Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39122095

RESUMO

BACKGROUND AND PURPOSE: STereotactic Arrhythmia Radioablation (STAR) showed promising results in patients with refractory ventricular tachycardia (VT). However, clinical data is scarce and heterogeneous. The STOPSTORM.eu consortium was established to investigate and harmonize STAR in Europe. The primary goal of this benchmark study was to investigate current treatment planning practice within the STOPSTORM project as a baseline for future harmonization. METHODS: Planning target volumes (PTV) overlapping extra-cardiac organs-at-risk and/or cardiac substructures were generated for three STAR cases. Participating centers were asked to create single fraction treatment plans with 25 Gy dose prescription based on in-house clinical practice. All treatment plans were reviewed by an expert panel and quantitative crowd knowledge-based analysis was performed with independent software using descriptive statistics for ICRU report 91 relevant parameters and crowd dose-volume-histograms. Thereafter, treatment planning consensus statements were established using a dual-stage voting process. RESULTS: Twenty centers submitted 67 treatment plans for this study. In most plans (75%) Intensity Modulated Arc Therapy (IMAT) with 6 MV flattening-filter-free beams was used. Dose prescription was mainly based on PTV D95% (49%) or D96-100% (19%). Many participants preferred to spare close extra-cardiac organs-at-risk (75%) and cardiac substructures (50%) by PTV coverage reduction. PTV D0.035cm3 ranged 25.5-34.6 Gy, demonstrating a large variety of dose inhomogeneity. Estimated treatment times without motion compensation or setup ranged 2-80 minutes. For the consensus statements, strong agreement was reached for beam technique planning, dose calculation, prescription methods and trade-offs between target and extra-cardiac critical structures. No agreement was reached on cardiac substructure dose limitations and on desired dose inhomogeneity in the target. CONCLUSION: This STOPSTORM multi-center treatment planning benchmark study showed strong agreement on several aspects of STAR treatment planning, but also revealed disagreement on others. To standardize and harmonize STAR in the future, consensus statements were established, however clinical data is urgently needed for actionable guidelines for treatment planning.

2.
Phys Med ; 123: 103394, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38852364

RESUMO

PURPOSE: To present the results of the first multi-centre real-world validation of autoplanning for whole breast irradiation after breast-sparing surgery, encompassing high complexity cases (e.g. with a boost or regional lymph nodes) and a wide range of clinical practices. METHODS: The 24 participating centers each included 10 IMRT/VMAT/Tomotherapy patients, previously treated with a manually generated plan ('manplan'). There were no restrictions regarding case complexity, planning aims, plan evaluation parameters and criteria, fractionation, treatment planning system or treatment machine/technique. In addition to dosimetric comparisons of autoplans with manplans, blinded plan scoring/ranking was conducted by a clinician from the treating center. Autoplanning was performed using a single configuration for all patients in all centres. Deliverability was verified through measurements at delivery units. RESULTS: Target dosimetry showed comparability, while reductions in OAR dose parameters were 21.4 % for heart Dmean, 16.7 % for ipsilateral lung Dmean, and 101.9 %, 45.5 %, and 35.7 % for contralateral breast D0.03cc, D5% and Dmean, respectively (all p < 0.001). Among the 240 patients included, the clinicians preferred the autoplan for 119 patients, with manplans preferred for 96 cases (p = 0.01). Per centre there were on average 5.0 ± 2.9 (1SD) patients with a preferred autoplan (range [0-10]), compared to 4.0 ± 2.7 with a preferred manplan ([0,9]). No differences were observed regarding deliverability. CONCLUSION: The automation significantly reduced the hands-on planning workload compared to manual planning, while also achieving an overall superiority. However, fine-tuning of the autoplanning configuration prior to clinical implementation may be necessary in some centres to enhance clinicians' satisfaction with the generated autoplans.


Assuntos
Automação , Neoplasias da Mama , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Feminino , Radiometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...