Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
BMJ Open ; 14(6): e085723, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890135

RESUMO

BACKGROUND: Despite research into how to effectively implement evidence-based recommendations into clinical practice, a lack of standardisation in the commissioning and development of clinical practice guidelines can lead to inconsistencies and gaps in implementation. This research aimed to ascertain how topics in kidney care worthy of guideline development within the UK should be chosen, prioritised, designed and implemented. METHODS: Following a modified Delphi methodology, a multi-disciplinary panel of experts in kidney healthcare from across the UK developed 35 statements on the issues surrounding the selection, development and implementation of nephrology guidelines. Consensus with these statements was determined by agreement using an online survey; the consensus threshold was defined as 75% agreement. RESULTS: 419 responses were received. Of the 364 healthcare practitioners (HCPs), the majority had over 20 years of experience in their role (n=123) and most respondents were nephrologists (n=95). Of the 55 non-clinical respondents, the majority were people with kidney disease (n=41) and the rest were their carers or family. Participants were from across England, Northern Ireland, Scotland and Wales. Consensus between HCPs was achieved in 32/35 statements, with 28 statements reaching ≥90% agreement. Consensus between patients and patient representatives was achieved across all 20 statements, with 13/20 reaching ≥90% agreement. CONCLUSIONS: The current results have provided the basis for six recommendations to improve the selection, design and implementation of guidelines. Actioning these recommendations will help improve the accessibility of, and engagement with, clinical guidelines, contributing to the continuing development of best practice in UK kidney care.


Assuntos
Consenso , Técnica Delphi , Guias de Prática Clínica como Assunto , Humanos , Reino Unido , Nefrologia/normas , Inquéritos e Questionários , Nefropatias/terapia
2.
Prehosp Disaster Med ; 27(5): 458-62, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22874523

RESUMO

BACKGROUND: Event planning for mass gatherings involves the utilization of methods that prospectively can predict medical resource use. However, there is growing recognition that historical data for a specific event can help to accurately forecast medical requirements. This study was designed to investigate the differences in medical usage rates between two popular mass-gathering sports events in the UK: rugby matches and horse races. METHODS: A retrospective study of all attendee consultations with the on-site medical teams at the Leicester Tigers Rugby Football Club and the Leicester Racecourse from September 2008 through August 2009 was undertaken. Patient demographics, medical usage rates, level of care, as well as professional input and the effects of alcohol use were recorded. RESULTS: Medical usage rates were higher at the Leicester Racecourse (P < .01), although the demographics of the patients were similar and included 24% children and 16% staff. There was no difference in level of care required between the two venues with the majority of cases being minor, although a higher proportion of casualties at the Leicester Tigers event were seen by a health care professional compared with the Leicester Racecourse (P < .001). Alcohol was a contributing factor in only 5% of consultations. CONCLUSIONS: These two major sporting venues had similar attendance requirements for medical treatment that are comparable to other mass-gathering sports events. High levels of staff and pediatric presentations may have an impact on human resource planning for events on a larger scale, and the separation of treatment areas may help to minimize the number of unnecessary or opportunistic reviews by the on-site health care professionals.


Assuntos
Serviços Médicos de Emergência/estatística & dados numéricos , Primeiros Socorros/estatística & dados numéricos , Esportes/classificação , Adolescente , Adulto , Animais , Aniversários e Eventos Especiais , Criança , Serviços Médicos de Emergência/organização & administração , Feminino , Futebol Americano , Previsões/métodos , Cavalos , Humanos , Masculino , Comportamento de Massa , Técnicas de Planejamento , Estudos Retrospectivos , Esportes/estatística & dados numéricos , Reino Unido
3.
Hemodial Int ; 13(3): 293-300, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19469884

RESUMO

Dialysis-induced hypotension remains a significant problem in hemodialysis (HD) patients. Numerous factors result in dysregulation of blood pressure control and impaired myocardial reserve in response to HD-induced cardiovascular stress. Episodic intradialytic hypotension may be involved in the pathogenesis of evolving myocardial injury. We performed an initial pilot investigation of cardiovascular functional response to pharmacological cardiovascular stress in hypotension-resistant (HR) and hypotension-prone (HP) HD patients. We studied 10 matched chronic HD patients (5 HP, 5 HR). Dobutamine-atropine stress (DAS) was performed on a nondialysis short interval day, with noninvasive pulse-wave analysis using the Finometer to continuously measure hemodynamic variables. Baroreflex sensitivity was assessed at rest and during DAS. Baseline hemodynamic variables were not significantly different. The groups had differing hemodynamic responses to DAS. The Mean arterial pressure was unchanged in the HR group but decreased in HP patients (-13.6 +/- 3.5 mmHg; P<0.001). This was associated with failure to significantly increase cardiac output in the HP group (cf. increase in cardiac output in the HR group of +33.4 +/- 6%; P<0.05), and a reduced response in total peripheral resistance (HP -10.3 +/- 6.8%, HR -22.7 +/- 2.9%, P=NS). Baroreflex sensitivity was not significantly different between groups at baseline or within groups with increasing levels of DAS; however, the mean baroreflex sensitivity was higher in HR cf. HP subjects throughout pharmacological stress (P<0.05). Hypotension-prone patients appear to have an impaired cardiovascular response to DAS. The most significant abnormality is an impaired myocardial contractile reserve. Early identification of these patients would allow utilization of therapeutic strategies to improve intradialytic tolerability, potentially abrogating aggravation of myocardial injury.


Assuntos
Hipotensão/fisiopatologia , Contração Miocárdica/fisiologia , Diálise Renal/efeitos adversos , Adulto , Idoso , Atropina , Pressão Sanguínea/efeitos dos fármacos , Dobutamina , Eletrocardiografia/métodos , Feminino , Humanos , Hipotensão/sangue , Hipotensão/etiologia , Masculino , Pessoa de Meia-Idade
4.
Hemodial Int ; 10(4): 346-50, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17014509

RESUMO

Considerable intrinsic intrapatient variability influences the actual delivery of Kt/V. The aim of this study is to examine the feasibility of using continuous online assessment of ionic dialysance measurements (Kt/V(ID)) to allow dialysis sessions to be altered on an individual basis. Ten well-established chronic hemodialysis (HD) patients without significant residual renal function were studied (mean age 65+/-4.3 [38-81] years, mean length of time on dialysis 66+/-18 [14-189] months). These patients had all been receiving thrice-weekly 4-hr dialysis using Integra dialysis monitors. Dialysis monitors were equipped with Diascan modules permitting measurement of Kt/V(ID). Predicted treatment time required to achieve a Kt/V(ID) > or = 1.1 (equivalent to a urea-based method of 1.2) was calculated from the delivered Kt/V(ID) at 60 and 120 min. Treatment time was reprogrammed at 2 hr (ensuring all planned ultrafiltration would be accommodated into the new modified session duration). Owing to practical issues, and to avoid excessively short dialysis times, these changes were censored at no more than+/-10% of the usual 240-min treatment time (210-265 min). Data were collected from a total of 50 dialysis sessions. Almost all sessions (47/50) required modification of the standard treatment time: 13/50 sessions were lengthened and 34/50 shortened (mean length of session 232.2+/-2.5 [210-265] min). A Kt/V(ID) of > or = 1.1 was achieved in 39/50 sessions. The difference in mean urea-based Kt/V poststudy (1.3+/-0.05 [1.1-1.6]) and mean achieved Kt/V(ID) (1.16+/-0.02 [0.7-1.37]) was significant (p = 0.002). The use of individualized variable dialysis treatment time using online ionic dialysance measurements of Kt/V(ID) appears both practicable and effective at ensuring consistently delivered adequate dialysis.


Assuntos
Soluções para Hemodiálise/química , Diálise Renal/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Íons/análise , Pessoa de Meia-Idade , Monitorização Fisiológica , Sistemas On-Line , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...