Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(22)2022 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-36433565

RESUMO

In ultrahigh-field (UHF) magnetic resonance imaging (MRI) system, the RF power required to excite the nuclei of the target object increases. As the strength of the main magnetic field (B0 field) increases, the improvement of the RF transmit field (B1+ field) efficiency and receive field (B1- field) sensitivity of radio-frequency (RF) coils is essential to reduce their specific absorption rate and power deposition in UHF MRI. To address these problems, we previously proposed a method to simultaneously improve the B1+ field efficiency and B1- field sensitivity of 16-leg bandpass birdcage RF coils (BP-BC RF coils) by combining a multichannel wireless RF element (MCWE) and segmented cylindrical high-permittivity material (scHPM) comprising 16 elements in 7.0 T MRI. In this work, we further improved the performance of transmit/receive RF coils. A new combination of RF coil with wireless element and HPM was proposed by comparing the BP-BC RF coil with the MCWE and the scHPM proposed in the previous study and the multichannel RF coils with a birdcage RF coil-type wireless element (BCWE) and the scHPM proposed in this study. The proposed 16-ch RF coils with the BCWE and scHPM provided excellent B1+ field efficiency and B1- field sensitivity improvement.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Campos Magnéticos , Núcleo Celular
2.
Sensors (Basel) ; 22(11)2022 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-35684895

RESUMO

The optimized size of a single-channel surface radio frequency (RF) coil for mouse body images in a 9.4 T magnetic resonance imaging (MRI) system was determined via electromagnetic-field analysis of the signal depth according to the size of a single-channel coil. The single-channel surface RF coils used in electromagnetic field simulations were configured to operate in transmission/reception mode at a frequency of 9.4 T-400 MHz. Computational analysis using the finite-difference time-domain method was used to assess the single-channel surface RF coil by comparing single-channel surface RF coils of varying sizes in terms of |B1|-, |B1+|-, |B1-|- and |E|-field distribution. RF safety for the prevention of burn injuries to small animals was assessed using an analysis of the specific absorption rate. A single-channel surface RF coil with a 20 mm diameter provided optimal B1-field distribution and RF safety, thus confirming that single-channel surface RF coils with ≥25 mm diameter could not provide typical B1-field distribution. A single-channel surface RF coil with a 20 mm diameter for mouse body imaging at 9.4 T MRI was recommended to preserve the characteristics of single-channel surface RF coils, and ensured that RF signals were applied correctly to the target point within RF safety guidelines.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Simulação por Computador , Campos Eletromagnéticos , Imageamento por Ressonância Magnética/métodos , Camundongos , Imagens de Fantasmas
3.
Sensors (Basel) ; 22(5)2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-35270889

RESUMO

Improvements in transmission and reception sensitivities of radiofrequency (RF) coils used in ultra-high field (UHF) magnetic resonance imaging (MRI) are needed to reduce specific absorption rates (SAR) and RF power deposition, albeit without applying high-power RF. Here, we propose a method to simultaneously improve transmission efficiency and reception sensitivity of a band-pass birdcage RF coil (BP-BC RF coil) by combining a multi-channel wireless RF element (MCWE) with a high permittivity material (HPM) in a 7.0 T MRI. Electromagnetic field (EM-field) simulations, performed using two types of phantoms, viz., a cylindrical phantom filled with oil and a human head model, were used to compare the effects of MCWE and HPM on BP-BC RF coils. EM-fields were calculated using the finite difference time-domain (FDTD) method and analyzed using Matlab software. Next, to improve RF transmission efficiency, we compared two HPM structures, namely, a hollow cylinder shape HPM (hcHPM) and segmented cylinder shape HPM (scHPM). The scHPM and MCWE model comprised 16 elements (16-rad BP-BC RF coil) and this coil configuration demonstrated superior RF transmission efficiency and reception sensitivity along with an acceptable SAR. We expect wider clinical application of this combination in 7.0 T MRIs, which were recently approved by the United States Food and Drug Administration.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Campos Eletromagnéticos , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Software , Estados Unidos
4.
Sensors (Basel) ; 22(4)2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35214409

RESUMO

Magnetic resonance imaging (MRI) systems must undergo quantitative evaluation through daily and periodic performance assessments. In general, the reference or standard radiofrequency (RF) coils for these performance assessments of 1.5 to 7.0 T MRI systems have been low-pass-type birdcage (LP-BC) RF coils. However, LP-BC RF coils are inappropriate for use as reference RF coils because of their relatively lower magnetic field (B1-field) sensitivity than other types of BC RF coils, especially in ultrahigh-field (UHF) MRI systems above 3.0 T. Herein, we propose a hybrid-type BC (Hybrid-BC) RF coil as a reference RF coil with improved B1-field sensitivity in UHF MRI system and applied it to an 11.7 T MRI system. An electromagnetic field (EM-field) analysis on the Hybrid-BC RF coil was performed to provide the proper dimensions for its use as a reference RF coil. Commercial finite difference time-domain program was used in EM-field simulation, and home-made analysis programs were used in analysis. The optimal specifications of the proposed Hybrid-BC RF coils for them to qualify as reference RF coils are proposed based on their B1+-field sensitivity under unnormalized conditions, as well as by considering their B1+-field uniformity and RF safety under normalized conditions.


Assuntos
Campos Eletromagnéticos , Ondas de Rádio , Simulação por Computador , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
5.
PLoS One ; 14(7): e0219407, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31276549

RESUMO

The neuroimaging of humans using 7T magnetic resonance imaging (MRI) has been conducted using phased array (PA) coils with different numbers of receiving channels. PA coils with a high number of channels may offer parallel imaging (PI) with a high reduction (R)-factor, which is enabled via under-sampling and coil geometry (g) factor, increasing the radiofrequency signal sensitivity provided by a small coil. The goals of this study were to assess and validate the coil performance of PA coils with different numbers of receiver (Rx)-channels in and to propose the coil selection guidelines by visualizing 7T brain images. The combined magnetic flux density (||B1||) distributions of four configurations of PA coils-4-, 8-, 12-, and 16-channel Rx-only mode under the local transmit (Tx) mode of birdcage coils-were evaluated using electromagnetic (EM) calculations. These four configurations of PA coils and a local Tx coil were designed and built for a 7T MRI experiment. For 7T brain imaging experiments, all PA coils with (w/) and without (w/o) R-factors were compared in terms of signal-to-noise ratio (SNR) and spatial noise variation (SNV). EM simulation results clearly demonstrated that PA coils with a high number of Rx channels showed more homogeneously distributed ||B1|| fields than a PA coils with a low number of Rx coils. The results of this study demonstrate that a collection of smaller surface coils can contribute to high RF signal sensitivity in terms of the anatomical coverage of the brain and may facilitate PI. With further improvement in coil technology, researchers and clinicians will be provided with PA coils with different numbers of channels, which can ensure the optimum SNR and PI benefits for 7T brain MR imaging.


Assuntos
Imageamento por Ressonância Magnética , Modelos Teóricos , Neuroimagem , Razão Sinal-Ruído , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Neuroimagem/métodos , Neuroimagem/normas
6.
Magn Reson Med Sci ; 16(3): 253-258, 2017 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-27725573

RESUMO

The birdcage (BC) coil is currently being utilized for uniform radiofrequency (RF) transmit/receive (Tx/Rx) or Tx-only configuration in many magnetic resonance (MR) imaging applications, but insufficient magnetic flux (|B1|) density and their non-uniform distribution still exists in high-field (HF) environments. We demonstrate that the asymmetric birdcage (ABC) transmit/receive (Tx/Rx) volume coil, which is a modified standard birdcage (SBC) coil with the end ring split into two halves, is suitable for improving the |B1| sensitivity in 7T small-animal MR imaging. Cylindrical SBC and ABC coils with 35 mm diameter were constructed and bench tested for mouse body MR imaging at 300 MHz using a 7T scanner. To assess the ABC coil performance, computational electromagnetic (EM) simulation and 7T MR experiment were performed by using a cylindrical phantom and in vivo mouse body and quantitatively compared with the SBC coil in terms of |B1| distribution, RF transmit (|B1+|) field, and signal-to-noise ratio (SNR). The bench measurements of the two BC coils are similar, yielding a quality value (Q-value) of 74.42 for the SBC coil and 77.06 for the ABC coil. The computational calculation results clearly show that the proposed ABC coil offers superior |B1| field and |B1+| field sensitivity in the central axial slice compared with the SBC coil. There was also high SNR and uniformly distributed flip angle (FA) under the loaded condition of mouse body in the 7T experiment. Although ABC geometry allows a further increase in the |B1| field and |B1+| field sensitivity in only the central axial slice, the geometrical modification of the SBC coil can make a high performance RF coil feasible in the central axial slice and also make target imaging possible in the diagonal direction.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Animais , Simulação por Computador , Desenho de Equipamento , Camundongos , Imagens de Fantasmas , Ondas de Rádio , Razão Sinal-Ruído
7.
Scanning ; 38(6): 747-756, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27162104

RESUMO

In ultra-high field (UHF) imaging environments, it has been demonstrated that multiple-mouse magnetic resonance imaging (MM-MRI) is dependent on key factors such as the radiofrequency (RF) coil hardware, imaging protocol, and experimental setup for obtaining high-resolution MR images. A key aspect is the RF coil, and a number of MM-MRI studies have investigated the application of single-channel RF transmit (Tx)/receive (Rx) coils or multi-channel phased array (PA) coil configurations under a single gradient coil set. However, despite applying a variety of RF coils, Tx (|B1+ |)-field inhomogeneity still remains a major problem due to the relative shortening of the effective RF wavelength in the UHF environment. To address this issue, we propose a relatively smaller size of individual Tx-only coils in a multiple birdcage (MBC) coil for MM-MRI to image up to three mice. We use electromagnetic (EM) simulations in the finite-difference time-domain (FDTD) environment to obtain the |B1 |-field distribution. Our results clearly show that the single birdcage (SBC) high-pass filter (HPF) configuration, which is referred to as the SBCHPF , under the absence of an RF shield exhibits a high |B1 |-field intensity in comparison with other coil configurations such as the low-pass filter (LPF) and band-pass filter (BPF) configurations. In a 7-T MRI experiment, the signal-to-noise ratio (SNR) map of the SBCHPF configuration shows the highest coil performance compared to other coil configurations. The MBCHPF coil, which is comprised of a triple-SBCHPF configuration combined with additional decoupling techniques, is developed for simultaneous image acquisition of three mice. SCANNING 38:747-756, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Animais , Camundongos , Ondas de Rádio , Razão Sinal-Ruído
8.
Scanning ; 38(6): 515-524, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26780943

RESUMO

The purpose of this study was to combine a dual-Helmholtz (DH) transmit (Tx)-only coil and 12-channel receive (Rx)-only bended phased array (PA) coil to improve the magnetic flux (|B1 |) sensitivity in the superior-to-inferior (S-I) direction during human brain magnetic resonance imaging (MRI) at 7-T. The proposed coil combination was primarily implemented by electromagnetic (EM) simulation and compared with the 16-leg birdcage coil and 8-channel PA coil, which are generally used for the Tx- and Rx-only modes, respectively. The optimal coil combinations for the proposed structure were determined by |B1 | field calculations using the |BT+ | and |BR- | fields, which are respectively the transmit and receive components of the |B1 | field. The coil performance was then evaluated by a bench test and 7-T MRI experiment. The results of the computational calculations indicated that the |BT+ | field of the DH coil was distributed similarly to that of the 16-leg birdcage coil despite the fewer conducting legs of the former. However, the 12-channel Rx-only bended PA coil had clearly higher |BR- | profiles compared to the 8-channel PA coil. The results of the 7-T in vivo experiment showed that the proposed combination of the DH Tx-only coil and 12-channel Rx-only bended PA coil had better |B1 | field homogeneity in the sagittal slice as well as higher |B1 | field sensitivity during human brain MRI compared to an 8-channel Rx-only PA coil. SCANNING 38:515-524, © 2015 Wiley Periodicals, Inc.

9.
Scanning ; 37(5): 361-71, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25914270

RESUMO

The purpose of this study was to develop a new double-layer coupled (DLC) surface radiofrequency (RF) coil using a combination of single-layer planar (SLP) and single-layer circular (SLC) coils, for enhancement of magnetic flux (B1 ) sensitivity and RF penetration in 7 T rat-body magnetic resonance imaging (MRI). The proposed DLC surface coil was fabricated according to an electromagnetic (EM) simulation and validated based on the B1 distribution and bench measurements. The DLC coil performance was quantitatively evaluated based on the signal-to-noise ratio (S/N) and coil-response signal intensity curves in phantom and in vivo rat-body images. In the computational EM calculation and 7 T in vivo experimental results, the DLC surface coil clearly showed an increased S/N and higher RF transmit (B1 (+) ) profiles, compared to those of the SLP and SLC coils. While all surface coils displayed a rapid decrease in the MR signal from the near-coil region to the subject, the results reveal that the DLC coil concept may be used to provide sufficient RF penetration and high S/N and degrees of freedom for use in partial body imaging for 7 T ultra-high-field small-animal MRI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...