Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Radiography (Lond) ; 24(2): e37-e43, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29605123

RESUMO

INTRODUCTION: Producing x-ray images for radiostereometric analysis (RSA) is a demanding technique. Suboptimal examinations result in a high percentage of exposure repetition. The aim of this pilot study was to use an experiential training approach to sharpen the skills of radiographers in acquiring images of an optimal quality. METHODS: A controlled trial using action research strategy was used. The study entailed a two phased approach. Radiographers were purposefully recruited and trained to perform the required investigations. Each phase included 12 examinations of a total knee arthroplasty phantom followed by 10 patient examinations. The quality of all x-ray images performed during the two phases was characterized by measuring the number of visible beads, the center position of the prosthesis (CP) compared to the center of calibration field (CCF). The number of re-exposures used to obtain a usable image during patient examinations was also recorded. RESULTS: The radiographers undergoing the training resulted in a significant improvement in the quality of images produced and visualization of the beads. That is, the ability to move the CP on average 36.1 mm closer to the CCF (p < 0.001), the number of visible beads increased by 3.1 (p < 0.001) and radiographers needed 2.1-2.9 exposures less to obtain RSA images of sufficient qualities during patient examinations in phase 2 (p < 0.001). CONCLUSION: This study illustrates the value of experiential method of teaching and learning with minimal compromise on patient safety but a significant contribution in terms of establishing quality of RSA images.


Assuntos
Pessoal Técnico de Saúde/educação , Artroplastia do Joelho , Competência Clínica , Análise Radioestereométrica/normas , Tecnologia Radiológica/educação , Calibragem , Pesquisa sobre Serviços de Saúde , Humanos , Imagens de Fantasmas , Projetos Piloto , Doses de Radiação
2.
Radiography (Lond) ; 24(2): e31-e36, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29605122

RESUMO

INTRODUCTION: Increasing pressure in the clinic requires a more standardized approach to radiostereometric analysis (RSA) imaging. The aim of this study was to investigate whether implementation of personalized RSA patient protocols could increase image quality and decrease examination time and the number of exposure repetitions. METHODS: Forty patients undergoing primary total hip arthroplasty were equally randomized to either a case or a control group. Radiographers in the case group were assisted by personalized patient protocols containing information about each patient's post-operative RSA imaging. Radiographers in the control group used a standard RSA protocol. RESULTS: At three months, radiographers in the case group significantly reduced (p < 0.001) the number of exposures by 1.6, examination time with 19.2 min, and distance between centrum of prosthesis and centrum of calibration field with 34.1 mm when compared to post-operative (baseline) results. At twelve months, the case group significantly reduced (p < 0.001) number of exposures by two, examination time with 22.5 min, and centrum of prosthesis to centrum of calibration field distance with 43.1 mm when compared to baseline results. No significant improvements were found in the control group at any time point. CONCLUSION: There is strong evidence that personalized RSA patient protocols have a positive effect on image quality and radiation dose savings. Implementation of personal patient protocols as a RSA standard will contribute to the reduction of examination time, thus ensuring a cost benefit for department and patient safety.


Assuntos
Artroplastia de Quadril , Protocolos Clínicos , Análise Radioestereométrica/normas , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação
3.
Radiography (Lond) ; 23(4): e80-e86, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28965908

RESUMO

INTRODUCTION: The purpose of this study was to design and evaluate a radiostereometric analysis (RSA) program aimed at radiographers in order to increase their cognitive and practical skills, thereby increasing image quality and minimizing exposure repetition. METHODS AND MATERIALS: Twenty radiographers were randomized into two identically sized study groups. Training consisted of a theoretical and practical workshop using a phantom. Tests were performed to compare the effect of training to nontraining, and the effect of time duration on the maintenance of RSA skills. The effect of training was measured by a written test and three defined parameters influencing image quality. RESULTS: Group A reduced significantly (p < 0.001) by 31.3 mm (21-31%) the distance between the centrum of the prosthesis (CP) and the centrum of the calibration field (CCF) and increased the number of beads (NB) visible by 3.6 (out of 18). A further significant reduction of 5.1 mm (p = 0.023), 1.0 bead more (p < 0.001) and a 2.1 (p = 0.022) point better rotation of the prosthesis (RP) was registered two months later. Group B was tested twice without training and no significant improvement was registered. One month after training group B had experienced overall significant improvement on a par with group A. CONCLUSION: It is realistic to implement an RSA X-ray training program where radiographers significantly improve their theoretical and practical skills in centering the CP closer to the CCF, NB and RP. A duration of up to two months after training does not influence the quality of participants' performance.


Assuntos
Competência Clínica , Radiologia/educação , Análise Radioestereométrica/normas , Currículo , Avaliação Educacional , Humanos , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Imagens de Fantasmas
4.
J Bone Joint Surg Br ; 94(6): 787-92, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22628593

RESUMO

The purpose of this study was to investigate whether a gender-specific high-flexion posterior-stabilised (PS) total knee replacement (TKR) would offer advantages over a high-flex PS TKR regarding range of movement (ROM), 'feel' of the knee, pain and satisfaction, as well as during activity. A total of 24 female patients with bilateral osteoarthritis entered this prospective, blind randomised trial in which they received a high-flex PS TKR in one knee and a gender-specific high-flexion PS TKR in the other knee. At follow-up, patients were assessed clinically measuring ROM, and questioned about pain, satisfaction and daily 'feel' of each knee. Patients underwent gait analysis pre-operatively and at one year, which yielded kinematic, kinetic and temporospatial parameters indicative of knee function during gait. At final follow-up we found no statistically significant differences in ROM (p = 0.82). The median pain score was 0 (0 to 8) in both groups (p = 0.95). The median satisfaction score was 9 (4 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.98). The median 'feel' score was 9 (3 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.66). Gait analysis showed no statistically significant differences between the two prosthetic designs in any kinematic, kinetic or temporospatial parameters. Both designs produced good clinical results with significant improvements in several gait parameters without evidence of any advantage in the gender-specific design.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Caracteres Sexuais , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Método Duplo-Cego , Feminino , Marcha , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/etiologia , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento Articular , Resultado do Tratamento
5.
Br Poult Sci ; 44(2): 161-9, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12828199

RESUMO

1. The use of outdoor areas by two broiler strains, known to have different growth rates and with access to either moderate (M) or low (L) energy feeds, was examined to assess the consequences for production, meat quality, health and welfare. 2. Sixteen groups of either Ross 208 (ROSS) or a Labresse cross (LAB) were fed either feed M or L. They were raised indoors until 42 d of age when groups of 102 birds were moved to outdoor houses with free access to an outdoor area. 3. The number of chickens standing and lying, respectively, in each of 5 zones in the outdoor area were recorded at intervals throughout the outdoor growth period until slaughter at 84 d of age. Production variables were measured, and gait, feather condition, litter quality, and dermal lesions on foot-pads and hocks were scored together with objective meat quality measures. 4. Both strains showed a diurnal rhythm with most birds observed outside around sunrise and before sunset. Feed and strain both affected the distribution of the birds on the outdoor area, with more birds on feed M than L observed outside, and with more LAB birds outside and using more of the outdoor area than ROSS. This was reflected in some of the carcase and meat quality measures. Feather pecking and cannibalism only occurred in LAB. 5. ROSS was found to have a faster growth rate, poorer litter quality, more dermal lesions and impaired mobility, reflected in low usage of outdoor area and poor gait score compared with LAB. 6. This together with the presence of pectoral myopathies make ROSS unsuitable for 12 week growth in free range production systems. The occurrence of feather pecking and cannibalism in LAB make this particular Labresse cross questionable for meat-type poultry production.


Assuntos
Agressão , Criação de Animais Domésticos/métodos , Galinhas/fisiologia , Carne/normas , Ração Animal , Bem-Estar do Animal , Animais , Galinhas/genética , Galinhas/crescimento & desenvolvimento , Ritmo Circadiano , Plumas , Abrigo para Animais , Distribuição Aleatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...