Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Orthop Clin North Am ; 30(4): 599-613, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10471765

RESUMO

Coralline porous ceramics are biocompatible and osteoconductive implants. They have proven to be effective as bone graft substitutes in large animal models and in humans. Bone and supporting soft tissue grow into and throughout their porosity if the implant is placed in direct apposition to viable bone and the interfaces are stabilized. The bone within the implant remodels in response to Wolff's law. Both the implant properties (chemistry and porosity) and the biologic environment modulate the rate of implant resorption. Composite technology with resorbable polymers can improve the mechanical properties of these ceramics.


Assuntos
Materiais Biocompatíveis , Substitutos Ósseos , Cnidários , Implantes Absorvíveis , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/uso terapêutico , Fenômenos Biomecânicos , Remodelação Óssea/fisiologia , Substitutos Ósseos/química , Substitutos Ósseos/uso terapêutico , Transplante Ósseo , Cerâmica/química , Tecido Conjuntivo/fisiologia , Modelos Animais de Doenças , Humanos , Osteogênese/fisiologia , Polímeros/química , Porosidade
2.
Invest Radiol ; 31(11): 716-23, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8915753

RESUMO

RATIONALE AND OBJECTIVES: The authors evaluate whether dual-energy x-ray absorptiometry (DXA) is a reliable method to determine the density of natural coralline hydroxyapatite (HA) blocks used as bone graft substitutes. METHODS: To evaluate the basic density of HA blocks from the same coral heads with and without titanium meshes, densitometry of 12 HA-500 blocks (genus Goniopora) and 12 HA-200 blocks (genus Porites) was performed. In addition, density measurements of 30 HA blocks (HA-500, n = 15; HA-200, n = 15) from different coral heads were obtained to assess if the originating coral head influences the basic density of blocks within one coral genera. To assess standard deviation serial measurements on eight coralline HA blocks, four with titanium meshes and four without were performed. In the ex vivo study, densitometry of 12 HA blocks (HA-500, n = 4; HA-200, n = 8) used as bone graft substitutes in the mandibles and craniums of adult mongrel dogs was performed. Densities were measured after bone ingrowth for 2 and 4 months, respectively. All measurements were obtained with a Lunar DPX with scan mode "slow 750" in the spine program with the regions-of-interests selected manually. Bone ingrowth was assessed by computer-assisted histomorphometry, which was considered the gold standard. Statistical analysis was performed to correlate the densities of plain HA blocks with and without meshes to the specific weights of the blocks. RESULTS: Significant positive correlation was found between the density of each HA block (both coral species) with and without meshes and the calculated specific weights. Densitometry values showed no significant differences depending on the originating coral heads. Standard deviation ranged between +/- 3.8% and +/- 4.1% (HA-500) and between +/- 3.0% and +/- 3.8% (HA-200). Hydroxyapatite-500 blocks showed marked increased densities between 15% and 34% after 4 months in three specimens in which bone ingrowth between 16.9% and 21.1% was revealed by histomorphometry; no increase of density was observed in one specimen, which presented only minimal bone ingrowth and signs of infection. Despite bone invasion between 12% and 25.8%, no increased densities were observed for HA-200 implants. CONCLUSIONS: Dual-energy x-ray absorptiometry is an accurate and reproducible modality to assess the densities of plain coralline HA blocks and to monitor bone ingrowth into coralline HA-500 but not into HA-200 block implants.


Assuntos
Absorciometria de Fóton , Densidade Óssea , Durapatita , Próteses e Implantes , Animais , Cães , Titânio
3.
J Oral Maxillofac Surg ; 53(8): 915-22; discussion 922-3, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7629620

RESUMO

PURPOSE: This study was undertaken to determine the resorption rate of porous ceramic implants. The hypothesis was that implants placed in soft tissues would degrade more rapidly than implants placed in bone. MATERIALS AND METHODS: To test this hypothesis, implants were manufactured by applying a thin coating of hydroxylapatite onto an interconnected, porous calcium carbonate substrate. Control implants were made entirely of hydroxylapatite with identical microstructure. Two adult dogs received a total of 56 implants placed in the femur, skeletal muscle, and subcutaneous tissues. After killing the animals at 4 months, the specimens were removed, embedded in plastic, sectioned, and either stained for light microscopic examination or subjected to quantitative image analysis using a scanning electron microscope. RESULTS: Contrary to the hypothesis, the rate of degradation was faster for implants placed in bone than in soft tissue. Within the 4 months, degradation was 24% to 63% in bone, depending on the composition. However, it was not statistically significant in either intramuscular or subcutaneous tissue. A surprising observation was that bone ingrowth occurred in 67% of the implants placed in soft tissues. On average, it was 4.3% in intramuscular sites and 6.6% in subcutaneous sites. This bone was histologically normal in 71% of the implants containing bone. CONCLUSION: This study demonstrates that porous ceramic implants composed of hydroxylapatite on calcium carbonate will degrade more rapidly in bone defects than in soft tissue sites. In addition, implants with interconnected porosity and surfaces of hydroxylapatite will become ingrown with bone even after placement in soft tissues. The exact mechanisms for both of these phenomena are not understood.


Assuntos
Regeneração Óssea , Carbonato de Cálcio/farmacocinética , Cerâmica/farmacocinética , Durapatita/farmacocinética , Próteses e Implantes , Análise de Variância , Animais , Biodegradação Ambiental , Osso e Ossos/metabolismo , Cnidários , Tecido Conjuntivo/metabolismo , Cães , Músculo Esquelético/metabolismo , Porosidade
4.
J Biomater Appl ; 9(3): 275-88, 1995 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9309501

RESUMO

Coralline hydroxyapatite (cHA) is an osteoconductive material currently being used as a bone graft substitute. Created by the hydrothermal conversion of the calcium carbonate skeleton of coral to hydroxyapatite, this material has a porous structure similar to cancellous bone. Addition of demineralized bone matrix (DBM) would conceivably create a composite with both osteoconductive and osteoinductive properties. This pilot study evaluated the healing of rabbit cranial defects that had been filled with cHA or cHA augmented with a DBM gel formed by adding glycerol to the DBM particulate. Data from these were then compared to unfilled defects from a previous study. Results indicated enhancement of new bone formation and an increase in the rate of healing in the defects filled with the cHA-DBM gel composite. Further studies are warranted.


Assuntos
Técnica de Desmineralização Óssea , Matriz Óssea/ultraestrutura , Substitutos Ósseos , Cerâmica , Durapatita , Teste de Materiais , Osseointegração , Próteses e Implantes , Animais , Microscopia Eletrônica , Coelhos , Distribuição Aleatória , Crânio/cirurgia , Propriedades de Superfície
5.
Clin Mater ; 17(2): 85-91, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-10150211

RESUMO

The purpose of this study was to determine the potential of coralline calcium phosphate ceramics to support osteoblast growth for a proposed bone-ceramic composite for skeletal tissue repair. The goal was the development of a matrix with both osteogenic and osteoconductive properties, as compared to ceramic alone, which is solely osteoconductive. MC3T3-E1 osteoblast-like cells were seeded onto sintered and non-sintered porous coralline hydroxyapatite (HA), and onto non-porous hydroxyapatite discs. These in-vitro studies demonstrated that coralline HA supported the growth of osteoblast-like cells. Porous discs supported higher numbers of cells than non-porous discs. Sintering encouraged cell growth, with higher numbers of cells adhered to sintered porous HA discs by day seven. The results suggest that HA can provide a support for osteoblast cells as part of a matrix which may prove to be osteogenic in vivo and may, accordingly, enhance the bone repair process.


Assuntos
Materiais Biocompatíveis , Durapatita , Osseointegração/fisiologia , Osteoblastos/fisiologia , Divisão Celular , Linhagem Celular , Cerâmica , Humanos , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Osteoblastos/citologia , Porosidade
6.
Biomaterials ; 14(5): 341-8, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8389612

RESUMO

A previous study of coralline hydroxyapatite as a bone-graft substitute was extended from 4 to 12 months to determine better the relationships between implantation time, bone ingrowth and mechanical properties. The model consisted of a 10 x 30 mm window defect in the shaft of the canine radius (a cortical site), and a 10 mm diameter cylindrical defect in the head of the humerus (a cancellous site). In the new study, these two defects were made bilaterally in eight dogs, and filled with block-form coralline hydroxyapatite. The radius defects were supported by a metal fixation plate which was removed after 9 months. After 12 months, the dogs were killed and the left-side implants were analyzed histomorphometrically and mechanically. The right-side radius and humerus were reserved for structural analysis. The results were combined with those previously measured after 4, 8, 12 and 16 wk of implantation. In the cortical site, bone ingrowth increased from 52% at 16 wk to 74% at 1 yr. In the cancellous site, bone ingrowth was 38% after 4 wk, then fell monotonically, reaching 17% at 1 yr. Bending and compressive strength and stiffness of the radius implants increased throughout the post-implantation year, but compressive strength and stiffness of the humerus implants did not change after the first 2-4 months. Mechanical properties were strongly correlated to bone ingrowth in the cortical, but not the cancellous, site. The volume fraction of the coralline hydroxyapatite material diminished significantly with time in the cortical, but not the cancellous, site.


Assuntos
Osso e Ossos/fisiologia , Hidroxiapatitas , Osseointegração , Próteses e Implantes , Animais , Fenômenos Biomecânicos , Cães , Durapatita , Humanos , Úmero , Rádio (Anatomia)
7.
J Biomed Mater Res ; 26(7): 885-95, 1992 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-1607371

RESUMO

This study determined the bone formation in porous calcium carbonate (CC) and porous hydroxyapatite (HA) in ectopic sites. The bone formation stimulus was derived from bone marrow cells. CC and HA in the shape of disks were implanted with or without rat marrow cells into subcutaneous sites of syngeneic rats. The CC and HA had identical microstructure: pore size was 190-230 microns, porosity was 50-60% and they were fully interconnected. Bone did not form in any implants without marrow cells (disks themselves), whereas bone consistently formed in the pores of all implants with marrow cells after 4 weeks. The bone formation of both CC and HA occurred initially on surface of the pore regions and progressed toward the center of the pore. Scanning electron microscopy and electron-probe microanalysis revealed a continuum of calcium at the interfaces of both bone/CC and bone/HA implants. These results indicate that the bone formation in calcium carbonate derived from marine corals is comparable to the bioactive hydroxyapatite.


Assuntos
Células da Medula Óssea , Carbonato de Cálcio , Hidroxiapatitas , Osseointegração/fisiologia , Próteses e Implantes , Animais , Microscopia Eletrônica de Varredura , Ratos , Ratos Endogâmicos F344
8.
J Biomed Mater Res ; 24(12): 1563-70, 1990 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-2277053

RESUMO

To investigate the bone formation ability of porous hydroxyapatite (HA) and tricalcium phosphate (TCP), ceramic discs were implanted with or without rat marrow cells into subcutaneous sites in syngeneic rats. The discs of HA and TCP had identical microstructures: pore size was 190-230 microns, porosity was 50-60%, and they were fully interconnected. Implants without marrow cells (discs themselves) did not show bone formation, whereas implants with marrow cells showed bone formation in the pores of the ceramics. The bone formation of both HA and TCP occurred initially on the surface of the ceramic and progressed towards the center of the pore. The de novo bone was quantitated from decalcified serial sections of the implants. One month after implantation with marrow cells, the percentage fractions of the pore area filled with bone for implanted HA and TCP were 16.9 and 15.1, respectively. At 2 months after implantation with marrow cells, the fractions of bone were 34.3 and 30.9, respectively. These results indicate that both HA and TCP ceramics can show comparable osteogenic ability in the presence of marrow cells.


Assuntos
Materiais Biocompatíveis , Medula Óssea/fisiologia , Fosfatos de Cálcio , Hidroxiapatitas , Osseointegração/fisiologia , Animais , Células da Medula Óssea , Processamento de Imagem Assistida por Computador , Masculino , Microscopia de Fluorescência , Porosidade , Ratos , Ratos Endogâmicos F344
9.
Biomaterials ; 10(7): 481-8, 1989 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2804236

RESUMO

The dependence of strength on the amount of bone growth into a hydroxyapatite material made from coral was investigated. Block and granular forms of the material were implanted into cortical and trabecular regions of the skeletons of 16 dogs. The results were examined after 4, 8, 12 and 16 wk, with four dogs in each experimental group. When implanted into cortical bone, the bending strength of the implant material was found to be highly correlated with the amount of pore space which had become occupied by bone (r = 0.92, P less than 0.005 for the block form; r = 0.84, P less than 0.005 for the granular form). Multiple regression analysis showed that six histomorphometric measures of ingrowth accounted for 96% of the variability in bending strength of the block material, and there were no significant differences between block and granular forms of the material. On the other hand, when implanted into trabecular bone, the block form of the material achieved greater compressive strength than the granular form. While both strength and ingrowth increased with time, there were poor correlations between these two variables. Finally, when the material is implanted into trabecular bone, it becomes stronger in compression than the surrounding bone; when implanted in cortical bone, linear modelling suggests that resorption and replacement of the implant would be required to approximate the bending strength of the surrounding bone.


Assuntos
Materiais Biocompatíveis , Osso e Ossos/fisiologia , Hidroxiapatitas , Teste de Materiais , Animais , Densidade Óssea , Cães , Elasticidade , Fraturas do Rádio/cirurgia , Estresse Mecânico
10.
Artigo em Inglês | MEDLINE | ID: mdl-2775867

RESUMO

This study evaluated the long-term patency and durability of 6 mm internal diameter (ID), 18-30 micron pore size replamineform silicone rubber vascular prostheses as canine aortic interposition and arteriovenous (A-V) grafts. Six prostheses (6 mm ID x 8 cm length) were evaluated as aortic grafts for 24 to 30 months, and 10 prostheses (6 mm ID x 8-10 cm length) were studied as A-V grafts from 2 weeks to 10 months. Three of the A-V prostheses were punctured for sham dialysis once or twice/week with two 16 gauge needles (total of approximately 50 needle punctures). The porous wall of the silicone rubber prostheses was incorporated with capillaries and fibrohistiocytic cellular elements from 2 weeks of implantation. This cellular incorporation remained constant up to 2 1/2 years. Needle puncture of the arteriovenous grafts over a 3 to 5 month period produced no complications such as thrombosis, perigraft hematoma formation or bleeding through the puncture site. The silicone rubber sealed the holes with no evidence of tearing. Explanted prostheses had no evidence of enlargement or false aneurysm formation. This study supports our hypothesis that Replamineform silicone rubber prostheses are hemocompatable and demonstrate long-term durability for dialysis access. Clinical evaluation of this graft is planned in the near future.


Assuntos
Materiais Biocompatíveis , Prótese Vascular , Elastômeros de Silicone , Animais , Aorta/cirurgia , Derivação Arteriovenosa Cirúrgica , Cães , Estudos de Avaliação como Assunto
11.
J Cardiovasc Surg (Torino) ; 28(5): 485-90, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3654733

RESUMO

Compliance is believed to be a significant factor in maintaining the patency of small diameter vascular grafts. This study evaluated the compliance changes with time of microporous Replamineform silicone rubber prostheses. The compliance of 15 canine femoral artery interpositions (4 mm internal diameter X 6 cm length) was measured by in-vivo electromagnetic rheoangiometry immediately following implantation and at intervals to eight months. At implantation, silicone rubber grafts were overcompliant (15.0 +/- 1.1% radial change/mmHg X 10(-2); mean +/- S.E.) compared to the proximal artery (7.7 +/- .6%). The compliance of the prostheses decreased within two weeks (6.3 +/- .9%) and remained isocompliant to the proximal artery for eight months. The compliance determinations for the silicone rubber grafts were compared with those from PTFE prostheses and vein grafts acquired by the same method in a previous study. The analysis demonstrates the preservation of isocompliance of the silicone rubber prostheses compared to the native arteries. In contrast, the minimally compliant vein grafts and PTFE prostheses continued to decrease in compliance following implantation. This microporous silicone rubber graft may improve the success of small internal diameter arterial reconstructions by eliminating failures caused by compliance mismatch between the artery and the prosthesis.


Assuntos
Prótese Vascular , Elastômeros de Silicone , Animais , Complacência (Medida de Distensibilidade) , Cães , Estudos de Avaliação como Assunto , Oclusão de Enxerto Vascular/epidemiologia , Desenho de Prótese , Fatores de Tempo
12.
J Appl Physiol (1985) ; 61(2): 575-83, 1986 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-3745048

RESUMO

We determined the role of blood flow-induced changes in CO2 load to the lungs on ventilatory control, at rest and in the steady-state of electrically induced exercise, in the anesthetized dog. A portion of the vena caval blood was diverted to the descending aorta following "arterialization" through an extracorporeal gas exchanger. Ventilation typically decreased, both at rest and during exercise (i.e., at 2 different levels of mixed venous CO2), in proportion to the CO2 loss; arterial PCO2 was consequently regulated. There were concomitant increases of the pulmonary and peripheral vascular resistance. Bilateral cervical vagosympathectomy markedly attenuated the ventilatory response at rest, thus disrupting arterial PCO2 homeostasis, but not so during exercise. The results therefore provide evidence for and support the suggestion of CO2 flow-related hyperpnea both at rest and during muscular exercise.


Assuntos
Ponte Cardiopulmonar , Esforço Físico , Respiração , Descanso , Animais , Pressão Sanguínea , Débito Cardíaco , Cães , Feminino , Ventrículos do Coração , Masculino , Sistema Vasomotor/fisiologia , Veias/fisiologia
13.
ASAIO Trans ; 32(1): 601-4, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3778780

RESUMO

This study demonstrates that 20 to 30 microns porous, Replamineform silicone rubber prostheses remain isocompliant with adjacent arterial segments up to 8 months following implantation. This finding contrasts with the results of currently available prostheses, including autologous vein, which rapidly become minimally compliant. We conclude that this vascular construction is stable over the long-term following implantation and may improve the success of small internal diameter arterial reconstruction by eliminating failures caused by intimal hyperplasia.


Assuntos
Prótese Vascular , Grau de Desobstrução Vascular , Animais , Artérias/cirurgia , Cães , Artéria Femoral/cirurgia , Microscopia Eletrônica de Varredura , Elastômeros de Silicone
14.
Dent Clin North Am ; 30(1): 49-67, 1986 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-3514293

RESUMO

Interpore-200 is the product of over 11 years of continuous research and development. It has been investigated at over 25 research centers in a wide variety of animal and human implant settings, including alveolar ridge augmentation, periodontics, and orthognathic reconstructions. The biomaterial aspects of Interpore-200 show the following: Interpore-200 has a highly interconnected, three-dimensional porosity that is uniform and consistent. The hydroxyapatite manufactured from marine corals is biocompatible and nontoxic. Interpore-200 is essentially pure hydroxyapatite, with the balance consisting of tricalcium phosphate. Interpore-200 is approximately 55 to 65 per cent porous with nominal pore diameters of 200 micron. Unlike nonporous materials, Interpore-200 is osteoconductive and results, when placed next to a viable bone, in an advancing front of bone into the implant. From 50 to 88 per cent of the porosity within the implant is filled with woven and lamellar bone within 3 months. Moreover, the surfaces of Interpore-200 are intimately bonded with the bone tissue. The biomechanical properties of Interpore-200 blocks are similar to those of a cancellous bone graft. Once ingrown with vascularized bone tissue, the defect site is, in effect, restored. Interpore-200 adequately matches the elastic properties of bone so that stresses necessary to maintain healthy bone are transmitted throughout the regenerated region. Extensive animal and clinical studies have shown that nonporous implants or implants without interconnected porosity can result in aberrant mineralization, stress shielding, low fatigue strength, and bulk displacement. Hydroxyapatite with interconnected porosity like Interpore-200 reacts differently than materials with limited or no porosity. In animals, Interpore-200 exhibits 0 to 5 per cent biodegradation per year. Moreover, this minimal biodegradation is compensated by regeneration of bone. These studies have now been extended for 4 years. Interpore-200 and its ingrown bone are remodeled in response to the same chemical and biomechanical forces that remodel normal bone. Therefore, Interpore-200 responds in accordance to Wolff's law. Having achieved an optimal combination of biomaterial (hydroxyapatite) in an ideal porous structure (replamineform), Interpore-200 fulfills the expectation of early researchers in the basic sciences who demonstrated that an interconnected porous material is better tolerated by the body than the same material in solid form.(ABSTRACT TRUNCATED AT 400 WORDS)


Assuntos
Materiais Biocompatíveis , Hidroxiapatitas , Próteses e Implantes , Aumento do Rebordo Alveolar , Animais , Biodegradação Ambiental , Fenômenos Biomecânicos , Fenômenos Químicos , Físico-Química , Humanos , Propriedades de Superfície , Fatores de Tempo
15.
Ann Thorac Surg ; 38(6): 627-32, 1984 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-6508417

RESUMO

A method of sustained release implantation has been developed whereby Silastic cylinders, impregnated with benzo[alpha]pyrene (BP) or methylcholanthrene (MCA) each at 2% (low dose) and 10% (high dose) concentrations, were inserted into the bronchus intermedius of hamsters. High-dose BP and MCA, and low-dose MCA had first-order exponential release rates: the half-time of release was 40 days for high-dose BP, 30 days for high-dose MCA, and 165 days for low-dose MCA. Release rate of low-dose BP was a second-order function: half-time of release was 40 days. Atypical squamous metaplasia was noted by 4 weeks in more than 65% of hamsters after insertion of each high-dose carcinogen but in less than 30% with the low-dose carcinogens. Carcinoma in situ was noted approximately 8 weeks after high-dose BP and 19 weeks after low-dose BP. At about 15 to 17 weeks after a high-dose carcinogen, 64% of animals had invasive epidermoid cancer, whereas after a low-dose carcinogen, only 21% did. After 25 weeks of exposure to a high-dose carcinogen, more than 85% of hamsters had invasive epidermoid cancer; up to 52 weeks were required for invasive epidermoid cancer to develop in 30% after a low-dose carcinogen. Measured by image analysis, nuclear deoxyribonucleic acid content of cells with severe atypical squamous metaplasia was greater than tetraploid (mean +/- standard deviation [SD], 3.77 +/- 1.4), whereas cells with invasive epidermoid cancer were suprahexaploid (mean +/- SD, 6.48 +/- 3.6). These differences are significant (p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Benzo(a)pireno/administração & dosagem , Carcinoma de Células Escamosas/induzido quimicamente , Neoplasias Pulmonares/induzido quimicamente , Metilcolantreno/administração & dosagem , Animais , Neoplasias Brônquicas/induzido quimicamente , Neoplasias Brônquicas/patologia , Carcinoma de Células Escamosas/patologia , Transformação Celular Neoplásica/patologia , Cricetinae , DNA/metabolismo , Modelos Animais de Doenças , Implantes de Medicamento , Neoplasias Pulmonares/patologia , Mesocricetus , Fatores de Tempo
16.
J Thorac Cardiovasc Surg ; 86(6): 800-8, 1983 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-6196574

RESUMO

Permanent bioincorporation of a microporous tracheal prosthesis will require a stable blood supply to connective tissue supporting an epithelial surface. In experience with over 80 tracheal implants in dogs, we have observed that end-on ingrowth and epithelialization does not occur in the absence of lateral ingrowth, epithelialization is marked by the appearance of a subepithelial network of vessels, and this process must be well advanced by 6 to 8 weeks for long-term stability. These observations were extended by using microangiography to delineate the blood supply of the prosthesis/tissue complex. Six implants of bioelectric polyurethane with 10% gentamicin (3 cm length, 2 cm diameter, 1 to 1.25 mm wall thickness, 60 to 120 mu micropore diameter) were interposed in the dog thoracic trachea and wrapped with an omental pedicle. The aorta was perfused with a barium suspension at elective sacrifice between 10 weeks and 21 months. Radiographs of specimens were correlated with bronchoscopic, gross, and histopathological findings. Neovascularity of the prosthesis/tissue complex can be described in three categories: outer capsule, prosthetic wall, and inner lining. Outer capsule vessels were oriented circumferentially immediately adjacent to the prosthetic wall. They resembled arteries up to 75 mu diameter on microscopy and appeared to develop from the omentum with connections developing to the bronchial circulation. Prosthetic wall vessels up to 75 mu with thin muscular walls were noted to traverse the porous prosthetic wall. The inner lining had a network of subepithelial vessels that connected to the lamina propria vasculature of the native trachea across the anastomoses with vessels up to 120 mu in diameter. We conclude that the omentum provides an immediate blood supply and a base for early connective tissue ingrowth. Epithelialization occurs as early as 3 weeks on the favorable bed, accompanied by vascular connections to the existing lamina propria tracheal vessels. This dual organization of blood supply with connections across the prosthetic wall is probably important to long-term stability of healing.


Assuntos
Neovascularização Patológica , Omento/cirurgia , Poliuretanos , Próteses e Implantes , Traqueia/cirurgia , Animais , Cães , Células Epiteliais , Omento/irrigação sanguínea , Traqueia/irrigação sanguínea , Traqueia/citologia
17.
Artigo em Inglês | MEDLINE | ID: mdl-6615993

RESUMO

Porosity is an essential component for long term function of small internal diameter synthetic vascular prostheses. Theoretically, porosity is required for healing by providing a scaffold for ingrowth of periprosthetic tissues. Porosity may be required for transfer of fluids and ions in prostheses even if tissue ingrowth does not occur. Increased permeability of vascular grafts has been shown to enhance tissue incorporation. Implants with pore sizes greater than 10 microns but less than 45 microns become ingrown with fibrohistiocytic tissue and capillaries. Implants with pore sizes greater than 45 microns are ingrown with organized fibrous tissue and minimal histiocytic response. The phenomenon of differential ingrowth may have important functional significance. Prostheses which heal with organized fibrous tissue have the potential for long term contracture, strangulation of vascularity and calcification. Fibrohistiocytic tissue has low mechanical strength and does not appear to contract or calcify. Elastomeric microporous vascular prostheses which are minimally ingrown or ingrown with fibrohistiocytic tissue maintain compliance after months of implantation. This study was designated to determine the effects of healing on the compliance of small internal diameter vascular replacements and to correlate the compliance to patency rates.


Assuntos
Prótese Vascular , Cicatrização , Animais , Materiais Biocompatíveis , Complacência (Medida de Distensibilidade) , Cães , Artéria Femoral/cirurgia , Politetrafluoretileno , Poliuretanos , Elastômeros de Silicone , Veias/cirurgia
18.
Artigo em Inglês | MEDLINE | ID: mdl-6615998

RESUMO

Radioactive labeled protein and platelet studies suggest that an ideal vascular surface absorbs albumin and prevents platelet adherence and aggregation. This study examines the interaction of serum and plasma proteins, white cells, and platelets in the thrombotic response to small internal diameter vascular prostheses. Thirty-seven replamineform silicone rubber vascular prostheses, 4 mm internal diameter and 6 cm length, had 5% aspirin and 5% theophylline by weight dispersed in a luminal coating (D); the remaining 37 control (C) prostheses had an identical silicone rubber coating without drugs. Scanning electron and darkfield microscopy confirmed similar surface topography in C and D grafts. One C and one D graft were studied in parallel using a modified canine arteriovenous fistula. Consistently, D prosthesis had increased bleeding through the graft wall. The 7 serum and 8 plasma experiments demonstrated greater accumulation on the D prostheses, the greatest deposition occurring within the first 30 minutes. In 8 platelet experiments, D grafts accumulated more radioactivity at both the 5 and 30 minute intervals. Six mononuclear and 8 PMN experiments had less accumulation on the D grafts at 15 minutes and no consistent difference at 60 minutes. Elution of C and D Grafts demonstrated significant drug levels in only the D grafts at the beginning of the experiments and after 15 minutes of exposure of blood. We conclude: (1) aspirin and theophylline have an effect on the initial interaction of plasma proteins, platelets and white cells in the thrombogenic response, (2) the effect diminishes as time released drug levels decrease.


Assuntos
Coagulação Sanguínea , Plaquetas/fisiologia , Proteínas Sanguíneas/fisiologia , Prótese Vascular , Leucócitos/fisiologia , Animais , Aspirina/administração & dosagem , Materiais Biocompatíveis , Cães , Agregação Plaquetária/efeitos dos fármacos , Elastômeros de Silicone , Teofilina/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...