Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Eur J Pharm Biopharm ; 197: 114237, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38408710

RESUMO

Antler removal in deer is a common practice for various purposes, including meat production and traditional medicine. However, the current industry practice using lidocaine as a local anesthetic has limitations, such as short duration of action and the potential for postoperative infections. In this study, we investigated the performance of a ZnO collagen nanocomposites loaded with local anesthetics to improve wound management and alleviate pain associated with antler removal in red deer. The research involved the preparation of collagen nanocomposites with local anesthetics and testing the drug release rates using in vitro drug release tests. Pharmacokinetic analysis was performed to evaluate the total drug release from the collagen matrix in red deer after velvet removal. Additionally, the analgesic efficacy of these collagen nanocomposite dressings was assessed after antler removal in red deer. Functionalized ZnO nanoparticles were incorporated into collagen fibers to enhance their mechanical stability and prolong drug release. The developed collagen nanocomposites aimed to slowly release local anesthetics and promote wound healing. The findings of this research could have significant implications for improving the pain management and wound healing associated with antler removal in deer. The results obtained from the in vitro drug release tests, pharmacokinetic analysis, and analgesic efficacy evaluations provide valuable insights into the understanding and development of novel approaches for antler removal procedures in red deer. The findings contribute to the advancement of knowledge in this field and lay the foundation for future implementation of improved techniques and protocols for antler removal.


Assuntos
Chifres de Veado , Cervos , Óxido de Zinco , Animais , Anestésicos Locais , Manejo da Dor , Colágeno , Dor/tratamento farmacológico , Bandagens , Analgésicos
2.
Animals (Basel) ; 10(11)2020 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-33153106

RESUMO

New Zealand deer farming centres on the production of meat and velvet antler. Velvet antler removal is a painful procedure and currently, New Zealand Animal Welfare regulations dictate surgical removal of velvet antlers under lignocaine anaesthesia. To improve our knowledge on the efficacy and duration of other local anaesthetics to mitigate pain after antler removal, it is important to accurately assess and quantify pain arising from antler removal. Therefore, the current study was designed to validate mechanical nociceptive threshold (MNT) testing using a Wagner hand-held algometer, and to apply this methodology to assess the efficacy and duration of action of articaine for antler removal in deer. Baseline force (N) required to elicit the nociceptive response was recorded in 40 yearling male red deer on three alternate days. Ten of the 40 animals were selected for antler removal after administration of 4% articaine hydrochloride as a ring block. The duration of analgesic efficacy of articaine was assessed by algometry across 5 time points. There was a significant difference in MNTs among the three days (day 3 versus day 1 (p < 0.0001), day 2 versus day 1 (p < 0.0001), and day 1 versus day 2 (p < 0.01)). Positive correlations were observed between weight, antler length and thresholds. The MNT values remained above 20N for 6 h after removal of velvet antlers under the articaine ring block. This study provides valuable information about the use of MNT in red deer. These findings lay a foundation for future studies in the topics of peri-operative and postoperative pain management in deer antler removal, and a possible alternative use for articaine.

3.
Bioelectromagnetics ; 39(8): 585-594, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30462846

RESUMO

A great deal of evidence has confirmed that electromagnetic fields (EMFs) can affect the central nervous system. In this study, cultured neonatal human retinal pigment epithelial (hRPE) cells were exposed to pulsed EMF of 1 mT intensity and 50 Hz frequency 8 h daily for 3 days. In addition to cell proliferation and cell death assays, immunocytochemistry for RPE65, PAX6, nestin, and cytokeratin 8/18 proteins were performed. Real-time reverse transcriptase polymerase chain reaction (RT-PCR) was performed for NES, PAX6, RPE65, and ACTA2 gene expression. Exposed hRPE cells did not demonstrate significant change in terms of cytomorphology, cell proliferation, or cell death. Protein expression of PAX6 was decreased in treated cells compared to controls and remained unchanged for RPE65, cytokeratin 8/18, and nestin. Gene expressions of NES, RPE65, and PAX6 were decreased in treated cells as compared to controls. Gene expression of ACTA2 did not significantly change. In conclusion, viability of cultivated neonatal hRPE cells did not change after short exposure to a safe dose of pulsed EMF albeit that both gene and protein expressions of retinal progenitor cell markers were reduced. Whether longer exposure durations that are being constantly produced by widely-used electronic devices may induce significant changes in these cells, needs further investigation. Bioelectromagnetics. 39:585-594, 2018. © 2018 Wiley Periodicals, Inc.


Assuntos
Campos Eletromagnéticos , Epitélio Pigmentado da Retina/citologia , Morte Celular/efeitos da radiação , Proliferação de Células/efeitos da radiação , Células Cultivadas , Regulação da Expressão Gênica/efeitos da radiação , Humanos , Recém-Nascido
4.
Exp Eye Res ; 145: 216-223, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-26795389

RESUMO

This study was conducted to investigate the effect of combining extremely low frequency-pulsed electromagnetic field (ELF-PEMF) and low-level laser therapy (LLLT) on alkali-burned rabbit corneas. Fifty alkali-burned corneas of 50 rabbits were categorized into five groups: ELF-PEMF therapy with 2 mT intensity (ELF 2) for 2 h daily; LLLT for 30 min twice daily; combined ELF-PEMF and LLLT (ELF + LLLT); medical therapy (MT); and control (i.e., no treatment). Clinical examination and digital photography of the corneas were performed on days 0, 2, 7, and 14. After euthanizing the rabbits, the affected eyes were evaluated by histopathology. The clinical and histopathologic results were compared between the groups. On days 7 and 14, no significant difference in the corneal defect area was evident between the ELF, LLLT, ELF + LLLT, and MT groups. Excluding the controls, none of the study groups demonstrated a significant corneal neovascularization in both routine histopathology and immunohistochemistry for CD31. Keratocyte loss was significantly higher in the MT group than in the ELF, LLLT, and ELF + LLLT groups. Moderate to severe stromal inflammation in the LLLT group was comparable with that in the MT group and was significantly lower than that in the other groups. In conclusion, combining LLLT and ELF was not superior to ELF alone or LLLT alone in healing corneal alkali burns. However, given the lower intensity of corneal inflammation and the lower rate of keratocytes loss with LLLT, this treatment may be superior to other proposed treatment modalities for healing alkali-burned corneas.


Assuntos
Queimaduras Químicas/terapia , Lesões da Córnea/terapia , Queimaduras Oculares/terapia , Terapia com Luz de Baixa Intensidade/métodos , Magnetoterapia/métodos , Álcalis , Animais , Modelos Animais de Doenças , Feminino , Coelhos
5.
Invest Ophthalmol Vis Sci ; 53(12): 7881-8, 2012 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-23132802

RESUMO

PURPOSE: To investigate the short-term effects of extremely low frequency pulsed electromagnetic fields (ELF-PEMF) on the healing of alkaline-burned corneas in rabbits. METHODS: Fifty-six alkaline-burned corneas from 56 rabbits were categorized into four groups: ELF-PEMF therapy with 2 mTesla (mT) intensity (ELF 2) for 30 minutes twice daily, ELF-PEMF therapy with 5 mT intensity (ELF 5) for 30 minutes twice daily, medical therapy (MT), and controls. Clinical examination together with digital photography of the corneas was performed on days 0, 2, 7, and 14. After euthanizing the rabbits, affected eyes were evaluated by way of histopathology. Finally the clinical and the histopathologic results of the four groups were compared. RESULTS: None of the cases developed limbal ischemia, symblepharon formation, Descemetocele, or corneal perforation. Although the area of corneal defect in the ELF groups on day 2 was significantly less than the defects in MT, it was not notably different from those on days 7 and 14. Rate of significant corneal neovascularization on days 7 and 14 was not statistically different between the groups. The keratocyte loss in MT was significantly higher than in the ELF groups. Mild stromal scar formation was observed more frequently in ELF-PEMF groups than the control. CONCLUSIONS: Short-term ELF-PEMF therapy is a safe, noninvasive, and markedly effective method in healing alkaline-burned corneas, and its therapeutic results are comparable with those of MT.


Assuntos
Queimaduras Químicas/radioterapia , Lesões da Córnea , Campos Eletromagnéticos , Queimaduras Oculares/radioterapia , Cicatrização/fisiologia , Álcalis/toxicidade , Animais , Queimaduras Químicas/patologia , Córnea/patologia , Córnea/efeitos da radiação , Modelos Animais de Doenças , Queimaduras Oculares/patologia , Feminino , Coelhos , Doses de Radiação , Resultado do Tratamento
6.
Vet Ophthalmol ; 15(3): 206-9, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22050958

RESUMO

OBJECTIVE: The present study was undertaken to establish reference values for Schirmer tear test (STT) and intraocular pressure (IOP) in the long-eared hedgehog (Hemiechinus auritus). ANIMALS: Fourteen healthy long-eared hedgehogs (H. auritus) of either sex were studied. PROCEDURES: The hedgehogs were individually immobilized with an intramuscular injection of combined Ketamine (20 mg/kg) and Diazepam (0.5 mg/kg), and each animal underwent ophthalmic examinations including: STT, tonometry, biomicroscopy, and indirect ophthalmoscopy. RESULTS: No significant effects of animal gender, weight, side (right vs. left eye) were found in this study. Mean (SD) STT values for all eyes (n = 28) were 1.7 ± 1.2 mm/1 min with a range of 0-4 mm/1 min. Mean STT in male animals was 2.2 ± 1.2. Mean STT in female Hedgehogs was 1.3 ± 1.1. Mean (SD) IOP values by applanation tonometry were 20.1 ± 4.0 mmHg (range 11.5-26.5 mmHg). Mean (SD) IOP values by applanation tonometry were 18.2 ± 4.0 and 22.0 ± 3.2 mmHg for males and females, respectively. CONCLUSIONS: This study reports STT and IOP findings in long-eared hedgehogs (H. auritus).


Assuntos
Ouriços/fisiologia , Pressão Intraocular/fisiologia , Lágrimas/metabolismo , Animais , Feminino , Masculino , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...