Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Clin Med (Lond) ; 21(2): 155-157, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33762380

RESUMO

Neurological manifestations associated with SARS-CoV-2 infection as well as its pathogenesis are insufficiently explained. We present two cases of severe COVID-19 who required hospitalisation in the intensive care unit with persistently depressed mental status and severe leukoencephalopathy. We discuss the clinical and radiological findings and also propose the possible pathogenesis involved.


Assuntos
COVID-19 , Leucoencefalopatias , Humanos , Leucoencefalopatias/diagnóstico por imagem , SARS-CoV-2
2.
Pediatr Res ; 81(1-1): 80-87, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27653084

RESUMO

BACKGROUND: Early infant diagnosis (EID) of HIV-1 is necessary to reduce HIV-related mortality. As maternal antibodies transferred across the placenta may persist up to 18 mo, commercial virological assays (CVAs) are needed. This study compares four CVAs for EID using dried blood specimens (DBS) from HIV-1-exposed infants. METHODS: DBS from 68 infants born to HIV-1-infected women were collected from November 2012 to December 2013 in Equatorial Guinea. Four CVAs were performed: Siemens VERSANT HIV-1 RNA 1.0 kPCR assay, Roche CAP/CTM Quantitative Test v2.0, CAP/CTM Qualitative Tests v1.0 and v2.0. Definitive diagnosis was established following World Health Organization (WHO) recommendations. RESULTS: Two HIV-1-infected infants (2.9%) were detected by the four CVAs while 49 (72%) resulted negative. Discordant results were observed in 17 (25%) infants and HIV-1 infection was excluded in 14 patients when virological and serological testing was performed in additional DBS. Different false-positive rates HIV-1 were observed with Roche assays. CONCLUSION: CVAs using DBS were useful for EID, although discrepant results were common. Further research is required to reduce false-positive results that could result in wrong diagnosis and unneeded treatment. We propose caution with low viral load (VL) values when using VL assays. Clear guidelines are required for EID of HIV-exposed infants with discrepant virological results.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-1 , Adulto , Bioensaio/métodos , Teste em Amostras de Sangue Seco/métodos , Diagnóstico Precoce , Guiné Equatorial , Reações Falso-Positivas , Feminino , Infecções por HIV/transmissão , HIV-1/genética , HIV-1/isolamento & purificação , Humanos , Lactente , Recém-Nascido , Transmissão Vertical de Doenças Infecciosas , Masculino , Gravidez , Complicações Infecciosas na Gravidez/tratamento farmacológico , Complicações Infecciosas na Gravidez/virologia , RNA Viral/sangue , RNA Viral/genética , Virologia/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...