Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 121(6): 967.e1-967.e6, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31109725

RESUMO

STATEMENT OF PROBLEM: Analysis of the wear coefficient (k) of the superficial and deep layers of acrylic resin teeth can help predict denture durability, but little has been published on the wear coefficient of denture teeth. PURPOSE: The purpose of this in vitro study was to determine the k value for the superficial and deep layers of the acrylic resin teeth of 6 different brands by using the fixed-ball microabrasive wear method. MATERIAL AND METHODS: Six artificial tooth specimens of 4 commercial brands were tested: Artiplus IPN (Ar), Biotone IPN (Bi), Magister (Ma), Premium (Pr), Trilux (Tr), and SR Vivodent (Vi). Two specimens from each brand were created, one for the superficial layer and the other for the deep layer. The test was performed on fixed-ball microabrasive wear equipment set to operate at a constant normal force of 0.5 N and a rotation speed of 100 rpm. The test time periods were 5.00, 8.33, and 11.66 minutes. The characteristics of the wear craters were measured by using an optical microscope at a magnification of ×50 and Leica Microsystems software. Wear coefficient (k) values were deduced by using the Archard equation for abrasive wear, Q=k·N, and were analyzed by using 1-way analysis of variance, complemented by the Tukey HSD test (α=.05). A different analysis was used for each layer. RESULTS: The analysis of variance of the wear coefficient revealed significant differences among the groups regarding the superficial layers (P=.009). The Tukey HSD test showed that the k values for the superficial layers of Artiplus specimens were significantly lower than those of the Vivodent and Magister specimens. CONCLUSIONS: One brand (Ar) presented significantly lower wear coefficient value for the surface layer. No difference in wear coefficient values was found among the tooth brands for the deep layer.


Assuntos
Resinas Acrílicas , Dente Artificial , Dentaduras , Teste de Materiais , Propriedades de Superfície
2.
Psychiatry Res Neuroimaging ; 272: 71-78, 2018 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-29229240

RESUMO

Schizophrenia is a severe mental disorder that affects the anatomy and function of the brain, with an impact on one's thoughts, feelings, and behavior. The purpose of the study was to investigate cerebral blood flow (CBF) and brain connectivity in a group of patients with schizophrenia. Pseudo-continuous arterial spin labeling (pCASL) images were acquired from 28 patients in treatment and 28 age-matched healthy controls. Mean CBF and connectivity patterns were assessed. Schizophrenia patients had decreased CBF in the bilateral frontal pole and superior frontal gyrus, right medial frontal gyrus, triangular and opercular parts of the inferior frontal gyrus, posterior division of the left supramarginal gyrus, superior and inferior divisions of the left lateral occipital cortex, and bilateral occipital pole. Moreover, through different methods to assess connectivity, our results showed abnormal connectivity patterns in regions involved in motor, sensorial, and cognitive functions. Using pCASL, a non-invasive technique, we found CBF deficits and altered functional organization of the brain in schizophrenia patients that are associated with the symptoms and characteristics of the disorder.


Assuntos
Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Esquizofrenia/fisiopatologia , Marcadores de Spin , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Mapeamento Encefálico , Estudos de Casos e Controles , Cognição , Feminino , Humanos , Masculino , Esquizofrenia/diagnóstico por imagem
3.
J Acquir Immune Defic Syndr ; 66(4): 378-85, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-24798768

RESUMO

OBJECTIVE: Data on the interaction between the etonogestrel (ENG) implant and antiretroviral therapy are lacking. We evaluated the effect of 2 highly active antiretroviral therapy (HAART) regimens (1 including efavirenz and the other ritonavir-boosted lopinavir) on the pharmacokinetic (PK) parameters of an ENG-releasing implant in HIV-positive women. DESIGN: Prospective nonrandomized PK study. METHODS: Forty-five HIV-positive women who desired to use ENG implants were included: 15 had received zidovudine/lamivudine + lopinavir/ritonavir for ≥3 months (LPV/r-based HAART group), 15 had received zidovudine/lamivudine + efavirenz for ≥3 months (EFV-based HAART group), and 15 had not received HAART (non-HAART group). PK parameters were measured using ultra-performance liquid chromatography-mass spectrometry at baseline and 2, 4, 6, 8, 10, 12, 16, 20, and 24 weeks after implant placement. RESULTS: The EFV-based HAART regimen was associated with a reduction in the bioavailability of ENG, which showed decreases of 63.4%, 53.7%, and 70% in the area under the curve (AUC), maximum concentration (Cmax), and minimum concentration (Cmin) of ENG, respectively, compared with the non-HAART group. The LPV/r-based HAART regimen was associated with an increase in ENG bioavailability, which showed 52%, 60.6%, and 33.8% increases in the ENG AUC, Cmax, and Cmin, respectively, compared with the non-HAART group. CONCLUSIONS: The coadministration of EFV decreased the bioavailability of ENG released from the implant, which could impair contraceptive efficacy. However, the coadministration of LPV/r increased the bioavailability of ENG released from the implant, which suggests that this antiretroviral combination does not impair the ENG implant efficacy.


Assuntos
Fármacos Anti-HIV/uso terapêutico , Benzoxazinas/uso terapêutico , Desogestrel/farmacocinética , Infecções por HIV/tratamento farmacológico , Lopinavir/uso terapêutico , Ritonavir/uso terapêutico , Adulto , Alcinos , Terapia Antirretroviral de Alta Atividade , Disponibilidade Biológica , Anticoncepcionais Femininos/farmacocinética , Ciclopropanos , Combinação de Medicamentos , Implantes de Medicamento , Interações Medicamentosas , Feminino , Humanos , Adulto Jovem
4.
Alcohol Clin Exp Res ; 34(8): 1417-24, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20491736

RESUMO

BACKGROUND: This study was aimed at assessing the psychometric qualities of the abbreviated versions of the Alcohol Use Disorders Identification Test (AUDIT-3, AUDIT-4, AUDIT-C, AUDIT-PC, AUDIT-QF, FAST, and Five-Shot) and at comparing them to the 10-item AUDIT and the CAGE in 2 samples of Brazilian adults. METHODS: The validity and internal consistency of the scales were assessed in a sample of 530 subjects attended at an emergency department and at a Psychosocial Care Center for Alcohol and Drugs. The Structured Clinical Interview for DSM-IV was used as the diagnostic comparative measure for the predictive validity assessment. The concurrent validity between the scales was analyzed by means of Pearson's correlation coefficient. RESULTS: The assessment of the predictive validity of the abbreviated versions showed high sensitivity (of 0.78 to 0.96) and specificity (of 0.74 to 0.94) indices, with areas under the curve as elevated as those of the AUDIT (0.89 and 0.92 to screen for abuse and 0.93 and 0.95 in the screening of dependence). The CAGE presented lower indices: 0.81 for abuse and 0.87 for dependence. The analysis of the internal consistency of the AUDIT and its versions exhibited Cronbach's alpha coefficients between 0.83 and 0.94, while the coefficient for the CAGE was 0.78. Significant correlations were found between the 10-item AUDIT and its versions, ranging from 0.91 to 0.99. Again, the results for the CAGE were satisfactory (0.77), although inferior to the other instruments. CONCLUSIONS: The results obtained in this study confirm the validity of the abbreviated versions of the AUDIT for the screening of alcohol use disorders and show that their psychometric properties are as satisfactory as those of the 10-item AUDIT and the CAGE.


Assuntos
Transtornos Relacionados ao Uso de Álcool/diagnóstico , Inquéritos e Questionários/normas , Adulto , Transtornos Relacionados ao Uso de Álcool/psicologia , Manual Diagnóstico e Estatístico de Transtornos Mentais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Psicometria , Adulto Jovem
5.
Nicotine Tob Res ; 11(10): 1160-5, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19596727

RESUMO

INTRODUCTION: This study examined the psychometric properties of the Brazilian versions of the Fagerström Test for Nicotine Dependence (FTND) and the Heaviness of Smoking Index (HSI). METHODS: The test-retest reliability of the FTND was assessed in a sample of 61 smoking university students, with a 15-day interval between assessments. The interrater reliability was examined in 30 smoking patients of a psychosocial care center for alcohol and drug users (PCC-AD). The reliability coefficient was estimated by the kappa and intraclass correlation coefficients. The predictive validity, internal consistency, and factor structure of the FTND and the HSI were evaluated by factor analysis in 271 smokers treated at an emergency unit and at the PCC-AD. The gold standard was the nicotine dependence criteria of DSM-IV, as assessed by the Structured Clinical Interview for DSM-IV. RESULTS: The FTND showed high reliability, with correlation coefficients of .92 for test-retest reliability and .99 for interrater reliability. Both the FTND and the HSI presented high levels of sensitivity and specificity. The internal consistency evaluation yielded a Cronbach's alpha coefficient of .83 for the FTND and of .56 for the HSI. An exploratory factor analysis found 2 factors in the FTND, which were validated by a confirmatory factor analysis. DISCUSSION: The results obtained in this study confirm the validity and reliability of the Brazilian versions of the FTND and the HSI.


Assuntos
Psicometria , Tabagismo , Brasil , Análise Fatorial , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
6.
Ophthalmic Epidemiol ; 15(4): 272-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18780261

RESUMO

PURPOSE: To determine the prevalence of trachoma in Sao Gabriel da Cachoeira (SGC), the only urban community of the upper Rio Negro Basin of the Amazon state in Brazil, near the Colombian border, and to investigate the risk factors associated with the active forms of the disease. METHODS: A total of 1702 people (440 children up to 9 years and 1069 adults aged 15 years and above) were examined. The sample was selected from a probabilistic household sampling procedure based on census data and a previous study of trachoma prevalence in Sao Gabriel da Cachoeira. A two-stage probabilistic household cluster sample was drawn. Household units were randomly selected within each cluster. A variety of socioeconomic and hygiene variables were studied in order to determine the risk factors for active trachoma in a household. RESULTS: The total prevalence of trachoma was 8.9%. Prevalence of active trachoma (TF and/or TI) in children aged 1-9 years was 11.1% and trachomatous trichiasis in adults aged 15 years and above was 0.19%. Trachomatous scarring reached a peak of 22.4% for subjects between 50 to 60 years of age. Corneal opacity occurred in subjects aged 50 years and older with a prevalence of 2.0%. No sex effect was found on the overall prevalence of trachoma in SGC. Risk factors associated with active trachoma were mainly related to poor socioeconomic indicators. CONCLUSIONS: Despite the ubiquitous presence of water, the analysis of the risk factors associated with the active forms of the disease supports the idea that a low personal standard of hygiene and not water availability per se, is the key factor associated with trachoma.


Assuntos
Tracoma/epidemiologia , Adolescente , Adulto , Brasil/epidemiologia , Criança , Pré-Escolar , Feminino , Inquéritos Epidemiológicos , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco
7.
J Adhes Dent ; 6(4): 267-73, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15779310

RESUMO

PURPOSE: The objective of this study was to analyze the stress concentration factor (Kt) in specimens of uniform material with the most commonly used geometry (square hourglass) during microtensile tests using finite element analysis. Standardization is emphasized with the aim of obtaining the most representative nominal strength of the material. METHODS: Eighty cases were simulated using three-dimensional models, in which we varied the fixation of specimens in the jig (f = 1 or 2 sides), the height of this fixed region (h = 1 or 2.75 mm), the specimen width (D = 1.5, 2, 3, 4 or 5 mm), and the radius of curvature of the notch (r = 0.2, 0.5, 0.7 or 1 mm). The cross-sectional area (1 mm2) remained constant in all analyses. The stress concentration factor Kt (maximum tensile stress/nominal tensile stress) was calculated. RESULTS: A 150% difference was observed from the lowest Kt value (1.3) to the highest one (3.2). Results indicated that the radius of curvature is a very influential geometric parameter in microtensile strength tests (variation in Kt values up to 47.4%). For two-side fixed specimens, the Kt values varied from 3 to 4%, while the one-side fixed models resulted in variations from 11 to 15%. CONCLUSION: Variations in the specimen geometry and mode of load application can be responsible for part of the different strength values obtained in microtensile tests. The specimen fixation by two sides is a simple and easily performed method to reduce the stress concentration factor and its variations induced by specimen geometry and test assembly.


Assuntos
Resinas Acrílicas/química , Resinas Compostas/química , Análise do Estresse Dentário/métodos , Teste de Materiais/métodos , Poliuretanos/química , Análise de Elementos Finitos , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...