Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Hinyokika Kiyo ; 70(6): 161-166, 2024 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-38967028

RESUMO

A 71-year-old man presented with exertional dyspnea. Chest radiography revealed multiple pulmonary nodules, and contrast-enhanced computed tomography showed findings suspicious of right renal pelvic cancer. Percutaneous lung tumor biopsy revealed a histological diagnosis of urothelial carcinoma, and right renal pelvic cancer cT3N2M1 was diagnosed. Favorable response was shown during primary chemotherapy with gemcitabine and cisplatin but resulted in tumor progression after four cycles. The patient was switched to a second-line treatment, pembrolizumab, which resulted in rapid tumor growth. Hyper-progression was suspected, and the patient was promptly switched to a third-line treatment, enfortumab vedotin. The tumor shrank significantly. After three treatment cycles, an adverse event of enteritis was observed. A biopsy of the intestinal mucosa led to a histopathologic diagnosis of late-onset immune-related adverse event; therefore, enfortumab vedotin could be continued.


Assuntos
Anticorpos Monoclonais , Humanos , Masculino , Idoso , Anticorpos Monoclonais/efeitos adversos , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/patologia , Neoplasias Renais/tratamento farmacológico , Neoplasias Renais/patologia
3.
Circ J ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39010218

RESUMO

BACKGROUND: We examined the safety and efficacy of acceleration training (AT) in patients immediately after cardiac surgery.Methods and Results: This randomized controlled study included patients who underwent open-heart surgery using cardiopulmonary bypass. Of these patients, 31 received regular cardiac rehabilitation (CR) and 39 received AT in addition to regular CR (AT group). AT was provided using a vibration platform (Power Plate®Pro7TMand Power plate®personal; Performance Health System, Chicago, IL, USA). The AT group performed 5 static resistance training sessions: squats, wide stance squats, toe stands, banded squats, and front lunges. Each vibration session lasted 30 s. We evaluated the short physical performance battery, anterior mid-thigh thickness, maximum voluntary isometric contraction of the knee extensors, and serum intercellular adhesion molecule (ICAM-1) and vascular cell adhesion molecule (VCAM-1) concentrations as indicators of endothelial function. The observation period was during hospitalization and lasted approximately 20 days. No adverse events occurred during AT. Ultrasound revealed a significantly lower reduction in muscle mass at discharge in the AT group. No significant differences were observed in ICAM-1 and VCAM-1 concentrations between the 2 groups preoperatively, postoperatively, or at discharge. CONCLUSIONS: AT is considered safe and effective for patients immediately after open-heart surgery. AT, along with regular CR, may prevent skeletal muscle mass loss, muscle weakness, and physical function loss immediately after open-heart surgery.

4.
Anesth Analg ; 139(2): 385-396, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39008867

RESUMO

BACKGROUND: Currently, clinical indicators for evaluating endothelial permeability in sepsis are unavailable. Endothelium-derived extracellular vesicles (EDEVs) are emerging as biomarkers of endothelial injury. Platelet endothelial cell adhesion molecule (PECAM) and vascular endothelial (VE)-cadherin are constitutively expressed endothelial intercellular adhesion molecules that regulate intercellular adhesion and permeability. Herein, we investigated the possible association between EDEVs expressing intercellular adhesion molecules (PECAM+ or VE-cadherin+ EDEVs) and endothelial permeability and sepsis severity. METHODS: Human umbilical vein endothelial cells (HUVECs) were stimulated with tumor necrosis factor alpha (TNF-α) directly or after pretreatment with permeability-modifying reagents such as angiopoietin-1, prostacyclin, or vascular endothelial growth factor (VEGF) to alter TNF-α-induced endothelial hyperpermeability. Endothelial permeability was measured using the dextran assay or transendothelial electrical resistance. Additionally, a prospective cross-sectional observational study was conducted to analyze circulating EDEV levels in patients with sepsis. EDEVs were examined in HUVEC culture supernatants or patient plasma (nonsepsis, n = 30; sepsis, n = 30; septic shock, n = 42) using flow cytometry. The Wilcoxon rank-sum test was used for comparisons between 2 groups. Comparisons among 3 or more groups were performed using the Steel-Dwass test. Spearman's test was used for correlation analysis. Statistical significance was set at P < .05. RESULTS: TNF-α stimulation of HUVECs significantly increased EDEV release and endothelial permeability. Pretreatment with angiopoietin-1 or prostacyclin suppressed the TNF-α-induced increase in endothelial permeability and inhibited the release of PECAM+ and VE-cadherin+ EDEVs. In contrast, pretreatment with VEGF increased TNF-α-induced endothelial permeability and the release of PECAM+ and VE-cadherin+ EDEVs. However, pretreatment with permeability-modifying reagents did not affect the release of EDEVs expressing inflammatory stimulus-inducible endothelial adhesion molecules such as E-selectin, intracellular adhesion molecule-1, or vascular cell adhesion molecule-1. The number of PECAM+ EDEVs on admission in the septic-shock group (232 [124, 590]/µL) was significantly higher (P = .043) than that in the sepsis group (138 [77,267]/µL), with an average treatment effect of 98/µL (95% confidence interval [CI], 2-270/µL), and the number of VE-cadherin+ EDEVs in the septic-shock group (173 [76,339]/µL) was also significantly higher (P = .004) than that in the sepsis group (81 [42,159]/µL), with an average treatment effect (ATE) of 79/µL (95% CI, 19-171/µL); these EDEV levels remained elevated until day 5. CONCLUSIONS: EDEVs expressing intercellular adhesion molecules (PECAM+ or VE-cadherin+ EDEVs) may reflect increased endothelial permeability and could be valuable diagnostic and prognostic markers for sepsis.


Assuntos
Antígenos CD , Caderinas , Permeabilidade Capilar , Vesículas Extracelulares , Células Endoteliais da Veia Umbilical Humana , Sepse , Índice de Gravidade de Doença , Humanos , Vesículas Extracelulares/metabolismo , Sepse/metabolismo , Células Endoteliais da Veia Umbilical Humana/metabolismo , Masculino , Estudos Prospectivos , Antígenos CD/metabolismo , Feminino , Pessoa de Meia-Idade , Caderinas/metabolismo , Idoso , Fator de Necrose Tumoral alfa/metabolismo , Fator de Necrose Tumoral alfa/farmacologia , Estudos Transversais , Células Cultivadas , Angiopoietina-1/metabolismo , Biomarcadores/metabolismo , Biomarcadores/sangue , Molécula-1 de Adesão Celular Endotelial a Plaquetas/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo , Endotélio Vascular/metabolismo , Epoprostenol/metabolismo
5.
Am J Dermatopathol ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38648029

RESUMO

ABSTRACT: Information regarding the genetic alterations in extramammary Paget disease (EMPD) is scarce. This study investigated the significance of CDKN2A and MTAP alterations in EMPD progression using immunohistochemistry and panel DNA sequencing. In total, 24 invasive/metastatic EMPD cases were included in this study. The immunoexpression of p16 and MTAP in the primary in situ, primary invasive, and metastatic tumor components was evaluated. Panel DNA sequencing was performed for metastatic tumor components in 5 of the 24 cases. Immunoexpression of p16 in the in situ tumor component was at least partially preserved in all 19 tested cases (100%). By contrast, the invasive tumor component was diffusely or partially lost in 18 (81.8%) of 22 tested cases. Regarding the foci of lymph node metastasis, 13 (81.2%) of the 16 patients showed a significant loss of p16 expression. Loss of MTAP immunoexpression was observed less frequently compared with the loss of p16 expression. CDKN2A homozygous deletions were confirmed in all 5 tested cases by sequencing, whereas MTAP deletions were detected in only 2 cases. In conclusion, p16 expression loss and CDKN2A deletions can be frequently seen in invasive/metastatic cases of EMPD.

6.
Circ J ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658351

RESUMO

BACKGROUND: Sacubitril/valsartan, being both a neprilysin inhibitor and angiotensin receptor blocker, exhibits a renin-angiotensin-aldosterone system (RAAS) inhibitory effect. However, no study has investigated the administration of sacubitril/valsartan in patients early after surgery using cardiopulmonary bypass.Methods and Results: This was a prospective observational study of 63 patients who underwent open heart surgery and were treated with sacubitril/valsartan. No serious adverse events occurred. Among the 63 patients, sacubitril/valsartan was discontinued in 13 due to hypotension (n=10), renal dysfunction (n=2), and dizziness (n=1). Atrial natriuretic peptide concentrations increased significantly from Day 3 of treatment (P=0.0142 vs. Postoperative Day 1) and remained high thereafter. In contrast, plasma renin activity was significantly suppressed from Day 3 onwards (P=0.00206 vs. Postoperative Day 1). A decrease in creatinine concentrations and an increase in the estimated glomerular filtration rate were observed on Day 3; this improvement in renal function was not observed in the historical control group, in which patients did not receive sacubitril/valsartan. New postoperative atrial fibrillation was less frequent in the study group compared with the historical control (12.7% vs. 38.0%; P=0.0034). CONCLUSIONS: Sacubitril/valsartan administration was safe immediately after open heart surgery in patients without postoperative hypotension. It enhanced serum atrial natriuretic peptide concentrations and suppressed RAAS activation.

7.
IEEE Trans Haptics ; 17(1): 8-13, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38190670

RESUMO

This study aims to represent fine texture differences in pencil hardness using intensity segment modulation (ISM), a sensory equivalent conversion method of vibration from high to low frequencies. This method enables the presentation of delicate tactile sensations even with small transducers. We integrated this approach in the world's thinnest ultra-thin PZT-MEMS vibrator with a stylus-type device. The vibration waveforms of four types of pencil hardness were captured under the same conditions, and the differences in the frequency components were confirmed. We compared the fine texture feelings under raw signal, ISM, and ISM below 1 kHz conditions by conducting discrimination tests and subjective similarity evaluations. The results showed that ISM could reproduce similar feelings of the pencil hardness.


Assuntos
Sistemas Microeletromecânicos , Percepção do Tato , Humanos , Dureza , Tato , Vibração
8.
IEEE Trans Haptics ; 17(1): 20-25, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38227399

RESUMO

Thin and light vibrators that leverage the inverse piezoelectric effect with a diaphragm mechanism are promising vibrotactile actuators owing to their form factors and high temporal and frequency response. However, generating perceptually sufficient displacement in the low-frequency domain is challenging. This study presents a lever mechanism mounted on a diaphragm vibrator to enhance the vibrotactile intensity of low-frequency vibrotactile stimuli. The lever mechanism is inspired by the tactile contact lens consisting of an array of cylinders held against the skin on a sheet that enhances micro-bump tactile detection. We built an experimental apparatus including our previously developed thin-film diaphragm-type vibrator, which reproduced the common characteristic of piezoelectric vibrators: near-threshold displacement (10 to 20 µm) at low frequency. Experiments demonstrated enhanced vibrotactile intensity at frequencies less than 100 Hz with the lever mechanism. Although the arrangement and material of the mechanism can be improved, our findings can help improve the expressiveness of diaphragm-type vibrators.


Assuntos
Percepção do Tato , Humanos , Diafragma , Tato/fisiologia , Pele , Vibração
9.
Surg Today ; 54(5): 428-435, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37668736

RESUMO

PURPOSE: The present study investigated potential access vessels in patients receiving hemodialysis who underwent surgical aortic valve replacement and determined which approaches were most suitable for performing transcatheter aortic valve implantation. METHODS: Consecutive patients undergoing hemodialysis with aortic valve stenosis who underwent surgical aortic valve replacement were included. Preoperative computed tomography data were analyzed to assess the vessel diameter and calcification. Simulations were conducted to determine the feasibility of inserting the 14-F eSheath of Sapien 3 via transfemoral, trans-cervical, trans-subclavian, and direct aorta approaches. RESULTS: A total of 72 patients were included in this study. The access route was characterized by severe calcification of the common iliac artery. The transfemoral approach was feasible in 77.8% of the cases, but the rate decreased to 33% when the calculations were based on the maximum sheath extension diameter. The trans-cervical, trans-subclavian, and direct aortic approaches were suitable for many patients. Lower extremity artery disease was identified as a risk factor for the unsuitability of the transfemoral approach. CONCLUSIONS: Common iliac artery calcification in patients undergoing hemodialysis restricts the use of the transfemoral approach. Therefore, some patients require alternative approaches.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Diálise Renal , Artéria Femoral/cirurgia
10.
J Cardiol ; 83(3): 211-218, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37648079

RESUMO

In a world increasingly confronted by cardiovascular diseases (CVDs) and an aging population, accurate risk assessment prior to cardiac surgery is critical. Although effective, traditional risk calculators such as the Japan SCORE, Society of Thoracic Surgeons score, and EuroSCORE II may not completely capture contemporary risks, particularly due to emerging factors such as frailty and sarcopenia. These calculators often focus on regional and ethnic specificity and rely heavily on evaluations based on age and underlying diseases. Growth differentiation factor-15 (GDF-15) is a stress-responsive cytokine that has been identified as a potential biomarker for sarcopenia and a tool for future cardiac risk assessment. Preoperative plasma GDF-15 levels have been associated with preoperative, intraoperative, and postoperative factors and short- and long-term mortality rates in patients undergoing cardiac surgery. Increased plasma GDF-15 levels have prognostic significance, having been correlated with the use of cardiopulmonary bypass during surgery, amount of bleeding, postoperative acute kidney injury, and intensive care unit stay duration. Notably, the inclusion of preoperative levels of GDF-15 in risk stratification models enhances their predictive value, especially when compared with those of the N-terminal prohormone of brain natriuretic peptide, which does not lead to reclassification. Thus, this review examines traditional risk assessments for cardiac surgery and the role of the novel biomarker GDF-15. This study acknowledges that the relationship between patient outcomes and elevated GDF-15 levels is not limited to CVDs or cardiac surgery but can be associated with variable diseases, including diabetes and cancer. Moreover, the normal range of GDF-15 is not well defined. Given its promise for improving patient care and outcomes in cardiovascular surgery, future research should explore the potential of GDF-15 as a biomarker for postoperative outcomes and target therapeutic intervention.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doenças Cardiovasculares , Sarcopenia , Humanos , Idoso , Fator 15 de Diferenciação de Crescimento , Biomarcadores , Prognóstico , Doenças Cardiovasculares/etiologia
11.
J Cardiol ; 83(4): 228-235, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37926367

RESUMO

The importance of temporary mechanical circulatory support for treating acute heart failure with cardiogenic shock is increasingly recognized, and Impella (Abiomed, Danvers, MA, USA) has received particular attention in this regard. Impella is an axial flow left ventricular assist device (LVAD) built into the tip of a catheter. It is inserted via a peripheral artery and implanted into the left ventricle. Although the morphology of Impella is different from a typical LVAD, it has similar actions and effects as an LVAD in terms of left ventricular drainage and aortic blood delivery. Impella increases mean arterial pressure (MAP) and systemic blood flow, thereby improving peripheral organ perfusion and promoting recovery from multiple organ failure. In addition, left ventricular unloading with increased MAP increases coronary perfusion and decreases myocardial oxygen demand, thereby promoting myocardial recovery. Impella is also useful as a mechanical vent of the left ventricle in patients supported with veno-arterial extracorporeal membrane oxygenation. Indications for Impella include emergency use for cardiogenic shock and non-emergent use during high-risk percutaneous coronary intervention and ventricular tachycardia ablation. Its intended uses for cardiogenic shock include bridge to recovery, durable device, heart transplantation, and heart surgery. Prophylactic use of Impella in high-risk patients undergoing open heart surgery to prevent postcardiotomy cardiogenic shock is also gaining attention. While there have been many case reports and retrospective studies on the benefits of Impella, there is little evidence based on sufficiently large randomized controlled trials (RCTs). Currently, several RCTs are now ongoing, which are critical to determine when, for whom, and how these devices should be used. In this review, we summarize the principles, physiology, indications, and complications of the Impella support and discuss current issues and future expectations for the device.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/cirurgia , Coração Auxiliar/efeitos adversos , Motivação , Insuficiência Cardíaca/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
12.
Artigo em Inglês | MEDLINE | ID: mdl-37948001

RESUMO

OBJECTIVE: We evaluated the blood flow within the downstream aortic false lumen after frozen elephant trunk repair for acute aortic dissection and identified hemodynamic predictors of false lumen expansion and negative false lumen remodeling using four-dimensional flow magnetic resonance imaging. METHODS: Thirty-one patients (Stanford type A, n = 28; Stanford type B, n = 3) with patent false lumen who underwent frozen elephant trunk procedures for acute aortic dissection were included in this observational study. Each patient underwent computed tomography during the follow-up period and four-dimensional flow magnetic resonance imaging within 3 postoperative months. The false lumen volumetric expansion rate was calculated using computed tomography data. The direction and the rate of flow in the lower descending aortic false lumen were analyzed. Negative false lumen remodeling was defined as a volumetric increase of > 10% from the baseline volume. RESULTS: Negative false lumen remodeling had developed in 6 of the 31 patients during the observation period. Most of the false lumen flows were biphasic during systole. The range between peak and nadir flow rates was associated with the false lumen volumetric expansion rate (ß coefficient = 6.77; p < 0.01, R2 = 0.43). CONCLUSIONS: The range between peak and nadir flow rates may serve as a hemodynamic predictor of negative false lumen remodeling, enabling further treatment for patients at risk of expansion in the downstream aorta.

13.
BMC Cardiovasc Disord ; 23(1): 436, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37658328

RESUMO

BACKGROUND: Recent guidelines state that improving the survival rate of patients with ruptured abdominal aortic aneurysm (rAAA) requires a protocol or algorithm for the emergency management of these patients. We aimed to investigate whether introducing a protocol treatment for rAAA improves clinical outcomes compared with the pre-protocol strategy. METHODS: At our institution, 92 patients treated for rAAA between June 2008 and August 2022 were retrospectively analyzed. In 2014, the protocol-based treatment was introduced comprising a transfer algorithm to shorten the time to proximal control, use of an endovascular occlusion balloon, strict indications for endovascular aortic aneurysm repair (EVAR) or open surgical repair, and perioperative care, including for abdominal compartment syndrome (ACS). Clinical outcomes were compared between the protocol and pre-protocol group, including operative status, all-cause mortality, and rAAA-related death at 30-day, in-hospital, and 1-year postoperative follow-ups. RESULTS: Overall, 52 and 40 patients received the protocol-based and pre-protocol treatments, respectively. EVAR was more frequently performed in the protocol group. The rate of achieving time to proximal control was significantly faster, and the transfusion volume was lower in the protocol group. ACS occurred more frequently in the protocol group with a higher EVAR. No difference was found in all-cause mortality between the two groups. The protocol group exhibited fewer rAAA-related deaths than the pre-protocol group during the following time points: 30 days (9.6% vs. 22.5%), during the hospital stay (11.5% vs. 30.0%), and 1 year (14.5% vs. 31.5%). CONCLUSIONS: The protocol-based treatment improved the survival rate of patients with rAAA.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Humanos , Estudos Retrospectivos , Algoritmos , Aorta , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia
14.
Surg Case Rep ; 9(1): 155, 2023 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-37665417

RESUMO

BACKGROUND: Transcatheter valve replacement is contraindicated in patients with active infective endocarditis. However, few reports suggest that it could be beneficial for high-risk surgical patients with healed infective endocarditis. Here, we report a case of a surgical transcatheter aortic valve in a patient with healed repeated prosthetic valve endocarditis using a stentless valve. CASE PRESENTATION: A 79-year-old female who underwent the Bentall procedure using a stentless valve and coronary artery bypass grafting for annuloaortic ectasia 22 years ago was hospitalized for stage II bioprosthetic valve failure. The patient had a history of prosthetic valve endocarditis three times: the first and second prosthetic valve endocarditis occurred 15 years ago, and the third prosthetic valve endocarditis occurred 3 years ago. The causative organisms were Campylobacter fetus and Enterococcus faecalis. With appropriate antibiotic therapy, the lesion was localized and healed completely without valve destruction; however, the patient developed rapid aortic regurgitation. Based on a review of the patient's history of prosthetic valve endocarditis, the absence of signs of infection, and clinical findings of transesophageal echocardiography and computed tomography, a diagnosis of structural valve deterioration with healed infective endocarditis was made. Subsequently, a transcatheter aortic valve in a surgical aortic valve using a balloon-expandable type was performed, because the patient had a high surgical risk of 12.7%. The patient's postoperative course was uneventful. At the 1-year follow-up, there were no signs of infection or valve abnormalities. CONCLUSIONS: Transcatheter valve replacement can be a treatment option for high-risk surgical patients with healed limited lesions in infective endocarditis.

15.
Front Surg ; 10: 1224013, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37538391

RESUMO

Introduction: The frozen elephant trunk technique is a surgical procedure developed for concomitant repair of downstream descending thoracic aorta as a first stage operation for arch resections. Proximalization of the sutured anastomosis reduces technical difficulty of total arch replacement. In this procedure, an anastomosis is performed more proximally using a stent graft. Connect the head and neck vessels are created using in-situ fenestration method. Case presentation: This study presents the case of a 78-year-old woman with a large thoracic aortic arch aneurysm that was successfully treated with a modified frozen elephant trunk technique (open in situ fenestration). For this method, a hole was created in the neck branches (the left subclavian artery and left common carotid artery), and peripheral stent grafts were placed to simplify neck branch reconstruction. This minimized the risk of recurrent laryngeal nerve injury and bleeding and shortened the procedure time. Conclusion: The outcomes of this study showed a safe alternative total arch replacement procedure.

16.
J Clin Med ; 12(10)2023 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-37240566

RESUMO

Coronavirus disease 2019 (COVID-19) is associated with coagulopathy. However, the underlying mechanisms are not completely understood. We evaluated the association between COVID-19 coagulopathy and extracellular vesicle (EV) levels. We hypothesized that several EV levels would be higher in COVID-19 coagulopathy patients than in non-coagulopathy patients. This prospective observational study was conducted in four tertiary care faculties in Japan. We enrolled 99 COVID-19 patients (48 with coagulopathy and 51 without coagulopathy) aged ≥20 years who required hospitalization, and 10 healthy volunteers; we divided the patients into coagulopathy and non-coagulopathy groups according to the D-dimer levels (≥1 µg/mL and <1 µg/mL, respectively). We used flow cytometry to measure the tissue-factor-bearing, endothelium-derived, platelet-derived, monocyte-derived, and neutrophil-derived EV levels in platelet-free plasma. The EV levels were compared between the two COVID-19 groups as well as among the coagulopathy patients, non-coagulopathy patients, and healthy volunteers. No significant difference was found in EV levels between the two groups. Meanwhile, the cluster of differentiation (CD) 41 + EV levels were significantly higher in COVID-19 coagulopathy patients than in healthy volunteers (549.90 [255.05-984.65] vs. 184.3 [150.1-254.1] counts/µL, p = 0.011). Therefore, CD41+ EVs might play an essential role in COVID-19 coagulopathy development.

17.
Sci Rep ; 13(1): 6503, 2023 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-37081122

RESUMO

This study investigates a cantilever-based pressure sensor that can achieve a resolution of approximately 0.2 mPa, over the frequency range of 0.1-250 Hz. A piezoresistive cantilever with ultra-high acoustic compliance is used as the sensing element in the proposed pressure sensor. We achieved a cantilever with a sensitivity of approximately 40 times higher than that of the previous cantilever device by realizing an ultrathin (340 nm thick) structure with large pads and narrow hinges. Based on the measurement results, the proposed pressure sensor can measure acoustic signals with frequencies as low as 0.1 Hz. The proposed pressure sensor can be used to measure low-frequency pressure and sound, which is crucial for various applications, including photoacoustic-based gas/chemical sensing and monitoring of physiological parameters and natural disasters. We demonstrate the measurement of heart sounds with a high SNR of 58 dB. We believe the proposed microphone will be used in various applications, such as wearable health monitoring, monitoring of natural disasters, and realization of high-resolution photoacoustic-based gas sensors. We successfully measured the first (S1) and second (S2) cardiac sounds with frequencies of 7-100 Hz and 20-45 Hz, respectively.


Assuntos
Ruídos Cardíacos , Desastres Naturais , Acústica , Som
18.
J Cardiothorac Vasc Anesth ; 37(7): 1143-1151, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37076386

RESUMO

OBJECTIVES: The clinical use of less-invasive devices that calculate the cardiac output from arterial pressure waveform is increasing. The authors aimed to evaluate the accuracy and characteristics of the systemic vascular resistance index (SVRI) of the cardiac index measured by 2 less-invasive devices, fourth-generation FloTrac (CIFT) and LiDCOrapid (CILR), compared with the intermittent thermodilution technique, using a pulmonary artery catheter (CITD). DESIGN: This was a prospective observational study. SETTING: This study was conducted at a single university hospital. PARTICIPANTS: Twenty-nine adult patients undergoing elective cardiac surgery. INTERVENTIONS: Elective cardiac surgery was used as an intervention. MEASUREMENTS AND MAIN RESULTS: Hemodynamic parameters, CIFT, CILR, and CITD, were measured after the induction of general anesthesia, at the start of cardiopulmonary bypass, after completion of weaning from cardiopulmonary bypass, 30 minutes after weaning, and at sternal closure (135 measurements in total). The CIFT and CILR had moderate correlations with CITD (r = 0.62 and 0.58, respectively). Compared with CITD, CIFT, and CILR had a bias of -0.73 and -0.61 L/min/m2, limit of agreement of -2.14-to-0.68 L/min/m2 and -2.42-to-1.20 L/min/m2, and percentage error of 39.9% and 51.2%, respectively. Subgroup analysis for evaluating SVRI characteristics showed that the percentage errors of CIFT and CILR were 33.9% and 54.5% in low SVRI (<1,200 dyne×s/cm5/m), 37.6% and 47.9% in moderate SVRI (1,200-1,800 dyne×s/cm5/m), 49.3% and 50.6% in high SVRI (>1,800 dyne·s/cm5/m2), respectively. CONCLUSIONS: The accuracy of CIFT or CILR was not clinically acceptable for cardiac surgery. Fourth-generation FloTrac was unreliable in high SVRI. LiDCOrapid was inaccurate across a broad range of SVRI, and minimally affected by SVRI.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Monitorização Intraoperatória , Adulto , Humanos , Monitorização Intraoperatória/métodos , Débito Cardíaco , Resistência Vascular , Hemodinâmica , Procedimentos Cirúrgicos Cardíacos/métodos , Termodiluição/métodos , Reprodutibilidade dos Testes
19.
J Cardiol ; 81(5): 491-497, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36503063

RESUMO

Post-myocardial infarction ventricular septal rupture (PIVSR) is becoming increasingly rare in the percutaneous coronary intervention era; however, the mortality rates remain high. Surgical repair is the gold standard treatment for PIVSR but is associated with surgical difficulty and high mortality. Therefore, the timing of surgery is controversial (i.e. either undertake emergency surgery or wait for resolution of organ failure and scarring of the infarcted area). Although long-term medical management is usually ineffective, several mechanical circulatory support (MCS) devices have been used to postpone surgery to an optimal timing. Recently, in addition to venous arterial extracorporeal membrane oxygenation (VA-ECMO), new MCS devices, such as Impella (Abiomed Inc., Boston, MA, USA), have been developed. Impella is a pump catheter that pumps blood directly from the left ventricle, in a progressive fashion, into the ascending aorta. VA-ECMO is a temporary MCS system that provides complete and rapid cardiopulmonary support, with concurrent hemodynamic support and gas exchange. When left and right heart failure and/or respiratory failure occur in cardiogenic shock or PIVSR after acute myocardial infarction, ECpella (Impella and VA-ECMO) is often introduced, as it can provide circulatory and respiratory assistance in a shorter period. This review outlines the basic concepts of MCS in PIVSR treatment strategies and its role as a bridge device, and discusses the efficacy and complications of ECpella therapy and the timing of surgery.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Infarto do Miocárdio , Ruptura do Septo Ventricular , Humanos , Ruptura do Septo Ventricular/etiologia , Ruptura do Septo Ventricular/cirurgia , Coração Auxiliar/efeitos adversos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Insuficiência Cardíaca/complicações , Resultado do Tratamento
20.
Sci Rep ; 12(1): 19308, 2022 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-36369527

RESUMO

This paper describes the fabrication and fundamental evaluation of the cubic flocked electrode (CFE), which is a dry electrode that is fabricated using electrostatic flocking technology. The development of a wearable multi-lead electrocardiogram (ECG) measurement device using the CFE is also reported. To enable the measurement of ECG signals with sufficient quality for medical applications, the occurrence of motion artifacts (MAs) is the most important problem to be overcome. Therefore, it is necessary to stabilize the contact between the patient's skin and the dry electrode. Because the CFE developed in this work offers both contact stability and flexibility, it is expected to enable ECG measurements with low MA levels. In this study, it is demonstrated that the number of MAs caused by respiration can be reduced when the CFE contact is made at a contact pressure of approximately 500 Pa using MA evaluation equipment that was developed in-house. Additionally, a wearable multi-lead ECG is designed and fabricated based on this contact pressure (500 Pa). The results of the demonstration experiment show that the ECG measurements are successful to the same extent as a conventional medical device.


Assuntos
Eletrocardiografia , Dispositivos Eletrônicos Vestíveis , Humanos , Eletrocardiografia/métodos , Eletrodos , Artefatos , Eletricidade Estática
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...