were generated. Individual layer thicknesses and PR analysis was conducted across multiple zones, extending up to 8-10 mm in diameter. All eyes in the study had not undergone interventions, received topical medications, or had previous corneal disease history. RESULTS: Significant differences were found in spherical and cylindrical powers, keratometry, pachymetry, and biomechanical indices (all P < 0.01). Thickness profiles from PS-OCT showed significant differences in the 4-8 mm zones only. Bowman's layer thickness significantly differed only in the central 2 mm zone (P = 0.02). The median PR values showed marginal differences in the central 2 mm zone (P = 0.0565). Additionally, there were significant differences observed in the 2-4 mm and 4-6 mm zones (P = 0.0274 and P = 0.0456, respectively). KC eyes exhibited an atypical PR distribution and corneal thinning, while normal eyes maintained a uniform Bowman's layer thickness and PR maps with larger areas of higher PR. CONCLUSION: The study revealed distinctive PR distribution in thick corneas among healthy and KC groups. Using an ultrahigh-resolution PS-OCT the significance of Bowman's layer thickness in these groups was also emphasized. The study offered potential improvements in clinical diagnostics by enhancing our understanding of corneal structure and its altered function.

2.
Sci Rep ; 14(1): 13450, 2024 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-38862584

RESUMO

This study tested if a high-resolution, multi-modal, multi-scale retinal imaging instrument can provide novel information about structural abnormalities in vivo. The study examined 11 patients with very mild to moderate non-proliferative diabetic retinopathy (NPDR) and 10 healthy subjects using fundus photography, optical coherence tomography (OCT), OCT angiography (OCTA), adaptive optics scanning laser ophthalmoscopy (AO-SLO), adaptive optics OCT and OCTA (AO-OCT(A)). Of 21 eyes of 11 patients, 11 had very mild NPDR, 8 had mild NPDR, 2 had moderate NPDR, and 1 had no retinopathy. Using AO-SLO, capillary looping, inflections and dilations were detected in 8 patients with very mild or mild NPDR, and microaneurysms containing hyperreflective granular elements were visible in 9 patients with mild or moderate NPDR. Most of the abnormalities were seen to be perfused in the corresponding OCTA scans while a few capillary loops appeared to be occluded or perfused at a non-detectable flow rate, possibly because of hypoperfusion. In one patient with moderate NPDR, non-perfused capillaries, also called ghost vessels, were identified by alignment of corresponding en face AO-OCT and AO-OCTA images. The combination of multiple non-invasive imaging methods could identify prominent microscopic abnormalities in diabetic retinopathy earlier and more detailed than conventional fundus imaging devices.


Assuntos
Capilares , Retinopatia Diabética , Oftalmoscopia , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Retinopatia Diabética/diagnóstico por imagem , Retinopatia Diabética/patologia , Feminino , Masculino , Oftalmoscopia/métodos , Pessoa de Meia-Idade , Capilares/diagnóstico por imagem , Capilares/patologia , Adulto , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Idoso , Angiofluoresceinografia/métodos
3.
J Clin Med ; 13(4)2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38398387

RESUMO

Purpose: To assess retinal function in areas of presumed fibrosis due to neovascular age-related macular degeneration (nAMD), using multimodal imaging and structure-function correlation. Design: Cross-sectional observational study. Methods: 30 eyes of 30 consecutive patients with nAMD with a minimum history of one year of anti-vascular endothelial growth factor therapy were included. Each patient underwent microperimetry (MP), color fundus photography (CFP), standard spectral-domain-based OCT (SD-OCT), and polarization sensitive-OCT (PS-OCT) imaging. PS-OCT technology can depict retinal fibrosis based on its birefringence. CFP, SD-OCT, and PS-OCT were evaluated independently for the presence of fibrosis at the corresponding MP stimuli locations. MP results and morphologic findings in CFP, SD-OCT, and PS-OCT were co-registered and analyzed using mixed linear models. Results: In total, 1350 MP locations were evaluated to assess the functional impact of fibrosis according to a standardized protocol. The estimated means of retinal areas with signs of fibrosis were 12.60 db (95% confidence interval: 10.44-14.76) in CFP, 11.60 db (95% COI: 8.84-14.36) in OCT, and 11.02 db (95% COI 8.10-13.94) in PS-OCT. Areas evaluated as subretinal fibrosis in three (7.2 db) or two (10.1 db) modalities were significantly correlated with a lower retinal sensitivity than a subretinal fibrosis observed in only one (15.3 db) or none (23.3 db) modality (p < 0.001). Conclusions: CFP, SD-OCT and PS-OCT are all suited to detect areas of reduced retinal sensitivity related to fibrosis, however, a multimodal imaging approach provides higher accuracy in the identification of areas with low sensitivity in MP (i.e., impaired retinal function), and thereby improves the detection rate of subretinal fibrosis in nAMD.

4.
Biomed Opt Express ; 14(7): 3726-3747, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37497506

RESUMO

Optical coherence tomography (OCT) is the most widely used imaging modality in ophthalmology. There are multiple variations of OCT imaging capable of producing complementary information. Thus, registering these complementary volumes is desirable in order to combine their information. In this work, we propose a novel automated pipeline to register OCT images produced by different devices. This pipeline is based on two steps: a multi-modal 2D en-face registration based on deep learning, and a Z-axis (axial axis) registration based on the retinal layer segmentation. We evaluate our method using data from a Heidelberg Spectralis and an experimental PS-OCT device. The empirical results demonstrated high-quality registrations, with mean errors of approximately 46 µm for the 2D registration and 9.59 µm for the Z-axis registration. These registrations may help in multiple clinical applications such as the validation of layer segmentations among others.

5.
Biomed Opt Express ; 14(6): 2709-2725, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37342719

RESUMO

Using conventional optical coherence tomography (OCT), it is difficult to image Henle fibers (HF) due to their low backscattering potential. However, fibrous structures exhibit form birefringence, which can be exploited to visualize the presence of HF by polarization-sensitive (PS) OCT. We found a slight asymmetry in the retardation pattern of HF in the fovea region that can be associated with the asymmetric decrease of cone density with eccentricity from the fovea. We introduce a new measure based on a PS-OCT assessment of optic axis orientation to estimate the presence of HF at various eccentricities from the fovea in a large cohort of 150 healthy subjects. By comparing a healthy age-matched sub-group (N = 87) to a cohort of 64 early-stage glaucoma patients, we found no significant difference in HF extension but a slightly decreased retardation at about 2° to 7.5° eccentricity from the fovea in the glaucoma patients. This potentially indicates that glaucoma affects this neuronal tissue at an early state.

6.
J Cataract Refract Surg ; 49(1): 76-83, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36026712

RESUMO

PURPOSE: To assess phase retardation and corneal sublayer thickness repeatability using ultrahigh-resolution polarization-sensitive optical coherence tomography (PS-OCT). SETTING: Narayana Nethralaya Eye Hospital, Bangalore. DESIGN: Observational. METHODS: In this study, all eyes were imaged using a custom-built ultrahigh-resolution PS-OCT and high-resolution hybrid OCT (MS-39). The repeatability of phase retardation en face maps and corneal sublayer thickness profiles was evaluated. The reflectivity and phase retardation were calculated from the 2 orthogonal polarization channels to generate en face maps of phase retardation and corneal sublayer thicknesses. 3 consecutive measurements of all participants were acquired for each eye. For each measurement, the participant was asked to sit back and was realigned again. The repeatability was assessed using the intraclass correlation coefficient (ICC). RESULTS: The study included 20 healthy eyes of 20 participants. The phase retardation en face maps showed preferential arrangement of collagen fibrils with least retardation in the apex and maximum retardation in the periphery. The phase retardation showed excellent repeatability (ICC >0.95) in all zones. The Bowman layer and stromal layer thicknesses were measured with excellent repeatability (ICC >0.93 and >0.99, respectively). Significant differences ( P < .05) in stromal layer thickness were observed between MS-39 and PS-OCT. The repeatability of epithelial thickness measurements was better with PS-OCT than MS-39. CONCLUSIONS: The combinational assessment of corneal birefringence and sublayer thicknesses shows the advanced potential of ultrahigh-resolution PS-OCT in routine clinical practice over current OCT devices.


Assuntos
Córnea , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Índia , Refração Ocular , Paquimetria Corneana
7.
PLoS One ; 17(12): e0278679, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36512582

RESUMO

We present measurements of depolarization introduced by the retinal pigment epithelium (RPE) over a 45° field of view using polarization sensitive optical coherence tomography. A detailed spatial distribution analysis of depolarization caused by the RPE is presented in a total of 153 subjects including both healthy and diseased eyes. Age and sex related differences in the depolarizing character of the RPE are investigated.


Assuntos
Glaucoma , Epitélio Pigmentado da Retina , Humanos , Epitélio Pigmentado da Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Refração Ocular , Nível de Saúde , Angiofluoresceinografia/métodos
8.
Invest Ophthalmol Vis Sci ; 63(12): 8, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36331260

RESUMO

Purpose: To study the circumpapillary retinal nerve fiber layer (RNFL) birefringence (BIR) of early glaucoma and age-matched healthy eyes using polarization-sensitive optical coherence tomography (PS-OCT). Methods: In this prospective cross-sectional study, we compared virtual circular PS-OCT B-scans with a diameter of 3.5 mm centered on the optic disc (OD) acquired with a PS-OCT prototype (860 nm center wavelength). Early glaucoma was defined by the glaucomatous appearance of the OD and a pathologic visual field test with a mean deviation (MD) better than -6 dB. The main outcome parameters were BIR, RNFL-thickness (RNFL-T), and phase retardation (RET). The BIR value at each virtual A-scan position was the quotient of the RET measured at the inner segment/outer segment junction divided by the RNFL-T. Results: The dataset comprised 49 early glaucoma patients (mean ± standard deviation [SD]: 64 ± 10 years) and 49 healthy control subjects (61 ± 9 years). Glaucomatous eyes showed a statistically significant lower BIR globally (mean ± SD: 0.108 ± 0.008°/µm vs. 0.112 ± 0.009°/µm, P = 0.033), superiorly (0.116 ± 0.017°/µm vs. 0.126 ± 0.013°/µm, P = 0.0001), and inferiorly (0.112 ± 0.011°/µm vs. 0.121 ± 0.011°/µm, P < 0.0001), and increased BIR in the temporal quadrant (0.088 ± 0.015°/µm vs. 0.078 ± 0.014°/µm, P = 0.0001) compared to healthy eyes. Conclusions: We report a reduced BIR of the RNFL in early perimetric glaucoma, which can be interpreted as a sign of loss or change of intracellular microtubules and may contribute to a better understanding of early disease development. Prospective longitudinal studies are needed to determine whether BIR is altered in pre-perimetric human glaucoma before RNFL-T decline.


Assuntos
Glaucoma , Fibras Nervosas , Humanos , Fibras Nervosas/patologia , Tomografia de Coerência Óptica/métodos , Células Ganglionares da Retina/patologia , Birrefringência , Campos Visuais , Estudos Transversais , Estudos Prospectivos , Glaucoma/diagnóstico , Glaucoma/patologia , Pressão Intraocular
9.
Sci Rep ; 12(1): 9577, 2022 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-35688890

RESUMO

We present a compact multi-modal and multi-scale retinal imaging instrument with an angiographic functional extension for clinical use. The system integrates scanning laser ophthalmoscopy (SLO), optical coherence tomography (OCT) and OCT angiography (OCTA) imaging modalities and provides multi-scale fields of view. For high resolution, and high lateral resolution in particular, cellular imaging correction of aberrations by adaptive optics (AO) is employed. The entire instrument has a compact design and the scanning head is mounted on motorized translation stages that enable 3D self-alignment with respect to the subject's eye by tracking the pupil position. Retinal tracking, based on the information provided by SLO, is incorporated in the instrument to compensate for retinal motion during OCT imaging. The imaging capabilities of the multi-modal and multi-scale instrument were tested by imaging healthy volunteers and patients.


Assuntos
Pupila , Retina , Humanos , Oftalmoscopia/métodos , Óptica e Fotônica , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos
10.
Biomed Opt Express ; 13(1): 65-81, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35154854

RESUMO

A technique to accurately estimate trajectories of retinal nerve fiber bundles (RNFB) in a large field of view (FOV) image covering 45° is described. The method utilizes stitched projections of polarization-sensitive optical coherence tomography (PS-OCT) data, as well as a mathematical model of average RNFB trajectories as prior. The fully automatic process was applied to data recorded in healthy subjects and glaucoma patients and automatically detected individual RNFB trajectories are compared to manual traces.

11.
Sci Rep ; 12(1): 88, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34996934

RESUMO

To find baseline predictors for subretinal fibrosis (SF) in neovascular age-related macular degeneration (nAMD). Forty-five eyes of 45 participants with treatment-naïve nAMD were consecutively enrolled and treated according to a standardized treat-and-extend protocol. Spectral-domain optical coherence tomography (OCT), color fundus photography and fluorescein angiography as well as novel imaging modalities polarization-sensitive OCT and OCT angiography (OCTA) were performed to detect SF after 1 year and find baseline predictors for SF development. Baseline OCTA scans were evaluated for quantitative features such as lesion area, vessel area, vessel junctions, vessel length, vessel endpoints and mean lacunarity. Additionally, the type of macular neovascularization, the presence of subretinal fluid, intraretinal fluid (IRF), subretinal hyperreflective material (SHRM), retinal hemorrhage as well as best-corrected visual acuity (BCVA) were evaluated. After 12 months 8 eyes (18%) developed SF. Eyes with SF had worse baseline BCVA (p = .001) and a higher prevalence of IRF (p = .014) and SHRM at baseline (p = .017). There was no significant difference in any of the evaluated quantitative OCTA parameters (p > .05) between eyes with and without SF. There were no quantitative baseline microvascular predictors for SF in our study. Low baseline BCVA, the presence of IRF and SHRM, however, are easily identifiable baseline parameters indicating increased risk.


Assuntos
Angiofluoresceinografia , Degeneração Macular/diagnóstico por imagem , Fotografação , Retina/diagnóstico por imagem , Neovascularização Retiniana/diagnóstico por imagem , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Inibidores da Angiogênese/uso terapêutico , Feminino , Fibrose , Humanos , Estudos Longitudinais , Degeneração Macular/tratamento farmacológico , Degeneração Macular/patologia , Degeneração Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Retina/efeitos dos fármacos , Retina/patologia , Retina/fisiopatologia , Neovascularização Retiniana/tratamento farmacológico , Neovascularização Retiniana/patologia , Neovascularização Retiniana/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual
12.
J Cataract Refract Surg ; 48(8): 929-936, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35082233

RESUMO

PURPOSE: To evaluate phase retardation (PR) across healthy eyes and eyes with thin corneas (<500 µm) and with asymmetric and bilateral keratoconus (KC). SETTING: Narayana Nethralaya Eye Hospital, Bangalore, India. DESIGN: Observational cross-sectional. METHODS: There were 4 eye groups: healthy eyes (Group 1; n = 10 eyes), eyes with thin corneas and no clinical disease (Group 2; n = 10 eyes), eyes with asymmetric KC (Group 3; n = 5 eyes), and eyes with clinical KC (Group 4; n = 15 eyes). All eyes were imaged with polarization-sensitive optical coherence tomography (PS-OCT), MS-39, and Corvis-ST. Using PS-OCT, PR was analyzed in annular regions. The anterior (A-E) and Bowman (E-B) wavefront aberrations, epithelial Zernike indices (EZI), total corneal thickness, Corvis biomechanical index (CBI), total biomechanical index (TBI), and Belin-Ambrósio overall deviation index (BAD-D) were analyzed. RESULTS: Only CBI, TBI, BAD-D, A-E and E-B aberrations, EZI, and total corneal thickness distributions of Groups 1 (n =10), 2 (n =10), and 3 (n =5) were similar ( P > .05) but not CCT ( P < .05). PR distributions clearly showed that the eyes in Groups 1, 2, and 3 had a normal corneal birefringence unlike Group 4 (n = 10) eyes ( P < .05). The PR map was similar to the preferred orientations of collagen fibers seen in X-ray diffraction ex vivo studies of corneal stroma. CONCLUSIONS: PR distributions may eliminate the uncertainty associated with the stromal status of thin and asymmetric KC corneas. Group 2 and 3 eyes appeared as healthy because of normal corneal birefringence at the time of imaging, but a longitudinal follow-up of these eyes with PS-OCT may assist in early detection of onset of disease.


Assuntos
Ceratocone , Birrefringência , Córnea , Topografia da Córnea/métodos , Estudos Transversais , Humanos , Índia , Ceratocone/diagnóstico , Curva ROC , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos
13.
Transl Vis Sci Technol ; 10(14): 1, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34851359

RESUMO

Purpose: To evaluate morphologic and microvascular differences between eyes with and without subretinal fibrosis (SF) caused by neovascular age-related macular degeneration (nAMD). Methods: Patients with nAMD with a minimum history of 12 months of anti-VEGF treatment were prospectively included in this cross-sectional study. Patients were imaged using standard imaging, swept-source optical coherence tomography angiography for quantitative microvascular analysis and polarization-sensitive OCT as an ancillary method for automated SF segmentation. The presence of reticular pseudodrusen, hyperreflective foci (HRF), and outer retinal tubulation (ORT) were also evaluated. Results: Sixty eyes of 60 participants (37 female) with nAMD and a mean 3.1 (±2.7)-year history of anti-VEGF treatment were included, 20 (33%) of which were diagnosed with SF. Eyes with SF had a higher prevalence of ORT (P < 0.001) and a lower prevalence of HRF (P = 0.004) than eyes without SF. Fifty eyes were analyzed quantitatively for microvascular biomarkers. Eyes with SF had a larger greatest vascular caliber (P = 0.001) and greatest linear diameter (P = 0.042), a larger microvascular neovascularization (MNV) area (P = 0.026), larger vessel area (P = 0.037), higher number of vessel junctions (P = 0.025), longer total vessel length (P = 0.027), higher number of vessel endpoints (P = 0.007), and higher endpoint density (P = 0.047). Conclusions: This multimodal imaging approach demonstrated in vivo microvascular and morphological differences in eyes with and without SF. Eyes with SF tend to have larger MNV lesions with thicker vessels and are often associated with the presence of ORT. Translational Relevance: This study points out imaging biomarkers in patients with SF, which may help identifying high-risk patients.


Assuntos
Neovascularização de Coroide , Tomografia de Coerência Óptica , Estudos Transversais , Feminino , Fibrose , Angiofluoresceinografia , Humanos , Acuidade Visual
14.
Biomed Opt Express ; 12(11): 7092-7112, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34858702

RESUMO

We demonstrate the use of temporal phase evolution (TPE-) OCT methods to evaluate retinal tissue deformation in-vivo over time periods of several seconds. A custom built spectral domain (SD)-OCT system with an integrated retinal tracker, ensuring stable imaging with sub-speckle precision, was used for imaging. TPE-OCT measures and images phase differences between an initial reference B-scan and each of the subsequent B-scans of the evaluated temporal sequence. In order to demonstrate the precision and repeatability of the measurements, retinal nerve fiber (RNF) tissue deformations induced by retinal vessels pulsating with the heartbeat were analyzed in several healthy subjects. We show TPE maps (M-scans of phase evolution as a function of position along B-scan trace vs. time) of wrapped phase data and corresponding deformation maps in selected regions of the RNF layer (RNFL) over the course of several cardiac cycles. A reproducible phase pattern is seen at each heartbeat cycle for all imaged volunteers. RNF tissue deformations near arteries and veins up to ∼ 1.6 µm were obtained with an average precision for a single pixel of about 30 nm. Differences of motion induced by arteries and veins are also investigated.

15.
Biomed Opt Express ; 12(10): 5969-5990, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34745716

RESUMO

The pyramid wavefront sensor (P-WFS) has replaced the Shack-Hartmann (SH-) WFS as the sensor of choice for high-performance adaptive optics (AO) systems in astronomy. Many advantages of the P-WFS, such as its adjustable pupil sampling and superior sensitivity, are potentially of great benefit for AO-supported imaging in ophthalmology as well. However, so far no high quality ophthalmic AO imaging was achieved using this novel sensor. Usually, a P-WFS requires modulation and high precision optics that lead to high complexity and costs of the sensor. These factors limit the competitiveness of the P-WFS with respect to other WFS devices for AO correction in visual science. Here, we present a cost-effective realization of AO correction with a non-modulated P-WFS based on standard components and apply this technique to human retinal in vivo imaging using optical coherence tomography (OCT). P-WFS based high quality AO imaging was successfully performed in 5 healthy subjects and smallest retinal cells such as central foveal cone photoreceptors are visualized. The robustness and versatility of the sensor is demonstrated in the model eye under various conditions and in vivo by high-resolution imaging of other structures in the retina using standard and extended fields of view. As a quality benchmark, the performance of conventional SH-WFS based AO was used and successfully met. This work may trigger a paradigm shift with respect to the wavefront sensor of choice for AO in ophthalmic imaging.

16.
Invest Ophthalmol Vis Sci ; 62(13): 1, 2021 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-34605880

RESUMO

Purpose: The purpose of this study was to assess density and morphology of cone photoreceptors (PRs) and corresponding retinal sensitivity in ischemic compared to nonischemic retinal capillary areas of diabetic eyes using adaptive optics optical coherence tomography (AO-OCT) and microperimetry (MP). Methods: In this cross-sectional, observational study five eyes of four patients (2 eyes with proliferative diabetic retinopathy (DR) and 3 eyes moderate nonproliferative DR) were included. PR morphology and density was manually assessed in AO-OCT en face images both at the axial position of the inner-segment outer segment (IS/OS) and cone outer segment tips (COSTs). Retinal sensitivity was determined by fundus-controlled microperimetry in corresponding areas (MP-3, Nidek). Results: In AO-OCT, areas affected by capillary nonperfusion showed severe alterations of cone PR morphology at IS/OS and COST compared to areas with intact capillary perfusion (84% and 87% vs. 9% and 8% of area affected for IS/OS and COST, respectively). Mean reduction of PR signal density in affected areas compared to those with intact superficial capillary plexus (SCP) and deep capillary plexus (DCP) perfusion of similar eccentricity was -38% at the level of IS/OS (P = 0.01) and -39% at the level of COST (P = 0.01). Mean retinal sensitivity was 10.8 ± 5.4 in areas affected by DCP nonperfusion and 28.2 ± 1.5 outside these areas (P < 0.001). Conclusions: Cone PR morphology and signal density are severely altered in areas of capillary nonperfusion. These structural changes are accompanied by a severe reduction of retinal sensitivity, indicating the importance of preventing impaired capillary circulation in patients with DR.


Assuntos
Retinopatia Diabética/diagnóstico , Isquemia/diagnóstico , Células Fotorreceptoras Retinianas Cones/patologia , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Testes de Campo Visual/métodos , Adulto , Capilares/patologia , Estudos Transversais , Retinopatia Diabética/complicações , Retinopatia Diabética/fisiopatologia , Feminino , Humanos , Isquemia/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
17.
Biomed Opt Express ; 12(7): 4380-4400, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34457420

RESUMO

Subretinal fibrosis is one of the most prevalent causes of blindness in the elderly population, but a true gold standard to objectively diagnose fibrosis is still lacking. Since fibrotic tissue is birefringent, it can be detected by polarization-sensitive optical coherence tomography (PS-OCT). We present a new algorithm to automatically detect, segment, and quantify fibrotic lesions within 3D data sets recorded by PS-OCT. The algorithm first compensates for the birefringence of anterior ocular tissues and then uses the uniformity of the birefringent optic axis as an indicator to identify fibrotic tissue, which is then segmented and quantified. The algorithm was applied to 3D volumes recorded in 57 eyes of 57 patients with neovascular age-related macular degeneration using a spectral domain PS-OCT system. The results of fibrosis detection were compared to the clinical diagnosis based on color fundus photography (CFP), and the precision of fibrotic area measurement was assessed by three repeated measurements in a sub-set of 15 eyes. The average standard deviation of the fibrotic area obtained in eyes with a lesion area > 0.7 mm2 was 15%. Fibrosis detection by CFP and PS-OCT agreed in 48 cases, discrepancies were only observed in cases of lesion area < 0.7 mm2. These remaining discrepancies are discussed, and a new method to treat ambiguous cases is presented.

18.
Invest Ophthalmol Vis Sci ; 62(4): 24, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33871570

RESUMO

Purpose: To study birefringence of the peripapillary retinal nerve fiber layer (RNFL) of diabetic eyes with no clinical signs of diabetic retinopathy (DR) or mild to moderate DR stages using spectral-domain polarization-sensitive (PS) optical coherence tomography (OCT). Methods: In this observational pilot study, circular PS-OCT scans centered on the optic nerve head were recorded in prospectively recruited diabetic and age-matched healthy eyes. From averaged circumpapillary intensity and retardation tomograms plots of RNFL birefringence were obtained by a linear fit of retardation versus depth within the RNFL tissue for each A-scan position and mean birefringence values for RNFL calculated. Spectral-domain OCT imaging (Heidelberg Engineering) was performed to assess peripapillary RNFL thickness and macular ganglion cell complex (GCC). Results: Out of 70 eyes of 43 diabetic patients (mean ± SD age: 50.86 ± 15.71) 36 showed no signs of DR, 17 mild and 17 moderate nonproliferative DR with no diabetic macular edema. Thirty-four eyes of 34 healthy subjects (53.21 ± 13.88 years) served as controls. Compared with healthy controls (0.143° ± 0.014°/µm) mean total birefringence of peripapillary RNFL was significantly reduced in subclinical diabetic eyes (0.131° ± 0.014°/µm; P = 0.0033), as well as in mild to moderate DR stages (0.125° ± 0.018°/µm, P < 0.0001) with borderline statistically significant differences between diabetic patients (P = 0.0049). Mean birefringence values were significantly lower in inferior compared with superior RNFL sectors (P < 0.0001) of diabetic eyes with no such difference detected in the healthy control group. Conclusions: We identified evidence of early neuroretinal alteration in diabetic eyes through reduced peripapillary RNFL birefringence assessed by PS-OCT occurring before appearance of clinical microvascular lesions or GCC alterations.


Assuntos
Retinopatia Diabética/diagnóstico , Fibras Nervosas/patologia , Disco Óptico/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Birrefringência , Retinopatia Diabética/fisiopatologia , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Fatores de Tempo
19.
PLoS One ; 16(1): e0245293, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33412568

RESUMO

PURPOSE: To assess the signal composition of cone photoreceptors three-dimensionally in healthy retinas using adaptive optics optical coherence tomography (AO-OCT). METHODS: Study population. Twenty healthy eyes of ten subjects (age 23 to 67). Procedures. After routine ophthalmological assessments, eyes were examined using AO-OCT. Three-dimensional volumes were acquired at 2.5° and 6.5° foveal eccentricity in four main meridians (superior, nasal, inferior, temporal). Cone densities and signal compositions were investigated in four different planes: the cone inner segment outer segment junction (IS/OS), the cone outer segment combined with the IS/OS (ISOS+), the cone outer segment tips (COST) and full en-face plane (FEF) combining signals from all mentioned cone layers. Additionally, reliability of a simple semi-automated approach for assessment of cone density was tested. Main outcome measures. Cone density of IS/OS, IS/OS+, COST and FEF. Qualitative depiction and composition of each cone layer. Inter-rater agreement of cone density measurements. RESULTS: Mean overall cone density at all eccentricities was highest at the FEF plane (21.160/mm2), followed by COST (20.450/mm2), IS/OS+ (19.920/mm2) and IS/OS (19.530/mm2). The different meridians and eccentricities had a significant impact on cone density, with lower eccentricity resulting in higher cone densities (p≤.001), which were highest at the nasal, then temporal, then inferior and then superior meridian. Depiction of the cone mosaic differed between all 4 layers regarding signal size and packing density. Therefore, different cone layers showed evident but not complete signal overlap. Using the semi-automated technique for counting of cone signals achieved high inter-rater reliability (ICC > .99). CONCLUSIONS: In healthy individuals qualitative and quantitative changes in cone signals are found not only in different eccentricities and meridians, but also within different photoreceptor layers. The variation between cone planes has to be considered when assessing the integrity of cone photoreceptors in healthy and diseased eyes using adaptive optics technology.


Assuntos
Imageamento Tridimensional/métodos , Células Fotorreceptoras Retinianas Cones/citologia , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Feminino , Humanos , Imageamento Tridimensional/normas , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/normas
20.
Opt Express ; 28(24): 36723-36739, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33379760

RESUMO

An adaptive optics optical coherence tomography (AO-OCT) system is used to assess sixty healthy eyes of thirty subjects (age 22 to 75) to evaluate how the outer retinal layers, foveal eccentricity and age effect the mean cone density. The cone mosaics of different retinal planes (the cone inner segment outer segment junction (IS/OS), the cone outer segment combined with the IS/OS (ISOS+), the cone outer segment tips (COST), and the full en-face plane (FEF)) at four main meridians (superior, nasal, inferior, temporal) and para- and perifoveal eccentricities (ecc 2.5° and 6.5°) were analyzed quantitatively. The mean overall cone density was 19,892/mm2 at ecc 2.5° and 13,323/mm2 at ecc 6.5°. A significant impact on cone density was found for eccentricity (up to 6,700/mm2 between ecc 2.5° and 6.5°), meridian (up to 3,700/mm2 between nasal and superior meridian) and layer (up to 1,400/mm2 between FEF and IS/OS). Age showed only a weak negative effect. These factors as well as inter-individual variability have to be taken into account when comparing cone density measurements between healthy and pathologically changed eyes, as their combined effect on density can easily exceed several thousand cones per mm2 even in parafoveal regions.


Assuntos
Envelhecimento/fisiologia , Fóvea Central/diagnóstico por imagem , Imageamento Tridimensional/métodos , Células Fotorreceptoras Retinianas Cones/citologia , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Contagem de Células , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Estudos Prospectivos , Acuidade Visual/fisiologia , Campos Visuais/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...