Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Vasc Endovascular Surg ; 58(4): 414-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37966457

RESUMO

The management of Kommerell's Diverticulum (KD) has been evolving from open repair to a hybrid of open and endovascular repair. While there is no consensus regarding the optimal strategy, the need for less invasive treatment with less morbidity early recovery, and improved quality of life is a common goal for both the patient and the provider.


Assuntos
Divertículo , Procedimentos Cirúrgicos Robóticos , Humanos , Aorta Torácica/cirurgia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Divertículo/cirurgia , Artéria Subclávia/cirurgia
4.
Vasc Endovascular Surg ; 57(5): 504-512, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36689395

RESUMO

INTRODUCTION: The management of Kommerell's Diverticulum (KD) has evolved from open surgical resection and graft replacement of the aorta, to endovascular repair in asymptomatic patients due to its recognized possible sequelae - aortic rupture and dissection. Despite these technical advances, standard indications for intervention and treatment algorithms remain unclear. We will present our single-center experience in the treatment of KD, supporting a multidisciplinary endovascular-first approach. METHODS: All patients who underwent thoracic endovascular aortic repair (TEVAR) for KD between 2017 and 2020 were retrospectively identified from a prospectively maintained institutional surgery database. Chart review was used to characterize presenting symptoms, interventions, technical results, and complications. Revascularization was performed using carotid-axillary bypass. Routine endovascular subclavian artery occlusion was employed to eliminate retrograde diverticulum perfusion and avoid open ligation. RESULTS: 8 patients were identified, including 6 females and 2 males between the ages of 44-76. Patients presented with dysphagia (n = 3), acute embolic stroke (n = 1), transient ischemic attack (TIA) (n = 1), upper extremity embolization (n = 1), and acute type B aortic dissection (n = 1). One patient had a prior incomplete open repair that was successfully treated endovascularly. Another patient had a mediastinal neoplasm infiltrating an incidental aberrant subclavian artery and KD. All cases had symptomatic improvement and successful endovascular repair as demonstrated on post-operative imaging. Perioperative complications included percutaneous access site pseudoaneurysm (n = 2), stroke (n = 1), and subclavian artery rupture immediately recognized and treated (n = 1). There was no perioperative mortality. CONCLUSION: Endovascular techniques have resulted in technical success and symptomatic improvement for KD without open thoracotomy or sternotomy. Significant rates of endovascular complications and paucity of long-term durability data should be considered. Until formal criteria for repair are established, early application of TEVAR using a consistent multi-specialty approach may mitigate the risk of unpredictable aortic complications in these patients while avoiding the accepted morbidity and mortality of open surgery.


Assuntos
Aneurisma da Aorta Torácica , Divertículo , Procedimentos Endovasculares , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia , Artéria Subclávia/anormalidades , Estudos Retrospectivos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/anormalidades , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Divertículo/complicações , Divertículo/diagnóstico por imagem , Divertículo/cirurgia , Assistência Centrada no Paciente
6.
JACC Case Rep ; 4(9): 564-566, 2022 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-35573850

RESUMO

Pulmonary pseudoaneurysms have various causes and typically arise from the main pulmonary artery. Surgical and endovascular options may be considered for treatment. We report the case of a man with a pseudoaneurysm arising from the right pulmonary artery, treated with a septal occlusion device and percutaneous thrombin injection. (Level of Difficulty: Advanced.).

7.
Perfusion ; 37(5): 493-498, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33765891

RESUMO

BACKGROUND: The use of veno-arterial extracorporeal membrane oxygenation (VA ECMO) for cardiogenic shock in pregnant and postpartum patients remains limited by concerns of bleeding, hemolysis, and fetal risks. This case series examines the underlying characteristics and management strategies for this high-risk population. METHODS: All pregnant and post-partum patients who underwent VA ECMO in the cardiovascular intensive care unit between January 1, 2016 and November 1, 2019, were included in this retrospective study. Management of maternal and fetal O2 delivery, left ventricular (LV) unloading, anticoagulation, and ECMO circuit characteristics were evaluated. RESULTS: Five patients required veno-arterial ECMO for restoration of systemic perfusion. Three patients developed peripartum cardiomyopathy, one septic cardiomyopathy, and one acute right ventricular (RV) failure. The median age was 30.6 years, with median gestational age in pregnant patients of 31 weeks. Maternal and fetal survival to discharge was 80%. Bleeding was the primary complication, with two patients requiring blood transfusions; one requiring interventional radiology (IR) embolization and the other requiring surgical intervention to control bleeding. One patient was successfully delivered on VA ECMO. No fetal complications were directly attributed to VA ECMO. CONCLUSIONS: VA ECMO can be employed successfully in obstetric patients with cardiogenic shock with appropriate patient selection. Further research is needed to determine if VA ECMO provides a survival advantage over traditional management strategies in this vulnerable population.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Adulto , Oxigenação por Membrana Extracorpórea/efeitos adversos , Feminino , Insuficiência Cardíaca/complicações , Humanos , Lactente , Período Pós-Parto , Gravidez , Estudos Retrospectivos , Choque Cardiogênico
8.
J Endovasc Ther ; 29(3): 444-450, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34622700

RESUMO

Stanford Type A aortic dissections (TAAD) should be considered for repair, given the involvement of branch vessels which can result in malperfusion, specifically cerebral malperfusion secondary to dissection of the innominate and carotid arteries. This is a case report with a focus on four patients presenting with both acute and chronic symptomatic TAAD, with extension into the innominate and common carotid arteries. In all four cases, the decision to intervene utilizing a hybrid endovascular approach was made to increase perfusion to the brain and alleviate symptoms. Through the use of retrograde carotid stenting utilizing both the VICI venous stent (Boston Scientific, Marlborough, MA) and Abre self-expanding Nitinol stent (Medtronic, Minneapolis, MN) we obtained good results, specifically absence of symptoms and return to normal function of the patients.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Artéria Carótida Primitiva , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Stents , Resultado do Tratamento
9.
SLAS Technol ; 26(6): 591-604, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34219541

RESUMO

This review discusses the field of coprocytobiology, defined as a combined method of cell preservation, isolation, and cytology, which has applications to the investigation of noninvasive fecal screening for colorectal cancer. In the decade since the field was last reviewed, cell isolation has progressed rapidly via the development of technologies such as microfluidic and magnetic cell sorting. The landscape of cytology has also advanced in this time with the emergence of novel cytological methods and cell preservation strategies. Previous reviews present an outdated and incomplete view of coprocytobiology, summarizing a limited number of early publications, ignoring the principle of cell preservation and focusing on a single method of isolation rather than the field as a whole. In contrast to these publications, this review presents an updated, comprehensive, and unbiased representation of the technical aspects of coprocytobiology and provides unique insight into the common methodological pitfalls, best practice, and future directions of cytological screening for colorectal cancer.This review discusses the field of coprocytobiology, defined as a combined method of cell preservation, isolation, and cytology, which has applications to the investigation of noninvasive fecal screening for colorectal cancer. In the decade since the field was last reviewed, cell isolation has progressed rapidly via the development of technologies such as microfluidic and magnetic cell sorting. The landscape of cytology has also advanced in this time with the emergence of novel cytological methods and cell preservation strategies. Previous reviews present an outdated and incomplete view of coprocytobiology, summarizing a limited number of early publications, ignoring the principle of cell preservation and focusing on a single method of isolation rather than the field as a whole. In contrast to these publications, this review presents an updated, comprehensive, and unbiased representation of the technical aspects of coprocytobiology and provides unique insight into the common methodological pitfalls, best practice, and future directions of cytological screening for colorectal cancer.


Assuntos
Neoplasias Colorretais , Detecção Precoce de Câncer , Neoplasias Colorretais/diagnóstico , Fezes , Humanos , Programas de Rastreamento
10.
IEEE Access ; 9: 49912-49919, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33996343

RESUMO

Pixelated semi-conductor detectors providing high energy resolution enable parallel acquisition of x-ray fluorescence (XRF) signals, potentially leading to performance enhancement of benchtop XRF imaging or computed tomography (XFCT) systems utilizing ordinary polychromatic x-ray sources. However, little is currently known about the characteristics of such detectors under typical operating conditions of benchtop XRF imaging/XFCT. In this work, a commercially available pixelated cadmium telluride (CdTe) detector system, HEXITEC (High Energy X-ray Imaging Technology), was characterized to address this issue. Specifically, HEXITEC was deployed into our benchtop cone-beam XFCT system, and used to detect gold Kα XRF photons from gold nanoparticle (GNP)-loaded phantoms. To facilitate the detection of XRF photons, various parallel-hole stainless steel collimators were fabricated and coupled with HEXITEC. A pixel-by-pixel spectrum merging algorithm was introduced to obtain well-defined XRF + scatter spectra with parallel-hole collimators. The effect of charge sharing addition (CSA) and discrimination (CSD) algorithms was also investigated for pixel-level CS correction. Finally, the detector energy resolution, in terms of the full-width at half-maximum (FWHM) values at two gold Kα XRF peaks (~68 keV), was also determined. Under the current experimental conditions, CSD provided the best energy resolution of HEXITEC (~1.05 keV FWHM), compared with CSA and no CS correction. This FWHM value was larger (by up to ~0.35 keV) than those reported previously for HEXITEC (at ~60 keV Am-241 peak) and single-crystal CdTe detectors (at two gold Kα XRF peaks). This investigation highlighted characteristics of HEXITEC as well as the necessity for application-specific detector characterization.

11.
Vasc Endovascular Surg ; 55(3): 265-268, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33357042

RESUMO

INTRODUCTION: Thoracic Endovascular Aortic Repair (TEVAR) has become the procedure of choice for pathology involving the descending thoracic aorta since its approval by the FDA in 2005. Left subclavian artery (LSA) coverage is commonly required to facilitate an adequate proximal landing zone for the endograft. The traditional revascularization procedure of choice is carotid-subclavian bypass, however recent studies report complication rates as high as 29%-specifically phrenic nerve palsy in 25% of patients undergoing this procedure. Our aim is to present our experience using carotid-axillary bypass as a safe alternative to carotid-subclavian bypass. METHODS: All patients undergoing carotid-axillary bypass for TEVAR with LSA coverage between June 2016 and September 2019 at a tertiary medical center were retrospectively identified. Short-term and long-term complications were identified and analyzed including: phrenic nerve, recurrent laryngeal nerve, and axillary nerve injuries, as well as local vascular complications requiring re-intervention. All perioperative chest radiographs were reviewed for new hemidiaphragm elevation to assess for phrenic nerve injuries. RESULTS: 35 patients underwent carotid-axillary bypass in conjunction with TEVAR during this time period. The majority of bypasses were performed concurrently with TEVAR (80.0%, 28/35) utilizing GORE PROPATEN 8 mm externally supported vascular graft (91.4%, 32/35). The complication rate specific to carotid-axillary bypass was 14.3% (5/35). We observed a significantly lower (0%, 0/35, P < 0.01) rate of phrenic nerve palsy for carotid-axillary bypass compared to the previously reported 25% (27/107) for carotid-subclavian bypass. For patients with available follow-up imaging (85.7%, 30/35), there was a 100% patency rate at time intervals ranging from 0-1066 days (IQR = 3-37.8). CONCLUSION: Carotid-axillary bypass can be performed as a safe alternative to carotid-subclavian bypass for LSA coverage during TEVAR involving a more superficial anatomic course of dissection. Phrenic nerve palsy, a well-described complication of the traditional carotid-subclavian bypass, was not observed in this retrospective series.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Artéria Axilar/cirurgia , Implante de Prótese Vascular , Artérias Carótidas/cirurgia , Procedimentos Endovasculares , Artéria Subclávia/cirurgia , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Artéria Axilar/diagnóstico por imagem , Artéria Axilar/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
12.
Vascular ; 29(4): 610-615, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33148138

RESUMO

OBJECTIVES: Trans-catheter aortic valve replacement is a commonplace procedure for patients with aortic valvular stenosis who are at a high risk for surgery, evidenced by the 34,892 trans-catheter aortic valve replacements performed in 2016. Trans-catheter aortic valve replacement's rate of major vascular complications with second-generation closure devices is 4.5% according to a meta-analysis of 10,822 patients. To manage those complications, percutaneous approaches to arterial repairs show shorter length of stay, higher rate of direct to home discharge and equivalent outcomes at long-term follow-up. This study's goal is to show that one center's vascular access strategy can decrease open repairs and improve patient outcomes. METHODS: Our team began accessing the mid-common femoral artery at least 1-2 cm proximal to the takeoff of the profunda femoris. This allowed an endovascular stent to be deployed if necessary via contralateral femoral access. We performed a completion angiogram following every trans-catheter aortic valve replacement to ensure no arterial complications. We conducted a retrospective review of a prospectively maintained database for all trans-catheter aortic valve replacement cases at a tertiary care center from 1 January 2016 to 30 June 2018. RESULTS: A total of 699 trans-catheter aortic valve replacement procedures were performed with 25/31 (80.6%) cases met inclusion criteria. An increase was noted in the number of stent procedures versus cutdown procedures over time (P < 0.001). A decrease was noted in the number of vascular surgery team activations following trans-catheter aortic valve replacement (P = 0.004). A non-significant trend was noted toward a shorter median length of stay for the stent group (P = 0.149). There was no increase in 30-day mortality rate (0.0% for both groups) or 30-day readmissions (4/15 (26.7%) for stents vs. 2/10 (20.0%) for open repairs; P > 0.999). CONCLUSIONS: This strategy is safe and feasible to implement and reduces the number of open repairs following trans-catheter aortic valve replacement, activation of surgical resources, and possibly the length of stay.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/instrumentação , Procedimentos Endovasculares , Artéria Femoral , Substituição da Valva Aórtica Transcateter , Dispositivos de Acesso Vascular , Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Desenho de Equipamento , Artéria Femoral/diagnóstico por imagem , Próteses Valvulares Cardíacas , Humanos , Punções , Estudos Retrospectivos , Stents , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
13.
JTCVS Tech ; 10: 322-330, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34977748

RESUMO

BACKGROUND: Arteriotomy repair through the preclosure technique during elective arterial access procedures is well documented. Outcomes associated with application of this technique to the removal of arterial access cannulas in patients undergoing urgent venoarterial extracorporeal membrane oxygenation (VA-ECMO) have not previously been reported. METHODS: We reviewed the records of consecutive patients who required VA-ECMO for cardiogenic shock. Patients were compared by use of the preclosure device (Perclose ProGlide Suture-Mediated Closure System; Abbott Vascular, Abbott Park, Ill) at time of VA-ECMO cannulation. The rate of limb complications (composite of limb ischemia, infection, and site necrosis) and secondary end points of bleeding events, pseudoaneurysm, distal part embolization, and intensive care unit length of stay after decannulation were compared between the groups. RESULTS: Ninety-nine consecutive patients managed with VA-ECMO were identified and the preclosure device was utilized in 51 of these patients. Preclosure device failure occurred in 5 instances (9.8%) and was successfully managed with surgical repair in 4 cases and endovascular intervention in another. Use of the preclosure device was associated with both fewer limb complications (odds ratio, 0.19; 95% confidence interval, 0.03-0.78) and bleeding events (odds ratio, 0.21; 95% confidence interval, 0.04-0.89). Pseudoaneurysm (n = 0) and distal part embolization (n = 1) were infrequently encountered in the cohort and no difference in intensive care unit length of stay after decannulation was noted between the groups. CONCLUSIONS: In this cohort, use of the preclosure technique in weaning from VA-ECMO was technically feasible, safe, and associated with an approximate 80% lower likelihood of limb complications and bleeding events compared with surgical removal.

14.
Musculoskelet Sci Pract ; 51: 102281, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33161307

RESUMO

BACKGROUND: Current clinical practice guidelines for degenerative meniscal tears recommend conservative management yet patients are frequently referred to the consultant orthopaedic surgeon despite a lack of evidence for the use of arthroscopy. OBJECTIVES: To explore the beliefs about their condition and treatment expectations of patients referred to a secondary care orthopaedic clinic with a degenerative meniscal tear. DESIGN AND METHODS: Design and MethodsThis qualitative study involved ten patients who participated in semi-structured telephone interviews. Data were subjected to thematic analysis and findings were reported in accordance with the Consolidated Criteria for Reporting Qualitative Studies. RESULTS: Analysis identified five themes. Participants described beliefs, strongly influenced by magnetic resonance imaging (MRI) results, that damaged structures were causing their knee problems ("The meniscus is busted"), and expected their knee problems to inevitably worsen over time ("It's only going to get worse"). Participants were hopeful the orthopaedic consultation would clarify their problem and lead to a subsequent definitive intervention ("Hopefully they will give me answers"). Most participants viewed surgery as "the quick and straightforward solution" necessary to repair faulty cartilage. Exercise was not seen as compatible with the recovery process by most ("Would I make it worse?"). CONCLUSIONS: How participants understand their knee problem contributes to surgical expectations and perceptions that it is not amenable to conservative management. Findings suggest a need to educate both patients and primary care clinicians about the safety and efficacy of exercise as first-line therapy for degenerative meniscal tears. The negative role of MRI in promoting surgical expectations needs further consideration.


Assuntos
Traumatismos do Joelho , Lesões do Menisco Tibial , Artroscopia , Humanos , Traumatismos do Joelho/terapia , Motivação , Atenção Secundária à Saúde , Lesões do Menisco Tibial/cirurgia
15.
Vasc Endovascular Surg ; 55(3): 290-294, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33054602

RESUMO

Symptomatic aneurysms of the innominate and subclavian arteries are rare and pose unique challenges for endovascular repair particularly in a patient with a "bovine" arch. Previous publications have described back table modifications of standard iliac endografts to conform to the innominate artery for exclusion of the lesion. Others have proposed extra-anatomic bypass or carotid-subclavian transposition with occlusion of the innominate artery. We were unable to find a report of repair when aneurysms of the innominate and subclavian arteries were in continuity. We present such a case of endovascular repair using commercially available endografts without compromise of the left common carotid artery origin as this patient had a "bovine" arch. Surgeons will benefit from adding this endovascular option to their "tool box" when confronted with such a challenging clinical scenario.


Assuntos
Aneurisma/cirurgia , Aorta Torácica/anormalidades , Implante de Prótese Vascular , Tronco Braquiocefálico/cirurgia , Procedimentos Endovasculares , Artéria Subclávia/cirurgia , Adulto , Aneurisma/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Tronco Braquiocefálico/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Artéria Subclávia/diagnóstico por imagem , Resultado do Tratamento
16.
Cardiovasc Revasc Med ; 21(9): 1065-1073, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31974033

RESUMO

OBJECTIVES: To determine the incidence, prognosis, and predictors of major Valve Academic Research Consortium (VARC-2) vascular complications (VCs) and percutaneous vascular closure device failure (PCDF) following contemporary percutaneous transfemoral transcatheter aortic valve replacement (TF-TAVR). BACKGROUND: Limited data exists on the incidence and predictors of VCs and PCDFs following percutaneous TF-TAVR using contemporary 14-16 French (F) sheaths. METHODS: We recorded clinical and procedural characteristics, computer tomography (CT) angiographic data, 30-day VCs, mortality, and length of stay (LOS) in all consecutive percutaneous TF-TAVRs at a single center from June 2016 to October 2018. CT measures included common femoral artery (CFA) and external iliac artery (EIA) diameters, sheath to CFA and EIA ratios (SFAR and SEIAR), depth of CFA, extent and location of CFA calcification and pelvic vessel tortuosity (2 bends ≥90°). Multivariable regression was used to predict major VCs and percutaneous closure device failure (PCDF), respectively. RESULTS: The final sample consisted of 303 percutaneous TF-TAVRs. Median age was 80 years, 51% were male, 86% Caucasian, 33% had diabetes mellitus (DM) and mean STS score was 5.8 ±â€¯3.8%. Baseline characteristics were similar in patients with vs. without VCs, other than coronary artery disease (CAD) (69% vs. 54%, respectively; p = 0.029) and DM (21% vs. 36%, respectively; p = 0.02). There were 65 (21%) vascular complications: 19 major VCs [6.3%], 29 minor [VCs 9.6%] and 17 PCDFs [5.6%]. Overall, 30-day mortality was low (2.6%). Major VCs were associated with higher mortality (42% vs. 0%, p < 0.0001) while minor VCs (3% vs. 0%, mortality p = 0.99) and PCDFs (3% vs. 0% mortality, p = 0.99) were not. PCDFs were associated with a longer median LOS (4 vs. 3 days, p = 0.02). The independent predictors of major VCs were pelvic vessel tortuosity (OR 3.1; 95% CI 1.1-9.2) and presence of CAD (OR 8.2; 95% CI 1.8-37). Female gender showed a strong trend toward increased risk (OR 3.4; CI 0.84-14; p = 0.086). There were no independent predictors of PCDF. CONCLUSION: Contemporary percutaneous TF-TAVR is associated with a low risk of mortality, major VCs and PCDFs. Major VCs confer increased mortality and PCDFs prolong LOS. Pelvic vessel tortuosity and a history of CAD predict major VCs; there were no predictors of PCDFs. These results provide a contemporary update on the incidence and implications of these important vascular complications in the current era of percutaneous TF-TAVR using 14-16F vascular sheaths.


Assuntos
Estenose da Valva Aórtica , Falha de Equipamento , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Artéria Femoral/cirurgia , Humanos , Incidência , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
17.
JACC Cardiovasc Interv ; 13(2): 210-216, 2020 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-31883715

RESUMO

OBJECTIVES: The aim of this study was to report the 1-year results of transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. BACKGROUND: Favorable 30-day outcomes of S3 TAVR in annuli >683 mm2 have previously been reported. Pacemaker implantation rates were acceptable, and a larger left ventricular outflow tract and more eccentric annular anatomy were associated with increasing paravalvular leak. METHODS: From December 2013 to December 2018, 105 patients across 15 centers with mean area 721.3 ± 36.1 mm2 (range 683.5 to 852.0 mm2) underwent TAVR using an S3 device. Clinical, anatomic, and procedural characteristics were analyzed. One-year survival and echocardiographic follow-up were reached in 94.3% and 82.1% of patients, respectively. Valve Academic Research Consortium-2 30-day and 1-year outcomes were reported. RESULTS: The mean age was 76.9 ± 10.4 years, and Society of Thoracic Surgeons predicted risk score averaged 5.2 ± 3.4%. One-year overall mortality and stroke rates were 18.2% and 2.4%, respectively. Quality-of-life index improved from baseline to 30 days and at 1 year (p < 0.001 for both). Mild paravalvular aortic regurgitation occurred in 21.7% of patients, while moderate or greater paravalvular aortic regurgitation occurred in 4.3%. Mild and moderate or severe transvalvular aortic regurgitation occurred in 11.6% and 0%, respectively. Valve gradients remained stable at 1 year. CONCLUSIONS: S3 TAVR in annular areas >683 mm2 is feasible, with favorable mid-term outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , América do Norte , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
18.
J Vasc Surg Cases Innov Tech ; 5(4): 431-434, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31660466

RESUMO

Acute mesenteric ischemia secondary to aortic dissection in type A and type B is a true vascular surgical emergency. Presentation can be subtle or dramatic, and time to revascularization is limited before irreversible changes occur. The literature recognizes the catastrophic consequences of acute superior mesenteric artery occlusion and the need for urgent revascularization, often before central aortic repair in type A. There is no optimal revascularization technique described in this scenario. We present a case of type A aortic dissection with acute dynamic and static superior mesenteric artery occlusion and describe treatment that resulted in successful salvage of the bowel and the patient's life.

19.
J Vasc Surg Cases Innov Tech ; 4(4): 278-282, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30547146

RESUMO

Open technique for elective repair of iliac artery aneurysms can be safely performed with good outcomes but not inconsequential morbidity. An endovascular approach has been shown to have both periprocedural and postoperative advantages with equivalent outcomes. Endovascular repair of common iliac arteries (CIAs) without sacrificing the hypogastric artery using an iliac branch device is a complex endovascular technique requiring a proximal seal zone that may be absent in larger CIA aneurysms. We present two cases in which CIA aneurysms were repaired with a customized endovascular technique using the benefit of the aortic bifurcation for stability in addition to providing a long proximal seal zone with the AFX device (Endologix, Irvine, Calif) paired with the iliac branch device (W. L. Gore & Associates, Flagstaff, Ariz) for internal iliac artery preservation.

20.
Cardiovasc Revasc Med ; 19(8S): 31-34, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29970329

RESUMO

We describe the first case of an endovascular repair for a pseudoaneurysm of the ascending aorta using the Valiant Navion EVO® low-profile thoracic endograft from Medtronic™. A successful outcome from a potentially fatal condition in a severely compromised patient was achieved.


Assuntos
Falso Aneurisma/cirurgia , Aorta/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Stents , Falso Aneurisma/diagnóstico , Aorta/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Aortografia , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...