Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Malar J ; 19(1): 288, 2020 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-32787959

RESUMO

BACKGROUND: Malaria rapid diagnostic tests (RDTs) are largely responsible for the gains made in the proportion of malaria cases confirmed with a parasitological test. However, quality assurance programs to support their use remain a challenge. A dried tube specimen (DTS) method was developed that showed potential for use as a stable source of quality control (QC) sample for RDTs and for use in external quality assessments or proficiency testing (PT). DTS was further assessed with focus on sample stability under field settings in Benin and Liberia. METHODS: DTS were prepared using Plasmodium falciparum 3D7 or W2 strains at concentrations of 1000, 500 or 0 parasites/µL and tested for baseline reactivity at the Centers for Disease Control and Prevention, Atlanta before shipping. In Benin and Liberia, DTS were stored under refrigeration in a reference laboratory (RL) or in health centres under ambient temperatures. Seven rounds of testing were performed at 4-week intervals during which DTS were tested on RDTs stored at the RL or at health centres. Observed DTS reactivity at the RL and health centres were compared to expected reactivity to determine DTS stability. DTS were also assembled into a PT panel and tested by health facility staff at the mid and end time-points of the study. Daily maximum and minimum storage temperatures for RDTs and DTS were recorded. RESULTS: In Benin, DTS, irrespective of storage conditions, produced the expected reactivity at all time points. However, evidence of degradation was observed at weeks 20 and 24 for DTS stored at ambient temperatures at the health centres and not those stored under refrigeration at the RL. In Liberia, sample degradation was observed starting at week 8 especially among DTS stored at the health facilities. The degradation was associated with prolonged storage of DTS under ambient temperature prior to study commencement and less than optimal storage temperatures at the RL. Use of DTS in a PT enabled identification of health worker errors in performing the tests. CONCLUSION: DTS is a feasible tool for use as QC material and for PT under field conditions. Long-term (> 5 months) storage of DTS requires refrigeration.


Assuntos
Testes Diagnósticos de Rotina/instrumentação , Malária Falciparum/diagnóstico , Plasmodium falciparum/isolamento & purificação , Controle de Qualidade , Manejo de Espécimes/métodos , Benin , Libéria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...