1.
J Microsc ; 269(3): 179-186, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28815683

RESUMO

Imaging of the surface of materials by atomic force microscopy under tapping and phase imaging mode, with use of modified probes is addressed. In this study, the circularly shaped holes located in varying distance from the probe base, were cut out by focused ion beam. Such modification was a consequence of the results of the previous experiments (probe tip sharpening and cantilever thinning) where significant improvement of image quality in tapping and phase imaging mode has been revealed. The solution proposed herein gives similar results, but is much simpler from the technological point of view. Shorter exposition time of the tip onto gallium ions during FIB processing allows to reduce material degradation. The aim of this modification was to change harmonic oscillators' properties in the simplest and fastest way, to obtain stronger signal for higher resonant frequencies, which can be advantageous for improving the quality of imaging in PI mode. Probes shaped in that way were used for AFM investigations with Bruker AFM nanoscope 8. As a testing material, titanium roughness standard sample, supplied by Bruker, was used. The results have shown that the modifications performed within these studies influence the oscillation of the probes, which in some cases may result in deterioration of the imaging quality under tapping mode for one or both self-resonant frequencies. However, phase imaging results obtained using modified probes are of higher quality. The numerical simulations performed by application of finite element method were used to explain the results obtained experimentally. Phenomenon described within this study allows to apply developed modelling methodology for prediction of effects of various modifications on the probes' tip, and as a result, to predict how proposed modifications will affect AFM imaging quality.

2.
Micron ; 66: 23-30, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25080273

RESUMO

This study concerns imaging of the structure of materials using AFM tapping (TM) and phase imaging (PI) mode, using probes modified with focused ion beam (FIB). Three kinds of modifications were applied - thinning of the cantilever, sharpening of the tip and combination of these two modifications. Probes shaped in that way were used for AFM investigations with Bruker AFM Nanoscope 8. As a testing material, titanium roughness standard supplied by Bruker was used. The results show that performed modifications influence the oscillation of the probes. In particular thinning of the cantilever enables one to acquire higher self-resonant frequencies, which can be advantageous for improving the quality of imaging in PI mode. It was found that sharpening the tip improves imaging resolution in tapping mode, which is consistent with existing knowledge, but lowered the quality of high frequency topography images. In this paper the Finite Element Method (FEM) was used to explain the results obtained experimentally.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...