Vet Rec ; 181(21): 565, 2017 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-28986387

RESUMO

This study was conducted to establish normal reference range for the Schirmer tear test (STT) and intraocular pressure (IOP) in clinically normal donkeys for use in clinical practice. Sixteen adult Ethiopian domestic donkeys were used in this study. Complete ophthalmic examinations were performed without chemical restraint. STT values were evaluated in both eyes of all donkeys using a commercial STT strip. IOP was measured in both eyes with a Tono-Pen Vet (Reichert. USA) without using regional nerve blocks. STT values for all eyes (n=32) were 22.1±6.9 mm/minute with a range of 13-35 mm/minute. Comparison of mean STT values between right (n=16) and left eyes (n=16) showed no differences (P=0.6). Mean ±sd IOP values by applanation tonometry were 17.8±3.7 mmHg (range 13.5-24.5 mmHg). Comparison of mean IOP values between right (n=16) and left eyes (n=16) showed no differences (P=0.7). This initial survey provides means and ranges for IOP and STT values in donkeys. These data will assist veterinary ophthalmologists in more accurate diagnosis and management of ophthalmic diseases in donkeys, including keratoconjunctivitis sicca and glaucoma.


Assuntos
Equidae/fisiologia , Pressão Intraocular/fisiologia , Oftalmologia/métodos , Lágrimas/metabolismo , Tonometria Ocular/veterinária , Animais , Olho , Feminino , Masculino , Oftalmologia/normas , Valores de Referência , Tonometria Ocular/normas
SELEÇÃO DE REFERÊNCIAS