Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 10: 1125110, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37283581

RESUMO

Introduction: Thoracic endovascular aortic repair (TEVAR) of the arch is challenging given its complex geometry and the involvement of supra-aortic arteries. Different branched endografts have been designed for use in this region, but their haemodynamic performance and the risk for post-intervention complications are not yet clear. This study aims to examine aortic haemodynamics and biomechanical conditions following TVAR treatment of an aortic arch aneurysm with a two-component single-branched endograft. Methods: Computational fluid dynamics and finite element analysis were applied to a patient-specific case at different stages: pre-intervention, post-intervention and follow-up. Physiologically accurate boundary conditions were used based on available clinical information. Results: Computational results obtained from the post-intervention model confirmed technical success of the procedure in restoring normal flow to the arch. Simulations of the follow-up model, where boundary conditions were modified to reflect change in supra-aortic vessel perfusion observed on the follow-up scan, predicted normal flow patterns but high levels of wall stress (up to 1.3M MPa) and increased displacement forces in regions at risk of compromising device stability. This might have contributed to the suspected endoleaks or device migration identified at the final follow up. Discussion: Our study demonstrated that detailed haemodynamic and biomechanical analysis can help identify possible causes for post-TEVAR complications in a patient-specific setting. Further refinement and validation of the computational workflow will allow personalised assessment to aid in surgical planning and clinical decision making.

2.
J Thorac Cardiovasc Surg ; 166(1): 11-21.e1, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-34217540

RESUMO

BACKGROUND: The geometrical characterization of ascending thoracic aortic aneurysms in clinical practice is limited to diameter measurements. Despite growing interest in hemodynamic assessment, its relationship with ascending thoracic aortic aneurysm pathogenesis is poorly understood. This study examines the relationship between geometry of the ventriculo-aortic junction and blood flow patterns in ascending thoracic aortic aneurysm disease. METHODS: Thirty-three patients with ascending thoracic aortic aneurysms (exclusions: bicuspid aortic valves, connective tissue disease) underwent 4-dimensional flow magnetic resonance imaging. After image segmentation, geometrical parameters were measured, including aortic curvature, tortuosity, length, and diameter. A unique angular measurement made by the trajectory of the left ventricular outflow tract axis and the proximal aorta was also conducted. Velocity profiles were quantitatively and qualitatively analyzed. In addition, 11 patients (33%) underwent wall shear stress mapping of the ascending thoracic aortic aneurysm region using computational fluid dynamics simulation. RESULTS: Greater left ventricular outflow tract aortic angles were associated with larger aortic diameters at the levels of the sinus (coefficient = 0.387, P = .014) and ascending aorta (coefficient = 0.284, P = .031). Patients with left ventricular outflow tract aortic angles greater than 60° had marked asymmetric flow acceleration on the outer curvature in the proximal aorta, ascertained from 4-dimensional flow analysis. For patients undergoing computational fluid dynamics assessment, regression analysis found that higher left ventricular outflow tract aortic angles were associated with significantly higher wall shear stress values in the outer curve of the aorta (coefficient 0.07, 95% confidence interval 0.04-0.11, P = .002): Angles greater than 50° yielded time-averaged wall shear stress values greater than 2.5 Pa, exhibiting a linear relationship. CONCLUSIONS: Our findings strengthen the hypothesis of flow-mediated ascending thoracic aortic aneurysm disease progression and that left ventricular outflow tract aortic angle may be a predictor of disease severity.


Assuntos
Aneurisma da Aorta Ascendente , Humanos , Aorta/diagnóstico por imagem , Aneurisma Aórtico , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/complicações , Valva Aórtica , Hemodinâmica/fisiologia , Estresse Mecânico
3.
Bioengineering (Basel) ; 9(10)2022 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-36290541

RESUMO

Thoracic endovascular aortic repair (TEVAR) of aortic aneurysms and dissections involving the arch has evolved over the last two decades. Compared to conventional surgical methods, endovascular repair offers a less invasive treatment option with lower risk and faster recovery. Endografts used in TEVAR vary in design depending on the procedure and application. Novel endografts (e.g., branched stent-graft) were developed to ensure perfusion of blood to the supra-aortic vessels, but their haemodynamic performance and long-term durability have not been adequately studied. This review focuses on the use of computational modelling to study haemodynamics in commercially available endografts designed for complex aortic arch repair. First, we summarise the currently adopted workflow for computational fluid dynamics (CFD) modelling, including geometry reconstruction, boundary conditions, flow models, and haemodynamic metrics of interest. This is followed by a review of recently (2010-present) published CFD studies on complex aortic arch repair, using both idealized and patient-specific models. Finally, we introduce some of the promising techniques that can be potentially applied to predict post-operative outcomes.

4.
Bioengineering (Basel) ; 9(2)2022 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-35200399

RESUMO

This study aims to investigate the haemodynamic response induced by implantation of a double-branched endograft used in thoracic endovascular aortic repair (TEVAR) of the aortic arch. Anatomically realistic models were reconstructed from CT images obtained from patients who underwent TEVAR using the RelayPlus double-branched endograft implanted in the aortic arch. Two cases (Patient 1, Patient 2) were included here, both patients presented with type A aortic dissection before TEVAR. To examine the influence of inner tunnel branch diameters on localised flow patterns, three tunnel branch diameters were tested using the geometric model reconstructed for Patient 1. Pulsatile blood flow through the models was simulated by numerically solving the Navier-Stokes equations along with a transitional flow model. The physiological boundary conditions were imposed at the model inlet and outlets, while the wall was assumed to be rigid. Our simulation results showed that the double-branched endograft allowed for the sufficient perfusion of blood to the supra-aortic branches and restored flow patterns expected in normal aortas. The diameter of tunnel branches in the device plays a crucial role in the development of flow downstream of the branches and thus must be selected carefully based on the overall geometry of the vessel. Given the importance of wall shear stress in vascular remodelling and thrombus formation, longitudinal studies should be performed in the future in order to elucidate the role of tunnel branch diameters in long-term patency of the supra-aortic branches following TEVAR with the double-branched endograft.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...