RESUMO
OBJECTIVE: To determine the malignancy risk of isolated macrocalcifications (a calcified nodule with complete posterior acoustic shadowing) detected on ultrasonography (US) and to evaluate the postoperative American Thyroid Association (ATA) risk stratification of malignant tumors manifesting as isolated macrocalcifications. MATERIALS AND METHODS: A total of 3852 thyroid nodules (≥ 1 cm) of 3061 consecutive patients who had undergone biopsy between January 2011 and June 2018 were included in this study. We assessed the prevalence, malignancy rate, and size distribution of isolated macrocalcifications and evaluated the histopathologic features and postoperative ATA risk stratification of malignant tumors manifesting as isolated macrocalcifications. RESULTS: Isolated macrocalcifications were found in 38 (1.2%) of the 3061 patients. Final diagnosis was established in 30 (78.9%) nodules; seven malignant tumors were diagnosed as papillary thyroid carcinomas (PTCs). The malignancy rate of the isolated macrocalcifications was 23.3% in the 30 nodules with final diagnoses and 18.4% in all nodules. Among the six surgically-treated malignant tumors, five (83.3%) had an extrathyroidal extension (ETE) (minor ETE 1, gross ETE 4), and two (33.3%) had macroscopic lymph node metastasis. Four (66.7%) malignant tumors were categorized as high-risk tumors, one as an intermediate-risk tumor, and one as a low-risk tumor using the ATA risk stratification. Histopathologically, out of the six malignant tumors, ossifications were noted in four (66.7%) and predominant calcifications in two (33.3%). CONCLUSION: The US pattern of isolated macrocalcifications (≥ 1 cm) showed an intermediate malignancy risk (at least 18.4%). All malignant tumors were PTCs, and most showed an aggressive behavior and a high or intermediate postoperative ATA risk.
Assuntos
Calcinose/patologia , Câncer Papilífero da Tireoide/patologia , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia , Ultrassonografia/métodos , Adulto , Idoso , Biópsia por Agulha Fina , Feminino , Humanos , Metástase Linfática/patologia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Medição de Risco , Estados UnidosRESUMO
OBJECTIVE: To investigate the effects of different types of mammography equipment on screening outcomes by comparing the performance of film-screen mammography (FSM), computed radiography mammography (CRM), and digital mammography (DM). MATERIALS AND METHODS: We retrospectively enrolled 128756 sets of mammograms from 10 hospitals participating in the Alliance for Breast Cancer Screening in Korea between 2005 and 2010. We compared the diagnostic accuracy of the types of mammography equipment by analyzing the area under the receiver operating characteristic curve (AUC) with a 95% confidence interval (CI); performance indicators, including recall rate, cancer detection rate (CDR), positive predictive value1 (PPV1), sensitivity, specificity, and interval cancer rate (ICR); and the types of breast cancer pathology. RESULTS: The AUCs were 0.898 (95% CI, 0.878-0.919) in DM, 0.860 (0.815-0.905) in FSM, and 0.866 (0.828-0.903) in CRM (p = 0.150). DM showed better performance than FSM and CRM in terms of the recall rate (14.8 vs. 24.8 and 19.8%), CDR (3.4 vs. 2.2 and 2.1 per 1000 examinations), PPV1 (2.3 vs. 0.9 and 1.1%), and specificity (85.5 vs. 75.3 and 80.3%) (p < 0.001) but not in terms of sensitivity (86.3 vs. 87.4 and 86.3%) and ICR (0.6 vs. 0.4 and 0.4). The proportions of carcinoma in situ (CIS) were 27.5%, 13.6%, and 11.8% for DM, CRM, and FSM, respectively (p = 0.003). CONCLUSION: In comparison to FSM and CRM, DM showed better performance in terms of the recall rate, CDR, PPV1, and specificity, although the AUCs were similar, and more CISs were detected using DM. The application of DM may help to improve the quality of mammography screenings. However, the overdiagnosis issue of CIS using DM should be evaluated.
Assuntos
Neoplasias da Mama/diagnóstico , Mamografia/instrumentação , Área Sob a Curva , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer , Feminino , Hospitais , Humanos , Mamografia/métodos , Curva ROC , República da Coreia , Estudos Retrospectivos , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: To suggest different ultrasound-guided steroid injection (USI) techniques based on anatomical variations of the first extensor compartment (FEC), and to evaluate the usefulness of it, in patients with de Quervain's disease. MATERIALS AND METHODS: Twenty-eight patients who underwent USI for de Quervain's disease were included. Anatomical variations were classified into complete sub-compartmentalization (n = 11), distal incomplete sub-compartmentalization (n = 5), and no sub-compartmentalization (n = 12) on ultrasound. Involved sub-compartments were recorded in patients with complete sub-compartmentalization. USIs were performed based on the anatomical variations: in both sub-compartments (n = 2) or only in the affected sub-compartment (n = 9) depending on the location of tenosynovitis involvement, in patients with complete sub-compartmentalization; in proximal FEC in patients with distal incomplete sub-compartmentalization (n = 5); in the common compartment in patients with no sub-compartmentalization (n = 12). Medical charts were retrospectively reviewed for evaluation of clinical outcome at follow-up visits. RESULTS: Twenty-three out of 28 patients were followed up with a mean period of 31.2 days after injection (6~87 days). Mean VAS was 7.96 before injection (range: 4 to 10), which was significantly reduced to 0.65 at rest and 1.57 during activity at follow-up visits (p < 0.05). Twenty-two out of 23 patients were satisfied with the results. The mean proportion of subjective pain reduction was 82.0% (median 95%). CONCLUSION: Ultrasound-guided steroid injections using different injection techniques based on the anatomical variations of the FEC have shown to be beneficial in the management of de Quervain's disease.
Assuntos
Doença de De Quervain/tratamento farmacológico , Injeções Intra-Articulares/métodos , Esteroides/administração & dosagem , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença de De Quervain/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor/tratamento farmacológico , Medição da Dor , Estudos Retrospectivos , Tenossinovite/diagnóstico por imagemRESUMO
OBJECTIVE: To analyze participant factors that affect the diagnostic performance of screening mammography. MATERIALS AND METHODS: We enrolled 128756 cases from 10 hospitals between 2005 and 2010. We analyzed recall rate, cancer detection rate (CDR) per 1000 examinations, positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), and interval cancer rate (ICR) per 1000 negative examinations according to participant factors including age, breast density, and number of visit to the same institution, and adjusted for confounding variables. RESULTS: Increasing age improved recall rates (27.4% in 40's, 17.5% in 50's, 11.1% in 60's, and 8.6% in 70's), CDR (2.7, 3.2, 2.0, and 2.4), PPV (1.0, 1.8, 1.8, and 2.8%), sensitivity (81.3, 88.8, 90.3, and 94.7%), specificity (72.7, 82.7, 89.0, and 91.7%), and FPR (27.3, 17.3, 11.0, and 8.4%) (p < 0.05). Higher breast density impaired recall rates (4.0% in P1, 9.0% in P2, 28.9% in P3, and 27.8% in P4), PPV (3.3, 2.3, 1.2, and 1.3%), specificity (96.1, 91.2, 71.4, and 72.5%), and FPR (3.9, 8.9, 28.6, and 27.6%) (p < 0.001). It also increased CDR (1.3, 2.1, 3.3, and 3.6) and ICR (0.2, 0.3, 0.6, and 1.6) (p < 0.05). Successive visits to the same institution improved recall rates (20.9% for one visit, 10.7% for two visits, 7.7% for more than three visits), PPV (1.6, 2.8, and 2.7%), specificity (79.4, 89.6, and 92.5%), and FPR (20.6, 10.4, and 7.5%) (p < 0.001). CONCLUSION: Young age and dense breasts negatively affected diagnostic performance in mammography screening, whereas successive visits to the same institution had a positive effect. Examinee education for successive visits to the same institution would improve the diagnostic performance.
Assuntos
Neoplasias da Mama/diagnóstico , Adulto , Idoso , Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Bases de Dados Factuais , Detecção Precoce de Câncer , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , República da Coreia , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. MATERIALS AND METHODS: This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. RESULTS: Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). CONCLUSION: Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears.
Assuntos
Imageamento por Ressonância Magnética , Lesões do Manguito Rotador/diagnóstico por imagem , Ombro/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Artroscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Lesões do Manguito Rotador/cirurgia , Sensibilidade e Especificidade , Articulação do Ombro/diagnóstico por imagemRESUMO
OBJECTIVE: To analyze the diagnostic accuracy and trend in screening mammography in Korea. MATERIALS AND METHODS: We retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening in Korea (ABCS-K) and the database of the National Cancer Screening Program. We calculated performance indicators, including the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false-positive rate (FPR), and interval cancer rate (ICR). Changes in the performance indicators were calculated as the annual percent change with 95% confidence interval (CI). RESULTS: We enrolled 128756 cases from 10 hospitals from 2005 to 2010. The recall rate was 19.1% with a downward trend over time (-12.1% per year; 95% CI, -15.9 to -8.2). The CDR was 2.69 per 1000 examinations, without a significant trend. The PPV was 1.4% with an upward trend (20.8% per year; 95% CI, 15.2 to 26.7). The sensitivity was 86.5% without a significant trend, whereas the specificity was 81.1% with an upward trend (3.3% per year; 95% CI, 2.1 to 4.5). The FPR was 18.9% with a downward trend (-12.4% per year; 95% CI, -16.2 to -8.4). The ICR was 0.5 per 1000 negative examinations without a significant trend. There were institutional variations in the diagnostic accuracy and trend except for the CDR, sensitivity, and ICR. CONCLUSION: The sensitivity and CDR of screening mammography in the ABCS-K from 2005 to 2010 were compatible with those for Western women. The recall rate, PPV and specificity, however, were suboptimal, although they showed significant improvements over this period. A further analysis is required to explain institutional variations.
Assuntos
Neoplasias da Mama/diagnóstico , Mamografia , Adulto , Idoso , Bases de Dados Factuais , Detecção Precoce de Câncer , Feminino , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , República da Coreia , Estudos Retrospectivos , Sensibilidade e EspecificidadeRESUMO
Many hospitals experience one or more retained surgical instrument events with risk of patient morbidity and medicolegal problems. Identification of retained surgical instrument is important. The radiologists should be familiar with imaging finding of retained surgical instrument. In a 62-year-old female with a retained plastic tube, localized peritoneal infiltration around air-containing tubular structure mimicked acute appendicitis on abdomen computed tomography (CT), one year after laparoscopic cholecystectomy. We reported CT findings of foreign body reaction related to retained Endoloop ligature plastic tube mimicking acute appendicitis.
Assuntos
Reação a Corpo Estranho/diagnóstico , Peritonite/diagnóstico , Plásticos/efeitos adversos , Tomografia Computadorizada por Raios X , Abdome/diagnóstico por imagem , Doença Aguda , Apendicite/diagnóstico , Apendicite/cirurgia , Erros de Diagnóstico , Feminino , Reação a Corpo Estranho/diagnóstico por imagem , Humanos , Laparoscopia , Pessoa de Meia-Idade , Peritonite/diagnóstico por imagem , Peritonite/etiologia , Plásticos/químicaRESUMO
Nerve compression syndromes commonly involve the nerves in the upper extremity. High-resolution ultrasonography (US) can satisfactorily assess these nerves and may detect the morphological changes of the nerves. US can also reveal the causes of nerve compression when structural abnormalities or space-occupying lesions are present. The most common US finding of compression neuropathy is nerve swelling proximal to the compression site. This article reviews the normal anatomic location and US appearances of the median, ulnar, and radial nerves. Common nerve compression syndromes in the upper extremity and their US findings are also reviewed.
RESUMO
OBJECTIVE: To evaluate magnetic resonance imaging (MRI) observer variability to detect ectopic insertion of the pectoralis minor tendon (EIPMT) and to investigate changes in the rotator interval in patients with EIPMT using MRI. MATERIALS AND METHODS: A total of 507 shoulder MRIs (male:female = 259:248; mean age, 55.4 years) were classified into 1) normal type insertion of the pectoralis minor tendon, 2) complete type EIPMT, and 3) partial type EIPMT independently by two radiologists. Inter-observer agreement was calculated using the kappa coefficient. Thickness of the fibrotic scar tissue in the subcoracoid triangle and humeral side axillary recess was measured. MRIs were reviewed by consensus with regard to the grade of fibrotic scar tissue proliferation in the rotator interval. Comparisons were made between normal and EIPMT and between partial and complete type EIPMT. RESULTS: The incidence of EIPMT was 13.4% (complete type, 7.7%; partial type, 5.7%). Inter-observer agreement was substantial (κ = 0.775). Fibrotic scar tissue in the subcoracoid triangle was thicker, and the grade of fibrotic scar tissue proliferation in the rotator interval was higher in the EIPMT group than those in the control group. No significant difference was observed in the thickness of humeral side axillary recess. The thicknesses of fibrotic scar tissue in the subcoracoid triangle and humeral side axillary recess as well as the grade of fibrotic scar tissue in the rotator interval were not significantly different between complete and partial type EIPMT. CONCLUSION: MRI enabled detection of EIPMT with substantial observer agreement. Patients with EIPMT show a high tendency for fibrotic scar tissue proliferation in the rotator interval.
Assuntos
Imageamento por Ressonância Magnética , Manguito Rotador/diagnóstico por imagem , Tendões/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Manguito Rotador/patologia , Ombro/diagnóstico por imagem , Ombro/patologia , Tendões/patologia , Adulto JovemRESUMO
OBJECTIVE: We observed patients in whom the fluid collection in the right lateral portion of the superior aortic recess on computed tomography (CT) scans mimicked a right anterior mediastinal mass on chest PA radiographs. The purpose of this study was to assess chest PA and CT features of these patients. MATERIALS AND METHODS: All chest PA radiographs and CT scans in 9 patients were reviewed by two radiologists on a consensus basis; for the presence of pleural effusion, pulmonary edema and heart size on chest PA radiographs. For the portion of the fluid collection in the superior aortic recess (SAR), a connection between the right lateral portion of the SAR (rSAR) and posterior portion of the SAR (pSAR) on CT scans, and the distance between the right lateral margin of the rSAR and the right lateral margin of the superior vena cava. RESULTS: Fluid collection in the rSAR on CT scans caused a right anterior mediastinal mass or a bulging contour on chest PA radiographs in all women patients. All patients showed cardiomegaly, five patients had pleural effusion, and two patients had mild pulmonary edema. Further, eight patients showed a connection between the rSAR and the pSAR. CONCLUSION: The characteristic features of these patients are the right anterior mediastinal mass-like opacity due to fluid collection in the rSAR, are bulging contour with a smooth margin and cardiomegaly regardless of pulmonary edema on the chest PA radiographs, and fluid connection between the rSAR and the pSAR on CT scans.