Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Am J Drug Alcohol Abuse ; 49(1): 43-52, 2023 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-36001871

RESUMO

Background: For patients with opioid use disorder, buprenorphine extended-release injection (BUP-XR) achieves sustained therapeutic plasma concentrations, controls craving and withdrawal symptoms, and improves patient outcomes. Given retention challenges during transmucosal buprenorphine (BUP-TM) induction, assessing methods to quickly achieve sustained buprenorphine concentrations is important.Objectives: This open-label, single-group, single-center pilot study (NCT03993392) evaluated safety and tolerability of initiating BUP-XR following a single BUP-TM 4 mg dose.Methods: Eligible participants abstained from short and long-acting opioids for 6 and 24 hours, respectively. If the Clinical Opiate Withdrawal Scale (COWS) was ≥8, BUP-TM 4 mg was administered. Participants not exhibiting hypersensitivity, precipitated opioid withdrawal (POW), or sedation symptoms within 1 hour received BUP-XR 300 mg (assessed as inpatients for 48 hours and outpatients to Day 29). Endpoints were COWS score increase ≥6, independent adjudication of POW, and opioid use.Results: Twenty-six participants (14 male) received BUP-TM, 24 received BUP-XR, and 20 completed the study. After injection, COWS scores decreased from pre-BUP-TM baseline of 14.6 ± 4.1 to 6.9 ± 4.1 at 6 hours and 4.2 ± 3.2 at 24 hours. Most participants (62.5%) experienced maximum COWS scores pre-BUP-XR; 2 experienced a COWS score increase ≥6, occurring at 1 and 2 hours post-BUP-XR. By adjudication, 2/24 participants experienced POW. Irritability, anxiety, nausea, and pain were the most frequent adverse events (AEs) with no serious AEs.Conclusions: Results support increased flexibility for initiating BUP-XR. Initiating BUP-XR 300 mg following a single BUP-TM 4 mg dose was well tolerated. Although some participants initially experienced withdrawal symptoms after injection, significant symptomatic improvement was observed in all participants within 24 hours.


Assuntos
Buprenorfina , Transtornos Relacionados ao Uso de Opioides , Síndrome de Abstinência a Substâncias , Humanos , Masculino , Analgésicos Opioides/uso terapêutico , Buprenorfina/uso terapêutico , Preparações de Ação Retardada/uso terapêutico , Injeções Subcutâneas , Naltrexona/uso terapêutico , Antagonistas de Entorpecentes/uso terapêutico , Transtornos Relacionados ao Uso de Opioides/tratamento farmacológico , Projetos Piloto , Síndrome de Abstinência a Substâncias/tratamento farmacológico
2.
PLoS One ; 17(1): e0256752, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35085249

RESUMO

BACKGROUND: Opioid-induced respiratory depression driven by ligand binding to mu-opioid receptors is a leading cause of opioid-related fatalities. Buprenorphine, a partial agonist, binds with high affinity to mu-opioid receptors but displays partial respiratory depression effects. The authors examined whether sustained buprenorphine plasma concentrations similar to those achieved with some extended-release injections used to treat opioid use disorder could reduce the frequency and magnitude of fentanyl-induced respiratory depression. METHODS: In this two-period crossover, single-centre study, 14 healthy volunteers (single-blind, randomized) and eight opioid-tolerant patients taking daily opioid doses ≥90 mg oral morphine equivalents (open-label) received continuous intravenous buprenorphine or placebo for 360 minutes, targeting buprenorphine plasma concentrations of 0.2 or 0.5 ng/mL in healthy volunteers and 1.0, 2.0 or 5.0 ng/mL in opioid-tolerant patients. Upon reaching target concentrations, participants received up to four escalating intravenous doses of fentanyl. The primary endpoint was change in isohypercapnic minute ventilation (VE). Additionally, occurrence of apnea was recorded. RESULTS: Fentanyl-induced changes in VE were smaller at higher buprenorphine plasma concentrations. In healthy volunteers, at target buprenorphine concentration of 0.5 ng/mL, the first and second fentanyl boluses reduced VE by [LSmean (95% CI)] 26% (13-40%) and 47% (37-59%) compared to 51% (38-64%) and 79% (69-89%) during placebo infusion (p = 0.001 and < .001, respectively). Discontinuations for apnea limited treatment comparisons beyond the second fentanyl injection. In opioid-tolerant patients, fentanyl reduced VE up to 49% (21-76%) during buprenorphine infusion (all concentration groups combined) versus up to 100% (68-132%) during placebo infusion (p = 0.006). In opioid-tolerant patients, the risk of experiencing apnea requiring verbal stimulation following fentanyl boluses was lower with buprenorphine than with placebo (odds ratio: 0.07; 95% CI: 0.0 to 0.3; p = 0.001). INTERPRETATION: Results from this proof-of-principle study provide the first clinical evidence that high sustained plasma concentrations of buprenorphine may protect against respiratory depression induced by potent opioids like fentanyl.


Assuntos
Buprenorfina/administração & dosagem , Fentanila/efeitos adversos , Transtornos Relacionados ao Uso de Opioides/tratamento farmacológico , Insuficiência Respiratória/tratamento farmacológico , Adulto , Buprenorfina/farmacocinética , Estudos Cross-Over , Preparações de Ação Retardada , Feminino , Voluntários Saudáveis , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Transtornos Relacionados ao Uso de Opioides/sangue , Estudo de Prova de Conceito , Insuficiência Respiratória/sangue , Insuficiência Respiratória/induzido quimicamente , Método Simples-Cego , Adulto Jovem
3.
Artigo em Inglês | MEDLINE | ID: mdl-24861875

RESUMO

Two simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) methods (low range and high range) were developed and validated for the quantification of cocaine and its metabolite (-)ecgonine methyl ester (EME) in human acidified stabilized plasma samples. In the low range assay, cocaine and the internal standard, cocaine-D3, were extracted using a single step liquid-liquid extraction from human acidified stabilized plasma. For the high range assay, human acidified stabilized plasma containing cocaine, EME, and the internal standards, cocaine-D3 and EME-D3, was mixed with acetonitrile, and the protein precipitate was separated by centrifugation. Both cocaine and EME extracted from both assays were separated on a HILIC column and detected in positive ion mode using multiple reaction monitoring (MRM). Both methods were validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. The linear range for the low range assay was 0.01-5ng/mL for cocaine; in the high range assay values were 5-1000ng/mL for cocaine and 1-200ng/mL for EME. The correlation coefficient (R(2)) values for both assays were 0.993 or greater. The precision and accuracy for intra-day and inter-day were better than 13.0%. The recovery was above 85% and matrix effects were low with the matrix factor ranging from 0.817 to 1.10 for both analytes in both assays. The validated methods were successfully used to quantify the plasma concentrations of cocaine and EME in clinical pharmacokinetic and pharmacodynamic studies.


Assuntos
Cocaína/análogos & derivados , Cocaína/sangue , Hidrolases de Éster Carboxílico/farmacocinética , Cromatografia Líquida , Cocaína/farmacocinética , Transtornos Relacionados ao Uso de Cocaína/tratamento farmacológico , Feminino , Humanos , Limite de Detecção , Extração Líquido-Líquido , Masculino , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...