Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 322
Filtrar
1.
Ann Thorac Surg ; 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39322053

RESUMO

BACKGROUND: It has long been held that the safe duration of hypothermic circulatory arrest (HCA) is at least 25-30 minutes. However, this is based primarily on clinical outcomes research and has not been systematically investigated using more sensitive brain imaging and neurocognitive assessments. METHODS: This exploratory sub-study of the randomized GOT ICE trial, which compared outcomes for deep versus moderate hypothermia during arch surgery, investigated the frequency of neurocognitive and structural and functional magnetic resonance imaging (MRI) deficits with short (<20 minutes) duration HCA. Neurocognitive deficit was defined as >1 standard deviation decline in >1 of 5 cognitive domains on neurocognitive testing. RESULTS: Of 228 GOT ICE patients with complete 4-week cognitive data, 74.6% (n=170/228) had HCA durations <20 minutes, including 59 randomized to deep (<20.0°C), 55 low-moderate (20.1-24.0°C), and 56 high-moderate (24.1-28.0°C) hypothermia. Of these, cognitive deficit was detected 4-weeks post-surgery in ∼40% of patients in all 3 groups [deep: 22/59 (37.3%); low-moderate: 23/55 (41.8%); high-moderate: 24/56 (42.9%)]. Furthermore, in a subset of patients with complete MRI data (n=43), baseline to 4-week post-surgery right frontal lobe functional connectivity change was inversely associated with HCA duration (range 8-17 minutes; p-FWE<0.01). CONCLUSIONS: Even short durations of HCA result in cognitive deficits in ∼40% of patients, independent of systemic hypothermia temperature. HCA duration was inversely associated with frontal lobe functional MRI connectivity, suggesting this brain region may be preferentially sensitive to HCA. Surgeons should be aware that even short durations of HCA may not provide complete neuroprotection following aortic arch surgery.

2.
Circ Genom Precis Med ; : e004512, 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39324273

RESUMO

BACKGROUND: Ascending thoracic aortic dilation is a complex heritable trait that involves modifiable and nonmodifiable risk factors. Polygenic scores (PGS) are increasingly used to assess risk for complex diseases. The degree to which a PGS can improve aortic diameter prediction in diverse populations is unknown. Presently, we tested whether adding a PGS to clinical prediction algorithms improves performance in a diverse biobank. METHODS: The analytic cohort comprised 6235 Penn Medicine Biobank participants with available echocardiography and clinical data linked to genome-wide genotype data. Linear regression models were used to integrate PGS weights derived from a genome-wide association study of thoracic aortic diameter performed in the UK Biobank and were compared with the performance of the previously published aorta optimized regression for thoracic aneurysm (AORTA) score. RESULTS: Cohort participants had a median age of 61 years (IQR, 53-70) and a mean ascending aortic diameter of 3.36 cm (SD, 0.49). Fifty-five percent were male, and 33% were genetically similar to African reference population. Compared with the AORTA score, which explained 30.6% (95% CI, 29.9%-31.4%) of the variance in aortic diameter, AORTA score+UK Biobank-derived PGS explained 33.1%, (95% CI, 32.3%-33.8%), the reweighted AORTA score explained 32.5% (95% CI, 31.8%-33.2%), and the reweighted AORTA score+UK Biobank-derived PGS explained 34.9% (95% CI, 34.2%-35.6%). When stratified by population, models including the UK Biobank-derived PGS consistently improved upon the clinical AORTA score among individuals genetically similar to European reference population but conferred minimal improvement among individuals genetically similar to African reference population. Comparable performance disparities were observed in models developed to discriminate cases/noncases of thoracic aortic dilation (≥4.0 cm). CONCLUSIONS: We demonstrated that inclusion of a UK Biobank-derived PGS to the AORTA score confers a clinically meaningful improvement in model performance only among individuals genetically similar to European reference population and may exacerbate existing health care disparities.

3.
J Chest Surg ; 57(5): 419-429, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39229636

RESUMO

The frozen elephant trunk (FET) technique can be applied to extensive aortic pathology, including lesions in the aortic arch and proximal descending thoracic aorta. FET is useful for tear-oriented surgery in dissections, managing malperfusion syndrome, and promoting positive aortic remodeling. Despite these benefits, complications such as distal stent-induced new entry and spinal cord ischemia can pose serious problems with the FET technique. To prevent these complications, careful sizing and planning of the FET are crucial. Additionally, since the FET technique involves total arch replacement, meticulous surgical skills are essential, particularly for young surgeons. In this article, we propose several techniques to simplify surgical procedures, which may lead to better outcomes for patients with extensive aortic pathology. In the era of precision medicine, the next-generation FET device could facilitate the treatment of complex aortic diseases through a patient-tailored approach.

4.
Artigo em Inglês | MEDLINE | ID: mdl-39116932

RESUMO

BACKGROUND: Outcomes after hemiarch repair for acute DeBakey type I aortic dissection (ADTI) remain unfavorable, with high rates of major adverse events and negative aortic remodeling. The PERSEVERE study evaluates the safety and effectiveness of the AMDS Hybrid prosthesis, a novel bare metal stent, in patients presenting with preoperative malperfusion. METHODS: PERSEVERE is a prospective single-arm investigational study conducted at 26 sites in the United States. Ninety-three patients underwent ADTI aortic dissection repair with AMDS implantation. The 30-day primary endpoints are a composite rate of 4 major adverse events and the rate of distal anastomotic new entry tears. The secondary endpoints include aortic remodeling. RESULTS: Clinical malperfusion was documented in 76 patients (82%); only radiographic malperfusion, in 17 (18%). The median follow-up in the 93 patients was 5.6 months. Within 30 days, 9 patients died (9.7%), 10 patients (10.8%) experienced new disabling stroke, and 18 patients (19.4%) had new-onset renal failure requiring ≥1 dialysis treatment. There were no cases of myocardial infarction. The composite rate of major adverse events (27%) was lower than that reported in the reference cohort (58%). There were no distal anastomotic new entry tears. Technical success was achieved in 99% of patients. Early remodeling indicated total aortic diameter stability, true lumen expansion, and false lumen reduction in the treated aortic segment. CONCLUSIONS: Early results show significant reductions in major adverse events and distal anastomotic new entry tears, successfully meeting both primary endpoints. The technical success rate was high. AMDS can be used safely in patients with ADTI dissection with malperfusion.

5.
Ann Thorac Surg ; 2024 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-39182554

RESUMO

BACKGROUND: We aim to evaluate the impact of antegrade stenting of the distal arch and proximal descending aorta combined with non-total arch procedures in acute type A aortic dissection. METHODS: From 2005 to 2022, 733 nonsyndromic patients presented with acute DeBakey type I aortic dissection and underwent non-total arch procedure. Ninety-five patients underwent antegrade stenting and 638 did not. Propensity-score analysis was performed, and 95 optimal pairs were created. Survival was estimated using the Kaplan-Meier method and cumulative incidence of reintervention with death as a competing event was calculated and compared using Gray's method. RESULTS: Survival estimates at 10 years after propensity score matching were similar between both groups, 58.9% (95% CI, 46.5%-74.5%) vs 58.4% (95% CI, 48.3%-70.6%) (P = .6) in the non-stented vs stented group. Cumulative incidence of reintervention with competing risk of death at 10 years after propensity matching was 27% (95% CI, 17%-37%) vs 22% (95% CI, 14%-32%) (P = .44), respectively. CONCLUSIONS: Antegrade thoracic endovascular aortic repair may be beneficial for remodeling and facilitating future endovascular reinterventions and reduces the occurrence of reintervention for malperfusion.

7.
Artigo em Inglês | MEDLINE | ID: mdl-39009336

RESUMO

BACKGROUND: The relationship between the number and type of postoperative complications and mortality in the setting for surgery for acute type A aortic dissection (ATAAD) remains underexplored despite its critical role in the failure-to-rescue (FTR) metric. METHODS: This retrospective study used data from the Society of Thoracic Surgeons Adult Cardiac Surgical Database on ATAAD surgeries performed between January 2018 and December 2022. Patients were categorized based on their number of major complications. The primary outcome was FTR. We used multilevel regression and classification and regression tree models. RESULTS: We included 19,243 patients (33% females), with a median age of 61 years. Regarding complications, 47.7% of patients had 0, 20.2% had 1, 12.7% had 2, and 19.4% experienced 3 or more. The most frequently reported complications were prolonged mechanical ventilation (30.3%), unplanned reoperation (19.5%), and renal failure (17.2%). Cardiac arrest occurred in 7.1% of cases. FTR increased from 13% in patients with 1 complication to >30% in those with 4 or more complications. Cardiac arrest (adjusted odds ratio [aOR], 10.9) and renal failure (aOR, 5.3) had the highest odds for mortality, followed by limb ischemia (aOR, 2.7), stroke (aOR, 2.6), and gastrointestinal complications (aOR, 2.4). Hospitals in the top performance quartile consistently showed lower FTR rates across all levels of complication. CONCLUSIONS: The study validates a dose-response association between postoperative complications and mortality in patients undergoing surgery for ATAAD. Top-performing hospitals consistently show lower FTR rates independent of the number of complications. Future research should focus on the timing of complications and interventions to reduce the burden of complications.

8.
Artigo em Inglês | MEDLINE | ID: mdl-39047861

RESUMO

OBJECTIVE: For patients with type A aortic dissection complicated by mesenteric malperfusion syndrome, some centers advocate a nontraditional approach based on up-front endovascular intervention and delayed open repair. However, the efficacy of this strategy cannot be understood without first understanding outcomes of the traditional open-first strategy in the same select patient population eligible for delayed repair, applying modern techniques of hybrid aortic surgery. METHODS: Patients with acute type A aortic dissection and mesenteric malperfusion syndrome were queried from a single institution. Those presenting with aortic rupture, tamponade, or cardiogenic shock (ineligible for delayed repair) were excluded. Patients were managed with immediate open aortic repair. Short-term and long-term outcomes are reported. RESULTS: A total of 1228 patients were treated for acute type A dissection in the study period, of whom 77 were included in the mesenteric malperfusion syndrome cohort. In-hospital mortality was 29% compared with 39% in an identically selected mesenteric malperfusion syndrome population undergoing delayed repair reported previously. Among patients with mesenteric malperfusion syndrome, 32% underwent additional procedures addressing distal malperfusion in a hybrid operating room during or after open repair. Concomitant proximal malperfusion (coronary, cerebral, or upper extremity) was common in the mesenteric malperfusion syndrome cohort, present in 35% of cases. Although early mortality was greater in the mesenteric malperfusion syndrome cohort compared with all acute type A dissections, 10-year survival among those discharged alive was similar (65% vs 59%, P = .18). CONCLUSIONS: The traditional open-first repair strategy performs equal to or better than the delayed repair strategy for patients with mesenteric malperfusion syndrome eligible for delayed repair.

9.
Genomics ; 116(5): 110878, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38851465

RESUMO

Traumatic perioperative conditions may trigger early systemic responses, activate leukocytes and reprogram the immune system. We hypothesize that leukocyte activation may not revert to pre-surgical states, and that protracted activation may emerge with increased risks of comorbidities. We tested this concept by examining the transcriptomes of monocytes and T cells in a representative observational cohort of patients (n = 13) admitted for elective cardiac surgery. Transcriptomes in T cells and monocytes were compared from before surgery (t0), and monocytes were analyzed longitudinally after acute (t24hr), and convalescent (t3m) time points. Monocytes and T cells expressed distinct transcriptomes, reflected by statistically significant differential expression of 558 T cell related genes. Monocytes expressed genes related to protein degradation and presented atypical activation of surface markers and cytoplasmic functions over time. Additionally, monocytes exhibited limited transcriptomic heterogeneity prior to surgery, and long-term patterns of gene expression associated with atherosclerosis showed three temporally distinct signatures. These data establish that post-cardiac surgery transcriptomes of monocytes differ even at three months compared to baselines, which may reflect latent ('smoldering') inflammation and persistent progression of tissue degenerative processes that should inform clinical care.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Inflamação , Monócitos , Transcriptoma , Humanos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Monócitos/metabolismo , Masculino , Feminino , Inflamação/genética , Inflamação/metabolismo , Idoso , Pessoa de Meia-Idade , Linfócitos T/metabolismo , Leucócitos/metabolismo
10.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866455

RESUMO

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Idoso , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Estados Unidos/epidemiologia
11.
Cardiovasc Revasc Med ; 66: 21-26, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38553277

RESUMO

BACKGROUND: Studies comparing transcatheter and surgical aortic valve replacement (TAVR and SAVR) for patients with trileaflet aortic stenosis (AS) have found similar or larger effective orifice area (EOA) for TAVR prostheses. To our knowledge, no studies have compared EOA in patients undergoing TAVR versus SAVR for bicuspid AS. METHODS: We retrospectively compared prosthetic valvular sizing and predicted EOA for patients with bicuspid AS undergoing TAVR or SAVR at our institution between January 1, 2016, and December 31, 2021. We excluded patients undergoing procedures for indications other than AS and those without a pre-procedural gated Chest CT. Comparisons included demographics, comorbidities, annular size, prosthetic valve size, predicted EOA and prosthesis-patient mismatch (PPM) for TAVR (N = 78) and SAVR (N = 74) cohorts. RESULTS: TAVR patients had smaller pre-procedural annular area (501.7 mm2 vs. 571.8 mm2, p < 0.05) and annular perimeter (80.6 mm vs. 86.5 mm, p < 0.05), but larger mean implanted prosthetic valve size (26.4 mm vs 24.2 mm, p < 0.001) compared to SAVR patients. No differences were observed in predicted EOA, predicted EOA indexed to patient body surface area (EOAi), or predicted PPM grade between TAVR and SAVR groups, including in cohorts sorted by pre-procedural annular size. CONCLUSIONS: For bicuspid AS patients undergoing aortic valve replacement, TAVR achieves similar predicted EOA to SAVR. These data support the use of TAVR in selected patients with bicuspid AS and can inform heart team discussions.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Feminino , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Masculino , Resultado do Tratamento , Idoso , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso de 80 Anos ou mais , Fatores de Risco , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Hemodinâmica , Recuperação de Função Fisiológica , Pessoa de Meia-Idade , Fatores de Tempo
12.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38316377

RESUMO

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Humanos , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Idoso de 80 Anos ou mais , Resultado do Tratamento , Ajuste de Prótese
13.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38244577

RESUMO

OBJECTIVES: There is an ongoing debate regarding whether patients benefit more from root replacement compared to a reconstruction of the sinuses of Valsalva in acute type A aortic dissection (aTAAD). In those with known or suspected connective tissue disorders, root replacement is considered appropriate. However, there are currently no diameter-based guidelines regarding the best approach in patients with minimally to moderately dilated root and no connective tissue disorders. METHODS: From January 2005 to December 2022, a two-centre registry of aTAAD was created. Patients were included based on their age (≤60 years), the absence of root entry and dilatation >50 mm and the absence of syndromic hereditable aortic disease. Patients were divided into 2 groups based on the proximal procedure, root reconstruction and root replacement. Propensity score pair matching was performed based on preoperative characteristics. RESULTS: Cumulative incidence of reintervention at 10 years was slightly higher after root reconstruction 13% vs 3.9% in the matched group (P = 0.040). Survival at 10 years was not affected by the procedure independently of the matching 72.1% vs 71.4% (P = 0.2). Uni- and multivariate Cox regressions showed that a root diameter of >40 mm was associated with a hazard ratio of 7.7 (95% confidence interval 2.6-23) and 5.4 (7-17), respectively, for reoperation for aneurysm and pseudoaneurysm. CONCLUSIONS: Rate of reoperation due to proximal pseudoaneurysm and aneurysm could be significantly reduced with a lower threshold of 40 mm to replace the aortic root in aTAAD than in elective cases.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Torácica , Doenças da Aorta , Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Pessoa de Meia-Idade , Falso Aneurisma/cirurgia , Resultado do Tratamento , Dissecção Aórtica/epidemiologia , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Doenças da Aorta/cirurgia , Estudos Retrospectivos , Aneurisma da Aorta Torácica/epidemiologia , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Reoperação , Implante de Prótese Vascular/métodos
14.
Ann Thorac Surg ; 117(1): 106-112, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37858882

RESUMO

BACKGROUND: The use of transcatheter aortic valve replacement for severe aortic stenosis in low-risk patients necessitates an evaluation of contemporary long-term, real-world outcomes of similar patients undergoing surgical aortic valve replacement (SAVR) in a national cohort. METHODS: All patients undergoing primary, isolated SAVR in The Society of Thoracic Surgeons (STS) database between 2011 and 2019 were examined. The study population of 42,586 adhered to the inclusion/exclusion criteria of the Placement of Aortic Transcatheter Valves (PARTNER) 3 and Evolut Low Risk randomized trials. Patients were further stratified by STS predicted risk of mortality (PROM), age, and left ventricular ejection fraction. The primary end-point was all-cause National Death Index mortality. Unadjusted survival to 8 years was estimated using the Kaplan-Meier method. RESULTS: Mean age was 74.3 ± 5.7 years and mean STS PROM was 1.9% ± 0.8%. The overall Kaplan-Meier time to event analysis for all-cause mortality at 1, 3, 5, and 8 years was 2.6%, 4.5%, 7.1%, and 12.4%, respectively. In subset analyses, survival was significantly better for (1) lower STS PROM (P < .001), (2) younger vs older age (P < .001), and (3) higher vs lower left ventricular ejection fraction (P < .001). When STS PROM was below 1% or the patient age was below age 75 years, the 8-year survival after SAVR was 95%. CONCLUSIONS: The results of this national study confirm that long-term survival after SAVR remains excellent, at 92.9% at 5 years. These contemporary longitudinal data serve to aid in the balanced interpretation of current and future trials comparing SAVR and transcatheter aortic valve replacement and may assist in the clinical decision-making process for patients of lower surgical risk.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Humanos , Valva Aórtica/cirurgia , Benchmarking , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Ensaios Clínicos como Assunto
15.
Circulation ; 149(9): 658-668, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-38084590

RESUMO

BACKGROUND: Deep hypothermia has been the standard for hypothermic circulatory arrest (HCA) during aortic arch surgery. However, centers worldwide have shifted toward lesser hypothermia with antegrade cerebral perfusion. This has been supported by retrospective data, but there has yet to be a multicenter, prospective randomized study comparing deep versus moderate hypothermia during HCA. METHODS: This was a randomized single-blind trial (GOT ICE [Cognitive Effects of Body Temperature During Hypothermic Circulatory Arrest]) of patients undergoing arch surgery with HCA plus antegrade cerebral perfusion at 4 US referral aortic centers (August 2016-December 2021). Patients were randomized to 1 of 3 hypothermia groups: DP, deep (≤20.0 °C); LM, low-moderate (20.1-24.0 °C); and HM, high-moderate (24.1-28.0 °C). The primary outcome was composite global cognitive change score between baseline and 4 weeks postoperatively. Analysis followed the intention-to-treat principle to evaluate if: (1) LM noninferior to DP on global cognitive change score; (2) DP superior to HM. The secondary outcomes were domain-specific cognitive change scores, neuroimaging findings, quality of life, and adverse events. RESULTS: A total of 308 patients consented; 282 met inclusion and were randomized. A total of 273 completed surgery, and 251 completed the 4-week follow-up (DP, 85 [34%]; LM, 80 [34%]; HM, 86 [34%]). Mean global cognitive change score from baseline to 4 weeks in the LM group was noninferior to the DP group; likewise, no significant difference was observed between DP and HM. Noninferiority of LM versus DP, and lack of difference between DP and HM, remained for domain-specific cognitive change scores, except structured verbal memory, with noninferiority of LM versus DP not established and structured verbal memory better preserved in DP versus HM (P = 0.036). There were no significant differences in structural or functional magnetic resonance imaging brain imaging between groups postoperatively. Regardless of temperature, patients who underwent HCA demonstrated significant reductions in cerebral gray matter volume, cortical thickness, and regional brain functional connectivity. Thirty-day in-hospital mortality, major morbidity, and quality of life were not different between groups. CONCLUSIONS: This randomized multicenter study evaluating arch surgery HCA temperature strategies found low-moderate hypothermia noninferior to traditional deep hypothermia on global cognitive change 4 weeks after surgery, although in secondary analysis, structured verbal memory was better preserved in the deep group. The verbal memory differences in the low- and high-moderate groups and structural and functional connectivity reductions from baseline merit further investigation and suggest opportunities to further optimize brain perfusion during HCA. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02834065.


Assuntos
Aorta Torácica , Hipotermia , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Estudos Retrospectivos , Estudos Prospectivos , Qualidade de Vida , Método Simples-Cego , Temperatura Corporal , Parada Circulatória Induzida por Hipotermia Profunda/efeitos adversos , Perfusão/efeitos adversos , Perfusão/métodos , Cognição , Circulação Cerebrovascular , Resultado do Tratamento
16.
J Thorac Cardiovasc Surg ; 167(4): 1185-1193.e1, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37156365

RESUMO

OBJECTIVE: Reoperative sternotomy is associated with poor outcomes after cardiac surgery. We aimed to investigate the impact of reoperative sternotomy on the outcomes after aortic root replacement. METHODS: All patients who underwent aortic root replacement from January 2011 to June 2020 were identified using the Society of Thoracic Surgeons Adult Cardiac Surgery Database. We compared outcomes between patients who underwent first-time aortic root replacement with those with a history of sternotomy undergoing reoperative sternotomy aortic root replacement using propensity score matching. Subgroup analysis was performed among the reoperative sternotomy aortic root replacement group. RESULTS: A total of 56,447 patients underwent aortic root replacement. Among them, 14,935 (26.5%) underwent reoperative sternotomy aortic root replacement. The annual incidence of reoperative sternotomy aortic root replacement increased from 542 in 2011 to 2300 in 2019. Aneurysm and dissection were more frequently observed in the first-time aortic root replacement group, whereas infective endocarditis was more common in the reoperative sternotomy aortic root replacement group. Propensity score matching yielded 9568 pairs in each group. Cardiopulmonary bypass time was longer in the reoperative sternotomy aortic root replacement group (215 vs 179 minutes, standardized mean difference = 0.43). Operative mortality was higher in the reoperative sternotomy aortic root replacement group (10.8% vs 6.2%, standardized mean difference = 0.17). In the subgroup analysis, logistic regression demonstrated that individual patient repetition of (second or more resternotomy) surgery and annual institutional volume of aortic root replacement were independently associated with operative mortality. CONCLUSIONS: The incidence of reoperative sternotomy aortic root replacement might have increased over time. Reoperative sternotomy is a significant risk factor for morbidity and mortality in aortic root replacement. Referral to high-volume aortic centers should be considered in patients undergoing reoperative sternotomy aortic root replacement.


Assuntos
Valva Aórtica , Implante de Prótese de Valva Cardíaca , Adulto , Humanos , Estados Unidos/epidemiologia , Valva Aórtica/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Aorta/cirurgia , Esternotomia/efeitos adversos , Reoperação , Implante de Prótese de Valva Cardíaca/efeitos adversos
17.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38109506

RESUMO

OBJECTIVES: This study aimed to evaluate employing the German Registry of Acute Aortic Dissection Type A (GERAADA) score to predict 30-day mortality in an aortic centre in the USA. METHODS: Between January 2010 and June 2021, 689 consecutive patients underwent surgery for acute type A dissection at a single institution. Excluded were patients with missing clinical data (N = 4). The GERAADA risk score was retrospectively calculated via a web-based application. Model discrimination power was calculated with c-statistics from logistic regression and reported as the area under the receiver operating characteristic curve with 95% confidence intervals. The calibration was measured by calculating the observed versus estimated mortality ratio. The Brier score was used for the overall model evaluation. RESULTS: Included were 685 patients [mean age 60.6 years (SD: 13.5), 64.8% male] who underwent surgery for acute type A aortic dissection. The 30-day mortality rate was 12.0%. The GERAADA score demonstrated very good discrimination power with an area under the receiver operating characteristic curve of 0.762 (95% confidence interval 0.703-0.821). The entire cohort's observed versus estimated mortality ratio was 0.543 (0.439-0.648), indicating an overestimation of the model-calculated risk. The Brier score was 0.010, thus revealing the model's acceptable overall performance. CONCLUSIONS: The GERAADA score is a practical and easily accessible tool for reliably estimating the 30-day mortality risk of patients undergoing surgery for acute type A aortic dissection. This model may naturally overestimate risk in patients undergoing surgery in experienced aortic centres.


Assuntos
Dissecção Aórtica , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Dissecção Aórtica/cirurgia , Sistema de Registros , Fatores de Risco
18.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37874020

RESUMO

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Seguimentos , Readmissão do Paciente , Insuficiência Cardíaca/etiologia
19.
Artigo em Inglês | MEDLINE | ID: mdl-37657715

RESUMO

OBJECTIVE: To determine the relationship between volume of cases and failure-to-rescue (FTR) rate after surgery for acute type A aortic dissection (ATAAD) across the United States. METHODS: The Society of Thoracic Surgeons adult cardiac surgery database was used to review outcomes of surgery after ATAAD between June 2017 and December 2021. Mixed-effect models and restricted cubic splines were used to determine the risk-adjusted relationships between ATAAD average volume and FTR rate. FTR calculation was based on deaths associated with the following complications: venous thromboembolism/deep venous thrombosis, stroke, renal failure, mechanical ventilation >48 hours, sepsis, gastrointestinal complications, cardiopulmonary resuscitation, and unplanned reoperation. RESULTS: In total, 18,192 patients underwent surgery for ATAAD in 832 centers. The included hospitals' median volume was 2.2 cases/year (interquartile range [IQR], 0.9-5.8). Quartiles' distribution was 615 centers in the first (1.3 cases/year, IQR, 0.4-2.9); 123 centers in the second (8 cases/year, IQR, 6.7-10.2); 66 centers in the third (15.6 cases/year, IQR, 14.2-18); and 28 centers in the fourth quartile (29.3 cases/year, IQR, 28.8-46.0). Fourth-quartile hospitals performed more extensive procedures. Overall complication, mortality, and FTR rates were 52.6%, 14.2%, and 21.7%, respectively. Risk-adjusted analysis demonstrated increased odds of FTR when the average volume was fewer than 10 cases per year. CONCLUSIONS: Although high-volume centers performed more complex procedures than low-volume centers, their operative mortality was lower, perhaps reflecting their ability to rescue patients and mitigate complications. An average of fewer than 10 cases per year at an institution is associated with increased odds of failure to rescue patients after ATAAD repair.

20.
medRxiv ; 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37732226

RESUMO

Background: Ascending thoracic aortic dilation is a complex trait that involves modifiable and non-modifiable risk factors and can lead to thoracic aortic aneurysm and dissection. Clinical risk factors have been shown to predict ascending thoracic aortic diameter. Polygenic scores (PGS) are increasingly used to assess clinical risk for multifactorial diseases. The degree to which a PGS can improve aortic diameter prediction is not known. In this study we tested the extent to which the addition of a PGS to clinical prediction algorithms improves the prediction of aortic diameter. Methods: The patient cohort comprised 6,790 Penn Medicine Biobank (PMBB) participants with available echocardiography and clinical data linked to genome-wide genotype data. Linear regression models were used to integrate PGS weights derived from a large genome wide association study of thoracic aortic diameter in the UK biobank and were compared to the performance of the standard and a reweighted variation of the recently published AORTA Score. Results: Cohort participants were 56% male, had a median age of 61 years (IQR 52-70) with a mean ascending aortic diameter of 3.4 cm (SD 0.5). Compared to the AORTA Score which explained 28.4% (95% CI 28.1% to 29.2%) of the variance in aortic diameter, AORTA Score + PGS explained 28.8%, (95% CI 28.1% to 29.6%), the reweighted AORTA score explained 30.4% (95% CI 29.6% to 31.2%), and the reweighted AORTA Score + PGS explained 31.0% (95% CI 30.2% to 31.8%). The addition of a PGS to either the AORTA Score or the reweighted AORTA Score improved model sensitivity for the identifying individuals with a thoracic aortic diameter ≥ 4 cm. The respective areas under the receiver operator characteristic curve for the AORTA Score + PGS (0.771, 95% CI 0.756 to 0.787) and reweighted AORTA Score + PGS (0.785, 95% CI 0.770 to 0.800) were greater than the standard AORTA Score (0.767, 95% CI 0.751 to 0.783) and reweighted AORTA Score (0.780 95% CI 0.765 to 0.795). Conclusions: We demonstrated that inclusion of a PGS to the AORTA Score results in a small but clinically meaningful performance enhancement. Further investigation is necessary to determine if combining genetic and clinical risk prediction improves outcomes for thoracic aortic disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...