Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(15)2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35957364

RESUMO

In computer-assisted surgery, it is typically required to detect when the tool comes into contact with the patient. In activated electrosurgery, this is known as the energy event. By continuously tracking the electrosurgical tools' location using a navigation system, energy events can help determine locations of sensor-classified tissues. Our objective was to detect the energy event and determine the settings of electrosurgical cautery-robustly and automatically based on sensor data. This study aims to demonstrate the feasibility of using the cautery state to detect surgical incisions, without disrupting the surgical workflow. We detected current changes in the wires of the cautery device and grounding pad using non-invasive current sensors and an oscilloscope. An open-source software was implemented to apply machine learning on sensor data to detect energy events and cautery settings. Our methods classified each cautery state at an average accuracy of 95.56% across different tissue types and energy level parameters altered by surgeons during an operation. Our results demonstrate the feasibility of automatically identifying energy events during surgical incisions, which could be an important safety feature in robotic and computer-integrated surgery. This study provides a key step towards locating tissue classifications during breast cancer operations and reducing the rate of positive margins.


Assuntos
Robótica , Ferida Cirúrgica , Mama , Cauterização , Eletrocirurgia , Humanos
2.
Med Phys ; 48(10): 5611-5623, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34415069

RESUMO

PURPOSE: In this study, we propose combining three-dimensional (3D) transrectal ultrasound (TRUS) and 3D transabdominal ultrasound (TAUS) images of gynecologic brachytherapy applicators to leverage the advantages of each imaging perspective, providing a broader field-of-view and allowing previously obscured features to be recovered. The aim of this study was to evaluate the feasibility of fusing these 3D ultrasound (US) perspectives based on the applicator geometry in a phantom prior to clinical implementation. METHODS: In proof-of-concept experiments, 3D US images of application-specific multimodality pelvic phantoms were acquired with tandem-and-ring and tandem-and-ovoids applicators using previously validated imaging systems. Two TRUS images were acquired at different insertion depths and manually fused based on the position of the ring/ovoids to broaden the TRUS field-of-view. The phantom design allowed "abdominal thickness" to be modified to represent different body habitus and TAUS images were acquired at three thicknesses for each applicator. The merged TRUS images were then combined with TAUS images by rigidly aligning applicator components and manually refining the registration using the positions of source channels and known tandem length, as well as the ring diameter for the tandem-and-ring applicator. Combined 3D US images were manually, rigidly registered to images from a second modality (magnetic resonance (MR) imaging for the tandem-and-ring applicator and X-ray computed tomography (CT) for the tandem-and-ovoids applicator (based on applicator compatibility)) to assess alignment. Four spherical fiducials were used to calculate target registration errors (TREs), providing a metric for validating registrations, where TREs were computed using root-mean-square distances to describe the alignment of manually identified corresponding fiducials. An analysis of variance (ANOVA) was used to identify statistically significant differences (p < 0.05) between the TREs for the three abdominal thicknesses for each applicator type. As an additional indicator of geometric accuracy, the bladder was segmented in the 3D US and corresponding MR/CT images, and volumetric differences and Dice similarity coefficients (DSCs) were calculated. RESULTS: For both applicator types, the combination of 3D TRUS with 3D TAUS images allowed image information obscured by the shadowing artifacts under single imaging perspectives to be recovered. For the tandem-and-ring applicator, the mean ± one standard deviation (SD) TREs from the images with increasing thicknesses were 1.37 ± 1.35 mm, 1.84 ± 1.22 mm, and 1.60 ± 1.00 mm. Similarly, for the tandem-and-ovoids applicator, the mean ± SD TREs from the images with increasing thicknesses were 1.37 ± 0.35 mm, 1.95 ± 0.90 mm, and 1.61 ± 0.76 mm. No statistically significant difference was detected in the TREs for the three thicknesses for either applicator type. The mean volume differences for the bladder segmentations were 3.14% and 2.33% and mean DSCs were 87.8% and 87.7% for the tandem-and-ring and tandem-and-ovoids applicators, respectively. CONCLUSIONS: In this proof-of-concept study, we demonstrated the feasibility of fusing 3D TRUS and 3D TAUS images based on the geometry of tandem-and-ring and tandem-and-ovoids applicators. This represents a step toward an accessible and low-cost 3D imaging method for gynecologic brachytherapy, with the potential to extend this approach to other intracavitary configurations and hybrid applicators.


Assuntos
Braquiterapia , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X , Ultrassonografia
3.
Brachytherapy ; 19(5): 659-668, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32631651

RESUMO

PURPOSE: The purpose of this study was to evaluate the use of a semiautomatic algorithm to simultaneously segment multiple high-dose-rate (HDR) gynecologic interstitial brachytherapy (ISBT) needles in three-dimensional (3D) transvaginal ultrasound (TVUS) images, with the aim of providing a clinically useful tool for intraoperative implant assessment. METHODS AND MATERIALS: A needle segmentation algorithm previously developed for HDR prostate brachytherapy was adapted and extended to 3D TVUS images from gynecologic ISBT patients with vaginal tumors. Two patients were used for refining/validating the modified algorithm and five patients (8-12 needles/patient) were reserved as an unseen test data set. The images were filtered to enhance needle edges, using intensity peaks to generate feature points, and leveraged the randomized 3D Hough transform to identify candidate needle trajectories. Algorithmic segmentations were compared against manual segmentations and calculated dwell positions were evaluated. RESULTS: All 50 test data set needles were successfully segmented with 96% of algorithmically segmented needles having angular differences <3° compared with manually segmented needles and the maximum Euclidean distance was <2.1 mm. The median distance between corresponding dwell positions was 0.77 mm with 86% of needles having maximum differences <3 mm. The mean segmentation time using the algorithm was <30 s/patient. CONCLUSIONS: We successfully segmented multiple needles simultaneously in intraoperative 3D TVUS images from gynecologic HDR-ISBT patients with vaginal tumors and demonstrated the robustness of the algorithmic approach to image artifacts. This method provided accurate segmentations within a clinically efficient timeframe, providing the potential to be translated into intraoperative clinical use for implant assessment.


Assuntos
Adenocarcinoma de Células Claras/radioterapia , Braquiterapia/métodos , Carcinoma Endometrioide/radioterapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias Vaginais/radioterapia , Adenocarcinoma de Células Claras/secundário , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Braquiterapia/instrumentação , Carcinoma Endometrioide/secundário , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/secundário , Neoplasias do Endométrio/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Agulhas , Neoplasias Ovarianas/patologia , Próstata/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador , Ultrassonografia/métodos , Neoplasias Vaginais/patologia , Neoplasias Vaginais/secundário
4.
J Med Imaging (Bellingham) ; 6(2): 025001, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30989088

RESUMO

Brachytherapy, a type of radiotherapy, may be used to place radioactive sources into or in close proximity to tumors, providing a method for conformally escalating dose in the tumor and the local area surrounding the malignancy. High-dose-rate interstitial brachytherapy of vaginal tumors requires precise placement of multiple needles through holes in a plastic perineal template to deliver treatment while optimizing dose and avoiding overexposure of nearby organs at risk (OARs). Despite the importance of needle placement, image guidance for adaptive, intraoperative needle visualization, allowing misdirected needles to be identified and corrected during insertion, is not standard practice. We have developed a 360-deg three-dimensional (3-D) transvaginal ultrasound (TVUS) system using a conventional probe with a template-compatible custom sonolucent vaginal cylinder and propose its use for intraoperative needle guidance during interstitial gynecologic brachytherapy. We describe the 3-D TVUS mechanism and geometric validation, present mock phantom procedure results, and report on needle localization accuracy in patients. For the six patients imaged, landmark anatomical features and all needles were clearly visible. The implementation of 360-deg 3-D TVUS through a sonolucent vaginal cylinder provides a technique for visualizing needles and OARs intraoperatively during interstitial gynecologic brachytherapy, enabling implants to be assessed and providing the potential for image guidance.

5.
Med Phys ; 44(5): 1899-1911, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28295403

RESUMO

PURPOSE: Treatment for gynecologic cancers, such as cervical, recurrent endometrial, and vaginal malignancies, commonly includes external-beam radiation and brachytherapy. In high-dose-rate (HDR) interstitial gynecologic brachytherapy, radiation treatment is delivered via hollow needles that are typically inserted through a template on the perineum with a cylinder placed in the vagina for stability. Despite the need for precise needle placement to minimize complications and provide optimal treatment, there is no standard intra-operative image-guidance for this procedure. While some image-guidance techniques have been proposed, including magnetic resonance (MR) imaging, X-ray computed tomography (CT), and two-dimensional (2D) transrectal ultrasound (TRUS), these techniques have not been widely adopted. In order to provide intra-operative needle visualization and localization during interstitial brachytherapy, we have developed a three-dimensional (3D) TRUS system. This study describes the 3D TRUS system and reports on the system validation and results from a proof-of-concept patient study. METHODS: To obtain a 3D TRUS image, the system rotates a conventional 2D endocavity transducer through 170 degrees in 12 s, reconstructing the 2D frames into a 3D image in real-time. The geometry of the reconstruction was validated using two geometric phantoms to ensure the accuracy of the linear measurements in each of the image coordinate directions and the volumetric accuracy of the system. An agar phantom including vaginal and rectal canals, as well as a model uterus and tumor, was designed and used to test the visualization and localization of the interstitial needles under idealized conditions by comparing the needles' positions between the 3D TRUS scan and a registered MR image. Five patients undergoing HDR interstitial gynecologic brachytherapy were imaged using the 3D TRUS system following the insertion of all needles. This image was manually, rigidly registered to the clinical postinsertion CT scan based on the vaginal cylinder of the needle template. The positions of the tips and the trajectory of the needle paths were compared between the modalities. RESULTS: The observed geometric errors of the system were ≤ 0.3 mm in each of the three coordinate planes of the 3D US image and the mean measured volumetric error was 0.10 cm3 . In the phantom study, the mean needle tip difference was 1.54 ± 0.71 mm and the mean trajectory difference was 0.94 ± 0.89 degrees (n = 14). In the in vivo study, a total of 73 needles were placed, of which 88% of needles were visible and 79% of tips were identifiable in the 3D TRUS images. Six of the nine needles that were not visible were due to shadowing artifacts created by the presence of the vaginal cylinder of the needle template. The mean distance between corresponding needle tips in the two modalities was 3.82 ± 1.86 mm and the mean trajectory difference was 3.04 ± 1.63 degrees for the five patients. CONCLUSIONS: In this proof-of-concept study, the 3D TRUS system allowed for localization of needles not obscured by shadowing artifacts, providing a method for visualizing needles intra-operatively during HDR interstitial brachytherapy of gynecologic cancers and providing the potential for 3D image-guidance.


Assuntos
Braquiterapia , Neoplasias dos Genitais Femininos/radioterapia , Agulhas , Feminino , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Vagina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...