RESUMO
Chest CT provides a way to quantify pulmonary airway and vascular tree measurements. In patients with COPD, CT airway measurement differences in females are concomitant with worse quality-of-life and other outcomes. CT total airway count (TAC), airway lumen area (LA), and wall thickness (WT) also differ in females with long-COVID. Our objective was to evaluate CT airway and pulmonary vascular and quality-of-life measurements in females with COPD as compared to ex-smokers and patients with long-COVID. Chest CT was acquired 3-months post-COVID-19 infection in females with long-COVID for comparison with the same inspiratory CT in female ex-smokers and COPD patients. TAC, LA, WT, and pulmonary vascular measurements were quantified. Linear regression models were adjusted for confounders including age, height, body-mass-index, lung volume, pack-years and asthma diagnosis. Twenty-one females (53 ± 14 years) with long-COVID, 17 female ex-smokers (69 ± 9 years) and 13 female COPD (67 ± 6 years) patients were evaluated. In the absence of differences in quality-of-life scores, females with long-COVID reported significantly different LA (p = 0.006) compared to ex-smokers but not COPD (p = 0.7); WT% was also different compared to COPD (p = 0.009) but not ex-smokers (p = 0.5). In addition, there was significantly greater pulmonary small vessel volume (BV5) in long-COVID as compared to female ex-smokers (p = 0.045) and COPD (p = 0.003) patients and different large (BV10) vessel volume as compared to COPD (p = 0.03). In females with long-COVID and highly abnormal quality-of-life scores, there was CT evidence of airway remodelling, similar to ex-smokers and patients with COPD, but there was no evidence of pulmonary vascular remodelling.Clinical Trial Registration: www.clinicaltrials.gov NCT05014516 and NCT02279329.
Assuntos
Doença Pulmonar Obstrutiva Crônica , Qualidade de Vida , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Ex-Fumantes , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Síndrome de COVID-19 Pós-Aguda/diagnóstico por imagem , Síndrome de COVID-19 Pós-Aguda/fisiopatologia , Estudos Longitudinais , Estudos ProspectivosAssuntos
Muco , Humanos , Muco/metabolismo , Idoso , Masculino , Feminino , Doença Crônica , Idoso de 80 Anos ou maisRESUMO
RATIONALE AND OBJECTIVES: It remains difficult to predict longitudinal outcomes in long-COVID, even with chest CT and functional MRI. 129Xe MRI reflects airway dysfunction, measured using ventilation defect percent (VDP) and in long-COVID patients, MRI VDP was abnormal, suggestive of airways disease. While MRI VDP and quality-of-life improved 15-month post-COVID infection, both remained abnormal. To better understand the relationship of airways disease and quality-of-life improvements in patients with long-COVID, we extracted 129Xe ventilation MRI textures and generated machine-learning models in an effort to predict improved quality-of-life, 15-month post-infection. MATERIALS AND METHODS: Long-COVID patients provided written-informed consent to 3-month and 15-month post-infection visits. Pyradiomics was used to extract 129Xe ventilation MRI texture features, which were ranked using a Random-Forest classifier. Top-ranking features were used in classification models to dichotomize patients based on St. George's Respiratory Questionnaire (SGRQ) score improvement greater than the minimal-clinically-important-difference (MCID). Classification performance was evaluated using the area under the receiver-operator-characteristic-curve (AUC), sensitivity, and specificity. RESULTS: 120 texture features were extracted from 129Xe ventilation MRI in 44 long-COVID participants (54 ± 14 years), including 30 (52 ± 12 years) with ΔSGRQ≥MCID and 14 (58 ± 18 years) with ΔSGRQAssuntos
COVID-19
, Imageamento por Ressonância Magnética
, Qualidade de Vida
, Isótopos de Xenônio
, Humanos
, COVID-19/diagnóstico por imagem
, COVID-19/complicações
, Imageamento por Ressonância Magnética/métodos
, Masculino
, Feminino
, Pessoa de Meia-Idade
, Idoso
, Aprendizado de Máquina
, Estudos Longitudinais
, SARS-CoV-2
, Pulmão/diagnóstico por imagem
RESUMO
Airway mucus is a hydrogel with unique biophysical properties due to its primary water composition and a small proportion of large anionic glycoproteins or mucins. The predominant mucins in human mucus, MUC5AC and MUC5B, are secreted by specialized cells within the airway epithelium both in normal conditions and in response to various stimuli. Their relative proportions are correlated with specific inflammatory responses and disease mechanisms. The dysregulation of mucin expression is implicated in numerous respiratory diseases, including asthma, COPD, and cystic fibrosis, where the pathogenic role of mucus has been extensively described yet often overlooked. In airway diseases, excessive mucus production or impaired mucus clearance leads to mucus plugging, with secondary airway occlusion that contribute to airflow obstruction, asthma severity and poor control. Eosinophils and Charcot Leyden crystals in sputum contribute to the mucus burden and tenacity. Mucin may also contribute to eosinophil survival. Other mechanisms, including eosinophil-independent IL-13 release, mast-cell activation and non-type-2 (T2) cytokines, are also likely to participate in mucus pathobiology. An accurate assessment of mucus and its clinical and functional consequences require a thorough approach that includes evaluation of cellular predominance in sputum, airway cytokines and other inflammatory markers, mucus characteristics and composition and structural and functional impact measured by advanced lung imaging. This review, illustrated with clinical scenarios, provides an overview of current methods to assess mucus and its relevance to the choice of biologics to treat patients with severe asthma.
Assuntos
Asma , Produtos Biológicos , Eosinófilos , Muco , Humanos , Asma/tratamento farmacológico , Asma/metabolismo , Asma/imunologia , Asma/diagnóstico , Eosinófilos/imunologia , Eosinófilos/metabolismo , Produtos Biológicos/uso terapêutico , Produtos Biológicos/farmacologia , Muco/metabolismo , Índice de Gravidade de Doença , Escarro , Mucinas/metabolismoAssuntos
Asma , Neutrófilos , Infecções Respiratórias , Humanos , Asma/tratamento farmacológico , Asma/imunologia , Feminino , Masculino , Neutrófilos/imunologia , Neutrófilos/metabolismo , Infecções Respiratórias/imunologia , Fosfatidilinositol 3-Quinases/metabolismo , Pessoa de Meia-Idade , Recidiva , Adulto , Eosinófilos/imunologia , Progressão da Doença , Índice de Gravidade de DoençaRESUMO
RATIONALE AND OBJECTIVES: Emergent evidence in several respiratory diseases supports translational potential for Phase-Resolved Functional Lung (PREFUL) MRI to spatially quantify ventilation but its feasibility and physiological relevance have not been demonstrated in patients with asthma. This study compares PREFUL-derived ventilation defect percent (VDP) in severe asthma patients to healthy controls and measures its responsiveness to bronchodilator therapy and relation to established measures of airways disease. MATERIALS AND METHODS: Forty-one adults with severe asthma and seven healthy controls performed same-day free-breathing 1H MRI, 129Xe MRI, spirometry, and oscillometry. A subset of participants (n = 23) performed chest CT and another subset of participants with asthma (n = 19) repeated 1H MRI following the administration of a bronchodilator. VDP was calculated for both PREFUL and 129Xe MRI. Additionally, the percent of functional small airways disease was determined from CT parametric response maps (PRMfSAD). RESULTS: PREFUL VDP measured pre-bronchodilator (19.1% [7.4-43.3], p = 0.0002) and post-bronchodilator (16.9% [6.1-38.4], p = 0.0007) were significantly greater than that of healthy controls (7.5% [3.7-15.5]) and was significantly decreased post-bronchodilator (from 21.9% [10.1-36.9] to 16.9% [6.1-38.4], p = 0.0053). PREFUL VDP was correlated with spirometry (FEV1%pred: r = -0.46, p = 0.0023; FVC%pred: r = -0.35, p = 0.024, FEV1/FVC: r = -0.46, p = 0.0028), 129Xe MRI VDP (r = 0.39, p = 0.013), and metrics of small airway disease (CT PRMfSAD: r = 0.55, p = 0.021; Xrs5 Hz: r = -0.44, p = 0.0046, and AX: r = 0.32, p = 0.044). CONCLUSION: PREFUL-derived VDP is responsive to bronchodilator therapy in asthma and is associated with measures of airflow obstruction and small airway dysfunction. These findings validate PREFUL VDP as a physiologically relevant and accessible ventilation imaging outcome measure in asthma.
Assuntos
Asma , Estudos de Viabilidade , Imageamento por Ressonância Magnética , Humanos , Asma/diagnóstico por imagem , Asma/fisiopatologia , Asma/tratamento farmacológico , Masculino , Feminino , Adulto , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Espirometria , Broncodilatadores/uso terapêutico , Testes de Função Respiratória , Estudos de Casos e Controles , Isótopos de Xenônio , Tomografia Computadorizada por Raios XRESUMO
Although hyperpolarized (HP) 129Xe ventilation MRI can be carried out within a breath hold, it is still challenging for many sick patients. Compressed sensing (CS) is a viable alternative to accelerate this approach. However, undersampled images with identical sampling ratios differ from one another. Twenty subjects (n = 10 healthy and n = 10 patients with asthma) were scanned using a GE MR750 3 T scanner, acquiring fully sampled 2D multi-slice HP 129Xe lung ventilation images (10 s breath hold, 128 × 80 (FE × PE-frequency encoding × phase encoding) and 16 slices). Using fully sampled data, 500 variable-density Cartesian random undersampling patterns were generated, each at eight different sampling ratios from 10% to 80%. The parallel imaging and compressed sensing (PICS) command from BART was employed to reconstruct undersampled data. The signal to noise ratio (SNR), structural similarity index measurement (SSIM) and sidelobe to peak ratio of each were subsequently compared. There was a high degree of variation in both SNR and SSIM results from each of the 500 masks of each sampling rate. As the undersampling increases, there is more variation in the quantifying metrics, for both healthy and asthmatic individuals. Our study shows that random undersampling poses a significant challenge when applied at sampling ratios less than 60%, despite fulfilling CS's incoherency criteria. Such low sampling ratios will result in a large variety of undersampling patterns. Therefore, skipped segments of k-space cannot be allowed to happen randomly at low sampling rates. By optimizing the sampling pattern, CS will reach its full potential and be able to be applied to a highly undersampled 129Xe lung dataset.
Assuntos
Pulmão , Imageamento por Ressonância Magnética , Razão Sinal-Ruído , Isótopos de Xenônio , Humanos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Masculino , Feminino , Adulto , Asma/diagnóstico por imagem , Pessoa de Meia-Idade , Compressão de DadosRESUMO
The respiratory consequences of acute COVID-19 infection and related symptoms tend to resolve 4 weeks post-infection. However, for some patients, new, recurrent, or persisting symptoms remain beyond the acute phase and persist for months, post-infection. The symptoms that remain have been referred to as long-COVID. A number of research sites employed 129 Xe magnetic resonance imaging (MRI) during the pandemic and evaluated patients post-infection, months after hospitalization or home-based care as a way to better understand the consequences of infection on 129 Xe MR gas-exchange and ventilation imaging. A systematic review and comprehensive search were employed using MEDLINE via PubMed (April 2023) using the National Library of Medicine's Medical Subject Headings and key words: post-COVID-19, MRI, 129 Xe, long-COVID, COVID pneumonia, and post-acute COVID-19 syndrome. Fifteen peer-reviewed manuscripts were identified including four editorials, a single letter to the editor, one review article, and nine original research manuscripts (2020-2023). MRI and MR spectroscopy results are summarized from these prospective, controlled studies, which involved small sample sizes ranging from 9 to 76 participants. Key findings included: 1) 129 Xe MRI gas-exchange and ventilation abnormalities, 3 months post-COVID-19 infection, and 2) a combination of MRI gas-exchange and ventilation abnormalities alongside persistent symptoms in patients hospitalized and not hospitalized for COVID-19, 1-year post-infection. The persistence of respiratory symptoms and 129 Xe MRI abnormalities in the context of normal or nearly normal pulmonary function test results and chest computed tomography (CT) was consistent. Longitudinal improvements were observed in long-term follow-up of long-COVID patients but mean 129 Xe gas-exchange, ventilation heterogeneity values and symptoms remained abnormal, 1-year post-infection. Pulmonary functional MRI using inhaled hyperpolarized 129 Xe gas has played a role in detecting gas-exchange and ventilation abnormalities providing complementary information that may help develop our understanding of the root causes of long-COVID. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 5.
Assuntos
COVID-19 , Síndrome de COVID-19 Pós-Aguda , Humanos , Isótopos de Xenônio , Estudos Prospectivos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodosAssuntos
Antiasmáticos , Asma , Eosinofilia , Eosinofilia Pulmonar , Humanos , Antiasmáticos/uso terapêutico , Asma/complicações , Asma/tratamento farmacológico , Método Duplo-Cego , Eosinofilia/tratamento farmacológico , Eosinófilos , Eosinofilia Pulmonar/tratamento farmacológico , Método Simples-Cego , Escarro/efeitos dos fármacos , Escarro/metabolismo , Interleucina-5/imunologia , Interleucina-5/uso terapêutico , Anticorpos/uso terapêuticoAssuntos
COVID-19 , Humanos , Pandemias , Tórax , SARS-CoV-2 , Tomografia Computadorizada por Raios XRESUMO
Introduction: The ideal contrast agents for ventilation SPECT and MRI are Technegas and 129Xe gas, respectively. Despite increasing interest in the clinical utility of ventilation imaging, these modalities have not been directly compared. Therefore, our objective was to compare the ventilation defect percent (VDP) assessed by Technegas SPECT and hyperpolarized 129Xe MRI in patients scheduled to undergo lung cancer resection with and without pre-existing obstructive lung disease. Methods: Forty-one adults scheduled to undergo lung cancer resection performed same-day Technegas SPECT, hyperpolarized 129Xe MRI, spirometry, and diffusing capacity of the lung for carbon monoxide (DLCO). Ventilation abnormalities were quantified as the VDP using two different methods: adaptive thresholding (VDPT) and k-means clustering (VDPK). Correlation and agreement between VDP quantified by Technegas SPECT and 129Xe MRI were determined by Spearman correlation and Bland-Altman analysis, respectively. Results: VDP measured by Technegas SPECT and 129Xe MRI were correlated (VDPT: r = 0.48, p = 0.001; VDPK: r = 0.63, p < 0.0001). A 2.0% and 1.6% bias towards higher Technegas SPECT VDP was measured using the adaptive threshold method (VDPT: 23.0% ± 14.0% vs. 21.0% ± 5.2%, p = 0.81) and k-means method (VDPK: 9.4% ± 9.4% vs. 7.8% ± 10.0%, p = 0.02), respectively. For both modalities, higher VDP was correlated with lower FEV1/FVC (SPECT VDPT: r = -0.38, p = 0.01; MRI VDPK: r = -0.46, p = 0.002) and DLCO (SPECT VDPT: r = -0.61, p < 0.0001; MRI VDPK: r = -0.68, p < 0.0001). Subgroup analysis revealed that VDP measured by both modalities was significantly higher for participants with COPD (n = 13) than those with asthma (n = 6; SPECT VDPT: p = 0.007, MRI VDPK: p = 0.006) and those with no history of obstructive lung disease (n = 21; SPECT VDPT: p = 0.0003, MRI VDPK: p = 0.0003). Discussion: The burden of ventilation defects quantified by Technegas SPECT and 129Xe MRI VDP was correlated and greater in participants with COPD when compared to those without. Our observations indicate that, despite substantial differences between the imaging modalities, quantitative assessment of ventilation defects by Technegas SPECT and 129Xe MRI is comparable.
RESUMO
Background In individuals with postacute COVID-19 syndrome (PACS) and normal pulmonary function, xenon 129 (129Xe) MRI ventilation defects, abnormal quality-of-life scores, and exercise limitation were reported 3 months after infection; the longitudinal trajectory remains unclear. Purpose To measure and compare pulmonary function, exercise capacity, quality of life, and 129Xe MRI ventilation defect percent (VDP) in individuals with PACS evaluated 3 and 15 months after COVID-19 infection. Materials and Methods In this prospective study, participants with PACS aged 18-80 years were enrolled between July 2020 and August 2021 from two quaternary care centers. 129Xe MRI VDP, diffusing capacity of lung for carbon monoxide (Dlco), spirometry, oscillometry, 6-minute walk distance (6MWD), and St George Respiratory Questionnaire (SGRQ) scores were evaluated 3 months and 15 months after COVID-19 infection. Differences between time points were evaluated using the paired t test. Multivariable models were generated to explain exercise capacity and quality-of-life improvement. Odds ratios (ORs) were used to evaluate potential treatment influences. Results Overall, 53 participants (mean age, 55 years ± 18 [SD]; 27 women) attended both 3- and 15-month visits and were included in the analysis. The mean values for 129Xe MRI VDP (5.8% and 4.2%; P = .003), forced expiratory volume in the 1st second of expiration percent predicted (84% and 90%; P = .001), Dlco percent predicted (86% and 99%; P = .002), and SGRQ score (35 and 25; P < .001) improved between the 3- and 15-month visit. VDP measured 3 months after COVID-19 infection predicted the change in 6MWD (ß = -0.643, P = .006), while treatment with respiratory medication at 3 months predicted an improved quality-of-life score at 15 months (OR, 4.0; 95% CI: 1.2, 13.8; P = .03). Conclusion Pulmonary function, gas exchange, exercise capacity, quality of life, and 129Xe MRI ventilation defect percent (VDP) improved in participants with postacute COVID-19 syndrome at 15 months compared with 3 months after infection. VDP measured at 3 months after infection correlated with improved exercise capacity, while treatment with respiratory medication was associated with an improved quality-of-life score 15 months after infection. ClinicalTrials.gov registration no. NCT05014516 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Vogel-Claussen in this issue.
Assuntos
COVID-19 , Transtornos Respiratórios , Feminino , Humanos , Pessoa de Meia-Idade , Pulmão , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Qualidade de Vida , Adolescente , Idoso , Idoso de 80 Anos ou mais , MasculinoRESUMO
129Xe MRI red blood cell to alveolar tissue plasma ratio (RBC:TP) abnormalities have been observed in ever-hospitalised and never-hospitalised people with postacute COVID-19 syndrome (PACS). But, it is not known if such abnormalities resolve when symptoms and quality-of-life scores improve. We evaluated 21 participants with PACS, 7±4 months (baseline) and 14±4 months (follow-up) postinfection. Significantly improved diffusing capacity of the lung for carbon monoxide (DLCO, Δ=14%pred ;95%CI 7 to 21, p<0.001), postexertional dyspnoea (Δ=-0.7; 95%CI=-0.2 to -1.2, p=0.019), St George's Respiratory Questionnaire-score (SGRQ Δ=-6; 95% CI=-1 to -11, p=0.044) but not RBC:TP (Δ=0.03; 95% CI=0.01 to 0.05, p=0.051) were observed at 14 months. DLCO correlated with RBC:TP (r=0.60, 95% CI=0.22 to 0.82, p=0.004) at 7 months. While DLCO and SGRQ measurements improved, these values did not normalise 14 months post-infection. ClinicalTrials.gov NCT04584671.
Assuntos
COVID-19 , Humanos , Seguimentos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Qualidade de Vida , Capacidade de Difusão PulmonarRESUMO
BACKGROUND: Autoimmunity has been reported in patients with severe coronavirus disease 2019 (COVID-19). We investigated whether anti-nuclear/extractable-nuclear antibodies (ANAs/ENAs) were present up to a year after infection, and if they were associated with the development of clinically relevant post-acute sequalae of COVID-19 (PASC) symptoms. METHODS: A rapid-assessment line immunoassay was used to measure circulating levels of ANAs/ENAs in 106 convalescent COVID-19 patients with varying acute phase severities at 3, 6 and 12â months post-recovery. Patient-reported fatigue, cough and dyspnoea were recorded at each time point. Multivariable logistic regression model and receiver operating curves were used to test the association of autoantibodies with patient-reported outcomes and pro-inflammatory cytokines. RESULTS: Compared to age- and sex-matched healthy controls (n=22) and those who had other respiratory infections (n=34), patients with COVID-19 had higher detectable ANAs at 3â months post-recovery (p<0.001). The mean number of ANA autoreactivities per individual decreased between 3 and 12â months (from 3.99 to 1.55) with persistent positive titres associated with fatigue, dyspnoea and cough severity. Antibodies to U1-snRNP and anti-SS-B/La were both positively associated with persistent symptoms of fatigue (p<0.028, area under the curve (AUC) 0.86) and dyspnoea (p<0.003, AUC=0.81). Pro-inflammatory cytokines such as tumour necrosis factor (TNF)-α and C-reactive protein predicted the elevated ANAs at 12â months. TNF-α, D-dimer and interleukin-1ß had the strongest association with symptoms at 12â months. Regression analysis showed that TNF-α predicted fatigue (ß=4.65, p=0.004) and general symptomaticity (ß=2.40, p=0.03) at 12â months. INTERPRETATION: Persistently positive ANAs at 12â months post-COVID are associated with persisting symptoms and inflammation (TNF-α) in a subset of COVID-19 survivors. This finding indicates the need for further investigation into the role of autoimmunity in PASC.
Assuntos
Autoanticorpos , COVID-19 , Humanos , Síndrome de COVID-19 Pós-Aguda , Fator de Necrose Tumoral alfa , Tosse , Anticorpos Antinucleares , Citocinas , FadigaRESUMO
Purpose To determine if proton (1H) MRI-derived specific ventilation is responsive to bronchodilator (BD) therapy and associated with clinical biomarkers of type 2 airway inflammation and airways dysfunction in severe asthma. Materials and Methods In this prospective study, 27 participants with severe asthma (mean age, 52 years ± 9 [SD]; 17 female, 10 male) and seven healthy controls (mean age, 47 years ± 16; five female, two male), recruited between 2018 and 2021, underwent same-day spirometry, respiratory oscillometry, and tidal breathing 1H MRI. Participants with severe asthma underwent all assessments before and after BD therapy, and type 2 airway inflammatory biomarkers were determined (blood eosinophil count, sputum eosinophil percentage, sputum eosinophil-free granules, and fraction of exhaled nitric oxide) to generate a cumulative type 2 biomarker score. Specific ventilation was derived from tidal breathing 1H MRI and its response to BD therapy, and relationships with biomarkers of type 2 airway inflammation and airway dysfunction were evaluated. Results Mean MRI specific ventilation improved with BD inhalation (from 0.07 ± 0.04 to 0.11 ± 0.04, P < .001). Post-BD MRI specific ventilation (P = .046) and post-BD change in MRI specific ventilation (P = .006) were greater in participants with asthma with type 2 low biomarkers compared with participants with type 2 high biomarkers of airway inflammation. Post-BD change in MRI specific ventilation was correlated with change in forced expiratory volume in 1 second (r = 0.40, P = .04), resistance at 5 Hz (r = -0.50, P = .01), resistance at 19 Hz (r = -0.42, P = .01), reactance area (r = -0.54, P < .01), and reactance at 5 Hz (r = 0.48, P = .01). Conclusion Specific ventilation evaluated with tidal breathing 1H MRI was responsive to BD therapy and was associated with clinical biomarkers of airways disease in participants with severe asthma. Keywords: MRI, Severe Asthma, Ventilation, Type 2 Inflammation Supplemental material is available for this article. © RSNA, 2023 See also the commentary by Moore and Chandarana in this issue.