Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Br J Anaesth ; 133(2): 277-287, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38797635

RESUMO

BACKGROUND: It is unclear whether optimising intraoperative cardiac index can reduce postoperative complications. We tested the hypothesis that maintaining optimised postinduction cardiac index during and for the first 8 h after surgery reduces the incidence of a composite outcome of complications within 28 days after surgery compared with routine care in high-risk patients having elective major open abdominal surgery. METHODS: In three German and two Spanish centres, high-risk patients having elective major open abdominal surgery were randomised to cardiac index-guided therapy to maintain optimised postinduction cardiac index (cardiac index at which pulse pressure variation was <12%) during and for the first 8 h after surgery using intravenous fluids and dobutamine or to routine care. The primary outcome was the incidence of a composite outcome of moderate or severe complications within 28 days after surgery. RESULTS: We analysed 318 of 380 enrolled subjects. The composite primary outcome occurred in 84 of 152 subjects (55%) assigned to cardiac index-guided therapy and in 77 of 166 subjects (46%) assigned to routine care (odds ratio: 1.87, 95% confidence interval: 1.03-3.39, P=0.038). Per-protocol analyses confirmed the results of the primary outcome analysis. CONCLUSIONS: Maintaining optimised postinduction cardiac index during and for the first 8 h after surgery did not reduce, and possibly increased, the incidence of a composite outcome of complications within 28 days after surgery compared with routine care in high-risk patients having elective major open abdominal surgery. Clinicians should not strive to maintain optimised postinduction cardiac index during and after surgery in expectation of reducing complications. CLINICAL TRIAL REGISTRATION: NCT03021525.


Assuntos
Abdome , Complicações Pós-Operatórias , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Abdome/cirurgia , Débito Cardíaco , Dobutamina/administração & dosagem , Hidratação/métodos , Idoso de 80 Anos ou mais , Monitorização Intraoperatória/métodos , Cardiotônicos/uso terapêutico , Cardiotônicos/administração & dosagem , Procedimentos Cirúrgicos Eletivos/efeitos adversos
2.
Physiol Meas ; 45(3)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38422512

RESUMO

Objective. Since pulse wave transit time (PWTT) shortens as pulmonary artery pressure (PAP) increases it was suggested as a potential non-invasive surrogate for PAP. The state of tidal lung filling is also known to affect PWTT independently of PAP. The aim of this retrospective analysis was to test whether respiratory gating improved the correlation coefficient between PWTT and PAP.Approach. In each one of five anesthetized and mechanically ventilated pigs two high-fidelity pressure catheters were placed, one directly behind the pulmonary valve, and the second one in a distal branch of the pulmonary artery. PAP was raised using the thromboxane A2 analogue U46619 and animals were ventilated in a pressure controlled mode (I:E ratio 1:2, respiratory rate 12/min, tidal volume of 6 ml kg-1). All signals were recorded using the multi-channel platform PowerLab®. The arrival of the pulse wave at each catheter tip was determined using a MATLAB-based modified hyperbolic tangent algorithm and PWTT calculated as the time interval between these arrivals.Main results. Correlation coefficient for PWTT and mean PAP wasr= 0.932 for thromboxane. This correlation coefficient increased considerably when heart beats either at end-inspiration (r= 0.978) or at end-expiration (r= 0.985) were selected (=respiratory gating).Significance. The estimation of mean PAP from PWTT improved significantly when taking the respiratory cycle into account. Respiratory gating is suggested to improve for the estimation of PAP by PWTT.


Assuntos
Hipertensão Pulmonar , Animais , Suínos , Artéria Pulmonar , Estudos Retrospectivos , Frequência Cardíaca , Análise de Onda de Pulso , Pressão Sanguínea
3.
J Clin Monit Comput ; 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381359

RESUMO

Haemodynamic monitoring and management are cornerstones of perioperative care. The goal of haemodynamic management is to maintain organ function by ensuring adequate perfusion pressure, blood flow, and oxygen delivery. We here present guidelines on "Intraoperative haemodynamic monitoring and management of adults having non-cardiac surgery" that were prepared by 18 experts on behalf of the German Society of Anaesthesiology and Intensive Care Medicine (Deutsche Gesellschaft für Anästhesiologie und lntensivmedizin; DGAI).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...