Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Arch Orthop Trauma Surg ; 143(6): 3649-3657, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36178493

RESUMO

INTRODUCTION: Breakage of exchangeable-neck (EN) and adverse local tissue reactions (ALTRs) to neck-stem junction (NSJ) damage products are responsible for increasing the revision rate of EN hip prostheses. We investigated the survivorship of an EN hip prosthesis including a NSJ with both components made of titanium alloy (Ti-alloy/Ti-alloy) to assess whether, and to what extent, EN breakage and NSJ damage affected implant survivorship. MATERIALS AND METHODS: Using data from a hip replacement registry, we determined survivorship of 2857 EN prostheses. Long-offset configurations of head and EN were implanted in heavy (> 90 kg) patients only in 23 hips. We investigated under which conditions EN breakages or ALTRs occurred. We also measured titanium (Ti) and vanadium (V) blood concentrations in 24 patients with a unilateral well-working prosthesis. RESULTS: The 17-year survival rates for any reason and aseptic loosening of any component were 88.9% (95%CI 87.5-90.1; 857 hips at risk) and 96.9% (95%CI 96.0-97.6), respectively. There were two cases of EN breakage and one case of ALTR (metallosis), due to rim-neck impingement, out of 276 revisions. After an average period of 9.8 years (range 7.8-12.8 years), the maximum Ti and V blood concentrations in patients with a well-working prosthesis were 5.0 µg/l and 0.16 µg/l, respectively. CONCLUSION: The present incidence of EN breakage or ALTR is lower than those reported in other studies evaluating EN hip prosthesis survivorship. This study suggests that (i) the risk of EN breakage is reduced by limiting the use of long-offset configurations in heavy patients and (ii) Ti-alloy/Ti-alloy NSJ damage products do not promote ALTR nor significantly alter the rate of implant loosening. Since design decisions and implant configuration determine the NSJ strength, the NSJ strength in working conditions must be thoroughly investigated to proper define the clinical indications for any EN design.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Prótese de Quadril/efeitos adversos , Ligas , Titânio , Sobrevivência , Desenho de Prótese , Artroplastia de Quadril/efeitos adversos , Falha de Prótese , Reoperação/efeitos adversos
2.
Proc Inst Mech Eng H ; 234(12): 1353-1362, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32605498

RESUMO

Despite the encouraging short- and medium-term clinical results and increased usage of reverse shoulder replacements, a higher revision rate is documented compared with other major joint arthroplasties. Adverse reaction to polyethylene wear debris is still an important factor which may influence the long-term survival of reverse shoulder arthroplasty. To date, only a small number of retrieval studies of reverse shoulder arthroplasty have reported the different damage modes on polyethylene components, but none have quantified the ex vivo surface roughness on both articulating surfaces. The main purpose of this study was to assess, for the first time, the surface roughness of 13 retrieved metal-on-polyethylene reverse shoulder replacements using a white light profilometre with nanometre resolution. Although no significant relationship was observed between the surface roughness values and patient variables, it was noted that half of the polyethylene components still showed their original machining marks, indicating little change in vivo and that the metallic humeral components in the reversed design configuration showed low values of surface roughness after their time in vivo.


Assuntos
Prótese Articular , Prótese de Ombro , Análise de Falha de Equipamento , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese
3.
J Mater Sci Mater Med ; 31(7): 56, 2020 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-32594253

RESUMO

INTRODUCTION: Ceramic-on-ceramic couplings demonstrated to be reliable bearings in primary total hip arthroplasty (THA), with long-term remarkable results. Like-on-like configurations were widely described. On the contrary, mixed material combinations from the same manufacturer, Delta-on-Forte or Forte-on-Delta, were poorly studied. In particular, it is unknown whether mixed ceramic combinations are more at risk of ceramic fractures. Thus, a registry study was conducted to investigate the long-term survival rates and reasons for revision of mixed ceramic combinations. A comparison with Delta-on-Delta couplings was also performed. MATERIALS AND METHODS: The regional arthroplasty registry RIPO was enquired about three cohorts of ceramic bearings (head-on-liner: Delta-on-Forte, Forte-on-Delta, Delta-on-Delta). Demographics, survival rates and reasons for revision were evaluated and compared. RESULTS: In total, 346 (1.5%) implants had a Delta-on-Forte coupling (mean follow-up: 6.4 years). In total, 1163 (5%) THAs had a Forte-on-Delta articulation (mean follow-up: 8.2 years). Delta-on-Delta surfaces were implanted in 21,874 (93.5%) hips (mean follow-up: 3.9 years). Mixed material combinations were implanted between 2003 and 2007. The survival rates of the three cohorts were similar and were higher than 95% at 10 years. In Forte-on-Delta group, four liners failed (0.3% of the implants), whereas ceramic fractures occurred in 15 cases (0.1%) in Delta-on-Delta couplings (3 heads and 12 liners). Considering ceramic fracture as endpoint, there was no significant difference between the three survival rates. CONCLUSIONS: Mixed ceramic bearing configurations from the same manufacturer in primary THA showed mid-to-longterm dependable outcomes, not inferior to the most recent like-on-like ceramic bearings. No additional risks of ceramic fractures were evident. Thus, closer follow-ups are not required.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Cerâmica/química , Prótese de Quadril , Idoso , Artroplastia de Quadril/estatística & dados numéricos , Cerâmica/uso terapêutico , Estudos de Coortes , Análise de Falha de Equipamento/estatística & dados numéricos , Feminino , Seguimentos , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Próteses Articulares Metal-Metal/efeitos adversos , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
4.
Hip Int ; 30(4): 438-445, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31328560

RESUMO

INTRODUCTION: Noise in ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is a potential symptom of abnormal bearing wear. Squeaking and other prosthetic hip noises are multi-factorial phenomena that can be analysed and may provide prognostic information. METHODS: 46 patients with noisy CoC bearings were investigated using X-ray, computed tomography and joint fluid analysis, and classified into either high or low risk of ceramic liner fracture groups according to previously published guidelines. Noise events from the bearings of 16 high risk cases which were subsequently revised were compared with 30 patients in the low risk control group who did not undergo revision. Noise events were analysed for their physical characteristics using a standardised protocol and classified as either low frequency and short duration 'clicking' or long duration and high frequency 'squeaking'. RESULTS: The peak frequency of squeaking during forward walking was significantly higher for patients in the case group who were revised, compared with the control group. The patient-reported onset of squeaking (46 months postoperatively) was earlier than short-noise emissions (82 months). In the standardised sequence of movements, short-noise always occurred more frequently than squeaking. Small heads (28 mm) were more likely to develop short-noise, while large heads (⩾32 mm) were more likely to develop squeaking. DISCUSSION: Noise evaluation may provide additional value for predicting failure of CoC bearings, though some questions should be better investigated in a dedicated prospective trial.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Cerâmica , Prótese de Quadril/efeitos adversos , Ruído , Complicações Pós-Operatórias/diagnóstico , Adulto , Idoso , Artroplastia de Quadril/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Radiografia , Fatores de Tempo
7.
Orthop Traumatol Surg Res ; 105(7): 1251-1256, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31615748

RESUMO

BACKGROUND: Body mass index is used by the World Health Organization to classify obesity. While obesity influences the onset of arthritis and type-2 diabetes, its effect on implant survival is still open to debate, with conflicting results from clinical and registry studies, as well as meta-analyses. Other known factors such as gender or diabetes status could ponderate or mask the effect of BMI on implant survival. HYPOTHESIS: Our hypothesis was BMI influenced hip and knee arthroplasty survival, when results were made independent of gender and diabetes status. PATIENT AND METHODS: A registry study was designed on 30733 Total Hip Arthroplasties (THA), 28483 Total Knee Arthroplasties (TKA), 3754 Uni compartmental Knee Arthroplasties (UKA) and 649 Hinged Knee arthroplasties (HK), from 01/01/2003 to 31/12/2015. Mean follow-up was 5.5 years. Diabetes status was added to the model. Each arthroplasty survival was tested for age at implantation, gender, diabetes status, implant characteristics and specifically BMI, taking into account gender and diabetes status. RESULTS: Gender had a strong influence on arthroplasty results. Age also influenced arthroplasty survival, especially aseptic loosening; a young age would lower implant survival. Diabetes had an influence in hip survival, but its influence on septic loosenings in TKA wasn't proven (p=0.065). A mobile liner and/or a cruciate retaining knee were factors increasing the risk of revision. Weight influenced THA survival, especially aseptic loosening, but didn't have a measurable effect in any other arthroplasty. BMI was not found to influence any arthroplasty survival, whatever the endpoint, when diabetes and gender were taken into account. DISCUSSION: Gender, age and diabetes influenced survival of the lower limb arthroplasties, whereas BMI did not. Only weight did influence THA results and should be used instead of BMI. CONCLUSION: Studies on arthroplasty survival should systematically mention gender and diabetes status and beware of potential group incomparability. LEVEL OF EVIDENCE: III, cohort study.


Assuntos
Artroplastia de Quadril/mortalidade , Artroplastia do Joelho/mortalidade , Adulto , Idoso , Artroplastia de Quadril/reabilitação , Artroplastia do Joelho/reabilitação , Estudos de Coortes , Comorbidade , Diabetes Mellitus Tipo 2 , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Análise de Sobrevida
8.
Clin Lab ; 65(6)2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31232020

RESUMO

BACKGROUND: Ischemia-modified albumin (IMA) derives from naive albumin, modified in the binding region of bivalent ions, as cobalt and iron. The cobalt, released from some types of hip prosthesis seems to be metabolized differently in males and females but the iron ion is more prevalent than cobalt and is detectable in the healthy population. Our aim was to verify if there are any gender- and age-related differences in IMA concentrations and if IMA correlates with cobalt and iron-related proteins. METHODS: IMA, albumin, iron, ferritin, transferrin, and cobalt were measured in 50 men and 50 women divided into two age/fertility-homogeneous groups. RESULTS: Men < 45-years-old showed a statistically significant lower IMA concentration than men ≥ 45 and fertile and menopausal women. Considering all the population studied, IMA does not seem to be correlated with age and is distributed differently by gender; also, Co distribution was different between males and females. CONCLUSIONS: IMA did not correlate with cobalt, iron, ferritin, and transferrin in any group, except for fertile women where IMA presented a statistically significant correlation with serum iron values. Minor expression of IMA in young males together with the results obtained on serum iron in fertile females, could explain the higher accumulation of circulating Co in women compared to men and their different cobalt metabolism.


Assuntos
Biomarcadores/sangue , Cobalto/sangue , Ferro/sangue , Adulto , Estudos de Casos e Controles , Feminino , Ferritinas/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Albumina Sérica/metabolismo , Albumina Sérica Humana , Fatores Sexuais , Transferrina/metabolismo
9.
J Arthroplasty ; 34(9): 2065-2071, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31160152

RESUMO

BACKGROUND: Fourth-generation ceramic-on-ceramic couplings were developed to improve ceramic toughness and strength. Encouraging outcomes in primary total hip arthroplasty were reported. This coupling was proposed as an attractive option even in the case of revision procedures, particularly in younger patients with a longer life expectancy. However, the pertinent literature is scarce. Thus, a registry study was conducted to investigate the midterm survival rates and reasons for re-revision of the fourth-generation ceramic-on-ceramic bearing surfaces in revision hip arthroplasties. METHODS: A total of 327 revision implants (all the components were exchanged) with BIOLOX Delta couplings were investigated using the regional orthopedic registry RIPO. The demographics, the survival rates, and the reasons for re-revision were assessed. Revisions with bearings other than Delta were compared. RESULTS: Delta bearings achieved a survival rate of 90.5% at 7 years, with stable results. Twenty-six (8%) re-revisions occurred at a mean follow-up of 4.1 years. And 2.8% of the re-revisions were due to recurrent dislocations; 1.5% of the cases were due to cup aseptic loosening. Septic loosening occurred in 1.6% of the cases. No ceramic fractures were reported. When compared to revisions with bearings other than Delta-on-Delta, Delta coupling cohort achieved similar performances at 5 and 7 years. Lower, nonsignificant rates of aseptic and septic loosening were reported in Delta cohort. CONCLUSION: Delta-on-Delta couplings demonstrated to be reliable bearing surfaces in revision settings at a midterm follow-up. Clinical studies and longer follow-ups are required to investigate potential adverse effects, like squeaking and fractures, and confirm these preliminary findings. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cerâmica/química , Prótese de Quadril/efeitos adversos , Reoperação/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Feminino , Fraturas Ósseas/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
10.
EFORT Open Rev ; 4(6): 423-429, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31210979

RESUMO

The purpose of this paper is to determine the prevalence of metal-on-metal (MoM) total hip replacement (THR) in European registries, to assess the incidence of revision surgery and to describe the national follow-up guidelines for patients with MoM THR including resurfacings.Eleven registries of the Network of Orthopaedic Registries of Europe (NORE) participated totalling 54 434 resurfacings and 58 498 large stemmed MoM THRs.The resurfacings and stemmed large head MoM had higher pooled revision rates at five years than the standard total hip arthroplasties (THA): 6.0%, 95% confidence interval (CI) 5.3 to 6.8 for resurfacings; 6.9%, 95% CI 4.4 to 9.4 for stemmed large head MoM; and 3.0%, 95% CI 2.5 to 3.6 for conventional THA.The resurfacings and stemmed large head MoM had higher pooled revision rates at ten years than the standard THAs: 12.1%, 95% CI 11.0 to 13.3 for resurfacings; 15.5%, 95% CI 9.0 to 22 for stemmed large head MoM; and 5.1%, 95% CI 3.8 to 6.4 for conventional THA.Although every national registry reports slightly different protocols for follow-up, these mostly consist of annual assessments of cobalt and chromium levels in blood and MRI (MARS) imaging. Cite this article: EFORT Open Rev 2019;4 DOI: 10.1302/2058-5241.4.180078.

11.
Orthop Traumatol Surg Res ; 105(4): 627-631, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31027978

RESUMO

BACKGROUND: Bilateral cases, representing at least 25% of total knee arthroplasties (TKA), could convey a statistical bias linked to dependency. Registries allow exploring this issue, susceptible to question surgeon validated protocols. Do bilateral total knee arthroplasties behave differently than unilateral knees in terms of implant survival? HYPOTHESIS: Bilateral TKA have a better survival than unilateral TKA. PATIENTS AND METHODS: A number of 14,652 bilateral and 27,440 unilateral TKAs were compared. Influencing factors were tested with hazard ratios applied on bilateral knees. RESULTS: Bilateral knees had a better survival (p<0.001). Delay between first and second side surgeries had an influence on survival of the first knee: if below a year, the first knee survival was superior to the second knee; more than three years between both arthroplasties significantly decreased the survival of the first implant. If the first knee was revised, the hazard ratio for revision of the second implant was 3.5. DISCUSSION: Series should include separate evaluations of bilateral cases, because they have a better survival than unilateral knees. A long delay between both knee replacements could impact both implant survivals. Level of Evidence III, Cohort Comparative Study.


Assuntos
Artroplastia do Joelho/estatística & dados numéricos , Prótese do Joelho , Falha de Prótese , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Modelos de Riscos Proporcionais , Sistema de Registros , Reoperação , Fatores de Risco , Fatores de Tempo
12.
J Orthop Sci ; 24(4): 643-651, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30612885

RESUMO

BACKGROUND: In ceramic-on-ceramic (CoC) total hip arthroplasty (THA), component positioning demonstrated to influence the bearing damage: however the connection between angles and clinical outcomes at long-term follow-ups is currently lacking. Aims of this study were: the computer tomography (CT) assessment of component positioning in CoC THAs; the correlation analysis between positioning and ceramic damage; the identification of safe zones. METHODS: 91 consecutive post-operative CT scans including two types of CoC implants, with a mean follow-up of 12 ± 4.4 years, were evaluated. III generation (74.2%) and IV generation (25.8%) CoC surfaces were included. The angle measurements (cup abduction, anteversion, cup tilt, stem antetorsion, sacral slope) were automated using a CT-based software. The combined anteversion was assessed as well as the cup-neck position at -15°, 0°, 45° and 90° of flexion. Ceramic damage was diagnosed using synovial fluid analyses and radiological criteria. RESULTS: 63.7% of THAs was inside the cup abduction target 30°-45° and 68.1% was inside the cup anteversion target 5°-25°. 19 patients (20.9%) showed signs of ceramic damage. High cup abduction and high cup-neck 45° minimum angle (which stood for high abduction and extreme combined version) significantly correlated with ceramic damage. No demographical features apart III generation ceramic bearings influenced the results. No safe zones could be detected. CONCLUSIONS: In CoC THA, no safe zones can be described. However it is important to avoid cup inclination over 45° and a combination of steep cup and extreme combined version.


Assuntos
Artroplastia de Quadril/instrumentação , Cerâmica , Prótese de Quadril/efeitos adversos , Osteoartrite do Quadril/diagnóstico por imagem , Desenho de Prótese , Falha de Prótese/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Amplitude de Movimento Articular , Tomografia Computadorizada por Raios X
13.
Int Orthop ; 43(8): 1815-1821, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30141142

RESUMO

PURPOSE: Highly porous cups were developed to improve osseointegration and reduce the rate of aseptic loosening. Highly porous titanium cups could mix the reliability of titanium metal with an enhanced porosity, improving the bony ingrowth. The aim of this report was to assess the survival rates and reasons for revision of a highly porous titanium cup, Fixa Ti-Por (Adler Ortho, Milan, Italy), fabricated using an additive manufacturing. METHODS: The Registry of Prosthetic Orthopedic Implants (RIPO), the Emilia-Romagna region arthroplasty registry, was enquired about cementless cups, implanted since July 2007. Ti-Por cups were compared to all the other cementless sockets, acting as a control group. The survival rates and reasons for revision were evaluated and compared. Comparisons with the same articular couplings were also provided. RESULTS: When all the articular couplings were included, Ti-Por performed better, achieving a statistically higher survival rate than the control group (98.7% vs 97.9%) and a statistically lower incidence of cup aseptic loosening. In case of ceramic on polyethylene couplings, Ti-Por achieved similar survival rate: cup aseptic loosening in Ti-Por group was 0.2%, whereas the control group rated 0.4%. In ceramic-on-ceramic implants, the survival rate was similar in the two groups, Ti-Por achieving a cup aseptic loosening rate of 0.1% (vs 0.14% in the control group). CONCLUSION: Highly porous titanium cups showed trustworthy results at eight years, reducing the rate of aseptic loosening. Longer follow-ups, ion analyses, and pre-clinical in vivo studies would be helpful to better define the reliability of these devices and their advantages.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Materiais Biocompatíveis , Feminino , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Porosidade , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Titânio , Adulto Jovem
14.
Int Orthop ; 43(1): 103-109, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30099642

RESUMO

PURPOSE: Periprosthetic hip infection (PHI) is a devastating complication. The association between PHI and bearing surfaces as well as patient-related factors has been recently investigated, with contradictive outcomes. The dataset of Emilia-Romagna region Registry for Orthopaedic Prosthetic Implants (RIPO) has been assessed to investigate, if the bearing choice influenced the risk of septic loosening occurrence. METHODS: RIPO data about 39,206 cementless total hip arthroplasties (THA), collected since 2003, were analysed. Age, gender, BMI, diabetes and bearing surfaces were evaluated. The end point of the study was the revision of at least a single component due to sepsis. RESULTS: Adjusted and unadjusted survival rates showed that ceramic-on-ceramic (COC) implants had the lower incidence of PHIs, whereas metal-on-metal (MOM) THAs were significantly more prone to infection. In MOM cohort, stemmed implants were involved in 28 out of 30 cases. Among the demographical features and comorbid conditions, only diabetes statistically influenced the rate of sepsis. CONCLUSIONS: Bearing surfaces influenced the rate of PHI; in particular, stemmed MOM implants were at higher risk, probably due to metal debris consequent to taperosis. Despite the preliminary results, stemmed MOM THAs should be used with care, and diabetic patients should be warned about increased septic risks.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese/efeitos adversos , Falha de Prótese/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/terapia , Sistema de Registros , Reoperação , Fatores de Risco , Adulto Jovem
15.
Knee Surg Sports Traumatol Arthrosc ; 27(9): 3041-3047, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30539306

RESUMO

PURPOSE: The aim of this study was to assess whether preoperative valgus or varus deformity affected survivorship after total knee arthroplasty (TKA) and to quantify the risk factors for implant failure in a registry-based population. METHODS: The Emilia-Romagna Registry of Prosthetic Orthopedic Implants was examined regarding TKAs performed on patients with a preoperative diagnosis of valgus or varus deformity. Demographics, implant characteristic and survivorships were investigated and compared. A total of 2327 TKA procedures performed from 2000 to 2016 were included in the study. Six hundred and forty primary TKAs with a diagnosis of valgus deformity were evaluated with a median follow-up of 3.3 years; 1687 primary TKAs with a diagnosis of varus deformity were evaluated with a median follow-up of 2.5 years. RESULTS: Bi-compartmental, cemented posterior stabilised fixed-bearing implants were preferred. For both diagnoses, the implant survivorship rate was greater than 98% in the first year. However, the survival curve of the TKAs implanted for valgus deformity showed a greater slope in the first 3 years as compared to the survival curve of those implanted for varus deformity. Valgus deformity had a 2.1-fold higher risk for revision as compared with varus deformity. Infection was a major cause of implant failure in TKAs for varus deformity, 9/24 (37.5%), while its incidence was lower for valgus deformity, 1/21 (4.8%). CONCLUSIONS: Preoperative valgus alignment showed a twofold risk of failure as compared to varus alignment after TKA. This should be considered in daily practice, and surgeons are called on to pay more attention when performing TKAs on such patients. Prospective randomised controlled trials are, therefore, necessary to better understand the role of preoperative coronal knee deformity in implant failure. LEVEL OF EVIDENCE: Prognostic study, level III.


Assuntos
Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Coxa Vara/fisiopatologia , Geno Valgo/fisiopatologia , Articulação do Joelho/anormalidades , Articulação do Joelho/cirurgia , Prótese do Joelho , Sistema de Registros , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Ortopedia/métodos , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Reoperação , Fatores de Risco , Resultado do Tratamento
16.
J Arthroplasty ; 33(6): 1794-1799, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29395723

RESUMO

BACKGROUND: Short stems in total hip arthroplasty (THA) have recently gained increasing popularity, allowing mini-invasive exposures and bone-sparing approaches. However, long-term studies and recommendations for the routine use are not available. The aim of this report was to compare the survival rates and the reasons for revision of short stems versus conventional stems in cementless THAs, in a registry-based population. METHODS: The Registry of Prosthetic Orthopedic Implants (RIPO) was inquired about cementless THAs performed since 2000 to 2016. The stems were divided into short (<12 cm) and conventional ones, and then, classified according to the classification by Feyen and Shimmin: short stems with neck-retaining osteotomy (group A: 1684 hips), short stems with standard osteotomy (group B: 2727 THAs), and conventional stems (group C: 57,359 cases). Demographics, survivorships, and reasons for revision were investigated and compared. RESULTS: Short stems were preferentially implanted in younger patients and normal morphologies. Short and conventional stems showed comparable survival rates at long-term follow-up (>90% at 15 years). The rates of stem aseptic loosening, intraoperative fractures, and periprosthetic fractures were similar in the 3 groups. Group B had higher rates of revisions due to primary instability (early dislocations and impingement-related events; P < .05). Revisions due to pain were nonsignificantly higher in group B. CONCLUSION: Short stems are reliable implants at long-term follow-up. The comparison with conventional stems showed no additional risk of premature aseptic loosening and intraoperative and periprosthetic fractures. However, the high rate of revisions due to pain and, mostly, primary instability should be investigated in clinical trials.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/estatística & dados numéricos , Desenho de Prótese , Sistema de Registros , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Itália/epidemiologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Osteotomia , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Falha de Prótese , Reoperação/estatística & dados numéricos
17.
J Arthroplasty ; 33(3): 908-914, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29089224

RESUMO

BACKGROUND: Reducing polyethylene (PE) wear by increasing the cross-linking encouraged surgeons to hope for increased total knee arthroplasty (TKA) survival rates. Different methods of manufacturing cross-linked polyethylene (XLPE) were introduced, following promising in vitro results. Is there a measurable effect of cross-linking on TKA survival? METHODS: A registry study was conducted, focusing on fixed tibial inserts in primary TKA. Conventional PE represented 87% of the liners, 10% were cross-linked and 2% were antioxidant PE. Sixty-four percent of the liners were posterior-stabilized (PS). Survival of the different PE groups and survival of the main XLPE available were successively compared. We also looked for differences in the same brand implant groups with regard to PE type, as well as differences between cruciate retaining and PS knees. RESULTS: No differences were found when looking at survival for any cause or for aseptic loosening only (P = .96). When comparing the XLPE available, X3 was found to have a better survival than Prolong or Smith & Nephew XLPE (P = .036). When the same implants and X3 or conventional PE were used, no difference could reach a statistical significance. With Zimmer LPS Flex, Prolong XLPE was even associated with a lower survival compared with conventional PE. On Stryker implants, only the Cox regression model allowed highlighting a difference between X3 XLPE and conventional PE, only in PS knees. CONCLUSION: Increasing the cross-linking seems to only have a low effect, if any, on knee arthroplasty survival. Differences between brands could be found; the manufacturing process could play a role.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Polietileno , Polietilenos , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Antioxidantes/química , Reagentes de Ligações Cruzadas/química , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Falha de Prótese , Sistema de Registros , Adulto Jovem
18.
Materials (Basel) ; 10(7)2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28773095

RESUMO

Recently, concerns have been raised about the potential effect of head-neck junction damage products at the local and systemic levels. Factors that may affect this damage process have not been fully established yet. This study investigated the possible correlations among head-neck junction damage level, implant design, material combination, and patient characteristics. Head-neck junctions of 148 retrieved implants were analysed, including both ceramic-on-ceramic (N = 61) and metal-on-metal (N = 87) bearings. In all cases, the male taper was made of titanium alloy. Damage was evaluated using a four-point scoring system based on damage morphology and extension. Patient age at implantation, implantation time, damage risk factor, and serum ion concentration were considered as independent potential predicting variables. The damage risk factor summarises head-neck design characteristics and junction loading condition. Junction damage correlated with both implantation time and damage factor risk when the head was made of ceramic. A poor correlation was found when the head was made of cobalt alloy. The fretting-corrosion phenomenon seemed mainly mechanically regulated, at least when cobalt alloy components were not involved. When a component was made of cobalt alloy, the role of chemical phenomena increased, likely becoming, over implantation time, the damage driving phenomena of highly stressed junctions.

19.
J Arthroplasty ; 32(11): 3368-3372, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28655567

RESUMO

BACKGROUND: The incidence of total knee replacements (TKRs) in young patients is increasing. Few reports described encouraging results and acceptable survival rates. However, many concerns still persist, in particular about the high rates of infection and aseptic loosening. Aim of this article was to investigate the survival of TKRs in patients aged 45 years or younger in a registry population. METHODS: The Emilia-Romagna registry RIPO was enquired about TKRs in patients ≤45 years; 238 TKRs were evaluated at a mean follow-up of 5.4 years (range 0-15.6 years), examining the features of the patients involved, the survival rate, and the reasons for revision of the knee implants. RESULTS: The TKRs were generally performed in men, in private hospitals, and almost in half of the cases for other causes rather than primary osteoarthritis. The mean age was 40 years. Bicompartmental, cemented posterior-stabilized implants with fixed bearing were preferred. The survival rate was higher than 90% in the first 7 years, and then it decremented. The choice of implant did not apparently influence the survivorship. The final outcomes were acceptable, substantially in line with the previous literature about young patients. Twenty-one revisions occurred (8.8%), in particular 8 cases for aseptic loosening and 7 TKRs for infection. The rate of revision was higher than in overall population and even in some young cohorts. CONCLUSION: TKRs in patients aged 45 years or younger seem a promising procedure, although the high rates of septic and aseptic loosening should be carefully evaluated. Prospective, well-designed studies are required to confirm and investigate these preliminary findings.


Assuntos
Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Reoperação/estatística & dados numéricos , Adolescente , Adulto , Idoso , Feminino , Humanos , Incidência , Estimativa de Kaplan-Meier , Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/mortalidade , Estudos Prospectivos , Falha de Prótese , Sistema de Registros , Taxa de Sobrevida , Sobreviventes , Adulto Jovem
20.
Hip Int ; 27(1): 8-13, 2017 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-27791244

RESUMO

INTRODUCTION: Ceramic-on-ceramic (CoC) couplings are alternative bearings surfaces that have been reported to reduce osteolysis, wear debris and aseptic loosening compared to the use of polyethylene. Early experiences with ceramics had poor results, but they have led to many improvements in the manufacture and design of subsequent implants. METHODS: We analysed medical files of 300 CoC total hip arthroplasty (THA) with a modular neck performed during period 1995-2000 by a single surgeon for a minimum follow-up of 13 years, evaluating clinical and radiological outcome. RESULTS: The mean clinical Merle d'Aubigne and Postel hip score at the final follow-up is 17.4, against a preoperative value of 11.4. Overall survivorship with an endpoint of revision is 93.2% (95% CI, 89.0%-97.3%) at 15 years, while considering only prosthesis failures related to aseptic loosening and ceramic breakage, survival rate at 15 years is 97.2% (95% CI, 94.8%-100%). We observed complications that led to revision surgery in 11 patients (4%) (periprosthetic fractures, liner ruptures, septic loosening of the implant, aseptic loosening of the cup, aseptic loosening of the stem). The occurrence of squeaking is low (1.6%, 4 cases) and we analysed the characteristics of these patients. DISCUSSION: Our study shows an excellent long term survivorship of third generation alumina CoC THA. We reiterate the importance to have a stable implant to maximise the advantage of ceramic and to avoid complications.


Assuntos
Óxido de Alumínio/química , Artroplastia de Quadril/métodos , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Adulto , Fatores Etários , Idoso , Artroplastia de Quadril/efeitos adversos , Estudos de Coortes , Bases de Dados Factuais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Falha de Prótese , Reoperação/métodos , Estudos Retrospectivos , Medição de Risco , Fatores Sexuais , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...