Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Am J Trop Med Hyg ; 104(2): 567-575, 2020 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-33350379

RESUMO

Although Japanese encephalitis virus (JEV) infection is an important cause of acute febrile illness in Lao PDR (Laos), patient outcome has not been evaluated. We prospectively followed up 123 JEV-infected patients (70 children < 15 years and 53 adults ≥ 15 years) admitted at Mahosot Hospital, Vientiane, from 2003 to 2013. Japanese encephalitis virus infection was diagnosed by the detection of anti-JEV IgM in cerebrospinal fluid and/or IgM seroconversion. Neurological sequelae were assessed using the Liverpool Outcome Score (LOS), total (maximum score = 75), and final (maximum score = 5). The median (interquartile range [IQR]) age of the patients was 12.0 (7.5-18.8) years, and 57% were male. The median (IQR) duration of patients' follow-up was 4.5 (3.2-7.3) years. Of all patients, 10/123 (8.1%) died during hospitalization, and 13/123 (10.6%) died at home after discharge, giving a mortality of 18.7% (23/123) (33 [26.8%] patients were lost to follow-up). The frequency of neurological sequelae at the last follow-up was 61.2% (48.4% in adults and 69.4% in children, P = 0.135). The proportion of patients with severe and moderate functional impairment at the last follow-up was significantly higher in children (25%) than in adults (6.5%), P = 0.042. Half of the patients who were still alive at the last follow-up (67) and for whom LOS data were available (22) had improvements in their total and final LOS between discharge and the last follow-up. The total and final LOS at discharge were not significantly different between children and adults, but total LOS at the last follow-up was significantly higher in adults than in children (median [IQR]: 74.5 [73-75] versus 73.0 [73-75], P = 0.019).


Assuntos
Anticorpos Antivirais/sangue , Encefalite Japonesa/epidemiologia , Hospitais/estatística & dados numéricos , Adolescente , Adulto , Criança , Pré-Escolar , Vírus da Encefalite Japonesa (Espécie)/patogenicidade , Encefalite Japonesa/diagnóstico , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Imunoglobulina M/sangue , Laos/epidemiologia , Masculino , Estudos Prospectivos , Adulto Jovem
2.
PLoS Negl Trop Dis ; 12(1): e0006203, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29377886

RESUMO

Few data on dengue epidemiology are available for Lao PDR. Here, we provide information on the complexity of dengue epidemiology in the country, demonstrating dynamic circulation that varies over space and time, according to serotype. We recruited 1,912 consenting patients presenting with WHO dengue criteria at Mahosot Hospital, Vientiane (central Laos), between 2006 and 2010. Between 2008 and 2010, 1,413 patients with undifferentiated fever were also recruited at Luang Namtha (LNT) Provincial Hospital (northern Laos) and 555 at Salavan (SV) Provincial Hospital (southern Laos). We report significant variations in Dengue virus (DENV) circulation between the three sites. Peaks of DENV infection were observed in the rainy seasons, although 11% of confirmed cases in the provinces and 4.6% in the capital were detected during the dry and cool seasons (between December and February). Four DENV serotypes were detected among the 867 RT-PCR positive patients: 76.9% DENV-1, 9.6% DENV-2, 7.7% DENV-4 and 5.3% DENV-3. DENV-1 was the predominant serotype throughout the study except in LNT in 2008 and 2009 when it was DENV-2. Before July 2009, DENV-2 was not detected in SV and only rarely detected in Vientiane. DENV-3 and DENV-4 were commonly detected in Vientiane, before 2008 for DENV-4 and after 2009 for DENV-3. The phylogenetic analyses of DENV envelope sequences suggest concurrent multiple introductions of new strains as well as active DENV circulation throughout Laos and with neighboring countries. It is therefore of great importance to develop and strengthen a year-round nation-wide surveillance network in order to collect data that would allow anticipation of public health issues caused by the occurrence of large dengue outbreaks.


Assuntos
Vírus da Dengue/classificação , Vírus da Dengue/isolamento & purificação , Dengue/epidemiologia , Epidemiologia Molecular , Sorogrupo , Adolescente , Adulto , Criança , Pré-Escolar , Vírus da Dengue/genética , Monitoramento Epidemiológico , Humanos , Laos/epidemiologia , Pessoa de Meia-Idade , Filogeografia , Estações do Ano , Topografia Médica , Adulto Jovem
3.
Trans R Soc Trop Med Hyg ; 111(8): 373-377, 2017 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29244182

RESUMO

Background: Japanese encephalitis virus (JEV) is a leading identified cause of encephalitis in Asia, often occurring in rural areas with poor access to laboratory diagnostics. We evaluated two rapid diagnostic tests (RDTs) for anti-JEV immunoglobulin M (IgM) detection. Methods: Consecutive cerebrospinal fluid and serum from 388 patients (704 samples) with suspected JEV infections admitted to six hospitals in Laos were tested with one of two SD-Bioline anti-JEV IgM RDTs and the World Health Organization standard anti-JEV IgM enzyme-linked immunosorbent assay (ELISA; Panbio Japanese Encephalitis-Dengue IgM Combo ELISA. Results and Conclusions: The performance of both RDTs showed strikingly low sensitivity in comparison to anti-JEV IgM antibody capture ELISA (2.1-51.4%), suggesting low sensitivity of the RDTs. We highlight the fundamental prerequisite to validate RDTs prior to use to ensure that they meet standards for testing.


Assuntos
Anticorpos Antivirais/metabolismo , Líquido Cefalorraquidiano/química , Cromatografia de Afinidade , Vírus da Encefalite Japonesa (Espécie)/imunologia , Encefalite Japonesa/diagnóstico , Imunoglobulina M/metabolismo , Adolescente , Adulto , Criança , Pré-Escolar , Encefalite Japonesa/epidemiologia , Feminino , Humanos , Laos/epidemiologia , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
4.
Am J Trop Med Hyg ; 87(1): 171-178, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22764310

RESUMO

Japanese encephalitis virus (JEV) is a major cause of encephalitis in Asia. We estimated the diagnostic accuracy of two anti-JEV immunoglobulin M (IgM) enzyme-linked immunosorbent assays (ELISAs) (Panbio and XCyton JEVCheX) compared with a reference standard (AFRIMS JEV MAC ELISA) in a prospective study of the causes of central nervous system infections in Laos. Cerebrospinal fluid (CSF; 515 patients) and serum samples (182 patients) from those admitted to Mahosot Hospital, Vientiane, were tested. The CSF from 14.5% of acute encephalitis syndrome (AES) patients and 10.1% from those with AES and meningitis were positive for anti-JEV IgM in the reference ELISA. The sensitivities for CSF were 65.4% (95% confidence interval [CI] = 51-78) (Xcyton), 69.2% (95% CI = 55-81) (Panbio), however 96.2% (95% CI = 87-100) with Panbio Ravi criteria. Specificities were 89-100%. For admission sera from AES patients, sensitivities and specificities of the Panbio ELISA were 85.7% (95% CI = 42-100%) and 92.9% (95% CI = 83-98%), respectively.


Assuntos
Infecções do Sistema Nervoso Central/diagnóstico , Encefalite Japonesa/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina M/imunologia , Adolescente , Adulto , Infecções do Sistema Nervoso Central/sangue , Infecções do Sistema Nervoso Central/líquido cefalorraquidiano , Criança , Encefalite Japonesa/sangue , Encefalite Japonesa/líquido cefalorraquidiano , Feminino , Humanos , Laos , Masculino , Estudos Prospectivos
5.
Am J Trop Med Hyg ; 87(3): 573-575, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22826488

RESUMO

We examined the comparative performance of serum and plasma (in dipotassium EDTA) in Panbio Dengue enzyme-linked immunosorbent assays (ELISAs) for detection of non-structural protein 1 (NS1), IgM, and IgG, and a dengue/Japanese encephalitis virus (JEV) combination IgM ELISA in a prospective series of 201 patients with suspected dengue in Laos. Paired comparisons of medians from serum and plasma samples were not significantly different for Dengue IgM, and NS1 which had the highest number of discordant pairs (both 2%; P = 0.13 and P = 0.25, respectively). Comparison of qualitative final diagnostic interpretations for serum and plasma samples were not significantly different: only 1.5% (3 of 201 for Dengue/JEV IgM and Dengue IgG) and 2.0% (4 of 201; IgM and NS1) showed discordant pairs. These results demonstrate that plasma containing EDTA is suitable for use in these ELISAs.


Assuntos
Dengue/diagnóstico , Encefalite Japonesa/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Plasma/virologia , Soro/virologia , Vírus da Dengue/isolamento & purificação , Vírus da Dengue/patogenicidade , Ácido Edético/química , Vírus da Encefalite Japonesa (Espécie)/isolamento & purificação , Vírus da Encefalite Japonesa (Espécie)/patogenicidade , Humanos , Laos , Plasma/química , Estudos Prospectivos , Soro/química
6.
Trop Med Int Health ; 16(1): 127-33, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20958892

RESUMO

OBJECTIVE: To examine the accuracy of the admission tourniquet test in the diagnosis of dengue infection among Lao adults. METHODS: Prospective assessment of the predictive diagnostic value of the tourniquet test for the diagnosis of dengue infection, as defined by IgM, IgG and NS1 ELISAs (Panbio Ltd, Australia), among Lao adult inpatients with clinically suspected dengue infection. RESULTS: Of 234 patients with clinically suspected dengue infection on admission, 73% were serologically confirmed to have dengue, while 64 patients with negative dengue serology were diagnosed as having scrub typhus (39%), murine typhus (11%), undetermined typhus (12%), Japanese encephalitis virus (5%), undetermined flavivirus (5%) and typhoid fever (3%); 25% had no identifiable aetiology. The tourniquet test was positive in 29.1% (95% CI = 23.2-34.9%) of all patients and in 34.1% (95% CI = 27.0-41.2%) of dengue-seropositive patients, in 32.7% (95% CI = 23.5-41.8) of those with dengue fever and in 36.4% (95% CI = 24.7-48.0) of those with dengue haemorrhagic fever. Interobserver agreement for the tourniquet test was 90.2% (95% CI = 86.4-94.0) (Kappa = 0.76). Using ELISAs as the diagnostic gold standard, the sensitivity of the tourniquet test was 33.5-34%; its specificity was 84-91%. The positive and negative predictive values were 85-90% and 32.5-34%, respectively. CONCLUSIONS: The admission tourniquet test has low sensitivity and adds relatively little value to the diagnosis of dengue among Lao adult inpatients with suspected dengue. Although a positive tourniquet test suggests dengue and that treatment of alternative diagnoses may not be needed, a negative test result does not exclude dengue.


Assuntos
Dengue/diagnóstico , Torniquetes , Adulto , Algoritmos , Diagnóstico Diferencial , Ensaio de Imunoadsorção Enzimática/métodos , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Esfigmomanômetros , Adulto Jovem
7.
Diagn Microbiol Infect Dis ; 60(1): 43-9, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17889487

RESUMO

We evaluated 2 commercial enzyme-linked immunosorbent assays (ELISAs) for the diagnosis of dengue infection; one a serologic test for immunoglobulin M (IgM) antibodies, the other based on detection of dengue virus nonstructural 1 (NS1) antigen. Using gold standard reference serology on paired sera, 41% (38/92 patients) were dengue confirmed, with 4 (11%) acute primary and 33 (87%) acute secondary infections (1 was of indeterminate status). Sensitivity of the NS1-ELISA was 63% (95% confidence interval [CI], 53-73) on admission samples but was much less sensitive (5%; 95% CI, 1-10) on convalescent samples. The IgM capture ELISA had a lower but statistically equivalent sensitivity compared with the NS1-ELISA for admission samples (45%; 95% CI, 35-55) but was more sensitive on convalescent samples (58%; 95% CI, 48-68). The results of the NS1 and IgM capture ELISAs were combined using a logical OR operator, increasing the sensitivity for admission samples (79%; 95% CI, 71-87), convalescent samples (63%; 95% CI, 53-73), and all samples (71%; 95% CI, 65-78).


Assuntos
Antígenos Virais/sangue , Vírus da Dengue/isolamento & purificação , Dengue/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Proteínas não Estruturais Virais/sangue , Anticorpos Antivirais/sangue , Vírus da Dengue/imunologia , Humanos , Imunoglobulina M/sangue , Laos , Sensibilidade e Especificidade
8.
Clin Vaccine Immunol ; 14(11): 1458-64, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17715330

RESUMO

There is an urgent need for accurate and simple dengue virus infection diagnostic assays in limited-resource settings of dengue endemicity, to assist patient management. Using a panel of reference samples (S. D. Blacksell, P. N. Newton, D. Bell, J. Kelley, M. P. Mammen, D. W. Vaughn, V. Wuthiekanun, A. Sungkakum, A. Nisalak, and N. P. Day, Clin. Infect. Dis. 42:1127-1134, 2006), we recently evaluated eihgt commercially available immunochromatographic rapid diagnostic tests (RDTs) designed to detect dengue virus-specific immunoglobulin M (IgM) and/or IgG. We found that 6/8 RDTs had sensitivities of less than 50% (range, 6 to 65%), but specificities were generally high. Here, in conjuction with dengue virus serotyping by reverse transcriptase PCR and in the limited-resource setting of Laos, where dengue virus is endemic, we evaluated the same eight RDTs against a previously validated dengue IgM/IgG enzyme-linked immunosorbent assay for diagnosis of acute dengue virus infection. Paired serum samples were collected from 87 patients, of whom 38 had confirmed dengue virus infections (4 had primary infections, 33 had secondary infections, and 1 had an infection of indeterminate status). RDT sensitivity was low, with 7/8 RDTs having admission sample sensitivities of less than 20% (range, 4 to 26%). The majority (6/8) of the RDTs, demonstrated high specificity (>95%). Kappa statistic values ranged from 6 to 54% for the RDTs, demonstrating poor to moderate variation between three operators. No RDT adequately differentiated between primary and secondary dengue virus infections. The findings of this study suggest that currently available RDTs based on the detection of IgM antibodies for the diagnosis of acute dengue virus infections are unlikely to be useful for patient management.


Assuntos
Anticorpos Antivirais/sangue , Vírus da Dengue/imunologia , Dengue/diagnóstico , Dengue Grave/diagnóstico , Doença Aguda , Adolescente , Adulto , Anticorpos Antivirais/imunologia , Criança , Dengue/imunologia , Dengue/virologia , Humanos , Laos , Estudos Prospectivos , Sensibilidade e Especificidade , Testes Sorológicos , Dengue Grave/imunologia , Dengue Grave/virologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...