Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Radiol Phys Technol ; 17(2): 451-457, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38687457

RESUMO

Measurement-based verification is impossible for the patient-specific quality assurance (QA) of online adaptive magnetic resonance imaging-guided radiotherapy (oMRgRT) because the patient remains on the couch throughout the session. We assessed a deep learning (DL) system for oMRgRT to predict the gamma passing rate (GPR). This study collected 125 verification plans [reference plan (RP), 100; adapted plan (AP), 25] from patients with prostate cancer treated using Elekta Unity. Based on our previous study, we employed a convolutional neural network that predicted the GPRs of nine pairs of gamma criteria from 1%/1 mm to 3%/3 mm. First, we trained and tested the DL model using RPs (n = 75 and n = 25 for training and testing, respectively) for its optimization. Second, we tested the GPR prediction accuracy using APs to determine whether the DL model could be applied to APs. The mean absolute error (MAE) and correlation coefficient (r) of the RPs were 1.22 ± 0.27% and 0.29 ± 0.10 in 3%/2 mm, 1.35 ± 0.16% and 0.37 ± 0.15 in 2%/2 mm, and 3.62 ± 0.55% and 0.32 ± 0.14 in 1%/1 mm, respectively. The MAE and r of the APs were 1.13 ± 0.33% and 0.35 ± 0.22 in 3%/2 mm, 1.68 ± 0.47% and 0.30 ± 0.11 in 2%/2 mm, and 5.08 ± 0.29% and 0.15 ± 0.10 in 1%/1 mm, respectively. The time cost was within 3 s for the prediction. The results suggest the DL-based model has the potential for rapid GPR prediction in Elekta Unity.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética , Aceleradores de Partículas , Neoplasias da Próstata , Radioterapia Guiada por Imagem , Humanos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Masculino , Planejamento da Radioterapia Assistida por Computador/métodos , Raios gama
2.
J Radiat Res ; 65(1): 87-91, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38091980

RESUMO

The purpose of this study was to show the safety of volumetric modulated arc therapy (VMAT) with deep inspiration breath-hold (DIBH) in hypofractionated radiotherapy for left-sided breast cancer after breast-conserving surgery in a clinical setting. Twenty-five Japanese women, aged 20-59 years, who were enrolled in this prospective non-inferiority study received VMAT under the condition of DIBH with 42.4 Gy/16 fractions for whole-breast irradiation (WBI) ± boost irradiation for the tumor bed to show the non-inferiority of VMAT with DIBH to conventional fractionated WBI with free breathing. The primary endpoint was the rate of occurrence of radiation dermatitis of Grade 3 or higher or pneumonitis of Grade 2 or higher within 6 months after the start of radiotherapy. This study was registered with UMIN00004321. All of the enrolled patients completed the planned radiotherapy without interruption. The evaluation of adverse events showed that three patients (12.0%) had Grade 2 radiation dermatitis. There was no other Grade 2 adverse event and there was no patient with an adverse event of Grade 3 or higher. Those results confirmed our hypothesis that the experimental treatment method is non-inferior compared with our historical results. There was no patient with locoregional recurrence or metastases. In conclusion, VMAT under the condition of DIBH in hypofractionated radiotherapy for left-sided breast cancer after breast-conserving surgery can be performed safely in a clinical setting.


Assuntos
Neoplasias da Mama , Dermatite , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Feminino , Humanos , Radioterapia de Intensidade Modulada/métodos , Mastectomia Segmentar , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Unilaterais da Mama/radioterapia , Estudos Prospectivos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Recidiva Local de Neoplasia , Dermatite/etiologia , Coração , Órgãos em Risco
3.
J Appl Clin Med Phys ; 24(12): e14122, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37559561

RESUMO

The Unity magnetic resonance (MR) linear accelerator (MRL) with MR-guided adaptive radiotherapy (MRgART) is capable of online MRgART where images are acquired on the treatment day and the radiation treatment plan is immediately replanned and performed. We evaluated the MRgART plan quality and plan reproducibility of the Unity MRL in patients with prostate cancer. There were five low- or moderate-risk and five high-risk patients who received 36.25 Gy or 40 Gy, respectively in five fractions. All patients underwent simulation magnetic resonance imaging (MRI) and five online adaptive MRI. We created plans for 5, 7, 9, 16, and 20 beams and for 60, 100, and 150 segments. We evaluated the target and organ doses for different number of beams and segments, respectively. Variation in dose constraint between the simulation plan and online adaptive plan was measured for each patient to assess plan reproducibility. The plan quality improved with the increasing number of beams. However, the proportion of significantly improved dose constraints decreased as the number of beams increased. For some dose parameters, there were statistically significant differences between 60 and 100 segments, and 100 and 150 segments. The plan of five beams exhibited limited reproducibility. The number of segments had minimal impact on plan reproducibility, but 60 segments sometimes failed to meet dose constraints for online adaptive plan. The optimization and delivery time increased with the number of beams and segments. We do not recommend using five or fewer beams for a reproducible and high-quality plan in the Unity MRL. In addition, many number of segments and beams may help meet dose constraints during online adaptive plan. Treatment with the Unity MRL should be performed with the appropriate number of beams and segments to achieve a good balance among plan quality, delivery time, and optimization time.


Assuntos
Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador , Masculino , Humanos , Reprodutibilidade dos Testes , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Próstata/radioterapia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
4.
J Radiat Res ; 64(5): 783-794, 2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37466450

RESUMO

In external radiotherapy of head and neck (HN) cancers, the reduction of irradiation accuracy due to HN volume reduction often causes a problem. Adaptive radiotherapy (ART) can effectively solve this problem; however, its application to all cases is impractical because of cost and time. Therefore, finding priority cases is essential. This study aimed to predict patients with HN cancers are more likely to need ART based on a quantitative measure of large HN volume reduction and evaluate model accuracy. The study included 172 cases of patients with HN cancer who received external irradiation. The HN volume was calculated using cone-beam computed tomography (CT) for irradiation-guided radiotherapy for all treatment fractions and classified into two groups: cases with a large reduction in the HN volume and cases without a large reduction. Radiomic features were extracted from the primary gross tumor volume (GTV) and nodal GTV of the planning CT. To develop the prediction model, four feature selection methods and two machine-learning algorithms were tested. Predictive performance was evaluated by the area under the curve (AUC), accuracy, sensitivity and specificity. Predictive performance was the highest for the random forest, with an AUC of 0.662. Furthermore, its accuracy, sensitivity and specificity were 0.692, 0.700 and 0.813, respectively. Selected features included radiomic features of the primary GTV, human papillomavirus in oropharyngeal cancer and the implementation of chemotherapy; thus, these features might be related to HN volume change. Our model suggested the potential to predict ART requirements based on HN volume reduction .


Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias Orofaríngeas , Humanos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Pescoço , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico , Estudos Retrospectivos
5.
J Appl Clin Med Phys ; 24(4): e13890, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36609786

RESUMO

PURPOSE: To study the dosimetry impact of deformable image registration (DIR) using radiophotoluminescent glass dosimeter (RPLD) and custom developed phantom with various inserts. METHODS: The phantom was developed to facilitate simultaneous evaluation of geometric and dosimetric accuracy of DIR. Four computed tomography (CT) images of the phantom were acquired with four different configurations. Four volumetric modulated arc therapy (VMAT) plans were computed for different phantom. Two different patterns were applied to combination of four phantom configurations. RPLD dose measurement was combined between corresponding two phantom configurations. DIR-based dose accumulation was calculated between corresponding two CT images with two commercial DIR software and various DIR parameter settings, and an open source software. Accumulated dose calculated using DIR was then compared with measured dose using RPLD. RESULTS: The mean ± standard deviation (SD) of dose difference was 2.71 ± 0.23% (range, 2.22%-3.01%) for tumor-proxy and 3.74 ± 0.79% (range, 1.56%-4.83%) for rectum-proxy. The mean ± SD of target registration error (TRE) was 1.66 ± 1.36 mm (range, 0.03-4.43 mm) for tumor-proxy and 6.87 ± 5.49 mm (range, 0.54-17.47 mm) for rectum-proxy. These results suggested that DIR accuracy had wide range among DIR parameter setting. CONCLUSIONS: The dose difference observed in our study was 3% for tumor-proxy and within 5% for rectum-proxy. The custom developed physical phantom with inserts showed potential for accurate evaluation of DIR-based dose accumulation. The prospect of simultaneous evaluation of geometric and dosimetric DIR accuracy in a single phantom may be useful for validation of DIR for clinical use.


Assuntos
Processamento de Imagem Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Processamento de Imagem Assistida por Computador/métodos , Dosímetros de Radiação , Radiometria , Tomografia Computadorizada por Raios X/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Planejamento da Radioterapia Assistida por Computador/métodos
6.
PLoS One ; 17(12): e0278707, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36459528

RESUMO

BACKGROUND AND PURPOSE: The purpose of this prospective study was to investigate changes in longitudinal parameters after stereotactic radiotherapy for lung cancer and to identify possible pretreatment factors related to radiation-induced lung toxicity and the decline in pulmonary function after radiotherapy. MATERIALS AND METHODS: Protocol-specified examinations, including 4-D CT, laboratory tests, pulmonary function tests (PFTs) and body composition measurements, were performed before SRT and at 1 month, 4 months and 12 months after stereotactic radiotherapy. Longitudinal differences were tested by using repeated-measures analysis of variance. Correlations were examined by using the Pearson product-moment correlation coefficient (r). RESULTS: Sixteen patients were analyzed in this study. During a median follow-up period of 26.6 months, grade 1 and 2 lung toxicity occurred in 11 patients and 1 patient, respectively. The mean Hounsfield units (HU) and standard deviation (SD) of the whole lung, as well as sialylated carbohydrate antigen KL-6 (KL-6) and surfactant protein-D (SP-D), peaked at 4 months after radiotherapy (p = 0.11, p<0.01, p = 0.04 and p<0.01, respectively). At 4 months, lung V20 Gy (%) and V40 Gy (%) were correlated with changes in SP-D, whereas changes in the mean HU of the lung were related to body mass index and lean body mass index (r = 0.54, p = 0.02; r = 0.57, p = 0.01; r = 0.69, p<0.01; and r = 0.69, p<0.01, respectively). The parameters of PFTs gradually declined over time. When regarding the change in PFTs from pretreatment to 12 months, lung V5 Gy (cc) showed significant correlations with diffusion capacity for carbon monoxide (DLCO), DLCO/alveolar volume and the relative change in DLCO (r = -0.72, p<0.01; r = -0.73, p<0.01; and r = -0.63, p = 0.01, respectively). CONCLUSIONS: The results indicated that some parameters peaked at 4 months, but PFTs were the lowest at 12 months. Significant correlations between lung V5 Gy (cc) and changes in DLCO and DLCO/alveolar volume were observed.


Assuntos
Neoplasias Pulmonares , Lesões por Radiação , Radiocirurgia , Humanos , Proteína D Associada a Surfactante Pulmonar , Estudos Prospectivos , Radiocirurgia/efeitos adversos , Neoplasias Pulmonares/radioterapia , Pulmão
8.
Phys Med ; 77: 75-83, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32795891

RESUMO

We evaluated four-dimensional cone beam computed tomography (4D-CBCT) ventilation images (VICBCT) acquired with two different linear accelerator systems at various gantry speeds using a deformable lung phantom. The 4D-CT and 4D-CBCT scans were performed using a computed tomography (CT) scanner, an X-ray volume imaging system (Elekta XVI) mounted in Versa HD, and an On-Board Imager (OBI) system mounted in TrueBeam. Intensity-based deformable image registration (DIR) was performed between peak-exhale and peak-inhale images. VICBCT- and 4D-CT-based ventilation images (VICT) were derived by DIR using two metrics: one based on the Jacobian determinant and one on changes in the Hounsfield unit (HU). Three different DIR regularization values (λ) were used for VICBCT. Correlations between the VICBCT and VICT values were evaluated using voxel-wise Spearman's rank correlation coefficient (r). In case of both metrics, the Jacobian-based VICBCT with a gantry speed of 0.6 deg/sec in Versa HD showed the highest correlation for all the gantry speeds (e.g., λ = 0.05 and r = 0.68). Thus, the r value of the Jacobian-based VICBCT was greater or equal to that of the HU-based VICBCT. In addition, the ventilation accuracy of VICBCT increased at low gantry speeds. Thus, the image quality of VICBCT was affected by the change in gantry speed in both the imaging systems. Additionally, DIR regularization considerably influenced VICBCT in both the imaging systems. Our results have the potential to assist in designing CBCT protocols, incorporating VICBCT imaging into the functional avoidance planning process.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Tomografia Computadorizada de Feixe Cônico , Humanos , Pulmão/diagnóstico por imagem , Aceleradores de Partículas , Imagens de Fantasmas
9.
J Radiat Res ; 61(3): 470-478, 2020 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-32100833

RESUMO

The purpose of this study was to reveal treatment outcomes and toxicity after pelvic intensity-modulated radiotherapy (IMRT) for postoperative uterine cervical cancer of Japanese patients. Consecutive patients who were treated with pelvic IMRT for postoperative cervical cancer in our institute were retrospectively analyzed. Relapse-free survival (RFS) and overall survival (OS) were calculated using the Kaplan-Meier estimator, and log-rank tests were used to compare differences. From the database, 62 patients were identified. The pathology was squamous cell carcinoma in 44 patients and other pathology in 18 patients. Of the 62 patients, 35 had high-risk prognostic factors and 27 patients had intermediate-risk prognostic factors. The prescribed radiation doses were 50 Gy in 25 fractions for 58 patients and 50.4 Gy in 28 fractions for 4 patients. One patient received a vaginal cuff boost. Chemotherapy was administered in 36 patients. During the median follow-up period of 50.9 months, there was no locoregional failure. Six patients in the high-risk group relapsed, but none of the patients in the intermediate-risk group relapsed (P = 0.02). The 3-year OS and RFS rates were 98.2% and 90.9%, respectively. Significant factors related to RFS were squamous cell carcinoma pathology (P = 0.02), pathological T stage (P = 0.04), surgical margin status (P < 0.01) and multiple lymph nodes metastases (P < 0.01). Grade 3 or more toxicity occurred in 6 patients. Four patients had obstruction of the intestine, and 2 patients had stenosis of the urinary tract. In clinical practice, the use of pelvic IMRT for postoperative cervical cancer of Japanese patients showed a low rate of toxicity without decreasing the efficacy.


Assuntos
Carcinoma de Células Escamosas/terapia , Quimiorradioterapia , Radioterapia de Intensidade Modulada , Radioterapia , Neoplasias do Colo do Útero/terapia , Adulto , Idoso , Carcinoma de Células Escamosas/mortalidade , Carcinoma de Células Escamosas/cirurgia , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Incidência , Japão , Estimativa de Kaplan-Meier , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Período Pós-Operatório , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Neoplasias do Colo do Útero/mortalidade , Neoplasias do Colo do Útero/cirurgia
10.
Radiol Phys Technol ; 12(3): 351-356, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31364005

RESUMO

We evaluated an anthropomorphic head and neck phantom with tissue heterogeneity, produced using a personal 3D printer, with quality assurance (QA), specific to patients undergoing intensity-modulated radiation therapy (IMRT). Using semi-automatic segmentation, 3D models of bone, soft tissue, and an air-filled cavity were created based on computed tomography (CT) images from patients with head and neck cancer treated with IMRT. For the 3D printer settings, polylactide was used for soft tissue with 100% infill. Bone was reproduced by pouring plaster into the cavity created by the 3D printer. The average CT values for soft tissue and bone were 13.0 ± 144.3 HU and 439.5 ± 137.0 HU, respectively, for the phantom and 12.1 ± 124.5 HU and 771.5 ± 405.3 HU, respectively, for the patient. The gamma passing rate (3%/3 mm) was 96.1% for a nine-field IMRT plan. Thus, this phantom may be used instead of a standard shape phantom for patient-specific QA in IMRT.


Assuntos
Cabeça , Pescoço , Imagens de Fantasmas , Impressão Tridimensional , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia de Intensidade Modulada/instrumentação , Cabeça/diagnóstico por imagem , Humanos , Pescoço/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
11.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 74(12): 1396-1405, 2018 12.
Artigo em Japonês | MEDLINE | ID: mdl-30568089

RESUMO

This study aimed to develop and evaluate field shape optimization technique based on dose calculation using daily cone-beam computed tomography (CBCT) to compensate for interfractional anatomic changes in three-dimensional conformal radiation therapy (3D-CRT) for prostate cancer. For each of 10 patients, 9-10 CBCT images were obtained throughout the treatment course. The prostate, seminal vesicles, and rectum were manually contoured in all CBCT images. Subsequently, plan adaptation was performed with a program developed in-house. This program calculates dose distributions on CBCT images and optimizes field shape to minimize rectal dose while keeping the target at the optimal dose coverage (the planning target volume D95% receives 95% of the prescription dose). To evaluate the adaptive planning approach, we re-calculated dose distributions on CBCT images based on the conventional and adaptive plans. For the entire cohort, plan adaptation improved rectal V50 Gy, V60 Gy, V65 Gy, and V70 Gy by -7.71±8.43%, -8.30±8.90%, -7.91±8.51% and -7.03±7.70% on average (±SD), respectively. Our results demonstrate that adaptive planning approach is superior to the conventional planning approach for optimizing dose distribution, and this adaptive approach can optimize field shape in 3 min. The proposed approach can be an effective solution for the problem of interfractional anatomic changes in 3D-CRT for prostate cancer.


Assuntos
Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica
12.
Med Phys ; 45(7): 2937-2946, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29772081

RESUMO

PURPOSE: An accurate source model of a medical linear accelerator is essential for Monte Carlo (MC) dose calculations. This study aims to propose an analytical photon source model based on particle transport in parameterized accelerator structures, focusing on a more realistic determination of linac photon spectra compared to existing approaches. METHODS: We designed the primary and secondary photon sources based on the photons attenuated and scattered by a parameterized flattening filter. The primary photons were derived by attenuating bremsstrahlung photons based on the path length in the filter. Conversely, the secondary photons were derived from the decrement of the primary photons in the attenuation process. This design facilitates these sources to share the free parameters of the filter shape and be related to each other through the photon interaction in the filter. We introduced two other parameters of the primary photon source to describe the particle fluence in penumbral regions. All the parameters are optimized based on calculated dose curves in water using the pencil-beam-based algorithm. To verify the modeling accuracy, we compared the proposed model with the phase space data (PSD) of the Varian TrueBeam 6 and 15 MV accelerators in terms of the beam characteristics and the dose distributions. The EGS5 Monte Carlo code was used to calculate the dose distributions associated with the optimized model and reference PSD in a homogeneous water phantom and a heterogeneous lung phantom. We calculated the percentage of points passing 1D and 2D gamma analysis with 1%/1 mm criteria for the dose curves and lateral dose distributions, respectively. RESULTS: The optimized model accurately reproduced the spectral curves of the reference PSD both on- and off-axis. The depth dose and lateral dose profiles of the optimized model also showed good agreement with those of the reference PSD. The passing rates of the 1D gamma analysis with 1%/1 mm criteria between the model and PSD were 100% for 4 × 4, 10 × 10, and 20 × 20 cm2 fields at multiple depths. For the 2D dose distributions calculated in the heterogeneous lung phantom, the 2D gamma pass rate was 100% for 6 and 15 MV beams. The model optimization time was less than 4 min. CONCLUSION: The proposed source model optimization process accurately produces photon fluence spectra from a linac using valid physical properties, without detailed knowledge of the geometry of the linac head, and with minimal optimization time.


Assuntos
Modelos Teóricos , Método de Monte Carlo , Aceleradores de Partículas , Fótons , Doses de Radiação , Imagens de Fantasmas
13.
Clin Lung Cancer ; 19(1): e85-e90, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28655592

RESUMO

BACKGROUND: The aim of this study was to determine the prognostic factors of radiation pneumonitis (RP) after stereotactic body radiotherapy (SBRT). PATIENTS AND METHODS: A total of 50 patients (36 male and 14 female) were treated with SBRT for 42 primary lung cancers and 8 metastatic lung cancers. SBRT was performed with 48 Gy in 4 fractions to the isocenter or with 40 Gy in 4 fractions covering 95% of the planning target volume. Percentage of low attenuation area (%LAA) was defined as percentage of the lung area with attenuation of -860 Hounsfield units (HU) or lower (%LAA-860) or of -960 HU or lower (%LAA-960). The dosimetric parameter of V20 Gy, which means percentage volume of the lung receiving 20 Gy or more, was recalculated. RP was assessed using Common Terminology Criteria for Adverse Events version 4.0. RESULTS: The median follow-up period was 39.0 months (range, 7.2-94.5 months). RP of Grade 0, Grade 1, and Grade 2 to 3 was diagnosed in 11, 29, and 10 patients, respectively. Multivariate analyses (MVA) for Grade 1 showed that higher %LAA-860 and higher %LAA-960 were significantly associated with a lower rate of Grade 1 RP. MVA for Grade 2 to 3 showed that lower Brinkman index and lower lung V20 Gy were significantly associated with a lower rate of Grade 2 to 3 RP, and, in contrast, %LAA-860 and %LAA-960 had no association with Grade 2 to 3 RP. CONCLUSION: This result suggests that high %LAA is associated with radiological changes (Grade 1) but that %LAA has no correlation with Grade 2 to 3 RP because symptomatic RP might also be affected by other factors.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Pulmão/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico , Lesões por Radiação/diagnóstico , Pneumonite por Radiação/diagnóstico , Radiocirurgia/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/complicações , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/patologia , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/diagnóstico , Masculino , Pessoa de Meia-Idade , Prognóstico , Enfisema Pulmonar/patologia , Lesões por Radiação/patologia , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/patologia , Tomografia Computadorizada por Raios X
14.
J Appl Clin Med Phys ; 18(4): 206-214, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28649722

RESUMO

The purpose of this study was comparing dose-volume histogram (DVH)-based plan verification methods for volumetric modulated arc therapy (VMAT) pretreatment QA. We evaluated two 3D dose reconstruction systems: ArcCHECK-3DVH system (Sun Nuclear corp.) and Varian dynalog-based dose reconstruction (DBDR) system, developed in-house. Fifteen prostate cancer patients (67.6 Gy/26 Fr), four head and neck cancer patient (66 Gy/33 Fr), and four esophagus cancer patients (60 Gy/30 Fr) treated with VMAT were studied. First, ArcCHECK measurement was performed on all plans; simultaneously, the Varian dynalog data sets that contained the actual delivered parameters (leaf positions, gantry angles, and cumulative MUs) were acquired from the Linac control system. Thereafter, the delivered 3D patient dose was reconstructed by 3DVH software (two different calculating modes were used: High Sensitivity (3DVH-HS) and Normal Sensitivity (3DVH-NS)) and in-house DBDR system. We evaluated the differences between the TPS-calculated dose and the reconstructed dose using 3D gamma passing rates and DVH dose index analysis. The average 3D gamma passing rates (3%/3 mm) between the TPS-calculated dose and the reconstructed dose were 99.1 ± 0.6%, 99.7 ± 0.3%, and 100.0 ± 0.1% for 3DVH-HS, 3DVH-NS, and DBDR, respectively. For the prostate cases, the average differences between the TPS-calculated dose and reconstructed dose in the PTV mean dose were 1.52 ± 0.50%, -0.14 ± 0.55%, and -0.03 ± 0.07% for 3DVH-HS, 3DVH-NS, and DBDR, respectively. For the head and neck and esophagus cases, the dose difference to the TPS-calculated dose caused by an effect of heterogeneity was more apparent under the 3DVH dose reconstruction than the DBDR. Although with some residual dose reconstruction errors, these dose reconstruction methods can be clinically used as effective tools for DVH-based QA for VMAT delivery.


Assuntos
Neoplasias Esofágicas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/métodos , Humanos , Masculino , Garantia da Qualidade dos Cuidados de Saúde , Sensibilidade e Especificidade , Software
15.
J Radiat Res ; 58(4): 567-571, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28158642

RESUMO

This study aimed to evaluate the performance of the hybrid deformable image registration (DIR) method in comparison with intensity-based DIR for pelvic cone-beam computed tomography (CBCT) images, using intensity and anatomical information. Ten prostate cancer patients treated with intensity-modulated radiation therapy (IMRT) were studied. Nine or ten CBCT scans were performed for each patient. First, rigid registration was performed between the planning CT and all CBCT images using gold fiducial markers, and then DIR was performed. The Dice similarity coefficient (DSC) and center of mass (COM) displacement were used to evaluate the quantitative DIR accuracy. The average DSCs for intensity-based DIR for the prostate, rectum, bladder, and seminal vesicles were 0.84 ± 0.05, 0.75 ± 0.05, 0.69 ± 0.07 and 0.65 ± 0.11, respectively, whereas those values for hybrid DIR were 0.98 ± 0.00, 0.97 ± 0.01, 0.98 ± 0.00 and 0.94 ± 0.03, respectively (P < 0.05). The average COM displacements for intensity-based DIR for the prostate, rectum, bladder, and seminal vesicles were 2.0 ± 1.5, 3.7 ± 1.4, 7.8 ± 2.2 and 3.6 ± 1.2 mm, whereas those values for hybrid DIR were 0.1 ± 0.0, 0.3 ± 0.2, 0.2 ± 0.1 and 0.6 ± 0.6 mm, respectively (P < 0.05). These results showed that the DSC for hybrid DIR had a higher DSC value and smaller COM displacement for all structures and all patients, compared with intensity-based DIR. Thus, the accumulative dose based on hybrid DIR might be trusted as a high-precision dose estimation method that takes into account organ movement during treatment radiotherapy.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Pelve/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Planejamento da Radioterapia Assistida por Computador , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Reto/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem
16.
Med Phys ; 44(4): 1445-1455, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28214368

RESUMO

PURPOSE: In this study, we developed a 3D-printed deformable pelvis phantom for evaluating spatial DIR accuracy. We then evaluated the spatial DIR accuracies of various DIR settings for cervical cancer. METHODS: A deformable female pelvis phantom was created based on patient CT data using 3D printing. To create the deformable uterus phantom, we first 3D printed both a model of uterus and a model of the internal cavities of the vagina and uterus. We then made a mold using the 3D printed uterus phantom. Finally, urethane was poured into the mold with the model of the internal cavities in place, creating the deformable uterus phantom with a cavity into which an applicator could be inserted. To create the deformable bladder phantom, we first 3D printed models of the bladder and of the same bladder scaled down by 2 mm. We then made a mold using the larger bladder model. Finally, silicone was poured into the mold with the smaller bladder model in place to create the deformable bladder phantom with a wall thickness of 2 mm. To emulate the anatomical bladder, water was poured into the created bladder. We acquired phantom image without applicator for EBRT. Then, we inserted the applicator into the phantom to simulate BT. In this situation, we scanned the phantom again to obtain the phantom image for BT. We performed DIR using the two phantom images in two cases: Case A, with full bladder (170 ml) in both EBRT and BT images; and Case B with full bladder in the BT image and half-full bladder (100 ml) in the EBRT image. DIR was evaluated using Dice similarity coefficients (DSCs) and 31 landmarks for the uterus and 25 landmarks for the bladder. A hybrid intensity and structure DIR algorithm implemented in RayStation with four DIR settings was evaluated. RESULTS: On visual inspection, reasonable agreement in shape of the uterus between the phantom and patient CT images was observed for both EBRT and BT, although some regional disagreements in shape of the bladder and rectum were apparent. The created phantom could reproduce the actual patient's uterus deformation by the applicator. For both Case A and B, large variation was seen in landmark error among the four DIR parameters. In addition, although DSCs were comparable, moderate differences in landmark error existed between the two different DIR parameters selected from the four DIR parameters (i.e., DSC = 0.96, landmark error = 13.2 ± 5.7 mm vs. DSC = 0.97, landmark error = 9.7 ± 4.0 mm). This result suggests that landmark error evaluation might thus be more effective than DSC for evaluating DIR accuracy. CONCLUSIONS: Our developed phantom enabled the evaluation of spatial DIR accuracy for the female pelvic region for the first time. Although the DSCs are high, the spatial errors can still be significant and our developed phantom facilitates their quantification. Our results showed that optimization is needed to identify suitable DIR settings. For determining suitable DIR settings, our method of evaluating spatial DIR accuracy using the 3D-printed phantom may prove helpful.


Assuntos
Braquiterapia , Processamento de Imagem Assistida por Computador/instrumentação , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Impressão Tridimensional , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
17.
Artigo em Japonês | MEDLINE | ID: mdl-28111399

RESUMO

Our aim was to investigate the feasibility of a three-dimensional (3D) -printed head-and-neck (HN) immobilization device by comparing its positional accuracy and dosimetric properties with those of a conventional immobilization device (CID). We prepared a 3D-printed immobilization device (3DID) consisting of a mask and headrest with acrylonitrile-butadiene-styrene resin developed from the computed tomography data obtained by imaging a HN phantom. For comparison, a CID comprising a thermoplastic mask and headrest was prepared using the same HN phantom. We measured the setup error using the ExacTrac X-ray image system. Furthermore, using the ionization chamber and the water-equivalent phantom, we measured the changes in the dose due to the difference in the immobilization device material from the photon of 4 MV and 6 MV. The positional accuracy of the two devices were almost similar in each direction except in the vertical, lateral, and pitch directions (t-test, p<0.0001), and the maximum difference was 1 mm, and 1°. The standard deviations were not statistically different in each direction except in the longitudinal (F-test, p=0.034) and roll directions (F-test, p<0.0001). When the thickness was the same, the dose difference was almost similar at a 50 mm depth. At a 1 mm depth, the 3DID-plate had a 2.9-4.2% lower dose than the CID-plate. This study suggested that the positional accuracy and dosimetric properties of 3DID were almost similar to those of CID.


Assuntos
Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Posicionamento do Paciente , Impressão Tridimensional , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Impressão Tridimensional/instrumentação , Radiometria , Planejamento da Radioterapia Assistida por Computador/instrumentação , Reprodutibilidade dos Testes
18.
Radiat Oncol ; 11: 72, 2016 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-27229710

RESUMO

BACKGROUND: Renal atrophy is observed in an irradiated kidney. The aim of this study was to determine dose-volume histogram parameters and other factors that predict renal atrophy after 10-fraction stereotactic body radiotherapy (SBRT) for primary renal cell carcinoma (RCC). METHODS: A total of 14 patients (11 males, 3 females) who received SBRT for RCC at Tohoku University Hospital between April 2010 and February 2014 were analyzed. The median serum creatinine level was 1.1 mg/dl and two patients had a single kidney. Nine patients were implanted with fiducial markers. The median tumor diameter was 30 mm. SBRT was delivered at 70 Gy in 10 fractions for 7 tumors, at 60 Gy in 10 fractions for 2 tumors, and at 50 Gy in 10 fractions for 5 tumors with 6 and/or 15 MV X-ray using 5 to 8 multi-static beams. Renal atrophy was assessed using post-SBRT CT images after 12-24 months intervals. Correlations were examined by Spearman rank correlation analysis. Differences between two groups were evaluated by the Mann-Whitney test, and pairwise comparisons were made by the Wilcoxon signed-rank test. RESULTS: The median tumor volume shrunk from 14.8 cc to 10.6 cc (p = 0.12), and the median irradiated kidney volume changed from 160.4 cc to 137.1 cc (p < .01). The median peak creatinine level was 1.6 mg/dl after treatment (p < .01). Percentage volumes of the irradiated kidney receiving at least 10 Gy (V10, p = 0.03), V20 (p < .01), V30(p < .01), V40 (p = 0.01), mean irradiated kidney dose (p < .01), and magnitude of overlap between PTV and kidney volume (p = 0.03) were significantly correlated with post-treatment irradiated kidney volume in percent, and V20-V30 had strong correlation (r < -0.70, p < .01). Patients with implanted fiducial markers showed a significantly lower ratio of renal atrophy (p = 0.02). CONCLUSIONS: Significant renal atrophic change was observed. Dose distribution of SBRT at 20-30 Gy had a strong correlation with renal atrophy when irradiation was performed in 10 fractions.


Assuntos
Atrofia/etiologia , Carcinoma de Células Renais/cirurgia , Neoplasias Renais/cirurgia , Lesões por Radiação/etiologia , Radiocirurgia/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/complicações , Feminino , Seguimentos , Humanos , Neoplasias Renais/complicações , Masculino , Pessoa de Meia-Idade , Prognóstico , Radiometria , Dosagem Radioterapêutica , Estudos Retrospectivos , Carga Tumoral
19.
J Radiat Res ; 57(4): 387-92, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26922090

RESUMO

Irregular breathing can influence the outcome of 4D computed tomography imaging and cause artifacts. Visual biofeedback systems associated with a patient-specific guiding waveform are known to reduce respiratory irregularities. In Japan, abdomen and chest motion self-control devices (Abches) (representing simpler visual coaching techniques without a guiding waveform) are used instead; however, no studies have compared these two systems to date. Here, we evaluate the effectiveness of respiratory coaching in reducing respiratory irregularities by comparing two respiratory management systems. We collected data from 11 healthy volunteers. Bar and wave models were used as visual biofeedback systems. Abches consisted of a respiratory indicator indicating the end of each expiration and inspiration motion. Respiratory variations were quantified as root mean squared error (RMSE) of displacement and period of breathing cycles. All coaching techniques improved respiratory variation, compared with free-breathing. Displacement RMSEs were 1.43 ± 0.84, 1.22 ± 1.13, 1.21 ± 0.86 and 0.98 ± 0.47 mm for free-breathing, Abches, bar model and wave model, respectively. Period RMSEs were 0.48 ± 0.42, 0.33 ± 0.31, 0.23 ± 0.18 and 0.17 ± 0.05 s for free-breathing, Abches, bar model and wave model, respectively. The average reduction in displacement and period RMSE compared with the wave model were 27% and 47%, respectively. For variation in both displacement and period, wave model was superior to the other techniques. Our results showed that visual biofeedback combined with a wave model could potentially provide clinical benefits in respiratory management, although all techniques were able to reduce respiratory irregularities.


Assuntos
Abdome/fisiologia , Biorretroalimentação Psicológica , Retroalimentação Sensorial , Movimento (Física) , Respiração , Autocontrole , Tórax/fisiologia , Análise de Ondaletas , Adulto , Voluntários Saudáveis , Humanos , Adulto Jovem
20.
J Appl Clin Med Phys ; 16(3): 5251, 2015 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-26103486

RESUMO

The purpose of this study was to evaluate the accuracy of commercially available software, using patient DVH-based QA metrics, by investigating the correlation between estimated 3D patient dose and magnitude of MLC misalignments. We tested 3DVH software with an ArcCHECK. Two different calculating modes of ArcCHECK Planned Dose Perturbation (ACPDP) were used: "Normal Sensitivity" and "High Sensitivity". Ten prostate cancer patients treated with hypofractionated VMAT (67.6 Gy/26 Fr) in our hospital were studied. For the baseline plan, we induced MLC errors (-0.75, -0.5, -0.25, 0.25, 0.5, and 0.75 mm for each single bank). We calculated the dose differences between the ACPDP dose with error and TPS dose with error using gamma passing rates and using DVH-based QA metrics. The correlations between dose estimation error and MLC position error varied with each structure and metric. A comparison using 1%/1 mm gamma index showed that the larger was the MLC error-induced, the worse were the gamma passing rates. Slopes of linear fit to dose estimation error versus MLC position error for mean dose and D95 to the PTV were 1.76 and 1.40% mm-1, respectively, for "Normal Sensitivity", and -0.53 and -0.88% mm-1, respectively, for "High Sensitivity", showing better accuracy for "High Sensitivity" than "Normal Sensitivity". On the other hand, the slopes for mean dose to the rectum and bladder, V35 to the rectum and bladder and V55 to the rectum and bladder, were -1.00, -0.55, -2.56, -1.25, -3.53, and -1.85%mm-1, respectively, for "Normal Sensitivity", and -2.89, -2.39, -4.54, -3.12, -6.24, and -4.11% mm-1, respectively, for "High Sensitivity", showing significant better accuracy for "Normal Sensitivity" than "High Sensitivity". Our results showed that 3DVH had some residual error for both sensitivities. Furthermore, we found that "Normal Sensitivity" might have better accuracy for the DVH metric for the PTV and that "High Sensitivity" might have better accuracy for DVH metrics for the rectum and bladder. We must be willing to tolerate this residual error in clinical care.


Assuntos
Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Radiometria/normas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/normas , Humanos , Japão , Masculino , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...