Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 15(1): 5114, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38879593

RESUMO

The global scientific response to COVID 19 highlighted the urgent need for increased throughput and capacity in bioanalytical laboratories, especially for the precise quantification of proteins that pertain to health and disease. Acoustic ejection mass spectrometry (AEMS) represents a much-needed paradigm shift for ultra-fast biomarker screening. Here, a quantitative AEMS assays is presented, employing peptide immunocapture to enrich (i) 10 acute phase response (APR) protein markers from plasma, and (ii) SARS-CoV-2 NCAP peptides from nasopharyngeal swabs. The APR proteins were quantified in 267 plasma samples, in triplicate in 4.8 h, with %CV from 4.2% to 10.5%. SARS-CoV-2 peptides were quantified in triplicate from 145 viral swabs in 10 min. This assay represents a 15-fold speed improvement over LC-MS, with instrument stability demonstrated across 10,000 peptide measurements. The combination of speed from AEMS and selectivity from peptide immunocapture enables ultra-high throughput, reproducible quantitative biomarker screening in very large cohorts.


Assuntos
Biomarcadores , COVID-19 , Espectrometria de Massas , SARS-CoV-2 , Humanos , Biomarcadores/sangue , COVID-19/diagnóstico , COVID-19/virologia , COVID-19/sangue , SARS-CoV-2/imunologia , Espectrometria de Massas/métodos , Peptídeos , Proteínas do Nucleocapsídeo de Coronavírus/análise , Fosfoproteínas
2.
Clin Chem Lab Med ; 62(6): 1206-1216, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38253336

RESUMO

OBJECTIVES: Many reverse transcription polymerase chain reaction (RT-PCR) methods exist that can detect SARS-CoV-2 RNA in different matrices. RT-PCR is highly sensitive, although viral RNA may be detected long after active infection has taken place. SARS-CoV-2 proteins have shorter detection windows hence their detection might be more meaningful. Given salivary droplets represent a main source of transmission, we explored the detection of viral RNA and protein using four different detection platforms including SISCAPA peptide immunoaffinity liquid chromatography-mass spectrometry (SISCAPA-LC-MS) using polyclonal capture antibodies. METHODS: The SISCAPA-LC MS method was compared to RT-PCR, RT-loop-mediated isothermal amplification (RT-LAMP), and a lateral flow rapid antigen test (RAT) for the detection of virus material in the drool saliva of 102 patients hospitalised after infection with SARS-CoV-2. Cycle thresholds (Ct) of RT-PCR (E gene) were compared to RT-LAMP time-to-positive (TTP) (NE and Orf1a genes), RAT optical densitometry measurements (test line/control line ratio) and to SISCAPA-LC-MS for measurements of viral protein. RESULTS: SISCAPA-LC-MS showed low sensitivity (37.7 %) but high specificity (89.8 %). RAT showed lower sensitivity (24.5 %) and high specificity (100 %). RT-LAMP had high sensitivity (83.0 %) and specificity (100.0 %). At high initial viral RNA loads (<20 Ct), results obtained using SISCAPA-LC-MS correlated with RT-PCR (R2 0.57, p-value 0.002). CONCLUSIONS: Detection of SARS-CoV-2 nucleoprotein in saliva was less frequent than the detection of viral RNA. The SISCAPA-LC-MS method allowed processing of multiple samples in <150 min and was scalable, enabling high throughput.


Assuntos
COVID-19 , Espectrometria de Massas , Técnicas de Diagnóstico Molecular , RNA Viral , SARS-CoV-2 , Saliva , Humanos , Saliva/virologia , Saliva/química , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/imunologia , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/virologia , RNA Viral/análise , Espectrometria de Massas/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Masculino , Sensibilidade e Especificidade , Feminino , Pessoa de Meia-Idade , Fosfoproteínas/análise , Fosfoproteínas/imunologia , Proteínas do Nucleocapsídeo de Coronavírus/análise , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Antígenos Virais/análise , Antígenos Virais/imunologia , Adulto , Cromatografia Líquida/métodos
3.
Nat Commun ; 14(1): 1783, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36997517

RESUMO

Current methods for detecting infections either require a sample collected from an actively infected site, are limited in the number of agents they can query, and/or yield no information on the immune response. Here we present an approach that uses temporally coordinated changes in highly-multiplexed antibody measurements from longitudinal blood samples to monitor infection events at sub-species resolution across the human virome. In a longitudinally-sampled cohort of South African adolescents representing >100 person-years, we identify >650 events across 48 virus species and observe strong epidemic effects, including high-incidence waves of Aichivirus A and the D68 subtype of Enterovirus D earlier than their widespread circulation was appreciated. In separate cohorts of adults who were sampled at higher frequency using self-collected dried blood spots, we show that such events temporally correlate with symptoms and transient inflammatory biomarker elevations, and observe the responding antibodies to persist for periods ranging from ≤1 week to >5 years. Our approach generates a rich view of viral/host dynamics, supporting novel studies in immunology and epidemiology.


Assuntos
Enterovirus Humano D , Infecções por Enterovirus , Epidemias , Vírus , Adulto , Adolescente , Humanos , Viroma , Anticorpos Antivirais
4.
Clin Chem Lab Med ; 61(2): 302-310, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36395058

RESUMO

OBJECTIVES: During 2020, the UK's Department of Health and Social Care (DHSC) established the Moonshot programme to fund various diagnostic approaches for the detection of SARS-CoV-2, the pathogen behind the COVID-19 pandemic. Mass spectrometry was one of the technologies proposed to increase testing capacity. METHODS: Moonshot funded a multi-phase development programme, bringing together experts from academia, industry and the NHS to develop a state-of-the-art targeted protein assay utilising enrichment and liquid chromatography tandem mass spectrometry (LC-MS/MS) to capture and detect low levels of tryptic peptides derived from SARS-CoV-2 virus. The assay relies on detection of target peptides, ADETQALPQRK (ADE) and AYNVTQAFGR (AYN), derived from the nucleocapsid protein of SARS-CoV-2, measurement of which allowed the specific, sensitive, and robust detection of the virus from nasopharyngeal (NP) swabs. The diagnostic sensitivity and specificity of LC-MS/MS was compared with reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) via a prospective study. RESULTS: Analysis of NP swabs (n=361) with a median RT-qPCR quantification cycle (Cq) of 27 (range 16.7-39.1) demonstrated diagnostic sensitivity of 92.4% (87.4-95.5), specificity of 97.4% (94.0-98.9) and near total concordance with RT-qPCR (Cohen's Kappa 0.90). Excluding Cq>32 samples, sensitivity was 97.9% (94.1-99.3), specificity 97.4% (94.0-98.9) and Cohen's Kappa 0.95. CONCLUSIONS: This unique collaboration between academia, industry and the NHS enabled development, translation, and validation of a SARS-CoV-2 method in NP swabs to be achieved in 5 months. This pilot provides a model and pipeline for future accelerated development and implementation of LC-MS/MS protein/peptide assays into the routine clinical laboratory.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Pandemias , COVID-19/diagnóstico , Teste para COVID-19 , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Estudos Prospectivos , Técnicas de Laboratório Clínico/métodos , Sensibilidade e Especificidade , Peptídeos
5.
Anal Chem ; 94(50): 17379-17387, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36490367

RESUMO

The pandemic readiness toolbox needs to be extended, targeting different biomolecules, using orthogonal experimental set-ups. Here, we build on our Cov-MS effort using LC-MS, adding SISCAPA technology to enrich proteotypic peptides of the SARS-CoV-2 nucleocapsid (N) protein from trypsin-digested patient samples. The Cov2MS assay is compatible with most matrices including nasopharyngeal swabs, saliva, and plasma and has increased sensitivity into the attomole range, a 1000-fold improvement compared to direct detection in a matrix. A strong positive correlation was observed with qPCR detection beyond a quantification cycle of 30-31, the level where no live virus can be cultured. The automatable sample preparation and reduced LC dependency allow analysis of up to 500 samples per day per instrument. Importantly, peptide enrichment allows detection of the N protein in pooled samples without sensitivity loss. Easily multiplexed, we detect variants and propose targets for Influenza A and B detection. Thus, the Cov2MS assay can be adapted to test for many different pathogens in pooled samples, providing longitudinal epidemiological monitoring of large numbers of pathogens within a population as an early warning system.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Espectrometria de Massas/métodos , Peptídeos , Sensibilidade e Especificidade
6.
J Mass Spectrom Adv Clin Lab ; 26: 28-33, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36388059

RESUMO

Background: Despite its clear advantages over immunoassay-based testing, the measurement of serum thyroglobulin by mass spectrometry remains limited to a handful of institutions. Slow adoption by clinical laboratories could reflect limited accessibility to existing methods that have sensitivity comparable to modern immunoassays, as well as a lack of tools for calibration and assay harmonization. Methods: We developed and validated a liquid chromatography-tandem mass spectrometry-based assay for the quantification of serum thyroglobulin. The protocol combined peptide immunoaffinity purification using a commercially available, well-characterized monoclonal antibody and mobile phase modification with dimethylsulfoxide (DMSO) for enhanced sensitivity. To facilitate harmonization with other laboratories, we developed a novel, serum-based 5-point distributable reference material (Husky Ref). Results: The assay demonstrated a lower limit of quantification of 0.15 ng/mL (<20 %CV). Mobile phase DMSO increased signal intensity of the target peptide at least 3-fold, improving quantification at low concentrations. Calibration traceable to Husky Ref enabled harmonization between laboratories in an interlaboratory study. Conclusions: Sensitive mass spectrometry-based thyroglobulin measurement can be achieved using a monoclonal antibody during peptide immunoaffinity purification and the addition of mobile phase DMSO. Laboratories interested in deploying this assay can utilize the provided standard operating procedure and freely-available Husky Ref reference material.

7.
Elife ; 102021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34747696

RESUMO

Reliable, robust, large-scale molecular testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for monitoring the ongoing coronavirus disease 2019 (COVID-19) pandemic. We have developed a scalable analytical approach to detect viral proteins based on peptide immuno-affinity enrichment combined with liquid chromatography-mass spectrometry (LC-MS). This is a multiplexed strategy, based on targeted proteomics analysis and read-out by LC-MS, capable of precisely quantifying and confirming the presence of SARS-CoV-2 in phosphate-buffered saline (PBS) swab media from combined throat/nasopharynx/saliva samples. The results reveal that the levels of SARS-CoV-2 measured by LC-MS correlate well with their correspondingreal-time polymerase chain reaction (RT-PCR) read-out (r = 0.79). The analytical workflow shows similar turnaround times as regular RT-PCR instrumentation with a quantitative read-out of viral proteins corresponding to cycle thresholds (Ct) equivalents ranging from 21 to 34. Using RT-PCR as a reference, we demonstrate that the LC-MS-based method has 100% negative percent agreement (estimated specificity) and 95% positive percent agreement (estimated sensitivity) when analyzing clinical samples collected from asymptomatic individuals with a Ct within the limit of detection of the mass spectrometer (Ct ≤ 30). These results suggest that a scalable analytical method based on LC-MS has a place in future pandemic preparedness centers to complement current virus detection technologies.


Assuntos
COVID-19/diagnóstico , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Técnicas de Diagnóstico Molecular/métodos , Proteínas Virais/análise , COVID-19/virologia , Humanos , Modelos Lineares , Nasofaringe/virologia , Fragmentos de Peptídeos/análise , Proteômica , Reprodutibilidade dos Testes , SARS-CoV-2/química , Sensibilidade e Especificidade
8.
Prog Biomater ; 10(3): 185-194, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34370267

RESUMO

Titanium and its alloys are considered as appropriate replacements for the irreparable bone. Calcium phosphate coatings are widely used to improve the osteoinduction and osseointegration ability of titanium alloys. To further improve the performance of the calcium phosphate-coated implants, strontium (Sr) was introduced to partially replace the calcium ions. In this study, the effect of Sr ion addition on the fluorohydroxyapatite (FHA)-coated Ti6Al4V alloy was investigated and all the coatings were treated under hydrothermal condition. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were used to investigate the phases and microstructures, respectively. Shear tests were done to evaluate the bond strength of the coating layer. MTT, adhesion, and alkaline phosphatase tests were performed to evaluate the biocompatibility and osteogenic behavior of the samples. Results showed that the average crystallite size for the strontium-doped FHA samples was 48 nm and the bond strength had increased 13.15% in comparison with FHA-coated samples. Analysis of variance showed p value for all MTT tests at more than 0.322 and there was not any evidence of cell death after 7 days. The results of the ALP test showed that the increase of the cell activity in Sr samples from day 7 to 14 is three times higher than the FHA ones.

9.
JACS Au ; 1(6): 750-765, 2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-34254058

RESUMO

Rising population density and global mobility are among the reasons why pathogens such as SARS-CoV-2, the virus that causes COVID-19, spread so rapidly across the globe. The policy response to such pandemics will always have to include accurate monitoring of the spread, as this provides one of the few alternatives to total lockdown. However, COVID-19 diagnosis is currently performed almost exclusively by reverse transcription polymerase chain reaction (RT-PCR). Although this is efficient, automatable, and acceptably cheap, reliance on one type of technology comes with serious caveats, as illustrated by recurring reagent and test shortages. We therefore developed an alternative diagnostic test that detects proteolytically digested SARS-CoV-2 proteins using mass spectrometry (MS). We established the Cov-MS consortium, consisting of 15 academic laboratories and several industrial partners to increase applicability, accessibility, sensitivity, and robustness of this kind of SARS-CoV-2 detection. This, in turn, gave rise to the Cov-MS Digital Incubator that allows other laboratories to join the effort, navigate, and share their optimizations and translate the assay into their clinic. As this test relies on viral proteins instead of RNA, it provides an orthogonal and complementary approach to RT-PCR using other reagents that are relatively inexpensive and widely available, as well as orthogonally skilled personnel and different instruments. Data are available via ProteomeXchange with identifier PXD022550.

10.
Bioanalysis ; 12(13): 937-955, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32253915

RESUMO

Aim: High-frequency longitudinal tracking of inflammation using dried blood microsamples provides a new window for personalized monitoring of infections, chronic inflammatory disease and clinical trials of anti-inflammatory drugs. Results/methodology: Using 1662 dried blood spot samples collected by 16 subjects over periods of weeks to years, we studied the behavior of 12 acute phase response and related proteins in inflammation events correlated with infection, vaccination, surgery, intense exercise and Crohn's disease. Proteins were measured using SISCAPA mass spectrometry and normalized to constant plasma volume using low-variance proteins, generating high precision within-person biomarker trajectories with well-characterized personal baselines. Discussion/conclusion: The results shed new light on the dynamic regulation of APR responses, offering a new approach to visualization of multidimensional inflammation trajectories.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Adulto , Idoso , Feminino , Humanos , Inflamação/sangue , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
12.
Clin Chem ; 64(4): 697-704, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29321128

RESUMO

BACKGROUND: Lipoprotein-associated phospholipase A2 (Lp-PLA2), an enzyme associated with inflammation, is used as a biomarker for cardiovascular disease risk. Both the concentration and activity of Lp-PLA2 have been shown to be clinically relevant. However, there is a discordance between the serum concentration of Lp-PLA2 measured by the standard ELISA-based immunoassays and the activity of this enzyme, leading to substantial discordance in risk categorization depending on assay format. METHODS: We developed 2 LC-MS/MS-based assays to quantify serum Lp-PLA2 activity (multiple reaction monitoring detection of product) and concentration [stable isotope standards and capture by antipeptide antibody (SISCAPA) immunoaffinity], and we investigated their correlation to commercially offered colorimetric activity and immunometric concentrations assays. Associations between Lp-PLA2 and lipoproteins and the effect of selected detergents in liberating Lp-PLA2 were evaluated by use of immunoprecipitation and Western blot analyses. RESULTS: Serum Lp-PLA2 concentrations measured by quantitative SISCAPA-mass spectrometry were substantially higher than concentrations typically measured by immunoassay and showed an improved agreement with Lp-PLA2 activity. With detergents, liberation of Lp-PLA2 from lipoprotein complexes dramatically increased the amount of protein detected by immunoassay and improved the agreement with activity measurements. CONCLUSIONS: Quantitative analysis of Lp-PLA2 concentration and activity by LC-MS/MS assays provided key insight into resolving the well-documented discordance between Lp-PLA2 concentration (determined by immunoassay) and activity. Quantitative detection of Lp-PLA2 by immunoassay appears to be strongly inhibited by interaction of Lp-PLA2 with lipoprotein. Together, the results illustrate the advantages of quantitative LC-MS/MS for measurement of Lp-PLA2 concentration (by SISCAPA) and activity (by direct product detection).


Assuntos
1-Alquil-2-acetilglicerofosfocolina Esterase/sangue , Cromatografia Líquida/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Espectrometria de Massas em Tandem/métodos , Western Blotting , Colesterol/sangue , Detergentes/química , Humanos , Imunoprecipitação , Lipoproteínas/sangue
13.
Biomed Mater Eng ; 28(4): 325-338, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28869426

RESUMO

OBJECTIVE: In this paper, an adaptive method based on error entropy criterion is presented in order to eliminate noise from Electroencephalogram (EEG) signals. METHOD: Conventionally, the Mean-Squared Error (MSE) criterion is the dominant criterion deployed in the adaptive filters for this purpose. By deploying MSE, only second-order moment of the error distribution is optimized, which is not adequate for the noisy EEG signal in which the contaminating noises are typically non-Gaussian. By minimizing error entropy, all moments of the error distribution are minimized; hence, using the Minimum Error Entropy (MEE) algorithm instead of MSE-based adaptive algorithms will improve the performance of noise elimination. RESULTS: Simulation results indicate that the proposed method has a better performance compared to conventional MSE-based algorithm in terms of signal to noise ratio and steady state error.


Assuntos
Eletroencefalografia , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Algoritmos , Entropia , Humanos
14.
Bioanalysis ; 8(15): 1597-1609, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27420772

RESUMO

BACKGROUND: The use of DBS for quantitative protein biomarker measurement has been hindered by issues associated with blood hematocrit variations and lack of detection sensitivity, particularly when multiple biomarkers are measured. MATERIALS & METHODS: An automated, multiplexed SISCAPA analysis was used to normalize blood volume variations in DBS and quantify proteins of varying abundance in longitudinal specimens. CONCLUSION: The results showed that after normalizing the spot-to-spot hematocrit variations, peptide surrogates of protein biomarkers could be accurately quantitated in DBS. This allowed the establishment of baselines for a variety of biomarkers in multiple individuals and enabled detection of changes over time, thus offering an effective solution for longitudinal personal monitoring of biomarkers relevant in health and disease.


Assuntos
Proteínas Sanguíneas/análise , Teste em Amostras de Sangue Seco/métodos , Biomarcadores/análise , Biomarcadores/sangue , Volume Sanguíneo , Cromatografia Líquida/métodos , Hematócrito , Humanos , Espectrometria de Massas em Tandem/métodos , Fluxo de Trabalho
16.
N Biotechnol ; 33(5 Pt A): 494-502, 2016 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-26772726

RESUMO

Efficient robotic workflows for trypsin digestion of human plasma and subsequent antibody-mediated peptide enrichment (the SISCAPA method) were developed with the goal of improving assay precision and throughput for multiplexed protein biomarker quantification. First, an 'addition only' tryptic digestion protocol was simplified from classical methods, eliminating the need for sample cleanup, while improving reproducibility, scalability and cost. Second, methods were developed to allow multiplexed enrichment and quantification of peptide surrogates of protein biomarkers representing a very broad range of concentrations and widely different molecular masses in human plasma. The total workflow coefficients of variation (including the 3 sequential steps of digestion, SISCAPA peptide enrichment and mass spectrometric analysis) for 5 proteotypic peptides measured in 6 replicates of each of 6 different samples repeated over 6 days averaged 3.4% within-run and 4.3% across all runs. An experiment to identify sources of variation in the workflow demonstrated that MRM measurement and tryptic digestion steps each had average CVs of ∼2.7%. Because of the high purity of the peptide analytes enriched by antibody capture, the liquid chromatography step is minimized and in some cases eliminated altogether, enabling throughput levels consistent with requirements of large biomarker and clinical studies.


Assuntos
Proteínas Sanguíneas/análise , Automação , Biomarcadores/análise , Biotecnologia , Proteínas Sanguíneas/química , Proteínas Sanguíneas/imunologia , Humanos , Peso Molecular , Peptídeos/química , Peptídeos/isolamento & purificação , Proteômica/métodos , Reprodutibilidade dos Testes , Robótica , Espectrometria de Massas em Tandem/métodos , Tripsina , Fluxo de Trabalho
17.
Methods ; 81: 74-85, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25766926

RESUMO

A fully automated workflow was developed and validated for simultaneous quantification of the cardiovascular disease risk markers apolipoproteins A-I (apoA-I) and B-100 (apoB-100) in clinical sera. By coupling of stable-isotope standards and capture by anti-peptide antibodies (SISCAPA) for enrichment of proteotypic peptides from serum digests to matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS detection, the standardized platform enabled rapid, liquid chromatography-free quantification at a relatively high throughput of 96 samples in 12h. The average imprecision in normo- and triglyceridemic serum pools was 3.8% for apoA-I and 4.2% for apoB-100 (4 replicates over 5 days). If stored properly, the MALDI target containing enriched apoA-1 and apoB-100 peptides could be re-analyzed without any effect on bias or imprecision for at least 7 days after initial analysis. Validation of the workflow revealed excellent linearity for daily calibration with external, serum-based calibrators (R(2) of 0.984 for apoA-I and 0.976 for apoB-100 as average over five days), and absence of matrix effects or interference from triglycerides, protein content, hemolysates, or bilirubins. Quantification of apoA-I in 93 normo- and hypertriglyceridemic clinical sera showed good agreement with immunoturbidimetric analysis (slope = 1.01, R(2) = 0.95, mean bias = 4.0%). Measurement of apoB-100 in the same clinical sera using both methods, however, revealed several outliers in SISCAPA-MALDI-TOF-MS measurements, possibly as a result of the lower MALDI-TOF-MS signal intensity (slope = 1.09, R(2) = 0.91, mean bias = 2.0%). The combination of analytical performance, rapid cycle time and automation potential validate the SISCAPA-MALDI-TOF-MS platform as a valuable approach for standardized and high-throughput quantification of apoA-I and apoB-100 in large sample cohorts.


Assuntos
Apolipoproteína A-I/sangue , Apolipoproteína B-100/sangue , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Anticorpos Monoclonais , Apolipoproteína A-I/imunologia , Apolipoproteína B-100/imunologia , Biomarcadores/sangue , Calibragem , Humanos , Fluxo de Trabalho
18.
Clin Chem ; 59(10): 1514-22, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23857672

RESUMO

BACKGROUND: Biomarker validation remains one of the most challenging constraints to the development of new diagnostic assays. To facilitate biomarker validation, we previously developed a chromatography-free stable isotope standards and capture by antipeptide antibodies (SISCAPA)-MALDI assay allowing rapid, high-throughput quantification of protein analytes in large sample sets. Here we applied this assay to the measurement of a surrogate proteotypic peptide from protein C inhibitor (PCI) in sera from patients with prostate cancer. METHODS: A 2-plex SISCAPA-MALDI assay for quantification of proteotypic peptides from PCI and soluble transferrin receptor (sTfR) was used to measure these peptides in 159 trypsin-digested sera collected from 51 patients with prostate cancer. These patients had been treated with radiation with or without neoadjuvant androgen deprivation. RESULTS: Patients who experienced biochemical recurrence of prostate cancer showed decreased serum concentrations of the PCI peptide analyte within 18 months of treatment. The PCI peptide concentrations remained increased in the sera of patients who did not experience cancer recurrence. Prostate-specific antigen concentrations had no predictive value during the same time period. CONCLUSIONS: The high-throughput, liquid chromatography-free SISCAPA-MALDI assay is capable of rapid quantification of proteotypic PCI and sTfR peptide analytes in complex serum samples. Decreased serum concentrations of the PCI peptide were found to be related to recurrence of prostate cancer in patients treated with radiation with or without hormone therapy. However, a larger cohort of patients will be required for unequivocal validation of the PCI peptide as a biomarker for clinical use.


Assuntos
Peptídeos/sangue , Neoplasias da Próstata/diagnóstico , Inibidor da Proteína C/sangue , Antagonistas de Androgênios/uso terapêutico , Ensaios de Triagem em Larga Escala , Humanos , Estudos Longitudinais , Masculino , Recidiva Local de Neoplasia , Neoplasias da Próstata/sangue , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Proteólise , Receptores da Transferrina/sangue , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
19.
J Proteome Res ; 11(12): 5642-9, 2012 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-23126378

RESUMO

We investigated the utility of an SPE-MS/MS platform in combination with a modified SISCAPA workflow for chromatography-free MRM analysis of proteotypic peptides in digested human plasma. This combination of SISCAPA and SPE-MS/MS technology allows sensitive, MRM-based quantification of peptides from plasma digests with a sample cycle time of ∼7 s, a 300-fold improvement over typical MRM analyses with analysis times of 30-40 min that use liquid chromatography upstream of MS. The optimized system includes capture and enrichment to near purity of target proteotypic peptides using rigorously selected, high affinity, antipeptide monoclonal antibodies and reduction of background peptides using a novel treatment of magnetic bead immunoadsorbents. Using this method, we have successfully quantitated LPS-binding protein and mesothelin (concentrations of ∼5000 ng/mL and ∼10 ng/mL, respectively) in human plasma. The method eliminates the need for upstream liquid-chromatography and can be multiplexed, thus facilitating quantitative analysis of proteins, including biomarkers, in large sample sets. The method is ideal for high-throughput biomarker validation after affinity enrichment and has the potential for applications in clinical laboratories.


Assuntos
Proteínas Sanguíneas/análise , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas/métodos , Peptídeos/sangue , Software , Proteínas de Fase Aguda/análise , Anticorpos Monoclonais/química , Afinidade de Anticorpos , Biomarcadores/sangue , Proteínas de Transporte/análise , Cromatografia Líquida , Proteínas Ligadas por GPI/sangue , Humanos , Glicoproteínas de Membrana/análise , Mesotelina , Proteômica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
20.
J Proteome Res ; 11(3): 1868-78, 2012 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-22257466

RESUMO

We have investigated the precision of peptide quantitation by MALDI-TOF mass spectrometry (MS) using six pairs of proteotypic peptides (light) and same-sequence stable isotope labeled synthetic internal standards (heavy). These were combined in two types of dilution curves spanning 100-fold and 2000-fold ratios. Coefficients of variation (CV; standard deviation divided by mean value) were examined across replicate MALDI spots using a reflector acquisition method requiring 100 000 counts for the most intense peak in each summed spectrum. The CV of light/heavy peptide centroid peak area ratios determined on four replicate spots per sample, averaged across 11 points of a 100-fold dilution curve and over all six peptides, was 2.2% (ranging from 1.5 to 3.7% among peptides) at 55 fmol total (light + heavy) of each peptide applied per spot, and 2.5% at 11 fmol applied. The average CV of measurements at near-equivalence (light = heavy, the center of the dilution curve) for the six peptides was 1.0%, about 17-fold lower CV than that observed when five peptides were ratioed to a sixth peptide (i.e., a different-sequence internal standard). Response curves across the 100-fold range were not completely linear but could be closely modeled by a power law fit giving R(2) values >0.998 for all peptides. The MALDI-TOF MS method was used to determine the endogenous level of a proteotypic peptide (EDQYHYLLDR) of human protein C inhibitor (PCI) in a plasma digest after enrichment by capture on a high affinity antipeptide antibody, a technique called stable isotope standards and capture by anti-peptide antibodies (SISCAPA). The level of PCI was determined to be 770 ng/mL with a replicate measurement CV of 1.5% and a >14 000-fold target enrichment via SISCAPA-MALDI-TOF. These results indicate that MALDI-TOF technology can provide precise quantitation of high-to-medium abundance peptide biomarkers over a 100-fold dynamic range when ratioed to same-sequence labeled internal standards and enriched to near purity by specific antibody capture. The robustness and throughput of MALDI-TOF in comparison to conventional nano-LC-MS technology could enable currently impractical large-scale verification studies of protein biomarkers.


Assuntos
Fragmentos de Peptídeos/química , Sequência de Aminoácidos , Calibragem , Humanos , Dados de Sequência Molecular , Peso Molecular , Fragmentos de Peptídeos/sangue , Inibidor da Proteína C/sangue , Inibidor da Proteína C/química , Proteólise , Proteômica , Padrões de Referência , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/normas , Tripsina/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...