Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Exp Physiol ; 109(6): 992-1003, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38711207

RESUMO

Young individuals with post-traumatic stress disorder (PTSD) display peripheral vascular and autonomic nervous system dysfunction, two factors potentially stemming from a redox imbalance. It is currently unclear if these aforementioned factors, observed at rest, alter peripheral haemodynamic responses to exercise in this population. This study examined haemodynamic responses to handgrip exercise in young individuals with PTSD following acute antioxidant (AO) supplementation. Thirteen young individuals with PTSD (age 23 ± 3 years), and 13 age- and sex-matched controls (CTRL) participated in the study. Exercise-induced changes to arm blood flow (BF), mean arterial pressure (MAP) and vascular conductance (VC) were evaluated across two workloads of rhythmic handgrip exercise (3 and 6 kg). The PTSD group participated in two visits, consuming either a placebo (PL) or AO prior to their visits. The PTSD group demonstrated significantly lower VC (P = 0.04) across all exercise workloads (vs. CTRL), which was significantly improved following AO supplementation. In the PTSD group, AO supplementation improved VC in participants possessing the lowest VC responses to handgrip exercise, with AO supplementation significantly improving VC responses (3 and 6 kg: P < 0.01) by blunting elevated exercise-induced MAP responses (3 kg: P = 0.01; 6 kg: P < 0.01). Lower VC responses during handgrip exercise were improved following AO supplementation in young individuals with PTSD. AO supplementation was associated with a blunting of exercise-induced MAP responses in individuals with PTSD displaying elevated MAP responses. This study revealed that young individuals with PTSD exhibit abnormal, peripherally mediated exercise responses that may be linked to a redox imbalance.


Assuntos
Antioxidantes , Suplementos Nutricionais , Exercício Físico , Força da Mão , Transtornos de Estresse Pós-Traumáticos , Humanos , Força da Mão/fisiologia , Antioxidantes/administração & dosagem , Masculino , Feminino , Adulto Jovem , Transtornos de Estresse Pós-Traumáticos/fisiopatologia , Exercício Físico/fisiologia , Adulto , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Pressão Sanguínea/fisiologia , Pressão Sanguínea/efeitos dos fármacos , Fluxo Sanguíneo Regional/fisiologia , Fluxo Sanguíneo Regional/efeitos dos fármacos
2.
CHEST Pulm ; 2(1)2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38737731

RESUMO

BACKGROUND: Pulmonary nodules represent a growing health care burden because of delayed diagnosis of malignant lesions and overtesting for benign processes. Clinical prediction models were developed to inform physician assessment of pretest probability of nodule malignancy but have not been validated in a high-risk cohort of nodules for which biopsy was ultimately performed. RESEARCH QUESTION: Do guideline-recommended prediction models sufficiently discriminate between benign and malignant nodules when applied to cases referred for biopsy by navigational bronchoscopy? STUDY DESIGN AND METHODS: We assembled a prospective cohort of 322 indeterminate pulmonary nodules in 282 patients referred to a tertiary medical center for diagnostic navigational bronchoscopy between 2017 and 2019. We calculated the probability of malignancy for each nodule using the Brock model, Mayo Clinic model, and Veterans Affairs (VA) model. On a subset of 168 patients who also had PET-CT scans before biopsy, we also calculated the probability of malignancy using the Herder model. The performance of the models was evaluated by calculating the area under the receiver operating characteristic curves (AUCs) for each model. RESULTS: The study cohort contained 185 malignant and 137 benign nodules (57% prevalence of malignancy). The malignant and benign cohorts were similar in terms of size, with a median longest diameter for benign and malignant nodules of 15 and 16 mm, respectively. The Brock model, Mayo Clinic model, and VA model showed similar performance in the entire cohort (Brock AUC, 0.70; 95% CI, 0.64-0.76; Mayo Clinic AUC, 0.70; 95% CI, 0.64-0.76; VA AUC, 0.67; 95% CI, 0.62-0.74). For 168 nodules with available PET-CT scans, the Herder model had an AUC of 0.77 (95% CI, 0.68-0.85). INTERPRETATION: Currently available clinical models provide insufficient discrimination between benign and malignant nodules in the common clinical scenario in which a patient is being referred for biopsy, especially when PET-CT scan information is not available.

3.
Eur J Radiol ; 175: 111406, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38490129

RESUMO

PURPOSE: To compare image quality, assess inter-reader variability, and evaluate the diagnostic efficacy of routine clinical lumbar spine sequences at 0.55T compared with those collected at 1.5/3T to assess common spine pathology. METHODS: 665 image series across 70 studies, collected at 0.55T and 1.5/3T, were assessed by two neuroradiology fellows for overall imaging quality (OIQ), artifacts, and accurate visualization of anatomical features (intervertebral discs, neural foramina, spinal cord, bone marrow, and conus / cauda equina nerve roots) using a 4-point Likert scale (1 = non-diagnostic to 4 = excellent). For the 0.55T scans, the most appropriate diagnosis(es) from a picklist of common spine pathologies was selected. The mean ± SD of all scores for all features for each sequence and reader at 0.55T and 1.5/3T were calculated. Paired t-tests (p ≤ 0.05) were used to compare ratings between field strengths. The inter-reader agreement was calculated using linear-weighted Cohen's Kappa coefficient (p ≤ 0.05). Unpaired VCG analysis for OIQ was additionally employed to represent differences between 0.55T and 1.5/3T (95 % CI). RESULTS: All sequences at 0.55T were rated as acceptable (≥2) for diagnostic use by both readers despite significantly lower scores for some compared to those at 1.5/3T. While there was low inter-reader agreement on individual scores, the agreement on the diagnosis was high, demonstrating the potential of this system for detecting routine spine pathology. CONCLUSIONS: Clinical lumbar spine imaging at 0.55T produces diagnostic-quality images demonstrating the feasibility of its use in diagnosing spinal pathology, including osteomyelitis/discitis, post-surgical changes with complications, and metastatic disease.


Assuntos
Vértebras Lombares , Imageamento por Ressonância Magnética , Doenças da Coluna Vertebral , Humanos , Vértebras Lombares/diagnóstico por imagem , Doenças da Coluna Vertebral/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Feminino , Pessoa de Meia-Idade , Adulto , Variações Dependentes do Observador , Artefatos , Sensibilidade e Especificidade , Idoso
4.
Acad Radiol ; 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38320946

RESUMO

RATIONALE AND OBJECTIVES: This study aims to assess the quality of abdominal MR images acquired on a commercial 0.55T scanner and compare these images with those acquired on conventional 1.5T/3T scanners in both healthy subjects and patients. MATERIALS AND METHODS: Fifteen healthy subjects and 52 patients underwent abdominal Magnetic Resonance Imaging at 0.55T. Images were also collected in healthy subjects at 1.5T, and comparison 1.5/3T images identified for 28 of the 52 patients. Image quality was rated by two radiologists on a 4-point Likert scale. Readers were asked whether they could answer the clinical question for patient studies. Wilcoxon signed-rank test was used to test for significant differences in image ratings and acquisition times, and inter-reader reliability was computed. RESULTS: The overall image quality of all sequences at 0.55T were rated as acceptable in healthy subjects. Sequences were modified to improve signal-to-noise ratio and reduce artifacts and deployed for clinical use; 52 patients were enrolled in this study. Radiologists were able to answer the clinical question in 52 (reader 1) and 46 (reader 2) of the patient cases. Average image quality was considered to be diagnostic (>3) for all sequences except arterial phase FS 3D T1w gradient echo (GRE) and 3D magnetic resonance cholangiopancreatography for one reader. In comparison to higher field images, significantly lower scores were given to 0.55T IP 2D GRE and arterial phase FS 3D T1w GRE, and significantly higher scores to diffusion-weighted echo planar imaging at 0.55T; other sequences were equivalent. The average scan time at 0.55T was 54 ± 10 minutes vs 36 ± 11 minutes at higher field strengths (P < .001). CONCLUSION: Diagnostic-quality abdominal MR images can be obtained on a commercial 0.55T scanner at a longer overall acquisition time compared to higher field systems, although some sequences may benefit from additional optimization.

5.
NMR Biomed ; : e5017, 2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37654047

RESUMO

The purpose of this study was to assess the quality of clinical brain imaging in healthy subjects and patients on an FDA-approved commercial 0.55 T MRI scanner, and to provide information about the feasibility of using this scanner in a clinical workflow. In this IRB-approved study, brain examinations on the scanner were prospectively performed in 10 healthy subjects (February-April 2022) and retrospectively derived from 44 patients (February-July 2022). Images collected using the following pulse sequences were available for assessment: axial DWI (diffusion-weighted imaging), apparent diffusion coefficient maps, 2D axial fluid-attenuated inversion recovery images, axial susceptibility-weighted images (both magnitude and phase), sagittal T1 -weighted (T1w) Sampling Perfection with Application Optimized Contrast images, sagittal T1w MPRAGE (magnetization prepared rapid gradient echo) with contrast enhancement, axial T1w turbo spin echo (TSE) with and without contrast enhancement, and axial T2 -weighted TSE. Two readers retrospectively and independently evaluated image quality and specific anatomical features in a blinded fashion on a four-point Likert scale, with a score of 1 being unacceptable and 4 being excellent, and determined the ability to answer the clinical question in patients. For each category of image sequences, the mean, standard deviation, and percentage of unacceptable quality images (<2) were calculated. Acceptable (rating ≥ 2) image quality was achieved at 0.55 T in all sequences for patients and 85% of the sequences for healthy subjects. Radiologists were able to answer the clinical question in all patients scanned. In total, 50% of the sequences used in patients and about 60% of the sequences used in healthy subjects exhibited good (rating ≥ 3) image quality. Based on these findings, we conclude that diagnostic quality clinical brain images can be successfully collected on this commercial 0.55 T scanner, indicating that the routine brain imaging protocol may be deployed on this system in the clinical workflow.

6.
Med Sci Sports Exerc ; 55(5): 900-910, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728956

RESUMO

PURPOSE: Adequate, robust vascular responses to passive and active movement represent two distinct components linked to normal, healthy cardiovascular function. Currently, limited research exists determining if these vascular responses are altered in premenopausal females (PMF) when compared across sex or menstrual cycle phase. METHODS: Vascular responses to passive leg movement (PLM) and handgrip (HG) exercise were assessed in PMF ( n = 21) and age-matched men ( n = 21). A subset of PMF subjects ( n = 11) completed both assessments during the early and late follicular phase of their menstrual cycle. Microvascular function was assessed during PLM via changes in leg blood flow, and during HG exercise, via steady-state arm vascular conductance. Macrovascular (brachial artery [BA]) function was assessed during HG exercise via BA dilation responses as well as BA shear rate-dilation slopes. RESULTS: Leg microvascular function, determined by PLM, was not different between sexes or across menstrual cycle phase. However, arm microvascular function, demonstrated by arm vascular conductance, was lower in PMF compared with men at rest and during HG exercise. Macrovascular function was not different between sexes or across menstrual cycle phase. CONCLUSIONS: This study identified similar vascular function across sex and menstrual cycle phase seen in microvasculature of the leg and macrovascular (BA) of the arm. Although arm microvascular function was unaltered by menstrual cycle phase in PMF, it was revealed to be significantly lower when compared with age-matched men highlighting a sex difference in vascular/blood flow regulation during small muscle mass exercise.


Assuntos
Força da Mão , Movimento , Humanos , Masculino , Feminino , Força da Mão/fisiologia , Artéria Braquial/fisiologia , Hemodinâmica , Ciclo Menstrual , Fluxo Sanguíneo Regional/fisiologia , Vasodilatação/fisiologia
7.
J Appl Physiol (1985) ; 134(2): 277-287, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36548512

RESUMO

This study sought to determine if high sodium (HS) intake in salt resistant (SR) individuals attenuates upper limb arterial dilation in response to reactive (occlusion) and active (exercise) hyperemia, two stimuli with varying vasodilatory mechanisms, and the role of oxidative stress in this response. Ten young, SR participants (9 males, 1 female) consumed a 7-day HS (6,900 mg/day) and a 7-day recommended sodium intake (RI: 2,300 mg/day) diet in a randomized order. On the last day of each diet, brachial artery (BA) function was evaluated via reactive (RH-FMD: 5 min of cuff occlusion) and active [handgrip (HG) exercise] hyperemia after consumption of both placebo (PL) and antioxidants (AO). The HS diet significantly elevated sodium excretion (P < 0.05), but mean arterial blood pressure was unchanged. During the PL condition, the HS diet significantly reduced RH-FMD when compared with RI diet (P = 0.01), but this reduction was significantly restored (P = 0.01) when supplemented with AO (HS + PL: 5.9 ± 3.4; HS + AO: 8.2 ± 2.7; RI + PL: 8.9 ± 4.7; RI + AO: 7.0 ± 2.1%). BA shear-to-dilation slopes, evaluated across all HG exercise workloads, were not significantly different across sodium intervention or AO supplementation. In SR individuals, HS intake impaired BA function when assessed via RH-FMD, but was restored with acute AO consumption suggesting oxidative stress as a contributor to this dysfunction. However, exercise-induced BA dilation was unaltered, potentially implicating an inability of HS intake to influence the mechanisms responsible for effectively maintaining skeletal muscle perfusion during exercise.NEW & NOTEWORTHY This study examined if high sodium (HS) intake in salt resistant (SR) individuals attenuates brachial artery (BA) flow-mediated dilation in response to reactive (occlusion) and active (exercise) hyperemia. In SR individuals, HS intake impaired reactive hyperemia-induced BA dilation, but not exercise-induced BA dilation. This finding suggests that although brachial artery nitric oxide bioavailability may be reduced following HS intake, the redundant mechanisms associated with adequate upper limb blood flow regulation during exercise are maintained.


Assuntos
Hiperemia , Sódio na Dieta , Feminino , Humanos , Masculino , Velocidade do Fluxo Sanguíneo/fisiologia , Artéria Braquial/fisiologia , Dilatação , Endotélio Vascular/fisiologia , Força da Mão/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Sódio , Extremidade Superior , Vasodilatação/fisiologia
8.
Microvasc Res ; 145: 104445, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36209773

RESUMO

PURPOSE: Young non-Hispanic black (BL) males have displayed lower blood flow (BF) and vascular conductance (VC), but intact functional sympatholysis, during upper limb exercise when compared to non-Hispanic white (WH) males. This study sought to explore if similar differences were also present in the lower limbs. METHODS: Thirteen young BL males and thirteen WH males completed one visit comprised of rhythmic lower limb (plantar flexion) exercise as well as upper limb (handgrip) exercise for a limb-specific comparison. Limb BF, mean arterial pressure (MAP), and VC were evaluated at three submaximal workloads (8, 16, and 24 kg). To determine potential limb differences in functional sympatholysis, the impact of sympathetic nervous system activation (via cold-pressor test (CPT)) was evaluated at rest and during steady state exercise (30 % of maximal voluntary contraction) on a subsequent visit. RESULTS: MAP responses to lower and upper limb exercise were elevated in young BL males (vs WH males), resulting in significantly lower VC responses in the upper limb, but not the lower limb. Further, BL males, when compared to WH males, revealed no differences in functional sympatholysis, evident by similar responses in both the exercising leg and arm VC during CPT. CONCLUSION: The findings of the current study indicate that although elevated MAP responses were observed during both lower and upper limb exercise in young BL males, vascular conductance was only hindered in the upper limbs. This may potentially highlight enhanced compensatory mechanisms in the lower limb (vs upper limb) to maintain perfusion in young BL males.


Assuntos
Força da Mão , Simpatolíticos , Masculino , Humanos , Força da Mão/fisiologia , Fluxo Sanguíneo Regional , Exercício Físico/fisiologia , Extremidade Inferior , Pressão Sanguínea , Músculo Esquelético
9.
Behav Anal Pract ; 14(4): 1085-1091, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34868816

RESUMO

Behavioral skills training (BST) has been demonstrated to be an effective method for training staff to perform skills with high fidelity in a relatively short amount of time. In the current study, three components of direct instruction (DI) were trained using BST. The participants were two classroom instructors with prior experience implementing DI with students with autism. The targets for staff training were accuracy with signal delivery, error correction, and delivery of praise. A multiple-baseline design across skills was used to evaluate the effects of BST for each participant. Generalization probes were conducted with a student with autism during baseline and after mastery with each skill was demonstrated. BST rapidly increased staff performance across skills, with generalization demonstrated during classroom probes. This study extends the use of BST to training staff to implement DI, and the results suggest that BST resulted in improved teacher performance of the targeted skills during generalization probes with students.

10.
Microvasc Res ; 135: 104147, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33610562

RESUMO

PURPOSE: Lower limb microvascular dysfunction resulting from prolonged sitting (PS) bouts has been revealed to occur independent of sex. Although acute antioxidant supplementation has been reported to blunt conduit artery dysfunction following PS in young males, it is unknown if this protective effect extends to the microvasculature or is relevant in young females, who possess intrinsic vascular protective mechanisms specific to antioxidant defense. Therefore, this study employed an acute antioxidant supplementation to further examine sex differences during PS with a specific focus on microvascular function. METHODS: On two separate visits, 14 females (23 ± 3 years) and 12 males (25 ± 4 years) had leg microvascular function (LMVF) assessed (via the passive leg movement technique) before and after 1.5 h of sitting. Prior to each visit, one gram of vitamin C (VC) or placebo (PL) was consumed. RESULTS: PS significantly reduced LMVF [PL: (M: -34 ± 20; F: -23 ± 18%; p < 0.01) independent of sex (p = 0.7)], but the VC condition only blunted this reduction in males (VC: -3 ± 20%; p < 0.01), but not females (VC: -18 ± 25%; p = 0.5). CONCLUSION: Young males and females reported similar reductions LMVF following PS, but only the young males reported a preservation of LMVF following the VC supplementation. This finding in young females was highlighted by substantial variability in LMVF measures in response to the VC condition that was unrelated to changes in the potential contributors to sitting-induced reductions in LMVF (e.g. lower limb venous pooling, reduced arterial shear rate). NEW AND NOTEWORTHY: In this study, we employed an acute Vitamin C (VC) supplementation to examine sex differences in leg microvascular function (LMVF) following a bout of prolonged sitting. This study revealed that prolonged sitting reduced LMVF independent of sex, but only young males reported an attenuation to this lowered LMVF following VC supplementation. The young females revealed substantial variability in sitting-induced changes to LMVF that could not be explained by the potential contributors to sitting-induced reductions in LMVF (e.g. lower limb venous pooling, reduced arterial shear rate).


Assuntos
Antioxidantes/administração & dosagem , Ácido Ascórbico/administração & dosagem , Extremidade Inferior/irrigação sanguínea , Microcirculação/efeitos dos fármacos , Microvasos/efeitos dos fármacos , Postura Sentada , Adulto , Feminino , Humanos , Masculino , Microvasos/fisiopatologia , Distribuição Aleatória , Fatores Sexuais , Fatores de Tempo , Adulto Jovem
11.
J R Soc Interface ; 16(156): 20190069, 2019 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-31266416

RESUMO

The atrioventricular heart valve (AHV) leaflets have a complex microstructure composed of four distinct layers: atrialis, ventricularis, fibrosa and spongiosa. Specifically, the spongiosa layer is primarily proteoglycans and glycosaminoglycans (GAGs). Quantification of the GAGs' mechanical contribution to the overall leaflet function has been of recent focus for aortic valve leaflets, but this characterization has not been reported for the AHV leaflets. This study seeks to expand current GAG literature through novel mechanical characterizations of GAGs in AHV leaflets. For this characterization, mitral and tricuspid valve anterior leaflets (MVAL and TVAL, respectively) were: (i) tested by biaxial mechanical loading at varying loading ratios and by stress-relaxation procedures, (ii) enzymatically treated for removal of the GAGs and (iii) biaxially mechanically tested again under the same protocols as in step (i). Removal of the GAG contents from the leaflet was conducted using a 100 min enzyme treatment to achieve approximate 74.87% and 61.24% reductions of all GAGs from the MVAL and TVAL, respectively. Our main findings demonstrated that biaxial mechanical testing yielded a statistically significant difference in tissue extensibility after GAG removal and that stress-relaxation testing revealed a statistically significant smaller stress decay of the enzyme-treated tissue than untreated tissues. These novel findings illustrate the importance of GAGs in AHV leaflet behaviour, which can be employed to better inform heart valve therapeutics and computational models.


Assuntos
Valva Aórtica/metabolismo , Simulação por Computador , Glicosaminoglicanos/metabolismo , Modelos Cardiovasculares , Estresse Mecânico , Animais , Suínos
12.
Opt Express ; 20(1): A13-9, 2012 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-22379670

RESUMO

Heteroepitaxial ZnO transparent current spreading layers with low sheet resistances were deposited on GaN-based light emitting diodes using aqueous solution phase epitaxy at temperatures below 90°C. The performance of the LEDs was analyzed and compared to identical devices using electron-beam evaporated indium tin oxide transparent current spreading layers. White LEDs with ZnO layers provided high luminous efficacy­157 lm/W at 0.5A/cm2, and 84.8 lm/W at 35A/cm2, 24% and 50% higher, respectively, than devices with ITO layers. The improvement appears to be due to the enhanced current spreading and low optical absorption provided by the ZnO.


Assuntos
Iluminação/instrumentação , Semicondutores , Óxido de Zinco/química , Cor , Cristalização , Desenho de Equipamento , Análise de Falha de Equipamento , Soluções , Água/química
14.
Inorg Chem ; 44(5): 1588-600, 2005 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-15733002

RESUMO

Using either an ammoniacal route, the reaction between DyCl3, Na0, and HOR in liquid ammonia, or preferentially reacting Dy(N(SiMe3)2)3 with HOR in a solvent, we isolated a family of dysprosium alkoxides as [Dy(mu-ONep)2(ONep)]4 (1), (ONep)2Dy[(mu3-ONep)(mu-ONep)Dy(ONep)(THF)]2(mu-ONep) (2), (ONep)2Dy[(mu3-ONep)(mu-ONep)Dy(ONep)(py)]2(mu-ONep) (3), [Dy3(mu3-OBut)2(mu-OBut3(OBut)4(HOBut)2] (4), [Dy3(mu3-OBut)2(mu-OBut)3(OBut)4(THF)2] (5), [Dy3(mu3-OBut)2(mu-OBut)3(OBut)4(py)2] (6), (DMP)Dy(mu-DMP)4[Dy(DMP)2(NH3)]2 (7), [Dy(eta6-DMP)(DMP)2]2 (8), Dy(DMP)3(THF)3 (9), Dy(DMP)3(py)3 (10), Dy(DIP)3(NH3)2 (11), [Dy(eta6-DIP)(DIP)2]2 (12), Dy(DIP)3(THF)2 (13), Dy(DIP)3(py)3 (14), Dy(DBP)3(NH3) (15), Dy(DBP)3 (16), Dy(DBP)3(THF) (17), Dy(DBP)3(py)2 (18), [Dy(mu-TPS)(TPS2]2 (19), Dy(TPS)3(THF)3 (20), and Dy(TPS)3(py)3 (21), where ONep = OCH2CMe3, OBut) = OCMe3, DMP = OC6H3(Me)(2)-2,6, DIP = OC6H3(CHMe2)(2)-2,6, DBP = OC6H3(CMe3)(2)-2,6, TPS = OSi(C6H5)3, tol = toluene, THF = tetrahydrofuran, and py = pyridine. We were not able to obtain X-ray quality crystals of compounds 2, 8, and 9. The structures observed and data collected for the Dy compounds are consistent with those reported for its other congeners. A number of these precursors were used as Dy dopants in Pb(Zr0.3Ti0.7)O3 (PZT 30/70) thin films, with compound 12 yielding the highest-quality films. The resulting Pb0.94Dy0.04(Zr0.3Ti0.7)O3 [PDyZT (4/30/70)] had similar properties to PZT (30/70), but showed substantial resistance to polarization reversal fatigue.

15.
Proc Natl Acad Sci U S A ; 99(10): 7130-5, 2002 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-12011469

RESUMO

Acetaminophen has antipyretic and analgesic properties yet differs from the nonsteroidal antiinflammatory drugs and inhibitors of prostaglandin H synthase (PGHS)-2 by exhibiting little effect on platelets or inflammation. We find parallel selectivity at a cellular level; acetaminophen inhibits PGHS activity with an IC(50) of 4.3 microM in interleukin (IL)-1 alpha-stimulated human umbilical vein endothelial cells, in contrast with an IC(50) of 1,870 microM for the platelet, with 2 microM arachidonic acid as substrate. This difference is not caused by isoform selectivity, because acetaminophen inhibits purified ovine PGHS-1 and murine recombinant PGHS-2 equally. We explored the hypothesis that this difference in cellular responsiveness results from antagonism of the reductant action of acetaminophen on the PGHSs by cellular peroxides. Increasing the peroxide product of the PGHS-cyclooxygenase, prostaglandin G(2) (PGG(2)), by elevating the concentration of either enzyme or substrate reverses the inhibitory action of acetaminophen, as does the addition of PGG(2) itself. 12-Hydroperoxyeicosatetraenoic acid (0.3 microM), a major product of the platelet, completely reverses the action of acetaminophen on PGHS-1. Inhibition of PGHS activity by acetaminophen in human umbilical vein endothelial cells is abrogated by t-butyl hydroperoxide. Together these findings support the hypothesis that the clinical action of acetaminophen is mediated by inhibition of PGHS activity, and that hydroperoxide concentration contributes to its cellular selectivity.


Assuntos
Acetaminofen/farmacologia , Analgésicos não Narcóticos/farmacologia , Inibidores de Ciclo-Oxigenase/farmacologia , Prostaglandina-Endoperóxido Sintases/metabolismo , 6-Cetoprostaglandina F1 alfa/metabolismo , Ácido Araquidônico/farmacologia , Plaquetas/efeitos dos fármacos , Células Cultivadas , Ciclo-Oxigenase 1 , Inibidores das Enzimas do Citocromo P-450 , Sistema Enzimático do Citocromo P-450 , Dinoprostona/metabolismo , Relação Dose-Resposta a Droga , Endotélio Vascular/citologia , Humanos , Peróxido de Hidrogênio/farmacologia , Interleucina-1/farmacologia , Oxirredutases Intramoleculares/antagonistas & inibidores , Isoenzimas/metabolismo , Peroxidação de Lipídeos , Proteínas de Membrana , Prostaglandinas G/biossíntese , Especificidade por Substrato , Veias Umbilicais/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...