Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Rep Pract Oncol Radiother ; 23(4): 270-275, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30090026

RESUMO

AIM: To develop a tool in order to guide pre-irradiation dental care (PIDC) for patients with oropharyngeal cancers. BACKGROUND: Osteoradionecrosis of the jaws is a potential complication of radiotherapy (RT) for head and neck cancers. To prevent this complication, PIDC can involve multiple dental extractions as a preventative measure to avoid post-RT complications. However, there is no standardized tool to guide PIDC. MATERIALS AND METHODS: From January 2005 to October 2015, 120 head and neck cancer patients were prospectively included in a study investigating dysgeusia after RT. From this cohort, patients were enrolled according to the following inclusion criteria: histopathological confirmation of oropharyngeal squamous cell carcinoma; stage T1-4 N1-3 M0; ≤10 missing teeth. Individual teeth were retrospectively delineated on planning computed tomography and doses to dentition were assessed to generate templates. RESULTS: Thirty-three patients were included. Molars received highest doses with a mean dose of 50 Gy (range; 19-75 Gy). Ipsi-lateral and contralateral wisdom teeth received RT dose superior to 50 Gy in 92% and 56% of cases, respectively. Patients with advanced disease (T4 or N2c-3) received higher mean doses on inferior and ipsi-lateral dental arches compared to other patients (T1-3 N0-2b): 42 Gy vs. 39 Gy and 44 Gy vs. 39 Gy (p < 0.05), respectively. CONCLUSION: Pre-RT dose distribution templates are an objective way to prepare PIDC. Further studies with a larger cohort are needed to validate these templates.

2.
Int J Radiat Oncol Biol Phys ; 96(4): 848-856, 2016 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-27788956

RESUMO

PURPOSE: To determine the incidence of pseudoprogression (PP) after spine stereotactic body radiation therapy based on a detailed and quantitative assessment of magnetic resonance imaging (MRI) morphologic tumor alterations, and to identify predictive factors distinguishing PP from local recurrence (LR). METHODS AND MATERIALS: A retrospective analysis of 35 patients with 49 spinal segments treated with spine stereotactic body radiation therapy, from 2009 to 2014, was conducted. The median number of follow-up MRI studies was 4 (range, 2-7). The gross tumor volumes (GTVs) within each of the 49 spinal segments were contoured on the pretreatment and each subsequent follow-up T1- and T2-weighted MRI sagittal sequence. T2 signal intensity was reported as the mean intensity of voxels constituting each volume. LR was defined as persistent GTV enlargement on ≥2 serial MRI studies for ≥6 months or on pathologic confirmation. PP was defined as a GTV enlargement followed by stability or regression on subsequent imaging within 6 months. Kaplan-Meier analysis was used for estimation of actuarial local control, disease-free survival, and overall survival. RESULTS: The median follow-up was 23 months (range, 1-39 months). PP was identified in 18% of treated segments (9 of 49) and LR in 29% (14 of 49). Earlier volume enlargement (5 months for PP vs 15 months for LR, P=.005), greater GTV to reference nonirradiated vertebral body T2 intensity ratio (+30% for PP vs -10% for LR, P=.005), and growth confined to 80% of the prescription isodose line (80% IDL) (8 of 9 PP cases vs 1 of 14 LR cases, P=.002) were associated with PP on univariate analysis. Multivariate analysis confirmed an earlier time to volume enlargement and growth within the 80% IDL as significant predictors of PP. LR involved the epidural space in all but 1 lesion, whereas PP was confined to the vertebral body in 7 of 9 cases. CONCLUSIONS: PP was observed in 18% of treated spinal segments. Tumor growth confined to the 80% IDL and earlier time to tumor enlargement were predictive for PP.


Assuntos
Progressão da Doença , Imageamento por Ressonância Magnética , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/mortalidade , Estudos Retrospectivos , Neoplasias da Coluna Vertebral/mortalidade , Fatores de Tempo , Carga Tumoral
3.
J Med Imaging Radiat Oncol ; 60(2): 255-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26568515

RESUMO

INTRODUCTION: We assessed the inter- and intra-observer variability in contouring the prostate bed for radiation therapy planning using MRI compared with computed tomography (CT). METHODS: We selected 15 patients with prior radical prostatectomy. All had CT and MRI simulation for planning purposes. Image fusions were done between CT and MRI. Three radiation oncologists with several years of experience in treating prostate cancer contoured the prostate bed first on CT and then on MRI. Before contouring, each radiation oncologist had to review the Radiation Therapy Oncology Group guidelines for postoperative external beam radiotherapy. The agreement between volumes was calculated using the Dice similarity coefficient (DSC). Analysis was done using the Matlab software. The DSC was compared using non-parametric statistical tests. RESULTS: Contouring on CT alone showed a statistically significant (P = 0.001) higher similarity between observers with a mean DSC of 0.76 (standard deviation ± 0.05) compared with contouring on MRI with a mean of 0.66 (standard deviation ± 0.05). Mean intra-observer variability between CT and MRI was 0.68, 0.75 and 0.78 for the three observers. The clinical target volume was 19-74% larger on CT than on MRI. The intra-observer difference in clinical target volume between CT and MRI was statistically significant in two observers and non-significant in the third one (P = 0.09). CONCLUSIONS: We found less inter-observer variability when contouring on CT than on MRI. Radiation Therapy Oncology Group contouring guidelines are based on anatomical landmarks readily visible on CT. These landmarks are more inter-observer dependent on MRI. Therefore, present contouring guidelines might not be applicable to MRI planning.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X/métodos , Pontos de Referência Anatômicos/diagnóstico por imagem , Humanos , Masculino , Variações Dependentes do Observador , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
IEEE Trans Med Imaging ; 26(11): 1428-36, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18041258

RESUMO

An improved method for the combination of signals from array coils is presented as a way to reduce the influence of the noise floor on the estimation of diffusion tensor imaging (DTI) parameters. By an optimized combination of signals from the array channels and complex averaging of measurements, this method leads to a significant reduction of the noise bias. This combination algorithm allows computation of accurate tensors by using the simple two point method and is shown to provide results similar to the ones obtained using the standard signal combination and a nonlinear regression method with noise parameter estimation. In many applications, the use of this combination method would result in a scan time reduction in comparison to the current standard. The effects of the improved combination on diffusion decay curves, fractional anisotropy maps, and apparent diffusion coefficient (ADC) profiles are demonstrated.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Humanos , Interpretação de Imagem Assistida por Computador/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...