Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38864548

RESUMO

BACKGROUND: Diastolic dysfunction and alterations in cardiac geometry are early indicators of diabetic cardiomyopathy. However, the association between cardiac changes across the glucose continuum and the contribution of epicardial adipose tissue (EAT) to these changes has not yet been investigated. PURPOSE: In this study, we aim to investigated the EAT on cardiac diastolic function and structural alterations along the diabetic continuum using cardiac magnetic resonance imaging (CMRI). METHODS: We enrolled individuals who were categorized into groups based on glucose tolerance status. Left ventricular structure and diastolic function were assessed using echocardiography and CMRI to determine the EAT, intramyocardial fat, and associated parameters. Multivariable logistic regression models were also used. RESULTS: In a study of 370 patients (209 normal glucose tolerance, 82 prediabetes, 79 diabetes), those with prediabetes and diabetes showed increased heart dimensions and diastolic dysfunction, including E/E' (the ratio of early mitral inflow velocity to mitral annular early diastolic velocity) (7.9±0.51 vs. 8.5±0.64 vs. 10.0±0.93, p=0.010), left atrial volume index (28.21±14.7 vs. 33.2±12.8 vs. 37.4±8.2 mL/m2, p<0.001), and left ventricular peak filling rate (4.46±1.75 vs. 3.61±1.55 vs. 3.20±1.30 mL/s, p<0.001). EAT significantly increased in prediabetes and diabetes (26.3±1.16 vs. 31.3±1.83 vs. 33.9±1.9 gm, p=0.001), while intramyocardial fat did not differ significantly. Prediabetes altered heart geometry, but not diastolic function (OR 1.22 [1.02-1.83], p=0.012; and 1.70 [0.79-3.68], p=0.135). Diabetes significantly affected both heart structure and diastolic function (OR 1.42 [1.11-1.97], p=0.032; and 2.56 [1.03-5.40], p=0.034) after adjusting for covariates. CONCLUSIONS: Elevated EAT was observed in patients with prediabetes and is associated with adverse alterations in cardiac structure and diastolic function, potentially serving as an underlying mechanism for the early onset of diabetic cardiomyopathy.

2.
Ther Adv Chronic Dis ; 15: 20406223231222828, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38223905

RESUMO

Background: Transthyretin cardiomyopathy (ATTR-CM) is a debilitating disease that has received much attention since the emergence of novel treatments. The Transthyretin Cardiomyopathy Clinical Trial showed that tafamidis, a transthyretin tetramer stabilizer, effectively reduced the declines in functional capacity and quality of life. However, Ala97Ser (A97S) hereditary ATTR-CM is underrepresented in major ATTR-CM tafamidis trials. Objectives: We aim to investigate the change in global longitudinal strain (GLS) of A97S ATTR-CM patients after 12 months of tafamidis treatment. Methods: We retrospectively analysed a prospective cohort of patients with A97S ATTR-CM who received tafamidis meglumine (61 mg/day) at the National Taiwan University Hospital. Echocardiography with speckle tracking strain analysis was performed at baseline and 12 months after treatment. Results: In all, 20 patients were included in the cohort. The baseline left ventricular ejection fraction (LVEF) and interventricular septum (IVS) thickness were 59.20 ± 13.23% and 15.10 ± 3.43 mm, respectively. After 12 months of tafamidis treatment, the LVEF and IVS were 61.83 ± 15.60% (p = 0.244) and 14.59 ± 3.03 mm (p = 0.623), respectively. GLS significantly improved from -12.70 ± 3.31% to -13.72 ± 3.17% (p = 0.048), and longitudinal strain (LS) in apical and middle segments significantly improved from -16.05 ± 4.82% to -17.95 ± 3.48% (p = 0.039) and -11.89 ± 4.38% to -13.58 ± 3.12% (p = 0.039), respectively. Subgroup analysis showed that patients with LVEF < 50% had a better treatment response and improvement in GLS. The patients with an IVS ⩾ 13 mm had an improvement in two-chamber LS from -10.92 ± 4.25% to -13.15 ± 3.87% (p = 0.042) and an improvement in apical left ventricular LS from -15.30 ± 5.35% to -17.82 ± 3.99% (p = 0.031). Conclusion: Tafamidis significantly improved GLS, and particularly apical and middle LS in A97S ATTR-CM patients.


Tafamidis improves myocardial longitudinal strain in A97S transthyretin cardiac amyloidosis Transthyretin cardiomyopathy (ATTR-CM) is a severe heart condition that has gained attention due to recent advancements in treatments. One of these treatments, called tafamidis, has been shown to be effective in maintaining heart function and quality of life. However, there has been limited research on a specific genetic variation of ATTR-CM: A97S. Our aim was to determine whether A97S ATTR-CM patients experienced improved heart function after one year of tafamidis treatment. We conducted this study at the National Taiwan University Hospital, where we enrolled 20 A97S ATTR-CM patients. We used echocardiography to evaluate their heart function, focusing on a parameter called global longitudinal strain. The results showed that after one year of tafamidis treatment, these patients experienced a significant improvement in their global longitudinal strain, particularly in the apical and middle regions of the heart. In conclusion, tafamidis appears to be beneficial for A97S ATTR-CM patients by enhancing their heart's global longitudinal strain, which is a positive sign for their cardiac health.

3.
J Am Heart Assoc ; 13(2): e030512, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38214277

RESUMO

BACKGROUND: Hereditary transthyretin amyloid cardiomyopathy (hATTR-CM) is a progressive and fatal disease. Recent evidence indicates that bone scintigraphy may serve as a tool to monitor the effectiveness of hATTR-CM treatment. The objective of this study was to examine how eplontersen therapy influences the semiquantitative uptake of technetium-99m-pyrophosphate in individuals diagnosed with hATTR-CM. METHODS AND RESULTS: We retrospectively analyzed a prospective cohort from the NEURO-TTRansform trial, including patients with hATTR-CM receiving eplontersen (45 mg/4 weeks). A control group comprised patients with hATTR-CM who had not received eplontersen, inotersen, tafamidis, or patisiran. Technetium-99m-pyrophosphate single-photon emission computed tomography/computed tomography was conducted at baseline and during follow-up. Thirteen patients with hATTR-CM were enrolled, with 6 receiving eplontersen and 7 serving as the control group. The median follow-up time was 544 days. The eplontersen group exhibited a significant decrease in volumetric heart and lung ratio (3.774 to 2.979, P=0.028), whereas the control group showed no significant change (4.079 to 3.915, P=0.237). Patients receiving eplontersen demonstrated a significantly greater reduction in volumetric heart and lung ratio compared with the control group (-20.7% versus -3.4%, P=0.007). CONCLUSIONS: The volumetric heart and lung ratio used to quantify technetium-99m-pyrophosphate uptake showed a significant reduction subsequent to eplontersen treatment in individuals diagnosed with hATTR-CM. These findings suggest the potential efficacy of eplontersen in treating hATTR-CM and highlight the value of technetium-99m-pyrophosphate single-photon emission computed tomography/computed tomography as a tool for monitoring therapeutic effectiveness.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Humanos , Neuropatias Amiloides Familiares/diagnóstico por imagem , Neuropatias Amiloides Familiares/tratamento farmacológico , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/tratamento farmacológico , Pré-Albumina/genética , Pré-Albumina/uso terapêutico , Estudos Prospectivos , Estudos Retrospectivos , Pirofosfato de Tecnécio Tc 99m , Tomografia Computadorizada por Raios X
4.
Orphanet J Rare Dis ; 18(1): 289, 2023 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-37705003

RESUMO

BACKGROUND: Transthyretin cardiac cardiomyopathy (ATTR-CM) is a rare but life-threatening disease. Tafamidis is an effective treatment for patients with ATTR-CM, however its long-term effects on cardiac remodeling and cardiac amyloid deposition are unknown. This study aimed to used cardiac magnetic resonance (CMR) to investigate the effects of tafamidis on patients with hereditary A97S ATTR-CM. METHODS: We retrospectively analyzed a prospective cohort of ATTR-CM patients, including 14 with hereditary A97S ATTR-CM and 17 healthy controls with baseline CMR data. All ATTR-CM patients received tafamidis treatment and received CMR with extracellular volume (ECV) at baseline and after 1 year of follow-up. RESULTS: Baseline N-terminal pro-B-type natriuretic peptide, left ventricular (LV) mass, LV ejection fraction, global radial, circumferential and longitudinal strain, T1 mapping and ECV were significantly worse in the patients with ATTR-CM compared with the healthy controls. After 1 year of tafamidis treatment, ECV decreased from 51.5 ± 8.9% to 49.0 ± 9.4% (P = 0.041), however there were no significant changes in LV mass, LV ejection fraction, global radial strain, global circumferential strain, global longitudinal strain and T1 mapping. CONCLUSIONS: After a one-year treatment period, tafamidis exhibited subtle but statistically significant reductions in ECV, potentially indicating a decrease in amyloid deposition among patients diagnosed with hereditary A97S ATTR-CM.


Assuntos
Amiloidose , Cardiomiopatias , Humanos , Seguimentos , Pré-Albumina/genética , Estudos Prospectivos , Estudos Retrospectivos , Cardiomiopatias/tratamento farmacológico , Cardiomiopatias/genética
5.
J Am Heart Assoc ; 12(17): e027781, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37642018

RESUMO

Background Myocardial steatosis and fibrosis may play a role in the pathophysiology of heart failure with preserved ejection fraction. We therefore investigated the prognostic significance of epicardial fat (epicardial adipose tissue [EAT]) and myocardial diffuse fibrosis. Methods and Results Myocardial fibrosis, estimated as extracellular volume (ECV), and EAT were measured using cardiac magnetic resonance imaging in 163 subjects with heart failure with preserved ejection fraction. We also evaluated cardiac structure and diastolic and systolic function by echocardiography and cardiac magnetic resonance imaging. After 24 months' follow-up, 39 (24%) subjects had experienced cardiovascular events, including hospitalization for heart failure, acute coronary syndrome, and cardiovascular death. Median EAT and mean ECV were significantly higher in subjects with cardiovascular events than survivors (EAT, 35 [25-45] versus 31 [21-38], P=0.006 and ECV, 28.9±3.16% versus 27.2±3.56%, P=0.04). Subjects with high EAT (≥42 g) had increased risk of cardiovascular events (hazard ratio [HR], 2.528 [95% CI, 1.704-4.981]; P=0.032). High ECV (>29%) was also significantly associated with poorer outcomes (HR, 1.647 [95% CI, 1.263-2.548]; P=0.013). With respect to secondary end points, high EAT and high ECV were associated with increased risk of the incident acute coronary syndrome (HR, 1.982 [95% CI, 1.008-4.123]; P=0.049) and hospitalization for heart failure (HR, 1.789 [95% CI, 1.102-6.987]; P=0.033), respectively. Conclusions Our study suggested that increased epicardial fat and ECV detected by cardiac magnetic resonance imaging have an impact on cardiovascular prognosis, in particular acute coronary syndrome and hospitalization for heart failure, respectively.


Assuntos
Síndrome Coronariana Aguda , Insuficiência Cardíaca , Humanos , Síndrome Coronariana Aguda/diagnóstico por imagem , Prognóstico , Volume Sistólico , Insuficiência Cardíaca/diagnóstico por imagem , Imageamento por Ressonância Magnética
6.
Acta Cardiol Sin ; 39(4): 619-627, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37456942

RESUMO

Background: Hereditary transthyretin amyloid cardiomyopathy (ATTR-CM) is a progressive and fatal disease. A97S (p.Ala117Ser) is the most common transthyretin genetic mutation in Taiwan. Tafamidis is a transthyretin stabilizer, and it has been shown to improve outcomes. However, its effect on A97S ATTR-CM subtypes remains unknown. Objectives: This study aimed to investigate the efficacy of tafamidis in patients with hereditary A97S ATTR-CM after 6 months of treatment. Methods: We retrospectively analyzed ATTR-CM patients who received tafamidis (61 mg/day) treatment at National Taiwan University Hospital. Functional status, biochemistry and echocardiography were measured at baseline and after 6 months of tafamidis treatment. The outcome measure was to compare the N-terminal pro-brain natriuretic peptide (NT-proBNP) level at baseline and after 6 months of tafamidis treatment. Results: Twenty patients were enrolled in this study. Their mean age was 63.0 ± 5.8 years and 75% were men. The baseline left ventricular (LV) mass index was 200.9 ± 63.9 g/m2, and the baseline LV ejection fraction was 58.9 ± 13.5%. After 6 months of treatment, the log NT-proBNP level significantly improved from 2.9 ± 0.6 to 2.7 ± 0.5 (p = 0.036). Subgroup analysis showed that the LV posterior wall thickness and left atrial diameter were significantly higher in the patients with improved NT-proBNP, suggesting the benefits of tafamidis for ATTR-CM patients with severe cardiac involvement. Conclusions: The patients with hereditary A97S ATTR-CM in this study had decreased levels of NT-proBNP after 6 months of tafamidis treatment, and this reduction was especially pronounced in those with more severe cardiac involvement.

8.
Korean J Radiol ; 24(4): 349-361, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36907594

RESUMO

OBJECTIVE: To quantitatively assess the pulmonary vasculature using non-contrast computed tomography (CT) in patients with chronic thromboembolic pulmonary hypertension (CTEPH) pre- and post-treatment and correlate CT-based parameters with right heart catheterization (RHC) hemodynamic and clinical parameters. MATERIALS AND METHODS: A total of 30 patients with CTEPH (mean age, 57.9 years; 53% female) who received multimodal treatment, including riociguat for ≥ 16 weeks with or without balloon pulmonary angioplasty and underwent both non-contrast CT for pulmonary vasculature analysis and RHC pre- and post-treatment were included. The radiographic analysis included subpleural perfusion parameters, including blood volume in small vessels with a cross-sectional area ≤ 5 mm² (BV5) and total blood vessel volume (TBV) in the lungs. The RHC parameters included mean pulmonary artery pressure (mPAP), pulmonary vascular resistance (PVR), and cardiac index (CI). Clinical parameters included the World Health Organization (WHO) functional class and 6-minute walking distance (6MWD). RESULTS: The number, area, and density of the subpleural small vessels increased after treatment by 35.7% (P < 0.001), 13.3% (P = 0.028), and 39.3% (P < 0.001), respectively. The blood volume shifted from larger to smaller vessels, as indicated by an 11.3% increase in the BV5/TBV ratio (P = 0.042). The BV5/TBV ratio was negatively correlated with PVR (r = -0.26; P = 0.035) and positively correlated with CI (r = 0.33; P = 0.009). The percent change across treatment in the BV5/TBV ratio correlated with the percent change in mPAP (r = -0.56; P = 0.001), PVR (r = -0.64; P < 0.001), and CI (r = 0.28; P = 0.049). Furthermore, the BV5/TBV ratio was inversely associated with the WHO functional classes I-IV (P = 0.004) and positively associated with 6MWD (P = 0.013). CONCLUSION: Non-contrast CT measures could quantitatively assess changes in the pulmonary vasculature in response to treatment and were correlated with hemodynamic and clinical parameters.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/terapia , Hipertensão Pulmonar/complicações , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Pulmão , Tomografia Computadorizada por Raios X/métodos , Hemodinâmica , Angioplastia com Balão/métodos , Doença Crônica , Artéria Pulmonar
9.
ESC Heart Fail ; 9(6): 4335-4339, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36128649

RESUMO

Transthyretin cardiomyopathy (ATTR-CM) is an under-recognized cause of heart failure, but it has received increasing attention due to the availability of treatment options. We present a case of hereditary transthyretin cardiomyopathy (A97S, an under-represented variant in current clinical studies) who presented with heart failure. Timely diagnosis and intervention with tafamidis demonstrated reversed cardiac remodelling via multiple imaging techniques (echocardiography, cardiac magnetic resonance imaging and technetium-99m pyrophosphate scintigraphy). The echocardiography and cardiac magnetic resonance imaging demonstrated improved global strain. Cardiac magnetic resonance imaging showed decreased extracellular volume. The technetium-99m pyrophosphate scintigraphy demonstrated decreased heart-to-contralateral ratio. This case highlights the potential reversible effect of tafamidis on A97S amyloidosis cardiomyopathy.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Insuficiência Cardíaca , Humanos , Difosfatos/uso terapêutico , Tecnécio/uso terapêutico , Pré-Albumina , Remodelação Ventricular , Neuropatias Amiloides Familiares/complicações , Neuropatias Amiloides Familiares/diagnóstico , Neuropatias Amiloides Familiares/tratamento farmacológico , Cardiomiopatias/diagnóstico , Cardiomiopatias/tratamento farmacológico , Cardiomiopatias/etiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/etiologia
10.
Front Cardiovasc Med ; 9: 961920, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36017096

RESUMO

Background: Acute ST-elevation myocardial infarction (STEMI) elicits a robust cardiomyocyte death and inflammatory responses despite timely revascularization. Objectives: This phase 1, open-label, single-arm, first-in-human study aimed to assess the safety and efficacy of combined intracoronary (IC) and intravenous (IV) transplantation of umbilical cord-derived mesenchymal stem cells (UMSC01) for heart repair in STEMI patients with impaired left ventricular ejection fraction (LVEF 30-49%) following successful reperfusion by percutaneous coronary intervention. Methods: Consenting patients received the first dose of UMSC01 through IC injection 4-5 days after STEMI followed by the second dose of UMSC01 via IV infusion 2 days later. The primary endpoint was occurrence of any treatment-related adverse events and the secondary endpoint was changes of serum biomarkers and heart function by cardiac magnetic resonance imaging during a 12-month follow-up period. Results: Eight patients gave informed consents, of whom six completed the study. None of the subjects experienced treatment-related serious adverse events or major adverse cardiovascular events during IC or IV infusion of UMSC01 and during the follow-up period. The NT-proBNP level decreased (1362 ± 1801 vs. 109 ± 115 pg/mL, p = 0.0313), the LVEF increased (52.67 ± 12.75% vs. 62.47 ± 17.35%, p = 0.0246), and the wall motion score decreased (26.33 ± 5.57 vs. 22.33 ± 5.85, p = 0.0180) at the 12-month follow-up compared to the baseline values. The serial changes of LVEF were 0.67 ± 3.98, 8.09 ± 6.18, 9.04 ± 10.91, and 9.80 ± 7.56 at 1, 3, 6, and 12 months, respectively as compared to the baseline. Conclusion: This pilot study shows that combined IC and IV transplantation of UMSC01 in STEMI patients with impaired LVEF appears to be safe, feasible, and potentially beneficial in improving heart function. Further phase 2 studies are required to explore the effectiveness of dual-route transplantation of UMSC01 in STEMI patients.

11.
Ann Clin Transl Neurol ; 9(9): 1359-1369, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35945697

RESUMO

OBJECTIVE: Late-onset hereditary transthyretin amyloidosis with polyneuropathy (ATTRv-PN) is often associated with heart involvement. Recent advances in cardiac imaging allow the detection of cardiac amyloidosis. This study aimed to explore cardiomyopathy by cardiac imaging and its clinical correlates with polyneuropathy in late-onset ATTRv-PN. METHODS: Polyneuropathy was assessed by intraepidermal nerve fiber (IENF) density, nerve conduction study (NCS), autonomic function tests, quantitative sensory testing, and clinical questionnaires. Cardiomyopathy was evaluated by echocardiography, 99m Tc-pyrophosphate (PYP) single-photon emission computed tomography (SPECT) imaging, cardiac magnetic resonance imaging (CMR), and serum Pro-B-type natriuretic peptide. Healthy controls and patients with Brugada syndrome were enrolled for comparison of CMR. RESULTS: Fifty late-onset ATTRv-PN patients (38 men, 46 with p. A117S mutation), aged 63.7 ± 5.5 years, of polyneuropathy disability stage 1-4 were enrolled. All patients presented polyneuropathy in NCS, and 74.5% of patients had reduced IENF density in distal legs. All patients showed significant radiotracer uptake in the heart on 99m Tc-PYP SPECT imaging, and 87.8% of patients had abnormally increased left ventricular (LV) septum thickness on echocardiography. CMR showed longer myocardial native T1, larger extracellular volume, greater LV mass index, and higher LV mass to end-diastolic volume ratio in ATTRv-PN patients than healthy controls and patients with Brugada syndrome. These CMR parameters were associated with skin denervation, absent sympathetic skin responses, elevated thermal thresholds, worsened NCS profiles, and functional deficits of polyneuropathy. INTERPRETATION: Late-onset ATTRv-PN coexisted with cardiomyopathy regardless of the clinical severity of polyneuropathy. The cardiac amyloid burden revealed by CMR was correlated with pathophysiology and clinical disability of nerve degeneration.


Assuntos
Neuropatias Amiloides , Síndrome de Brugada , Cardiomiopatias , Polineuropatias , Idoso , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polineuropatias/diagnóstico por imagem , Pré-Albumina
12.
Sci Rep ; 11(1): 10360, 2021 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-33990651

RESUMO

We report the first Asian series on stereotactic body radiation (SBRT) for refractory ventricular arrhythmia (VA) in Taiwanese patients. Three-dimensional electroanatomic maps, delayed-enhancement magnetic resonance imaging (DE-MRI), and dual-energy computed tomography (CT) were used to identify scar substrates. The main target volume was treated with a single radiation dose of 25 Gy and the margin volume received 20 Gy using simultaneous integrated boost delivered by the Varian TrueBeam system. Efficacy was assessed according to VA events recorded by an implantable cardioverter-defibrillator (ICD) or a 24-h Holter recorder. Pre- and post-radiation therapy imaging studies were performed. From February 2019 to December 2019, seven patients (six men, one woman; mean age, 55 years) were enrolled and treated. One patient died of hepatic failure. In the remaining six patients, at a median follow-up of 14.5 months, the VA burden and ICD shocks significantly decreased (only one patient with one ICD shock after treatment). Increased intensity on DE-MRI might be associated with a lower risk for VA recurrence, whereas dual-energy CT had lower detection sensitivity. No acute or minimal late adverse events occurred. In patients with refractory VA, SBRT is associated with a marked reduction in VA burden and ICD shocks, and DE-MRI might be useful for monitoring treatment effects.


Assuntos
Arritmias Cardíacas/terapia , Cicatriz/cirurgia , Desfibriladores Implantáveis/estatística & dados numéricos , Coração/diagnóstico por imagem , Radiocirurgia/estatística & dados numéricos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/patologia , Cicatriz/diagnóstico , Cicatriz/patologia , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Radiocirurgia/efeitos adversos , Taiwan , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
14.
MAGMA ; 34(3): 399-409, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32902778

RESUMO

OBJECTIVE: This study investigated ultrashort echo time (UTE) sequences in 1.5 T magnetic resonance imaging (MRI) for small lung nodule detection. MATERIALS AND METHODS: A total of 120 patients with 165 small lung nodules before video-associated thoracoscopic resection were enrolled. MRI sequences included conventional volumetric interpolated breath-hold examination (VIBE, scan time 16 s), spiral UTE (TE 0.05 ms) with free-breathing (scan time 3.5-5 min), and breath-hold sequences (scan time 20 s). Chest CT provided a standard reference for nodule size and morphology. Nodule detection sensitivity was evaluated on a lobe-by-lobe basis. RESULTS: The nodule detection rate was significantly higher in spiral UTE free-breathing (> 78%, p < 0.05) and breath-hold sequences (> 75%, p < 0.05) compared with conventional VIBE (> 55%), reaching 100% when nodule size was > 16 mm, and reaching 95% when nodules were in solid morphology, regardless of size. The inter-sequence reliability between free-breathing and breath-hold spiral UTE was good (κ > 0.80). Inter-reader agreement was also high (κ > 0.77) for spiral UTE sequences. Nodule size measurements were consistent between CT and spiral UTE MRI, with a minimal bias up to 0.2 mm. DISCUSSION: Spiral UTE sequences detect small lung nodules that warrant surgery, offers realistic scan times for clinical work, and could be implemented as part of routine lung MRI.


Assuntos
Imageamento por Ressonância Magnética , Suspensão da Respiração , Humanos , Pulmão , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
15.
Diagnostics (Basel) ; 12(1)2021 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-35054260

RESUMO

This prospective study aimed to investigate the ability of spiral ultrashort echo time (UTE) and compressed sensing volumetric interpolated breath-hold examination (CS-VIBE) sequences in magnetic resonance imaging (MRI) compared to conventional VIBE and chest computed tomography (CT) in terms of image quality and small nodule detection. Patients with small lung nodules scheduled for video-assisted thoracoscopic surgery (VATS) for lung wedge resection were prospectively enrolled. Each patient underwent non-contrast chest CT and non-contrast MRI on the same day prior to thoracic surgery. The chest CT was performed to obtain a standard reference for nodule size, location, and morphology. The chest MRI included breath-hold conventional VIBE and CS-VIBE with scanning durations of 11 and 13 s, respectively, and free-breathing spiral UTE for 3.5-5 min. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and normal structure visualizations were measured to evaluate MRI quality. Nodule detection sensitivity was evaluated on a lobe-by-lobe basis. Inter-reader and inter-modality reliability analyses were performed using the Cohen κ statistic and the nodule size comparison was performed using Bland-Altman plots. Among 96 pulmonary nodules requiring surgery, the average nodule diameter was 7.7 ± 3.9 mm (range: 4-20 mm); of the 73 resected nodules, most were invasive cancer (74%) or pre-invasive carcinoma in situ (15%). Both spiral UTE and CS-VIBE images achieved significantly higher overall image quality scores, SNRs, and CNRs than conventional VIBE. Spiral UTE (81%) and CS-VIBE (83%) achieved a higher lung nodule detection rate than conventional VIBE (53%). Specifically, the nodule detection rate for spiral UTE and CS-VIBE reached 95% and 100% for nodules >8 and >10 mm, respectively. A 90% detection rate was achieved for nodules of all sizes with a part-solid or solid morphology. Spiral UTE and CS-VIBE under-estimated the nodule size by 0.2 ± 1.4 mm with 95% limits of agreement from -2.6 to 2.9 mm and by 0.2 ± 1.7 mm with 95% limits of agreement from -3.3 to 3.5 mm, respectively, compared to the reference CT. In conclusion, chest CT remains the gold standard for lung nodule detection due to its high image resolutions. Both spiral UTE and CS-VIBE MRI could detect small lung nodules requiring surgery and could be considered a potential alternative to chest CT; however, their clinical application requires further investigation.

16.
JACC Cardiovasc Imaging ; 14(2): 335-345, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33221213

RESUMO

OBJECTIVES: The aim of this study was to develop an artificial intelligence tool to assess echocardiographic image quality objectively. BACKGROUND: Left ventricular global longitudinal strain (LVGLS) has recently been used to monitor cancer therapeutics-related cardiac dysfunction (CTRCD) but image quality limits its reliability. METHODS: A DenseNet-121 convolutional neural network was developed for view identification from an athlete's echocardiographic dataset. To prove the concept that classification confidence (CC) can serve as a quality marker, values of longitudinal strain derived from feature tracking of cardiac magnetic resonance (CMR) imaging and strain analysis of echocardiography were compared. The CC was then applied to patients with breast cancer free from CTRCD to investigate the effects of image quality on the reliability of strain analysis. RESULTS: CC of the apical 4-chamber view (A4C) was significantly correlated with the endocardial border delineation index. CC of A4C >900 significantly predicted a <15% relative difference in longitudinal strain between CMR feature tracking and automated echocardiographic analysis. Echocardiographic studies (n =752) of 102 patients with breast cancer without CTRCD were investigated. The strain analysis showed higher parallel forms, inter-rater, and test-retest reliabilities in patients with CC of A4C >900. During sequential comparisons of automated LVGLS in individual patients, those with CC of A4C >900 had a lower false positive detection rate of CTRCD. CONCLUSIONS: CC of A4C was associated with the reliability of automated LVGLS and could also potentially be used as a filter to select comparable images from sequential echocardiographic studies in individual patients and reduce the false positive detection rate of CTRCD.


Assuntos
Inteligência Artificial , Humanos , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Volume Sistólico , Função Ventricular Esquerda
17.
Sci Rep ; 10(1): 20965, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33262487

RESUMO

This study was designed to identify whether the position and size of the region of interest (ROI) influence extracellular volume fraction (ECV) measurements. Patients with localized (n = 203) or infiltrative (n = 215) cardiomyopathies and 36 normal controls were enrolled in this study. ECV measurements at 4 different regions, including the anterior, septal, posterior and lateral wall regions, were measured, and all groups were compared. Regional ECV was correlated with the corresponding regional wall thickness. The diagnostic power to differentiate the myocardial abnormalities was evaluated for each myocardial region. ECVs measured using five different ROI sizes within each myocardial region were compared. Our results showed that ECVs varied among the myocardial regions, and this variation was significantly associated with regional wall thicknesses. For the detection of myocardial abnormalities, regional ECV revealed similar results as ECV derived from the whole region except for the anterior region. No significant difference was found in the ECVs measured using the five different ROI sizes. In conclusion, CMR-derived ECVs vary with myocardial region, and this variation is significantly associated with the regional wall thickness. In contrast, the measured size of the ROI has less of an effect on the ECV.


Assuntos
Espaço Extracelular/metabolismo , Imageamento por Ressonância Magnética , Miocárdio/citologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Reprodutibilidade dos Testes , Adulto Jovem
18.
Artigo em Inglês | MEDLINE | ID: mdl-33221870

RESUMO

AIMS: Hypertrophic cardiomyopathy (HCM) is an inheritable disease that leads to sudden cardiac death and heart failure (HF). Sarcomere mutations (SMs) have been associated with HF. However, the differences in ventricular function between SM-positive and SM-negative HCM patients are poorly characterized. METHODS AND RESULTS: Of the prospectively enrolled 374 unrelated HCM patients in Taiwan, 115 patients underwent both 91 cardiomyopathy-related gene screening and cardiovascular magnetic resonance (45.6 ± 10.6 years old, 76.5% were male). Forty pathogenic/likely pathogenic mutations were identified in 52 patients by next-generation sequencing. The SM-positive group were younger at first cardiovascular event (P = 0.04) and progression to diastolic HF (P = 0.02) with higher N-terminal pro-brain natriuretic peptide (NT-proBNP) [New York Heart Association (NYHA) Class III/IV symptoms with left ventricular ejection fraction > 55%] than the SM-negative group (P < 0.001). SM-positive patients had a greater extent of late gadolinium enhancement (P = 0.01), larger left atrial diameter (P = 0.03), higher normalized peak filling rate (PFR) and PFR ratio, and a greater reduction in global longitudinal strain than SM-negative patients (all P ≤ 0.01). During mean lifelong follow-up time (49.2 ± 15.6 years), SM-positive was a predictor of earlier HF (NYHA Class III/IV symptoms) after multivariate adjustment (hazard ratio 3.5; 95% confidence interval 1.3-9.7; P = 0.015). CONCLUSION: SM-positive HCM patients had a higher extent of myocardial fibrosis and more severe ventricular diastolic dysfunction than those without, which may contribute to earlier onset of advanced HF, suggesting the importance of close surveillance and early treatment throughout life.

19.
J Cardiovasc Magn Reson ; 22(1): 77, 2020 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-33250055

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR)-derived extracellular volume (ECV) requires a hematocrit (Hct) to correct contrast volume distributions in blood. However, the timely assessment of Hct can be challenging and has limited the routine clinical application of ECV. The goal of the present study was to evaluate whether ECV measurements lead to significant error if a venous Hct was unavailable on the day of CMR. METHODS: 109 patients with CMR T1 mapping and two venous Hcts (Hct0: a Hct from the day of CMR, and Hct1: a Hct from a different day) were retrospectively identified. A synthetic Hct (Hctsyn) derived from native blood T1 was also assessed. The study used two different ECV methods, (1) a conventional method in which ECV was estimated from native and postcontrast T1 maps using a region-based method, and (2) an inline method in which ECV was directly measured from inline ECV mapping. ECVs measured with Hct0, Hct1, and Hctsyn were compared for each method, and the reference ECV (ECV0) was defined using the Hct0. The error between synthetic (ECVsyn) and ECV0was analyzed for the two ECV methods. RESULTS: ECV measured using Hct1 and Hctsyn were significantly correlated with ECV0 for each method. No significant differences were observed between ECV0 and ECV measured with Hct1 (ECV1; 28.4 ± 6.6% vs. 28.3 ± 6.1%, p = 0.789) and between ECV0 and ECV calculated with Hctsyn (ECVsyn; 28.4 ± 6.6% vs. 28.2 ± 6.2%, p = 0.45) using the conventional method. Similarly, ECV0 was not significantly different from ECV1 (28.5 ± 6.7% vs. 28.5 ± 6.2, p = 0.801) and ECVsyn (28.5 ± 6.7% vs. 28.4 ± 6.0, p = 0.974) using inline method. ECVsyn values revealed relatively large discrepancies in patients with lower Hcts compared with those with higher Hcts. CONCLUSIONS: Venous Hcts measured on a different day from that of the CMR examination can still be used to measure ECV. ECVsyn can provide an alternative method to quantify ECV without needing a blood sample, but significant ECV errors occur in patients with severe anemia.


Assuntos
Meios de Contraste/metabolismo , Cardiopatias/diagnóstico por imagem , Hematócrito , Imageamento por Ressonância Magnética , Meglumina/sangue , Miocárdio/patologia , Compostos Organometálicos/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Feminino , Fibrose , Cardiopatias/sangue , Cardiopatias/patologia , Humanos , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Adulto Jovem
20.
PLoS One ; 15(8): e0237193, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32780780

RESUMO

BACKGROUND: The myocardial adaptive mechanism in patients with repaired tetralogy of Fallot (rTOF) is less understood. We aimed to investigate biventricular myocardial adaptive remodeling in rTOF patients. METHODS: We recruited 32 rTOF patients and 38 age- and sex-matched normal controls. The pulmonary stenosis of rTOF patients was measured using catheterized pressure gradient between right ventricle (RV) and pulmonary artery (PGRVPA). rTOF patients with PGRVPA < 15 mmHg and ≥15 mmHg were classified as low pulmonary stenosis (rTOFlow, n = 19) and high pulmonary stenosis (rTOFhigh, n = 13) subgroups, respectively. Magnetic resonance imaging tissue phase mapping was employed to evaluate the voxelwise biventricular myocardial motion in longitudinal (Vz), radial (Vr), and circumferential (Vφ) directions. RESULTS: The rTOFlow subgroup presented higher pulmonary regurgitation fraction than rTOFhigh subgroup (p < 0.001). Compared with the normal group, only rTOFlow subgroup presented a decreased RV ejection fraction (RVEF) (p < 0.05). The rTOFlow subgroup showed decreased systolic and diastolic Vz in RV and LV, whereas rTOFhigh subgroup showed such change only in RV. In rTOFlow subgroup, RVEF significantly correlated with RV systolic Vr (r = 0.56, p < 0.05), whereas LVEF correlated with LV systolic Vz (r = 0.51, p = 0.02). Prolonged QRS correlated with RV systolic Vr (r = -0.58, p < 0.01) and LV diastolic Vr (r = 0.81, p < 0.001). No such correlations occurred in rTOFhigh subgroup. CONCLUSIONS: The avoidance of unfavorable functional interaction in RV and LV in rTOFhigh subgroup suggested that adequate pulmonary stenosis (PGRVPA ≥ 15 mmHg in this sereis) has a protective effect against pulmonary regurgitation.


Assuntos
Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/diagnóstico por imagem , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/reabilitação , Adulto , Pressão Sanguínea , Estudos de Casos e Controles , Teste de Esforço , Feminino , Frequência Cardíaca , Humanos , Masculino , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/fisiopatologia , Volume Sistólico , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Esquerda , Função Ventricular Direita , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...