Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Curr Issues Mol Biol ; 46(4): 3342-3352, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38666939

RESUMO

Increasing the soybean-planting area and increasing the soybean yield per unit area are two effective solutions to improve the overall soybean yield. Northeast China has a large saline soil area, and if soybeans could be grown there with the help of isolated saline-tolerant rhizobia, the soybean cultivation area in China could be effectively expanded. In this study, soybeans were planted in soils at different latitudes in China, and four strains of rhizobia were isolated and identified from the soybean nodules. According to the latitudes of the soil-sampling sites from high to low, the four isolated strains were identified as HLNEAU1, HLNEAU2, HLNEAU3, and HLNEAU4. In this study, the isolated strains were identified for their resistances, and their acid and saline tolerances and nitrogen fixation capacities were preliminarily identified. Ten representative soybean germplasm resources in Northeast China were inoculated with these four strains, and the compatibilities of these four rhizobium strains with the soybean germplasm resources were analyzed. All four isolates were able to establish different extents of compatibility with 10 soybean resources. Hefeng 50 had good compatibility with the four isolated strains, while Suinong 14 showed the best compatibility with HLNEAU2. The isolated rhizobacteria could successfully establish symbiosis with the soybeans, but host specificity was also present. This study was a preliminary exploration of the use of salinity-tolerant rhizobacteria to help the soybean nitrogen fixation in saline soils in order to increase the soybean acreage, and it provides a valuable theoretical basis for the application of saline-tolerant rhizobia.

2.
Small ; : e2312207, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38299717

RESUMO

The flexible aqueous rechargeable sodium-ion batteries (ARSIBs) are a promising portable energy storage system that can meet the flexibility and safety requirements of wearable electronic devices. However, it faces huge challenges in mechanical stability and facile manufacturing processes. Herein, the first fully-printed flexible ARSIBs with appealing mechanical performance by screen-printing technique is prepared, which utilizes Na3 V2 (PO4 )2 F3 /C (NVPF/C) as the cathode and 2% nitrogenous carbon-loaded Na3 MnTi(PO4 )3 /C (NMTP/C/NC) as the anode. In particular, the organic co-solvent ethylene glycol (EG) is cleverly added to 17 m (mol kg-1 ) NaClO4 electrolyte to prepare a 17 m NaClO4 -EG mixed electrolyte. This mixed electrolyte can withstand low temperatures of -20 °C in practical applications. Encouragingly, the fully-printed flexible ARSIBs (NMTP/C/NC//NVPF/C) exhibit a discharge capacity of 40.1 mAh g-1 , an energy density of 40.1 Wh kg-1 , and outstanding cycle performance. Moreover, these batteries with various shapes can be used as an energy wristband for an electronic watch in the bending states. The fully-printed flexible ARSIBs in this work are expected to shed light on the development of energy for wearable electronics.

3.
BMC Urol ; 23(1): 161, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37828507

RESUMO

BACKGROUND: To summarize the efficacy of combined robot-assisted laparoscopy and ureteroscopy in treating complex ureteral strictures. METHODS: Eleven patients underwent combined robot-assisted laparoscopy and ureteroscopy for ureteral strictures between January 2020 and August 2022. Preoperative B-ultrasound, glomerular filtration rate measurement, and intravenous pyelography showed different degrees of hydronephrosis in the affected kidney and moderate to severe stenosis in the corresponding part of the ureter. During the operation, stricture segment resection and end-to-end anastomosis were performed using the da Vinci robot to find the stricture point under the guidance of a ureteroscopic light source in the lateral or supine lithotomy position. RESULTS: All the patients underwent robot-assisted laparoscopy and ureteroscopy combined with end-to-end ureterostenosis. There were no conversions to open surgery or intraoperative complications. Significant ureteral stricture segments were found in all patients intraoperatively; however, stricture length was not significantly different from the imaging findings. Patients were followed up for 3-27 months. Two months postoperatively, the double-J stent was removed, a ureteroscopy was performed, the ureteral mucosa at the end-to-end anastomosis grew well, and the lumen was patent in all patients. Furthermore, imaging examination showed that hydronephrosis was significantly improved in all patients, with grade I hydronephrosis in three cases and grade 0 hydronephrosis in eight cases. No recurrence of ureteral stricture was observed in patients followed up for > 1 year. CONCLUSION: Robot-assisted laparoscopy combined with ureteroscopy is an effective method for treating complex ureteral strictures and can achieve accurate localization of the structured segment.


Assuntos
Hidronefrose , Laparoscopia , Robótica , Ureter , Obstrução Ureteral , Humanos , Ureteroscopia/métodos , Constrição Patológica/cirurgia , Obstrução Ureteral/diagnóstico por imagem , Obstrução Ureteral/cirurgia , Ureter/cirurgia , Laparoscopia/métodos , Hidronefrose/cirurgia , Hidronefrose/complicações , Estudos Retrospectivos
4.
J Control Release ; 363: 221-234, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37717657

RESUMO

Checkpoint blockade immunotherapy (CBI) have exhibited remarkable benefits for cancer therapy. However, the low responsivity of CBI hinders its application in treatment of bladder cancer. Ferroptosis shows potential for increasing the responsivity of CBI by inducing immunogenic cell death (ICD) process. Herein, we developed a mitochondrial-targeted liposome loaded with brequinar (BQR) (BQR@MLipo) for enhancing the mitochondrial-related ferroptosis in bladder cancer in situ. It could be found that BQR@MLipo could selectively accumulate into mitochondria and inactivate dihydroorotate dehydrogenase (DHODH), which induced extensive mitochondrial lipid peroxidation and ROS, finally triggering ferroptosis of bladder cancer cells to boost the release of intracellular damage-associated molecular patterns (DAMPs) such as calreticulin (CRT), adenosine triphosphate (ATP), high mobility group box 1 (HMGB1). In addition, BQR@MLipo further promoted the release of mtDNA into the cytoplasm to activate the cGAS-STING pathway for the secretion of IFN-ß, which would increase the cross-presentation of antigens by dendritic cells and macrophage phagocytosis. Furthermore, the in vivo studies revealed that BQR@MLipo could remarkably accumulate into the bladder tumor and successfully initiate the infiltration of CD8+ T cells into tumor microenvironment for enabling efficient CBI to inhibit bladder tumor growth. Therefore, BQR@MLipo may represent a clinically promising modality for enhancing CBI in bladder tumor.


Assuntos
Ferroptose , Neoplasias da Bexiga Urinária , Humanos , Linfócitos T CD8-Positivos , Inibidores de Checkpoint Imunológico , Lipossomos , Imunoterapia , Neoplasias da Bexiga Urinária/tratamento farmacológico , Mitocôndrias , Linhagem Celular Tumoral , Microambiente Tumoral
5.
Nanoscale Adv ; 5(15): 3905-3913, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37496627

RESUMO

Experimental and clinical studies have reported phenomena of long-range fluid flow in interstitial space. However, its behaviours and functions are yet to be addressed. The imaging of the interstitial stream in vivo can clarify its transportation route and allow further understanding of physiological mechanisms and clinical relevance. Here to illustrate the route of the interstitial stream leading to the kidney, we design and synthesize a magnetic resonance imaging (MRI) contrast agent PAA-g-(DTPA-gadolinium). This MRI agent has a high longitudinal relaxivity for higher MRI contrast and large size to avoid leakage across the interstitial space. Using dynamic contrast enhanced MRI, histochemical staining, and trace element analysis of gadolinium, we track the nano-scale PAA-g-(DTPA-gadolinium) transported in the interstitial stream. The agent can be applied for a wide range of imaging and analysis of tissues and organs, thereby enabling advances in the fields of physiology, pathology, and pharmacology.

6.
Magn Reson Imaging ; 34(3): 326-33, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26616004

RESUMO

Detecting the oscillatory currents with a specific frequency distribution may have the potential to make neuronal current MRI (ncMRI) come true. The phase shift or dephasing induced by both positive and negative episodes of oscillatory neuronal currents is likely to be canceled out over the echo time in typical BOLD-contrast fMRI experiments. Based on the contrast of rotary saturation, both of the recently developed spin-locked oscillatory excitation (SLOE) and stimulus-induced rotary saturation (SIRS) pulse sequences have been demonstrated to be able to detect weak oscillatory magnetic fields in phantoms with 3T MR scanners. In this report, through Bloch equation simulation as well as water phantom and anesthetic rats experiments, we comprehensively evaluate and compare the sensitivities of these two methods (SLOE and SIRS) in detecting the oscillatory magnetic fields for both high (100 Hz) and low (10 Hz) oscillation frequencies, while using their respective optimal imaging parameters. In agreement with the theoretical predications, both the simulated and experimental results showed that the SLOE method features a much higher detection sensitivity of weak magnetic fields than that of the SIRS method. SLOE was able to detect applied oscillatory magnetic fields as low as 0.1 nT in a water phantom and 0.5 nT in rat brains and the deteriorated noise levels in rat data may account for the reduced sensitivity in vivo. These promising results form the foundation for direct detection of in vivo neuronal currents using MRI.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética , Algoritmos , Animais , Mapeamento Encefálico/métodos , Simulação por Computador , Cobre/química , Humanos , Aumento da Imagem/métodos , Masculino , Neurônios/patologia , Neurônios/fisiologia , Oscilometria , Imagens de Fantasmas , Ratos , Ratos Sprague-Dawley , Sensibilidade e Especificidade , Água/química
7.
Magn Reson Med ; 76(1): 222-8, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26302037

RESUMO

PURPOSE: To develop a novel three-dimensional (3D) sequence for susceptibility weighted imaging that is able to reduce scan time substantially while maintaining high image signal-to-noise ratio (SNR). METHODS: The proposed fast T2 *-weighted sequence was based on a 3D full-balanced gradient frame and a pair of crusher gradients. The pair of crusher gradients were used to shift MR signal from the repetition time where the MR signal was originated to a later repetition time to enhance T2 * weighting. To avoid image SNR reduction due to the repeated signal excitations by later RF pulses, as it would occur for typical echo-shifted (ES) FLASH, an interslab scan mode for the fast T2 *-weighted sequence was introduced for signal acquisition. The effectiveness of this novel sequence was evaluated by comparing it with 3D FLASH and ES-FLASH sequences. RESULTS: The proposed interslab ES T2 *-weighted sequence was able to reduce the scan time by half with a SNR comparable to the typical multislab FLASH. Besides, it yielded a higher image SNR than the traditional multislab ES-FLASH and was more flexible than the whole-volume ES-FLASH. CONCLUSION: An interslab ES sequence was developed with high time efficiency and relatively high image SNR compared with the conventional acquisition sequences. Magn Reson Med 76:222-228, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Algoritmos , Encéfalo/anatomia & histologia , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Processamento de Sinais Assistido por Computador , Imagem de Difusão por Ressonância Magnética/instrumentação , Humanos , Aumento da Imagem/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
8.
Med Phys ; 42(2): 637-644, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28102607

RESUMO

PURPOSE: To improve adaptive reconstruction of multichannel MR images by simultaneously removing nonsmooth phase and signal-loss imaging artifacts. METHODS: The improved adaptive reconstruction consists of three steps: (1) modified multichannel images are first derived by dividing raw multichannel images by a reference image (i.e., a normalized single-channel image); (2) the modified multichannel images are smoothed by a low-pass filter; (3) adaptive spatial matched filters determined from the smoothed multichannel images are utilized to obtain multichannel combined images. Numerical simulations, as well as MRI experiments, on phantoms and human subjects are performed to evaluate and compare the effectiveness of this improved adaptive reconstruction approach against traditional coil combination methods. RESULTS: Both simulation and MRI experimental results demonstrated that the proposed improved adaptive reconstruction method is able to obtain combined images with reduced nonsmooth phase and signal-loss imaging artifacts. CONCLUSIONS: A novel multichannel image reconstruction method is developed that produces high quality multichannel combined images.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Artefatos , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética/instrumentação , Modelos Teóricos , Imagens de Fantasmas , Software
9.
Magn Reson Med ; 74(2): 578-88, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25105249

RESUMO

PURPOSE: To develop a high performance, cost-effective digital optical console for scalable multichannel MRI. METHODS: The console system was implemented with flexibility and efficiency based on a modular architecture with distributed pulse sequencers. High-speed serial links were optimally utilized to interconnect the system, providing fast digital communication with a multi-gigabit data rate. The conventional analog radio frequency (RF) chain was replaced with a digital RF manipulation. The acquisition electronics were designed in close proximity to RF coils and preamplifiers, using a digital optical link to transmit the MR signal. RESULTS: A prototype of the console was constructed with a broad frequency range from direct current to 100 MHz. A temporal resolution of 1 µs was achieved for both the RF and gradient operations. The MR signal was digitized in the scanner room with an overall dynamic range between 16 and 24 bits and was transmitted to a master controller over a duplex optic fiber with a high data rate of 3.125 gigabits per second. High-quality phantom and human images were obtained using the prototype on both 0.36T and 1.5T clinical MRI scanners. CONCLUSION: A homemade digital optical MRI console with high-speed serial interconnection has been developed to better serve imaging research and clinical applications.


Assuntos
Redes de Comunicação de Computadores/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Dispositivos Ópticos , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
10.
Rev Sci Instrum ; 85(9): 094705, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25273752

RESUMO

A home-made high-field magnetic resonance imaging (MRI) spectrometer with multiple receiving channels is described. The radio frequency (RF) transceiver of the spectrometer consists of digital intermediate frequency (IF) circuits and corresponding mixing circuits. A direct digital synthesis device is employed to generate the IF pulse; the IF signal from a down-conversion circuit is sampled and followed by digital quadrature detection. Both the IF generation and the IF sampling use a 50 MHz clock. An oven-controlled crystal oscillator, which has outstanding spectral purity and a compact circuit, is used as the local oscillator of the RF transceiver. A digital signal processor works as the pulse programmer of the spectrometer, as a result, 32 control lines can be generated simultaneously while an event is triggered. Field programmable gate array devices are utilized as the auxiliary controllers of the IF generation, IF receiving, and gradient control. High performance, including 1 µs time resolution of the soft pulse, 1 MHz receiving bandwidth, and 1 µs time resolution of the gradient waveform, is achieved. High-quality images on a 1.5 T MRI system using the spectrometer are obtained.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Encéfalo , Desenho de Equipamento , Humanos
11.
Rev Sci Instrum ; 83(10): 104701, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126784

RESUMO

A digital receiver module for magnetic resonance imaging (MRI) with detailed hardware implementations is presented. The module is based on a direct sampling scheme using the latest mixed-signal circuit design techniques. A single field-programmable gate array chip is employed to perform software-based digital down conversion for radio frequency signals. The modular architecture of the receiver allows multiple acquisition channels to be implemented on a highly integrated printed circuit board. To maintain the phase coherence of the receiver and the exciter in the context of direct sampling, an effective phase synchronization method was proposed to achieve a phase deviation as small as 0.09°. The performance of the described receiver module was verified in the experiments for both low- and high-field (0.5 T and 1.5 T) MRI scanners and was compared to a modern commercial MRI receiver system.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...