Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
JMIR Cardio ; 8: e42402, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38635975

RESUMO

BACKGROUND: Mediated diet and exercise methods yield effective short-term weight loss but are costly and hard to manage. However, web-based programs can serve many participants, offering ease of access and cost-efficiency. OBJECTIVE: This study aimed to compare the effectiveness of a web-based weight management program through web-based education alone (MINE) or combined with tailored video feedback (MINE Plus) with a control (CO) group. METHODS: This intervention included 60 Korean women with overweight and obesity (BMI≥23 kg/m2) aged 19 years to 39 years old. We randomly allocated 60 participants to each of 3 groups: (1) MINE group (web-based education video and self-monitoring app), (2) MINE Plus group (web-based education video, self-monitoring app, and 1:1 tailored video feedback), and (3) CO group (only self-monitoring app). Web-based education included nutrition, physical activity, psychological factors, medical knowledge for weight loss, goal setting, and cognitive and behavioral strategies. Tailored feedback aimed to motivate and provide solutions via weekly 10-minute real-time video sessions. The intervention lasted 6 weeks, followed by a 6-week observation period to assess the education's lasting effects, with evaluations at baseline, 6 weeks, and 12 weeks. A generalized linear mixed model was used to evaluate time and group interactions. RESULTS: In the intention-to-treat analysis including all 60 participants, there were significant differences in weight change at 6 weeks in the MINE and MINE Plus groups, with mean weight changes of -0.74 (SD 1.96) kg (P=.03) and -1.87 (SD 1.8) kg (P<.001), respectively, while no significant change was observed in the CO group, who had a mean weight increase of 0.03 (SD 1.68) kg (P=.91). After 12 weeks, changes in body weight were -1.65 (SD 2.64) kg in the MINE group, -1.59 (SD 2.79) kg in the MINE Plus group, and 0.43 (SD 1.42) kg in the CO group. There was a significant difference between the MINE and MINE Plus groups (P<.001). Significant group × time effects were found for body weight in the MINE and CO groups (P<.001) and in the MINE Plus and CO groups (P<.001), comparing baseline and 12 weeks. Regarding physical activity and psychological factors, only body shape satisfaction and health self-efficacy were associated with improvements in the MINE and MINE Plus groups (P<.001). CONCLUSIONS: This study found that the group receiving education and tailored feedback showed significant weight loss and improvements in several psychological factors, though there were differences in the sustainability of the effects. TRIAL REGISTRATION: Korea Disease Control and Prevention Agency (KDCA) KCT0007780: https://cris.nih.go.kr/cris/search/detailSearch.do/22861.

2.
Metabolites ; 12(12)2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36557294

RESUMO

The baseline distortion caused by water and fat signals is a crucial issue in the 1H MRS(I) study of the human brain. This paper suggests an effective and reliable preprocessing technique to calibrate the baseline distortion caused by the water and fat signals exhibited in the MRS spectral signal. For the preprocessing, we designed a T2* (or linewidth within the spectral signal) selective filter for the MRS(I) data based on differential filtering within the frequency domain. The number and types for the differential filtering were determined by comparing the T2* selectivity profile of each differential operator with the T2* profile of the metabolites to be suppressed within the MRS(I) data. In the performance evaluation of the proposed differential filtering, the simulation data for MRS spectral signals were used. Furthermore, the spectral signal of the human 1H MRSI data obtained by 2D free induction decay chemical shift imaging with a typical water suppression technique was also used in the performance evaluation. The absolute values of the average of the filtered dataset were quantitatively analyzed using the LCModel software. With the suggested T2* selective (not frequency selective) filtering technique, in the simulated MRS data, we removed the metabolites from the simulated MRS(I) spectral signal baseline distorted by the water and fat signal observed in the most frequency band. Moreover, in the obtained MRSI data, the quantitative analysis results for the metabolites of interest showed notable improvement in the uncertainty estimation accuracy, the CRLB (Cramer-Rao Lower Bound) levels.

3.
Artigo em Inglês | MEDLINE | ID: mdl-35564610

RESUMO

The current study aimed to examine the adherence trend for aerobic and muscle-strengthening physical activity (PA) guidelines among Korean adults using the Korea National Health and Nutritional Examination Survey from 2014 to 2019. Korean adults (N = 2642) were included in the current study to examine the trend of PA adherence from 2014 to 2019. The PA guidelines are: (a) aerobic activity (a minimum of 150 min moderate to vigorous PA weekly) and (b) muscle-strengthening activity (a minimum of two days weekly). Self-report questionnaires in the survey measured both activities. The adherence to PA guidelines by survey year was examined using a multivariable logistic regression analysis adjusted for covariates. There was a significant decreasing trend in which the adherence rate to aerobic PA guidelines changed from 57.0% in 2014 to 45.6% in 2019 (p < 0.001). On the other hand, the trend in adherence rate to muscle-strengthening activity was not significant (p = 0.976). The adherence rate to muscle-strengthening activity guideline was slightly increased but still low from 20.8% to 23.3% during 2014−2019. The aerobic PA guidelines are significantly decreasing, and more than half of the Korean adults in 2019 have not followed the guidelines. In addition, there has been a slight increase in muscle-strengthening activity; however, the adherence rate is meager. Therefore, this study suggests that Korean adults' aerobic and muscle-strengthening PA participation is necessary for their low adherence rate and decline tendency.


Assuntos
Exercício Físico , Músculos , Adulto , Humanos , Inquéritos Nutricionais , República da Coreia , Autorrelato
4.
Epidemiol Health ; 43: e2021056, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34412444

RESUMO

OBJECTIVES: The aim of this study was to identify the stepping cadence patterns in Korean adults by using objectively measured accelerometer data to analyze the time spent in each cadence category by sex and age. METHODS: During the 2014-2015 Korean National Health and Nutrition Examination Survey, 1,703 males and females aged 19-64 years provided at least 1 valid day of data (wearing an accelerometer ≥ 10 hr/d). The mean cumulative time and percentage per day in 8 cadence categories (0, 1-19, 20-29, 30-59, 60-79, 80-99, 100-119, and ≥ 120 steps/min) by sex and age group were calculated. RESULTS: Cumulative time and percentage per day decreased across the incremental cadence categories. Participants spent 360.08± 2.56 min/d in the non-movement cadence category and 361.50± 2.28 min/d in the incidental movement cadence category. However, they spent only about 18.1 min/d (2.1%) at ≥ 100 steps/min. Males spent significantly more time in the cadence categories of sporadic movement, purposeful steps, slow walking, and medium walking, but the other categories, except for brisk walking, had higher values in females (p< 0.001). The older age group spent less time in non-movement cadence categories, and the youngest and oldest groups spent more time at a higher cadence (≥ 100 steps/min) than the other age groups. Similar patterns were found in a subgroup analysis by sex. CONCLUSIONS: Korean adults spent most of their time at a low cadence and only a few minutes at a high cadence (≥100 steps/min); this trend was consistent across sex and age groups.


Assuntos
Marcha , Caminhada , Acelerometria , Adulto , Idoso , Feminino , Humanos , Masculino , Inquéritos Nutricionais , República da Coreia/epidemiologia
5.
PLoS One ; 14(7): e0219407, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31276549

RESUMO

The neuroimaging of humans using 7T magnetic resonance imaging (MRI) has been conducted using phased array (PA) coils with different numbers of receiving channels. PA coils with a high number of channels may offer parallel imaging (PI) with a high reduction (R)-factor, which is enabled via under-sampling and coil geometry (g) factor, increasing the radiofrequency signal sensitivity provided by a small coil. The goals of this study were to assess and validate the coil performance of PA coils with different numbers of receiver (Rx)-channels in and to propose the coil selection guidelines by visualizing 7T brain images. The combined magnetic flux density (||B1||) distributions of four configurations of PA coils-4-, 8-, 12-, and 16-channel Rx-only mode under the local transmit (Tx) mode of birdcage coils-were evaluated using electromagnetic (EM) calculations. These four configurations of PA coils and a local Tx coil were designed and built for a 7T MRI experiment. For 7T brain imaging experiments, all PA coils with (w/) and without (w/o) R-factors were compared in terms of signal-to-noise ratio (SNR) and spatial noise variation (SNV). EM simulation results clearly demonstrated that PA coils with a high number of Rx channels showed more homogeneously distributed ||B1|| fields than a PA coils with a low number of Rx coils. The results of this study demonstrate that a collection of smaller surface coils can contribute to high RF signal sensitivity in terms of the anatomical coverage of the brain and may facilitate PI. With further improvement in coil technology, researchers and clinicians will be provided with PA coils with different numbers of channels, which can ensure the optimum SNR and PI benefits for 7T brain MR imaging.


Assuntos
Imageamento por Ressonância Magnética , Modelos Teóricos , Neuroimagem , Razão Sinal-Ruído , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Neuroimagem/métodos , Neuroimagem/normas
6.
Magn Reson Med ; 71(5): 1923-31, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23804188

RESUMO

PURPOSE: To compare numerically simulated and experimentally measured temperature increase due to specific energy absorption rate from radiofrequency fields. METHODS: Temperature increase induced in both a phantom and in the human forearm when driving an adjacent circular surface coil was mapped using the proton resonance frequency shift technique of magnetic resonance thermography. The phantom and forearm were also modeled from magnetic resonance image data, and both specific energy absorption rate and temperature change as induced by the same coil were simulated numerically. RESULTS: The simulated and measured temperature increase distributions were generally in good agreement for the phantom. The relative distributions for the human forearm were very similar, with the simulations giving maximum temperature increase about 25% higher than measured. CONCLUSION: Although a number of parameters and uncertainties are involved, it should be possible to use numerical simulations to produce reasonably accurate and conservative estimates of temperature distribution to ensure safety in magnetic resonance imaging. R01 EB006563


Assuntos
Absorção de Radiação , Temperatura Corporal/fisiologia , Antebraço/fisiologia , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Temperatura Corporal/efeitos da radiação , Simulação por Computador , Antebraço/efeitos da radiação , Humanos , Temperatura , Termografia/métodos
7.
J Magn Reson Imaging ; 38(2): 435-40, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23293090

RESUMO

PURPOSE: To investigate the use of a new high-dielectric constant (HDC) material for improving SNR and transmission efficiency for clinical MRI applications at 3 Tesla (T) with cervical spine imaging. MATERIALS AND METHODS: Human subjects were imaged using a commercial cervical spine receive array coil on a clinical system with and without pads containing Barium Titanate beads in deuterium water placed around the neck. Numerical electromagnetic field simulations of the same configuration were also performed. RESULTS: Experimental and simulated maps of transmit and receive fields showed greater efficiency for imaging the cervical spine when the pads were present. Experimental measurements showed a significant improvement in SNR with the pads present and an average input power reduction of 46%. CONCLUSION: Use of HDC material can enhance SNR and transmission efficiency for clinical imaging of the cervical spine at 3.0T.


Assuntos
Vértebras Cervicais/anatomia & histologia , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Ondas de Rádio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Artigo em Inglês | MEDLINE | ID: mdl-22611340

RESUMO

We present a quadrature volume coil designed for brain imaging of a macaque monkey fixed in a sphinx position (facing down the bore) within a stereotactic frame at 3 T, where the position of the monkey and presence of the frame preclude use of existing coils. Requirements include the ability to position and remove the coil without disturbing the position of the monkey in the frame. A saddle coil and a solenoid were combined on a modified cylindrical former and connected in quadrature as to produce a homogeneous circularly polarized field throughout the brain. To allow the loops of the saddle coil to encompass the ear posts, partial disassembly and reassembly were facilitated by embedding pin and socket contacts into separate pieces of the former. Coil design included simulation of the electromagnetic fields for the coil containing a 3D model of a monkey's head. The resulting coil produced adequate homogeneity and signal-to-noise ratio throughout the brain.

9.
Neurosci Lett ; 343(1): 49-52, 2003 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-12749995

RESUMO

Maternal separation (MS) is a risk factor in the development of mood-related disorders such as depression. Human and animal studies support the involvement of neuropeptide Y (NPY) in the pathology of depression. To investigate the effect of acupuncture on depression-like behavior and examine changes in NPY expression associated with MS, we observed body weight and locomotor activity, and performed NPY immunohistochemistry in the hippocampus. MS for 7 days beginning on postnatal day 14 induced a significant decrease in body weight and locomotion, while acupuncture treatment at acupoint Shenmen (HT7) resulted in a significant increase in both. NPY-immunoreactive cells in area CA1 and the dentate gyrus were decreased in the MS group, but significantly increased in the acupuncture group. These findings suggest that acupuncture has an effect on the depression-like disorder caused by MS, possibly by modulating NPY expression in the hippocampus.


Assuntos
Acupuntura/métodos , Depressão/fisiopatologia , Hipocampo/fisiopatologia , Privação Materna , Neuropeptídeo Y/biossíntese , Animais , Peso Corporal , Depressão/metabolismo , Depressão/terapia , Hipocampo/metabolismo , Atividade Motora , Neurônios/metabolismo , Ratos , Ratos Sprague-Dawley , Valores de Referência , Estresse Fisiológico/metabolismo , Estresse Fisiológico/terapia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...