Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 276
Filtrar
1.
Res Pract Thromb Haemost ; 8(4): 102431, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38840664

RESUMO

Background: Various cardiovascular diseases cause acquired von Willebrand syndrome (AVWS), which is characterized by a decrease in high-molecular-weight (large) von Willebrand factor (VWF) multimers. Mitral regurgitation (MR) has been reported as a cause of AVWS. However, much remains unclear about AVWS associated with MR. Objectives: To evaluate VWF multimers in MR patients and examine their impact on clinical characteristics. Methods: Moderate or severe MR patients (n = 84) were enrolled. VWF parameters such as the VWF large multimer index (VWF-LMI), a quantitative value that represents the amount of VWF large multimers, and clinical data were prospectively analyzed. Results: At baseline, the mean hemoglobin level was 12.9 ± 1.9 g/dL and 58 patients (69.0%) showed loss of VWF large multimers defined as VWF-LMI < 80%. VWF-LMI in patients with degenerative MR was lower than in those with functional MR. VWF-LMI appeared to be restored the day after mitral valve intervention, and the improvement was maintained 1 month after the intervention. Seven patients (8.3%) had a history of bleeding, 6 (7.1%) of whom had gastrointestinal bleeding. Gastrointestinal endoscopy was performed in 23 patients (27.4%) to investigate overt gastrointestinal bleeding, anemia, etc. Angiodysplasia was detected in 2 of the 23 patients (8.7%). Conclusion: Moderate or severe MR is frequently associated with loss of VWF large multimers, and degenerative MR may cause more severe loss compared with functional MR. Mitral valve intervention corrects the loss of VWF large multimers. Gastrointestinal bleeding may be relatively less frequent and hemoglobin level remains stable in MR patients.

2.
Am Heart J ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38876408

RESUMO

BACKGROUND: The semiquantitative Clinical Frailty Scale (CFS) is reportedly a useful marker for predicting short- and mid-term mortality after transcatheter aortic valve implantation (TAVI). We assessed the long-term prognostic impact of CFS in patients with severe aortic stenosis undergoing TAVI. METHODS: We prospectively assessed patients undergoing TAVI in Kokura Memorial Hospital using a 9-level CFS and enrolled 1594 patients after excluding patients with CFS 8-9. The patients were divided into the low (CFS level, 1-3; N = 842), intermediate (4; N = 469), and high (5-7; N = 283) groups according to their CFS levels. RESULTS: In the low, intermediate, and high groups, 3-year all-cause mortality rates were 17.4%, 29.4%, and 41.7% (P <0.001) and composite rates of cardiovascular mortality and heart failure hospitalization were 12.1%, 19.1%, and 23.9% (P <0.001), respectively. Multivariable analysis showed that higher frailty was independently associated with all-cause mortality (intermediate group: adjusted hazard ratio [HR], 1.63, 95% confidence interval [CI], 1.24-2.15, P <0.001; high group: adjusted HR, 2.18, 95% CI, 1.59-2.99, P <0.001) and composite of cardiovascular mortality and heart failure hospitalization (intermediate group: adjusted HR, 1.47, 95% CI, 1.04-2.08, P = 0.030; high group: adjusted HR, 1.66, 95% CI, 1.09-2.51, P = 0.018) and this result was consistent, irrespective of stratification based on age, sex, body mass index, left ventricular ejection fraction, Society of Thoracic Surgeons score, and New York Heart Association functional class without significant interaction. CONCLUSIONS: The simple CFS tool predicts the long-term adverse outcomes post-TAVI.

3.
Am J Cardiol ; 223: 156-164, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38797196

RESUMO

The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Causas de Morte/tendências , Idoso , Pontuação de Propensão , Incidência , Valva Aórtica/cirurgia , Seguimentos , Insuficiência Cardíaca , Resultado do Tratamento , Fatores de Risco
4.
Circ J ; 88(7): 1187-1197, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38763735

RESUMO

BACKGROUND: Limited data are available regarding clinical outcomes after percutaneous left atrial appendage closure using WATCHMAN FLX (WM-FLX) and WATCHMAN-2.5 (WM2.5) devices in Asian patients.Methods and Results: Data of 1,464 consecutive patients (WM-FLX, n=909; WM2.5, n=555) were extracted from a Japanese multicenter registry, and clinical data were compared between the 2 groups. No in-hospital deaths, periprocedural stroke, or device embolization occurred. Procedural success was significantly higher in the WM-FLX than WM2.5 group (95.8% vs. 91.9%; P=0.002) owing to the lower incidence of periprocedural pericardial effusion (0.55% vs. 1.8%; P=0.021). No significant differences in all-cause death, postprocedural stroke, and device-related thrombus were observed between the 2 groups. However, the cumulative bleeding rate at 1 year was substantially lower in the WM-FLX group (7.8% vs. 16.4%; P<0.001). Landmark analysis of bleeding events highlighted lower bleeding rates in the WM-FLX than WM2.5 group within the first 6 months (6.4% vs. 14.8%; P<0.001), with comparable bleeding rates over the 6- to 12-month period (1.5% vs. 3.2%, respectively; P=0.065). CONCLUSIONS: This study demonstrated higher early safety and lower 1-year bleeding rates in the WM-FLX than WM2.5 group. The lower bleeding events with WM-FLX are likely due to multiple factors other than purely difference in devices, such as postprocedural drug regimen.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Sistema de Registros , Humanos , Idoso , Apêndice Atrial/cirurgia , Masculino , Feminino , Idoso de 80 Anos ou mais , Fibrilação Atrial/cirurgia , Japão , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Pessoa de Meia-Idade , Oclusão do Apêndice Atrial Esquerdo
5.
JACC Case Rep ; 29(9): 102302, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38708428

RESUMO

Transcatheter aortic valve replacement in extra-large annulus is challenging because of the limited sizes and data of the current commercial prosthesis sizes available. We present a case of successful transcatheter aortic valve replacement with a new balloon-expandable SAPIEN 3 Ultra RESILIA valve for an aortic annulus area >1,000 mm2 on computed tomography.

6.
Circ J ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38719572

RESUMO

BACKGROUND: Data on concomitant mitral regurgitation (MR) in patients with severe aortic stenosis (AS) are scarce.Methods and Results: We investigated the risk of concomitant MR in patients with severe AS in the CURRENT AS Registry-2 according to initial treatment strategy (transcatheter aortic valve implantation [TAVI], surgical aortic valve replacement [SAVR], or conservative). Among 3,365 patients with severe AS, 384 (11.4%) had moderate/severe MR (TAVI: n=126/1,148; SAVR: n=68/591; conservative: n=190/1,626). The cumulative 3-year incidence for death or heart failure (HF) hospitalization was significantly higher in the moderate/severe than no/mild MR group in the entire population (54.6% vs. 34.3%, respectively; P<0.001) and for each treatment strategy (TAVI: 45.0% vs. 31.8% [P=0.006]; SAVR: 31.9% vs. 18.7% [P<0.001]; conservative: 67.8% vs. 41.6% [P<0.001]). The higher adjusted risk of moderate/severe MR relative to no/mild MR for death or HF hospitalization was not significant in the entire population (hazard ratio [HR] 1.15; 95% confidence interval [CI] 0.95-1.39; P=0.15); however, the risk was significant in the SAVR (HR 1.92; 95% CI 1.04-3.56; P=0.04) and conservative (HR 1.30; 95% CI 1.02-1.67; P=0.04) groups, but not in the TAVI group (HR 1.03; 95% CI 0.70-1.52; P=0.86), despite no significant interaction (Pinteraction=0.37). CONCLUSIONS: Moderate/severe MR was associated with a higher risk for death or HF hospitalization in the initial SAVR and conservative strategies, while the association was less pronounced in the initial TAVI strategy.

7.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726714

RESUMO

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Feminino , Masculino , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Desenho de Prótese , Hemodinâmica , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Mortalidade Hospitalar
8.
J Cardiol ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38754762

RESUMO

BACKGROUND: There is a scarcity of data on the prevalence of abnormal findings on preprocedural computed tomography (CT) before aortic valve replacement (AVR) in patients with aortic stenosis (AS). METHODS: Among consecutive 593 patients with severe AS who were planned to undergo AVR, we evaluated the prevalence of clinically significant incidental noncardiac findings on preprocedural CT. Clinically significant incidental noncardiac findings were defined as newly detected abnormalities that required therapy, consultation for expert, further investigation, or clinical follow-up. RESULTS: The mean age was 82.0 years and 39.5 % of the patients were men. Of those, 78.4 % of the patients were treated with transcatheter aortic valve implantation (TAVI) and 21.6 % of the patients were treated with surgical AVR (SAVR). There were 271 clinically significant incidental noncardiac findings in 227 patients (38.3 %) including 2.5 % of malignancy. The prevalence of clinically significant incidental noncardiac findings were higher in the TAVI group than in the SAVR group (40.2 % versus 31.3 %). The prevalence of clinically significant incidental noncardiac findings were lower in patients under 60 years of age (10.0 %) than in patients over 60 years of age (60-69 years: 40.0 %, 70-79 years: 34.3 %, 80-89 years: 39.7 %, and ≥90 years: 42.1 %). CONCLUSIONS: Clinically significant incidental noncardiac findings were newly identified on preprocedural CT in approximately 40 % of patients with severe AS undergoing AVR including 2.5 % of malignancy.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38816190

RESUMO

BACKGROUND: Although pure GAA expansion is considered pathogenic in SCA27B, non-GAA repeat motif is mostly mixed into longer repeat sequences. This study aimed to unravel the complete sequencing of FGF14 repeat expansion to elucidate its repeat motifs and pathogenicity. METHODS: We screened FGF14 repeat expansion in a Japanese cohort of 460 molecularly undiagnosed adult-onset cerebellar ataxia patients and 1022 controls, together with 92 non-Japanese controls, and performed nanopore sequencing of FGF14 repeat expansion. RESULTS: In the Japanese population, the GCA motif was predominantly observed as the non-GAA motif, whereas the GGA motif was frequently detected in non-Japanese controls. The 5'-common flanking variant was observed in all Japanese GAA repeat alleles within normal length, demonstrating its meiotic stability against repeat expansion. In both patients and controls, pure GAA repeat was up to 400 units in length, whereas non-pathogenic GAA-GCA repeat was larger, up to 900 units, but they evolved from different haplotypes, as rs534066520, located just upstream of the repeat sequence, completely discriminated them. Both (GAA)≥250 and (GAA)≥200 were enriched in patients, whereas (GAA-GCA)≥200 was similarly observed in patients and controls, suggesting the pathogenic threshold of (GAA)≥200 for cerebellar ataxia. We identified 14 patients with SCA27B (3.0%), but their single-nucleotide polymorphism genotype indicated different founder alleles between Japanese and Caucasians. The low prevalence of SCA27B in Japanese may be due to the lower allele frequency of (GAA)≥250 in the Japanese population than in Caucasians (0.15% vs 0.32%-1.26%). CONCLUSIONS: FGF14 repeat expansion has unique features of pathogenicity and allelic origin, as revealed by a single ethnic study.

10.
JACC Asia ; 4(4): 306-319, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38660100

RESUMO

Background: Few reports on pre-existing left bundle branch block (LBBB) in patients undergoing transcatheter aortic valve replacement (TAVR) are currently available. Further, no present studies compare patients with new onset LBBB with those with pre-existing LBBB. Objectives: This study aimed to investigate the association between pre-existing or new onset LBBB and clinical outcomes after TAVR. Methods: Using data from the Japanese multicenter registry, 5,996 patients who underwent TAVR between October 2013 and December 2019 were included. Patients were classified into 3 groups: no LBBB, pre-existing LBBB, and new onset LBBB. The 2-year clinical outcomes were compared between 3 groups using Cox proportional hazards models and propensity score analysis to adjust the differences in baseline characteristics. Results: Of 5,996 patients who underwent TAVR, 280 (4.6%) had pre-existing LBBB, while 1,658 (27.6%) experienced new onset LBBB. Compared with the no LBBB group, multivariable Cox regression analysis showed that pre-existing LBBB was associated not only with a higher 2-year all-cause (adjusted HR: 1.39; 95% CI: 1.06-1.82; P = 0.015) and cardiovascular (adjusted HR: 1.60; 95% CI: 1.04-2.48; P = 0.031) mortality, but also with higher all-cause (adjusted HR: 1.43, 95% CI: 1.07-1.91; P = 0.016) and cardiovascular (adjusted HR: 1.81, 95% CI:1.12-2.93; P = 0.014) mortality than the new onset LBBB group. Heart failure was the most common cause of cardiovascular death, with more heart failure deaths in the pre-existing LBBB group. Conclusions: Pre-existing LBBB was independently associated with poor clinical outcomes, reflecting an increased risk of cardiovascular mortality after TAVR. Patients with pre-existing LBBB should be carefully monitored.

11.
JACC Case Rep ; 29(10): 102335, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38623541

RESUMO

Patent foramen ovale (PFO) complicated with carcinoid heart disease (CHD) can cause severe hypoxia and worsening clinical conditions. We report the case of a patient with CHD in poor general condition with multiple severe valve regurgitations and PFO, who underwent successful percutaneous closure of the PFO.

12.
Commun Biol ; 7(1): 413, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594382

RESUMO

Better understanding of the earliest molecular pathologies of all neurodegenerative diseases is expected to improve human therapeutics. We investigated the earliest molecular pathology of spinocerebellar ataxia type 1 (SCA1), a rare familial neurodegenerative disease that primarily induces death and dysfunction of cerebellum Purkinje cells. Extensive prior studies have identified involvement of transcription or RNA-splicing factors in the molecular pathology of SCA1. However, the regulatory network of SCA1 pathology, especially central regulators of the earliest developmental stages and inflammatory events, remains incompletely understood. Here, we elucidated the earliest developmental pathology of SCA1 using originally developed dynamic molecular network analyses of sequentially acquired RNA-seq data during differentiation of SCA1 patient-derived induced pluripotent stem cells (iPSCs) to Purkinje cells. Dynamic molecular network analysis implicated histone genes and cytokine-relevant immune response genes at the earliest stages of development, and revealed relevance of ISG15 to the following degradation and accumulation of mutant ataxin-1 in Purkinje cells of SCA1 model mice and human patients.


Assuntos
Células-Tronco Pluripotentes Induzidas , Ataxias Espinocerebelares , Animais , Humanos , Camundongos , Citocinas , Células-Tronco Pluripotentes Induzidas/patologia , Camundongos Transgênicos , Células de Purkinje/fisiologia , Ataxias Espinocerebelares/genética , Ataxias Espinocerebelares/patologia , Ubiquitinas
13.
Circ Cardiovasc Interv ; 17(6): e013794, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38629311

RESUMO

BACKGROUND: The extent of cardiac damage and its association with clinical outcomes in patients undergoing transcatheter edge-to-edge repair (TEER) for degenerative mitral regurgitation remains unclear. This study was aimed to investigate cardiac damage in patients with degenerative mitral regurgitation treated with TEER and its association with outcomes. METHODS: We analyzed patients with degenerative mitral regurgitation treated with TEER in the Optimized Catheter Valvular Intervention-Mitral registry, which is a prospective, multicenter observational data collection in Japan. The study subjects were classified according to the extent of cardiac damage at baseline: no extravalvular cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate left ventricular or left atrial damage (stage 2), or right heart damage (stage 3). Two-year mortality after TEER was compared using Kaplan-Meier analysis. RESULTS: Out of 579 study participants, 8 (1.4%) were classified as stage 0, 76 (13.1%) as stage 1, 319 (55.1%) as stage 2, and 176 (30.4%) as stage 3. Two-year survival was 100% in stage 0, 89.5% in stage 1, 78.9% in stage 2, and 75.3% in stage 3 (P=0.013). Compared with stage 0 to 1, stage 2 (hazard ratio, 3.34 [95% CI, 1.03-10.81]; P=0.044) and stage 3 (hazard ratio, 4.51 [95% CI, 1.37-14.85]; P=0.013) were associated with increased risk of 2-year mortality after TEER. Significant reductions in heart failure rehospitalization rate and New York Heart Association functional scale were observed following TEER (both, P<0.001), irrespective of the stage of cardiac damage. CONCLUSIONS: Advanced cardiac damage is associated with an increased risk of mortality in patients undergoing TEER for degenerative mitral regurgitation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: UMIN000023653.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Sistema de Registros , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Masculino , Feminino , Idoso , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Japão , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Resultado do Tratamento , Fatores de Tempo , Estudos Prospectivos , Fatores de Risco , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/instrumentação , Medição de Risco , Recuperação de Função Fisiológica , Traumatismos Cardíacos/mortalidade , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/terapia , Traumatismos Cardíacos/diagnóstico por imagem
14.
ESC Heart Fail ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607328

RESUMO

AIMS: A considerable proportion of candidates for transcatheter aortic valve implantation (TAVI) have underlying heart failure (HF) with preserved ejection fraction (HFpEF), which can be challenging for diagnosis because significant valvular heart disease should be excluded before diagnosing HFpEF. This study investigated the long-term prognostic value of the pre-procedural H2FPEF score in patients with preserved ejection fraction (EF) undergoing TAVI. METHODS AND RESULTS: Patients who underwent TAVI between October 2013 and May 2017 were enrolled from the Optimized CathEter vAlvular iNtervention-Transcatheter Aortic Valve Implantation Japanese multicentre registry. After excluding 914 patients, 1674 patients with preserved EF ≥ 50% (median age: 85 years, 72% female) were selected for calculation of the H2FPEF score and were dichotomized into two groups: the low H2FPEF score [0-5 points; n = 1399 (83.6%)] group and the high H2FPEF score [6-9 points; n = 275 (16.4%)] group. Patients with high H2FPEF scores were associated with a higher prevalence of New York Heart Association Functional Class III/IV (59.3% vs. 43.7%, P < 0.001), diabetes (24.4% vs. 18.5%, P = 0.03), and paradoxical low-flow, low-gradient aortic stenosis (15.9% vs. 6.2%, P < 0.001). These patients showed worse prognoses than those with low H2FPEF scores regarding the cumulative 2 year all-cause mortality (26.3% vs. 15.5%, log-rank P < 0.001), cardiovascular mortality (10.5% vs. 5.4%, log-rank P < 0.001), HF hospitalization (16.2% vs. 6.7%, log-rank P < 0.001), and the composite endpoint of cardiovascular mortality and HF hospitalization (23.8% vs. 10.8%, log-rank P < 0.001). After adjustment for several confounders, the high H2FPEF scores were independently associated with increased risk for all-cause mortality [adjusted hazard ratio (HR), 1.48; 95% confidence interval (CI), 1.09-2.00; P = 0.011] and for the composite endpoint of cardiovascular mortality and HF hospitalization (adjusted HR, 1.95; 95% CI, 1.38-2.74; P < 0.001). Subgroup analysis confirmed the excess risk of high H2FPEF scores relative to low H2FPEF scores for the composite endpoint of cardiovascular mortality and HF hospitalization increased with a lower Society of Thoracic Surgeons (STS) score (STS score <8%: adjusted HR, 2.40; 95% CI, 1.50-3.85; P < 0.001; STS score ≥8%: adjusted HR, 1.34; 95% CI, 0.79-2.28; P = 0.28; Pinteraction = 0.030). CONCLUSIONS: The H2FPEF score is useful for predicting long-term adverse outcomes after TAVI, including all-cause mortality, cardiovascular mortality, and HF hospitalization for patients with preserved EF. More aggressive interventions targeting HFpEF in addition to the TAVI procedure might be relevant in patients with high H2FPEF scores, particularly in those with a lower surgical risk.

18.
Open Heart ; 11(1)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38417913

RESUMO

OBJECTIVES: The clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS) and concomitant active cancer remain insufficiently explored. This study aimed to assess the midterm outcomes of TAVR in patients diagnosed with AS and active cancer. METHODS: Data from the OCEAN-TAVI, a prospective Japanese registry of TAVR procedures, was analysed to compare prognoses and clinical outcomes in patients with and without active cancer at the time of TAVR. RESULTS: Of the 2336 patients who underwent TAVR from October 2013 to July 2017, 89 patients (3.8%) had active cancer, whereas 2247 did not. Among patients with active cancer, 49 had limited-stage cancer (stage 1 or 2). The prevalent cancers identified before TAVR were colon (21%), prostate (18%), lung (15%), liver (11%) and breast (9%). Although the periprocedural complications and 30-day mortality rates were comparable between the groups, the 3-year survival rate after TAVR was notably lower in patients with active cancer (64.7%) than in those without active cancer (74.7%; p=0.016). Nevertheless, the 3-year survival rate of patients with limited-stage cancer (stage 1 or 2) did not significantly differ from those without cancer (70.6% vs 74.7%, p=0.50). CONCLUSIONS: The patients with active cancer exhibited significantly reduced midterm survival rates. However, no distinct disparity existed in those with limited-stage cancer (stage 1 or 2). Although TAVR is a viable treatment in patients with AS with active cancer, the type and stage of cancer and prognosis should be carefully weighed in the decision-making process.


Assuntos
Estenose da Valva Aórtica , Neoplasias , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estudos Prospectivos , Fatores de Tempo , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Neoplasias/diagnóstico
19.
Clin Neurol Neurosurg ; 237: 108147, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38325040

RESUMO

OBJECTIVE: The unified multiple system atrophy rating scale (UMSARS) was used to evaluate various symptoms of multiple system atrophy (MSA). And UMSARS part 1 was originally developed for use in interviews, but the need for telemedicine is increasing in COVID-19 pandemic. The purpose of this study is to evaluate the reliability of the UMSARS part 1 telephone survey. METHODS: Thirty-two MSA patients took the UMSARS part 1 face-to-face, followed by two more telephone evaluations. Intraclass correlation coefficients (ICC) and Cronbach's alpha (α) coefficients were calculated, and the inter-rater reliability was determined. At the same time, we asked about the problems in COVID-19 pandemic. RESULTS: The study participants included 15 men and 17 women with mean age of 67.1 years (SD, 8.3). For the total UMSARS part 1 score, the inter-rater ICC and Cronbach's α coefficient were 0.89 to 0.92, and 0.84 to 0.87, respectively. More than half of the items had a relatively high ICC. Cronbach's α coefficients were more than 0.7 for all items. Changes that occurred in COVID-19 pandemic included reduced outings and lack of rehabilitation in about half of the cases. CONCLUSION: The UMSARS part 1 has high inter-rater reliability and internal consistency. Evaluation of subjective symptoms showed that some variability could occur. In addition, there was concern about the influence of lack of rehabilitation due to COVID-19 pandemic.


Assuntos
COVID-19 , Atrofia de Múltiplos Sistemas , Masculino , Humanos , Feminino , Idoso , Atrofia de Múltiplos Sistemas/diagnóstico , Atrofia de Múltiplos Sistemas/epidemiologia , Reprodutibilidade dos Testes , Pandemias , Índice de Gravidade de Doença
20.
J Clin Med ; 13(3)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38337545

RESUMO

Background: Transcatheter edge-to-edge mitral valve repair (TEER) has emerged as a viable approach to addressing substantial secondary mitral regurgitation. In the contemporary landscape where ultimate heart failure-specific therapies, such as cardiac replacement modalities, are available, prognosticating a high-risk cohort susceptible to early cardiac mortality post-TEER is pivotal for formulating an effective therapeutic regimen. Methods: Our study encompassed individuals with secondary mitral regurgitation and chronic heart failure enlisted in the multi-center (Optimized CathEter vAlvular iNtervention (OCEAN)-Mitral registry. We conducted an assessment of baseline variables associated with cardiac death within one year following TEER. Results: Amongst the 1517 patients (median age: 78 years, 899 males), 101 experienced cardiac mortality during the 1-year observation period after undergoing TEER. Notably, a history of heart failure-related admissions within the preceding year, utilization of intravenous inotropes, and elevated plasma B-type natriuretic peptide levels emerged as independent prognosticators for the primary outcome (p < 0.05 for all). Subsequently, we devised a novel risk-scoring system encompassing these variables, which significantly stratified the cumulative incidence of the 1-year primary outcome (16%, 8%, and 4%, p < 0.001). Conclusions: Our study culminated in the development of a new risk-scoring system aimed at predicting 1-year cardiac mortality post-TEER.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...