Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
ESC Heart Fail ; 11(1): 155-166, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37864482

RESUMO

AIMS: MicroRNAs play a role in pathogenic mechanisms leading to heart failure. We measured a panel of 754 miRNAs in the myocardial tissue and in the serum of patients with heart failure with reduced ejection fraction due to dilatative idiopathic cardiomyopathy (DCM, N = 10) or ischaemic cardiomyopathy (N = 3), referred to left ventricular assist device implant. We aim to identify circulating miRNAs with high tissue co-expression, significantly associated to echocardiographic and haemodynamic measures. METHODS AND RESULTS: We have measured a panel of 754 miRNAs in the myocardial tissue [left ventricular (LV) apex] and in the serum obtained at the same time in a well selected study population of end-stage heart failure with reduced ejection fraction due to either DCM or ischaemic cardiomyopathy, referred to continuous flow left ventricular assist device implant. We observed moderate agreement for miR-30d, miR-126-3p, and miR-483-3p. MiR-30d was correlated to LV systolic as well as diastolic volumes (r = 0.78, P = 0.001 and r = 0.80, P = 0.005, respectively), while miR-126-3p was associated to mPAP and PCWP (r = -0.79, P = 0.007 and r = -0.80, P = 0.005, respectively). Finally, serum miR-483-3p had an association with right ventricular end diastolic diameter (r = -0.73, P = 0.02) and central venous pressure (CVP) (r - 0.68 p 0.03). CONCLUSIONS: In patients with DCM, few miRNAs are co-expressed in serum and tissue: They are related to LV remodelling (miR-30d), post-capillary pulmonary artery pressure (miR-126-3p), and right ventricular remodelling/filling pressures (miR-483-3p). Further studies are needed to confirm their role in diagnosis, prognosis or as therapeutic targets in heart failure with reduced ejection fraction.


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Hipertensão Pulmonar , MicroRNAs , Isquemia Miocárdica , Disfunção Ventricular Esquerda , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/genética , MicroRNAs/genética , Remodelação Ventricular
2.
J Clin Med ; 12(15)2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37568531

RESUMO

For patients with chronic liver disease (CLD), telemedicine is emerging as a useful tool to prevent liver decompensation or hospitalization, allowing access to and the decentralization of care, even for patients with limited resources. However, research and attendant evidence are still lacking; thus, this review aims to systematically explore the topic of telemonitoring for CLD to describe the currently used tools and clinical outcomes. The review was conducted by using key terms on PubMed/EMBASE and searching for observational studies or clinical trials (according to PRISMA recommendations) that were published between 6 April 2013 and 6 April 2023 to keep the technological framework limited to the last 10 years. The studies were described and grouped according to the aim of telemonitoring, the underlying disease, and the tools adopted to achieve remote monitoring. A total of 32 articles met the inclusion criteria. Of these, 11 articles report the successful use of a telehealth program to support and improve access to care in the management of HCV-related cirrhosis, eight articles examine the efficacy of telemedicine for remote monitoring interventions to prevent or decrease the risk of decompensation in high-risk patients, and five articles examine improvements in the physical performance and quality of life of cirrhotic patients through telehealth rehabilitation programs. Four studies were completed during the recent COVID-19 pandemic. Telehealth has the potential to provide and expand treatment access and reduce barriers to care for the most disadvantaged patients and might be able to reduce the need for hospital readmission for CLD, though most practice to test feasibility is still in the pilot stage.

3.
Eur J Heart Fail ; 19(7): 926-946, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28371221

RESUMO

Right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation is associated with increased morbidity and mortality, but the identification of LVAD candidates at risk for RVF remains challenging. We undertook a systematic review and meta-analysis of observational studies of risk factors associated with RVF after LVAD implant. Thirty-six studies published between 1 January 1995 and 30 April 2015, comprising 995 RVF patients out of a pooled final population of 4428 patients, were identified. Meta-analysed prevalence of post-LVAD RVF was 35%. A need for mechanical ventilation [odds ratio (OR) 2.99], or continuous renal replacement therapy (CRRT; OR 4.61, area under the curve 0.78, specificity 0.91) were the clinical variables with the highest effect size (ES) in predicting RVF. International normalized ratio [INR; standardized mean difference (SMD) 0.49] and N-terminal pro-brain natriuretic peptide (NT-proBNP) (SMD 0.52) were the biochemical markers that best discriminated between RVF and No-RVF populations, though NT-proBNP was highly heterogeneous. Right ventricular stroke work index (RVSWI) and central venous pressure (CVP) (SMD -0.58 and 0.47, respectively) were the haemodynamic measures with the highest ES in identifying patients at risk of post-LVAD RVF; CVP was particularly useful in risk stratifying patients undergoing continuous-flow LVAD implant (SMD 0.59, P < 0.001, I2 = 20.9%). Finally, pre-implant moderate to severe right ventricular (RV) dysfunction, as assessed qualitatively (OR 2.82), or a greater RV/LV diameter ratio (SMD 0.51) were the standard echocardiographic measurements with the highest ES in comparing RVF with No-RVF patients. Longitudinal systolic strain of the RV free wall had the highest ES (SMD 0.73) but also the greatest heterogeneity (I2 = 74%) and was thus only marginally significant (P = 0.05). Patients on ventilatory support or CRRT are at high risk for post-LVAD RVF, similarly to patients with slightly increased INR, high NT-proBNP or leukocytosis. High CVP, low RVSWI, an enlarged right ventricle with concomitant low RV strain also identify patients at higher risk.


Assuntos
Cardiomiopatias/cirurgia , Insuficiência Cardíaca , Coração Auxiliar/efeitos adversos , Estudos Observacionais como Assunto , Saúde Global , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Prognóstico , Taxa de Sobrevida/tendências , Falha de Tratamento
4.
Artif Organs ; 41(9): E92-E102, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28185277

RESUMO

Bicuspid aortic valve (BAV)-associated ascending aneurysmal aortopathy (namely "bicuspid aortopathy") is a heterogeneous disease making surgeon predictions particularly challenging. Computational flow analysis can be used to evaluate the BAV-related hemodynamic disturbances, which likely lead to aneurysm enlargement and progression. However, the anatomic reconstruction process is time consuming so that predicting hemodynamic and structural evolution by computational modeling is unfeasible in routine clinical practice. The aim of the study was to design and develop a parametric program for three-dimensional (3D) representations of aneurysmal aorta and different BAV phenotypes starting from several measures derived by computed-tomography angiography (CTA). Assuming that wall shear stress (WSS) has an important implication on bicuspid aortopathy, computational flow analyses were then performed to estimate how different would such an important parameter be, if a parametric aortic geometry was used as compared to standard geometric reconstructions obtained by CTA scans. Morphologic parameters here documented can be used to rapidly model the aorta and any phenotypes of BAV. t-test and Bland-Altman plot demonstrated that WSS obtained by flow analysis of parametric aortic geometries was in good agreement with that obtained from the flow analysis of CTA-related geometries. The proposed program offers a rapid and automated tool for 3D anatomic representations of bicuspid aortopathy with promising application in routine clinical practice by reducing the amount of time for anatomic reconstructions.


Assuntos
Aorta/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/diagnóstico por imagem , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Idoso , Aorta/anormalidades , Aneurisma Aórtico/etiologia , Valva Aórtica/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide , Biologia Computacional , Angiografia por Tomografia Computadorizada/métodos , Eletrocardiografia/métodos , Feminino , Hemodinâmica , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Software , Estresse Mecânico
9.
Proc Inst Mech Eng H ; 230(1): 71-4, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26586524

RESUMO

Dilated cardiomyopathy is a heart disease characterized by both left ventricular dilatation and left ventricular systolic dysfunction, leading to cardiac remodeling and ultimately heart failure. We aimed to investigate the effect of dilated cardiomyopathy on the pump performance and myocardial wall mechanics using patient-specific finite element analysis. Results evinced pronounced end-systolic wall stress on left ventricular wall of patients with dilated cardiomyopathy as compared to that of normal hearts. In dilated cardiomyopathy, both end-diastolic and end-systolic pressure-volume relationships of left ventricle and right ventricle were shifted to the right compared to controls, suggesting reduced myocardial contractility. We hereby propose that finite element analysis represents a useful tool to assess the myocardial wall stress and cardiac work, which are responsible for progressive left ventricular deterioration and poor clinical course.


Assuntos
Pressão Sanguínea/fisiologia , Cardiomiopatia Dilatada/fisiopatologia , Ventrículos do Coração/fisiopatologia , Idoso , Estudos de Coortes , Análise de Elementos Finitos , Coração/fisiopatologia , Humanos , Pessoa de Meia-Idade , Modelos Cardiovasculares
10.
J Endovasc Ther ; 23(1): 172-81, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26496956

RESUMO

PURPOSE: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. METHODS: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. RESULTS: The bird-beak configuration with the greatest protrusion extension exhibited the maximum TAG device displacement (1.66 mm), while the lowest protrusion extension configuration led to the minimum amount of both displacement and rotation parameters (0.25 mm and 0.6°, respectively). A positive relationship was found between the infolding parameters and the flow circulating in the aorta and left subclavian artery. Similarly, TAG device displacement was positively and significantly (p<0.05) correlated with the pulse pressure for all bird-beak configurations and device sizes. However, no collapse was observed under chronic perfusion testing maintained for 30 days and pulse pressure of 100 mm Hg. CONCLUSION: These findings suggest that endograft infolding depends primarily on the amount of aortic pulsatility and flow rate and that physiological flows do not necessarily engender hemodynamic loads on the proximal bird-beak segment sufficient to cause TAG collapse. Hemodynamic variables may allow for identification of patients at high risk of endograft infolding and help guide preventive intervention to avert its occurrence.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Hemodinâmica , Modelos Anatômicos , Modelos Cardiovasculares , Falha de Prótese , Stents , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aortografia , Procedimentos Endovasculares/efeitos adversos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/fisiopatologia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Desenho de Prótese , Fluxo Pulsátil , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
11.
Med Eng Phys ; 38(2): 121-30, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26669606

RESUMO

Ascending thoracic aortic aneurysm (ATAA) has been associated with diminished biomechanical strength and disruption in the collagen fiber microarchitecture. Additionally, the congenital bicuspid aortic valve (BAV) leads to a distinct extracellular matrix structure that may be related to ATAA development at an earlier age than degenerative aneurysms arising in patients with the morphological normal tricuspid aortic valve (TAV). The purpose of this study was to model the fiber-reinforced mechanical response of ATAA specimens from patients with either BAV or TAV. This was achieved by combining image-analysis derived parameters of collagen fiber dispersion and alignment with tensile testing data. Then, numerical simulations were performed to assess the role of anisotropic constitutive formulation on the wall stress distribution of aneurysmal aorta. Results indicate that both BAV ATAA and TAV ATAA have altered collagen fiber architecture in the medial plane of experimentally-dissected aortic tissues when compared to normal ascending aortic specimens. The study findings highlight that differences in the collagen fiber distribution mostly influences the resulting wall stress distribution rather than the peak stress. We conclude that fiber-reinforced constitutive modeling that takes into account the collagen fiber defect inherent to the aneurysmal ascending aorta is paramount for accurate finite element predictions and ultimately for biomechanical-based indicators to reliably distinguish the more from the less 'malignant' ATAAs.


Assuntos
Aorta/patologia , Aneurisma da Aorta Torácica/patologia , Fenômenos Mecânicos , Modelos Biológicos , Aorta/metabolismo , Aneurisma da Aorta Torácica/metabolismo , Fenômenos Biomecânicos , Colágeno/metabolismo , Análise de Elementos Finitos , Humanos , Estresse Mecânico , Resistência à Tração
12.
Eur J Intern Med ; 26(10): 830-4, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26525531

RESUMO

BACKGROUND: Cirrhotic cardiomyopathy has been characterized by impaired contractile response to stress and/or altered diastolic relaxation, with electrophysiological abnormalities in the absence of known cardiac disease. However, the clinical significance of diastolic dysfunction (DDF) in cirrhotic patients has not been clarified. METHODS: We studied 84 cirrhotic patients with normal systolic function to evaluate the prevalence of DDF using tissue Doppler imaging, and to investigate the possible correlation of DDF with outcomes (hospitalization, death) and with the specific causes of death. RESULTS: The mean follow-up was 10±8months. DDF was diagnosed in 22 patients (26.2%). Patients with DDF more frequently had ascites (90.9% vs. 64.5 %; p=0.026), lower levels of albumin (OR: 5.39; p=0.004), higher NT-proBNP levels, and longer QTc interval (464±23ms vs. 452±30ms; p=0.039). At follow-up, patients with DDF did not have a higher incidence of adverse events in terms of hospitalization and death. CONCLUSIONS: The presence of diastolic dysfunction has not been found to be clearly associated with outcome, and prognosis has been determined primarily by the severity of liver disease.


Assuntos
Pressão Sanguínea , Cardiomiopatias , Ecocardiografia Doppler , Cirrose Hepática , Disfunção Ventricular Esquerda , Adulto , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/etiologia , Cardiomiopatias/prevenção & controle , Ecocardiografia Doppler/métodos , Ecocardiografia Doppler/estatística & dados numéricos , Eletrocardiografia/métodos , Feminino , Humanos , Itália/epidemiologia , Cirrose Hepática/sangue , Cirrose Hepática/complicações , Cirrose Hepática/mortalidade , Cirrose Hepática/fisiopatologia , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Avaliação de Resultados em Cuidados de Saúde , Fragmentos de Peptídeos/sangue , Valor Preditivo dos Testes , Prevalência , Prognóstico , Índice de Gravidade de Doença , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia
13.
PLoS One ; 10(11): e0142103, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26556804

RESUMO

BACKGROUND AND AIMS: Compensatory renal hypertrophy following unilateral nephrectomy (UNX) occurs in the remaining kidney. However, the long-term cardiac adaptive process to UNX remains poorly defined in humans. Our goal was to characterize myocardial structure and function in living kidney donors (LKDs), approximately 12 years after UNX. METHODS AND RESULTS: Cardiac function and structure in 15 Italian LKDs, at least 5 years after UNX (median time from donation = 8.4 years) was investigated and compared to those of age and sex matched U.S. citizens healthy controls (n = 15). Standard and speckle tracking echocardiography (STE) was performed in both LKDs and controls. Plasma angiotensin II, aldosterone, atrial natriuretic peptide (ANP), N terminus pro B-type natriuretic peptide (NT-proBNP), cyclic guanylyl monophosphate (cGMP), and amino-terminal peptide of procollagen III (PIIINP) were also collected. Median follow-up was 11.9 years. In LKDs, LV geometry and function by STE were similar to controls, wall thickness and volumes were within normal limits also by CMR. In LKDs, CMR was negative for myocardial fibrosis, but apical rotation and LV torsion obtained by STE were impaired as compared to controls (21.4 ± 7.8 vs 32.7 ± 8.9 degrees, p = 0.04). Serum creatinine and PIIINP levels were increased [1.1 (0.9-1.3) mg/dL, and 5.8 (5.4-7.6)] µg/L, respectively), while urinary cGMP was reduced [270 (250-355) vs 581 (437-698) pmol/mL] in LKDs. No LKD developed cardiovascular or renal events during follow-up. CONCLUSIONS: Long-term kidney donors have no apparent structural myocardial abnormalities as assessed by contrast enhanced CMR. However, myocardial deformation of the apical segments, as well as apical rotation, and LV torsion are reduced. The concomitant increase in circulating PIIINP level is suggestive of fibrosis. Further studies, focused on US and EU patients are warranted to evaluate whether these early functional modifications will progress to a more compromised cardiac function and structure at a later time.


Assuntos
Coração/anatomia & histologia , Coração/fisiologia , Transplante de Rim , Doadores Vivos , Idoso , Aldosterona/sangue , Angiotensina II/sangue , Fator Natriurético Atrial/sangue , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Projetos Piloto , Pró-Colágeno/sangue
14.
Dig Liver Dis ; 47(12): 1052-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26427586

RESUMO

BACKGROUND: Cirrhotic cardiomyopathy may lead to heart failure in stressful circumstances, such as after transjugular intrahepatic portosystemic shunt (TIPS) placement. AIM: To examine whether acute volume expansion predicts haemodynamic changes after TIPS and elicits signs of impending heart failure. METHODS: We prospectively evaluated refractory ascites patients (group A) and compensated cirrhotics (group B), who underwent echocardiography, NT-proBNP measurement, and heart catheterization before and after volume load; group A repeated measurements after TIPS. RESULTS: 15 patients in group A (80% male; 54±12.4 years) and 8 in group B (100% male; 56±6.2 years) were enrolled. Echocardiography disclosed diastolic dysfunction in 30% and 12.5%, respectively. In group A, volume load and TIPS induced a significant increase in right atrial, mean pulmonary, capillary wedge pressure and cardiac index, and a decrease in systemic vascular resistance (respectively, 4.7±2.8 vs. 9.9±3.6 mmHg; 13.3±3.5 vs. 21.9±5.9 mmHg; 8.3±3.4 vs. 15.4±4.7 mmHg; 3.7±0.7 vs. 4.6±11 t/min/m2; 961±278 vs. 767±285 dynscm(-5); and 10.1±3.3 vs. 14.2±3.4 mmHg; 17.5±4 vs. 25.2±4.2 mmHg; 12.3±4 vs. 19.3±3.4 mmHg; 3.4±0.8 vs. 4.5±0.91l t/min/m2; 779±62 vs. 596±199 dynscm(-5), p<0.001 for all pairs). At 24h, cardiopulmonary pressures returned towards baseline. CONCLUSIONS: Acute volume expansion predicted haemodynamic changes immediately after TIPS. All patients had adequate haemodynamic adaptation to TIPS; none developed signs of heart failure.


Assuntos
Ascite/cirurgia , Insuficiência Cardíaca Diastólica/diagnóstico , Hemodinâmica , Cirrose Hepática/complicações , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Adulto , Idoso , Cateterismo Cardíaco , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Estudos Prospectivos , Espanha , Resistência Vascular
15.
Comput Biol Med ; 66: 235-41, 2015 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-26433455

RESUMO

Endografts placed in the aorta for thoracic endovascular aortic repair (TEVAR) may determine malappositioning to the lesser curvature of the aortic wall, thus resulting in a devastating complication known as endograft collapse. This premature device failure commonly occurs in young individuals after TEVAR for traumatic aortic injuries as a result of applications outside the physical conditions for which the endograft was designed. In this study, an experimentally-calibrated fluid-structure interaction (FSI) model was developed to assess the hemodynamic and stress/strain distributions acting on the excessive protrusion extension (PE) of endografts deployed in four young patients underwent TEVAR. Endograft infolding was experimentally measured for different hemodynamic scenarios by perfusion testing and then used to numerically calibrate the mechanical behavior of endograft PE. Results evinced that the extent of endograft can severely alter the hemodynamic and structural loads exerted on the endograft PE. Specifically, PE determined a physiological aortic coarctation into the aortic arch characterized by a helical flow in the distal descending aorta. High device displacement and transmural pressure across the stent-graft wall were found for a PE longer than 21 mm. Finally, marked intramural stress and principal strain distributions on the protruded segment of the endograft wall may suggest failure due to material fatigue. These critical parameters may contribute to the endograft collapse observed clinically and can be used to design new devices more suitable for young individuals to be treated with an endoprosthesis for TEVAR of blunt traumatic aortic injuries.


Assuntos
Aorta Torácica/patologia , Aneurisma da Aorta Torácica/patologia , Prótese Vascular , Procedimentos Endovasculares/métodos , Adulto , Algoritmos , Aorta Torácica/diagnóstico por imagem , Implante de Prótese Vascular , Calibragem , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Radiografia , Stents , Estresse Mecânico , Adulto Jovem
16.
Proc Inst Mech Eng H ; 229(3): 205-14, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25833996

RESUMO

Pericardial effusion is a pathological accumulation of fluid within pericardial cavity, which may compress heart chambers with hemodynamic impairment. We sought to determine the mechanics underlying the physiology of the hemodynamic impairment due to pericardial effusion using patient-specific computational modeling. Computational models of left ventricle and right ventricle were based on magnetic resonance images obtained from patients with pericardial effusion and controls. Myocardial material parameters were adjusted, so that volumes of ventricular chambers and pericardial effusion agreed with magnetic resonance imaging data. End-diastolic and end-systolic pressure-volume relationships as well as stroke volume were determined to evaluate impaired cardiac function of biventricular model. Distributions of myocardial fiber stresses and their regional variation along left ventricular wall were compared between patient groups. Both end-diastolic and end-systolic pressure-volume relationships shifted to the left for patients with pericardial effusion, with right ventricle diastolic filling particularly restricted. Left ventricle function as estimated by Starling curve was reduced by pericardial effusion. End-systolic fiber stress of left ventricle was significantly reduced as compared to that found for healthy patients. Myocardial stress was found increased at interventricular septum when compared to that exerted at lateral wall of left ventricle. Right ventricular myocardial stress was reduced as a consequence of the pressure equalization between right ventricle and pericardial effusion. Diastolic right ventricle collapse in patients with pericardial effusion is related to higher myocardial fiber stress on interventricular septum and to an extensible pericardium reducing motion of ventricular chambers, with right ventricle particularly restrained. These findings likely portend progression of pericardial effusion to cardiac tamponade.


Assuntos
Modelos Cardiovasculares , Derrame Pericárdico/patologia , Derrame Pericárdico/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Tamponamento Cardíaco/patologia , Tamponamento Cardíaco/fisiopatologia , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Adulto Jovem
19.
J Biomech ; 46(10): 1729-38, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23664314

RESUMO

The aortic dissection (AoD) of an ascending thoracic aortic aneurysm (ATAA) initiates when the hemodynamic loads exerted on the aneurysmal wall overcome the adhesive forces holding the elastic layers together. Parallel coupled, two-way fluid-structure interaction (FSI) analyses were performed on patient-specific ATAAs obtained from patients with either bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) to evaluate hemodynamic predictors and wall stresses imparting aneurysm enlargement and AoD. Results showed a left-handed circumferential flow with slower-moving helical pattern in the aneurysm's center for BAV ATAAs whereas a slight deviation of the blood flow toward the anterolateral region of the ascending aorta was observed for TAV ATAAs. Blood pressure and wall shear stress were found key hemodynamic predictors of aneurysm dilatation, and their dissimilarities are likely associated to the morphological anatomy of the aortic valve. We also observed discontinues, wall stresses on aneurysmal aorta, which was modeled as a composite with two elastic layers (i.e., inhomogeneity of vessel structural organization). This stress distribution was caused by differences on elastic material properties of aortic layers. Wall stress distribution suggests AoD just above sinotubular junction. Moreover, abnormal flow and lower elastic material properties that are likely intrinsic in BAV individuals render the aneurysm susceptible to the initiation of AoD.


Assuntos
Aorta Torácica/fisiopatologia , Aneurisma Aórtico/fisiopatologia , Doenças das Valvas Cardíacas/fisiopatologia , Valva Tricúspide/fisiopatologia , Idoso , Valva Aórtica/anormalidades , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Circulação Coronária , Elasticidade , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares
20.
Cardiovasc Revasc Med ; 11(4): 264.e9-11, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20934666

RESUMO

A case of profound systemic oxygen desaturation after atrial septostomy in a patient with primitive pulmonary hypertension is reported. A new method to correct such severe complication of atrial septostomy is described, consisting in a graded reduction of the right to left atrial shunt by deployment of a manually perforated atrial septal closure device.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateterismo/efeitos adversos , Septos Cardíacos/cirurgia , Hipertensão Pulmonar/terapia , Hipóxia/terapia , Dispositivo para Oclusão Septal , Adulto , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Oxigenação por Membrana Extracorpórea , Hemodinâmica , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Hipóxia/etiologia , Hipóxia/fisiopatologia , Masculino , Desenho de Prótese , Punções , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...