Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 629
Filtrar
3.
Ann Thorac Surg ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38901627

RESUMO

BACKGROUND: Coronary artery occlusion (CO) during transcatheter aortic valve replacement (TAVR) is a devastating complication. The objective is to assess the clinical impact of a novel computational predictive modeling algorithm for CO during TAVR planning. METHODS: From January 2020 to December 2022, 116 patients (7.6%) undergoing TAVR evaluation were deemed at increased risk of CO based on traditional criteria. Patients underwent prospective computational modeling (DASI Simulations) to assess risk of CO during TAVR; procedural modifications and clinical results were reviewed retrospectively. RESULTS: Of the 116 patients at risk for CO by traditional methodology, 53 had native aortic stenosis(45.7%), 47 a previous surgical AVR (40.5%), and 16 a prior TAVR (13.8%). Transcatheter valve choice, size, and/or implantation depth was modeled for all patients. Computational modeling predicted an increased risk of CO based in 39/116 (31.9%). Within this sub-cohort, 29 patients proceeded with TAVR. Procedural modifications to augment risk of CO included BASILICA (n=10), chimney coronary stents (n=8), coronary access without stent (n=3). There were no episodes of coronary compromise among patients following TAVR, either for those predicted to be at high risk of CO (with procedural modifications) or predicted low risk (standard TAVR). CONCLUSIONS: Utilization of preoperative simulations for TAVR in patient-specific geometry through computational predictive modeling of CO was an effective enhancement to procedure planning.

4.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866455

RESUMO

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Idoso , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Estados Unidos/epidemiologia
5.
Am J Cardiol ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38897265

RESUMO

BACKGROUND: Severe tricuspid regurgitation remains largely undertreated given limited treatment options. Transcatheter tricuspid valve interventions have emerged as a promising therapy for these patients, and the TRISCEND II pivotal trial is the first randomized controlled trial to evaluate transcatheter tricuspid valve replacement (TTVR). OBJECTIVES: The TRISCEND II pivotal trial studies the transcatheter EVOQUE tricuspid valve replacement system using an FDA Breakthrough Device Designation - a program intended to provide timely access to medical devices by speeding up development, assessment, and review. METHODS: The TRISCEND II trial is a prospective, multicenter trial that randomizes patients with symptomatic severe tricuspid regurgitation to treatment with either TTVR in conjunction with optimal medical therapy or optimal medical therapy alone. The trial's novel 2-phase design evaluates 30-day safety and 6-month effectiveness endpoints for the first 150 patients in the initial phase and a 1-year safety and effectiveness endpoint for the full cohort of 400 patients in the second phase. RESULTS: The TRISCEND II trial's 2-phase trial design provided an opportunity for early review and led to the first commercial approval of a TTVR system. CONCLUSIONS: The design of the TRISCEND II trial will likely inform future transcatheter tricuspid device trials. CONDENSED ABSTRACT: The TRISCEND II pivotal trial is the first randomized controlled trial of transcatheter tricuspid valve replacement (TTVR). It was designed under the FDA's Breakthrough Device Program to bring a novel TTVR therapy to patients with limited treatment options. A 2-phase design allowed for early review of safety and effectiveness outcomes followed by a full-cohort safety and effectiveness endpoint in the second phase at 1 year. This approach led to approval of the first commercial transcatheter therapy for tricuspid valve replacement.

6.
Innovations (Phila) ; : 15569845241248588, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38721804

RESUMO

OBJECTIVE: Mitral valve repair (MVr) has become the standard therapy for degenerative mitral regurgitation (DMR), but real-world late mortality, reintervention, and readmission data are lacking. This study estimates MVr outcomes for DMR to 3 years in the Medicare fee-for-service population. METHODS: There were 4,219 DMR patients older than 65 years undergoing MVr within the Medicare 100% standard analytic file from October 2015 to December 2018 who were evaluated. Outcomes were analyzed for isolated MVr patients (n = 2,433) and patients undergoing MVr with certain concomitant procedures: MVr + tricuspid valve surgery (TVS; n = 619), MVr + cardiac ablation (CA; n = 540), and MVr + left atrial appendage closure (n = 627). Outcomes over a 3-year period included all-cause mortality, reintervention, rehospitalization, and common complications. All outcomes were modeled with adjustments for patient demographics and comorbid conditions. RESULTS: The average age for all patients was 71.9 ± 5.2 years. Adjusted all-cause mortality and MV reintervention (surgery or transcatheter) at 3 years for the primary cohort of isolated MVr was 3.5% and 1.6%, respectively. Directionally higher mortality at 3 years was observed in patients with concomitant TVS or CA. All-cause readmission and cardiac readmission for isolated MVr was 37.0% and 14.1%, with the highest rates for those with concomitant TVS or CA. Acute kidney injury and stroke/transient ischemic attack were the most common adverse events over 3 years for all patients. CONCLUSIONS: The 3-year mortality and reintervention rates in Medicare patients undergoing degenerative MVr are low. Those undergoing concomitant TVS or CA had directionally higher mortality and cardiac readmission rates. These results help refine outcome benchmarks as new transcatheter MVr procedures continue to emerge.

8.
Ann Biomed Eng ; 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38734846

RESUMO

Patients with bicuspid aortic valve (BAV) commonly have associated aortic stenosis and aortopathy. The geometry of the aortic arch and BAV is not well defined quantitatively, which makes clinical classifications subjective or reliant on limited 2D measurements. The goal of this study was to characterize the 3D geometry of the aortic arch and BAV using objective and quantitative techniques. Pre-TAVR computed tomography angiogram (CTA) in patients with BAV and aortic stenosis (AS) were analyzed (n = 59) by assessing valve commissural angle, presence of a fused region, percent of fusion, and calcium volume. The ascending aorta and aortic arch were reconstructed from patient-specific imaging segmentation to generate a centerline and calculate maximum curvature and maximum area change for the ascending aorta and the descending aorta. Aortic valve commissural angle signified a bimodal distribution suggesting tricuspid-like (≤ 150°, 52.5% of patients) and bicuspid-like (> 150°, 47.5%) morphologies. Tricuspid like was further classified by partial (10.2%) or full (42.4%) fusion, and bicuspid like was further classified into valves with fused region (27.1%) or no fused region (20.3%). Qualitatively, the aortic arch was found to have complex patient-specific variations in its 3D shape with some showing extreme diameter changes and kinks. Quantitatively, subgroups were established using maximum curvature threshold of 0.04 and maximum area change of 30% independently for the ascending and descending aorta. These findings provide insight into the geometric structure of the aortic valve and aortic arch in patients presenting with BAV and AS where 3D characterization allows for quantitative classification of these complex anatomic structures.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38764317

RESUMO

BACKGROUND: Data using real-world assessments of aortic regurgitation (AR) severity to identify rates of Heart Valve Team evaluation and aortic valve replacement (AVR), as well as mortality among untreated patients, are lacking. The present study assessed these trends in care and outcomes for real-world patients with documented AR. METHODS: Using a deidentified data set (January 2018-March 2023) representing 1,002,853 patients >18 years of age from 25 US institutions participating in the egnite Database (egnite, Inc.) with appropriate permissions, patients were classified by AR severity in echocardiographic reports. Rates of evaluation by the Heart Valve Team, AVR, and all-cause mortality without AVR were examined using Kaplan-Meier estimates and compared using the log-rank test. RESULTS: Within the data set, 845,113 patients had AR severity documented. For moderate-to-severe or severe AR, respectively, 2-year rates (95% confidence interval) of evaluation by the Heart Valve Team (43.5% [41.7%-45.3%] and 65.4% [63.3%-67.4%]) and AVR (19.4% [17.6%-21.1%] and 46.5% [44.2%-48.8%]) were low. Mortality at 2 years without AVR increased with greater AR severity, up to 20.7% for severe AR (p < 0.001). In exploratory analyses, 2-year mortality for untreated patients with left ventricular end-systolic dimension index > 25 mm/m2 was similar for moderate (34.3% [29.2%-39.1%]) and severe (37.2% [24.9%-47.5%]) AR. CONCLUSIONS: Moderate or greater AR is associated with poor clinical outcomes among untreated patients at 2 years. Rates of Heart Valve Team evaluation and AVR were low for those with moderate or greater AR, suggesting that earlier referral to the Heart Valve Team could be beneficial.

10.
Ann Thorac Surg ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38723881

RESUMO

BACKGROUND: To provide patients and surgeons with clinically relevant information, The Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database was queried to develop a risk model for isolated tricuspid valve (TV) operations. METHODS: All patients in the STS Adult Cardiac Surgery Database who had undergone isolated TV repair or replacement (N = 13,587; age 48.3 ± 18.4 years) were identified (July 2017 to June 2023). Multivariable logistic regression accounting for TV replacement vs repair was used to model 8 operative outcomes: mortality, morbidity or mortality or both, stroke, renal failure, reoperation, prolonged ventilation, short hospital stay, and prolonged hospital stay. Model discrimination (C-statistic) and calibration were assessed using 9-fold cross-validation. RESULTS: The isolated TV study population included 41.1% repairs (N = 5,583; age 52.6 ± 18.1 years) and 58.9% replacements (N = 8,004; age 45.3 ± 18.0 years). The overall predicted risk of operative mortality was 5.6%, and it was similar in TV repairs and replacements (5.5% and 5.7%, respectively), as was the predicted risk of composite morbidity and mortality (28.2% and 26.8%). TV replacements were generally performed in younger patients with a higher endocarditis prevalence than TV repairs (45.7% vs 21.1%). The model yielded a C-statistic of 0.81 for mortality and 0.76 for the composite of morbidity and mortality, with excellent observed-to-expected calibration that was comparable in all subcohorts and predicted risk decile groups. CONCLUSIONS: An STS risk model has been developed for isolated TV surgery. The current mortality of isolated TV operations is lower than previously observed. This risk prediction model and these contemporary outcomes provide a new benchmark for current and future isolated TV interventions.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38639690

RESUMO

BACKGROUND: Thirty-day outcomes with the investigational Intrepid transapical (TA) transcatheter mitral valve replacement (TMVR) system have previously demonstrated good technical success, but longer-term outcomes in larger cohorts need to be evaluated. OBJECTIVES: The authors sought to evaluate the 2-year safety and performance of the Intrepid TA-TMVR system in patients with symptomatic, ≥moderate-severe mitral regurgitation (MR) and high surgical risk. METHODS: Patient eligibility was determined by local heart teams and approved by a central screening committee. Clinical events were adjudicated by an independent clinical events committee. Echocardiography was evaluated by an independent core laboratory. RESULTS: The cohort included 252 patients that were enrolled at 58 international sites before February 2021 as part of the global Pilot Study (n = 95) or APOLLO trial (primary cohort noneligible + TA roll-ins, n = 157). Mean age was 74.2 years, mean STS-PROM was 6.3%, 60.3% were male, and 80.6% were in NYHA functional class III/IV. Most presented with secondary MR (70.1%), and nearly all had ≥moderate-severe MR (98.4%). All-cause mortality was 13.1% (30-day), 27.3% (1-year), and 36.2% (2-year). The 30-day ≥major bleeding event rate was 22.3%. Heart failure rehospitalization was 9.6% (30-day) and 36.2% (2-year). At 2 years, >50% of patients were alive with improvement in NYHA functional class (82.1%, class I/II), and all patients with available echocardiograms had ≤mild MR. CONCLUSIONS: This analysis represents the largest reported TA-TMVR experience with the longest follow-up in high-risk ≥moderate-severe MR patients. Early mortality and heart failure rehospitalizations were significant, exacerbated by early TA-related bleeding events; however, meaningful improvements in clinical outcomes and marked reductions in MR severity were observed through 2 years.

12.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599690

RESUMO

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Cateterismo Cardíaco/métodos
13.
J Am Coll Cardiol ; 83(17): 1656-1668, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38658105

RESUMO

BACKGROUND: Tricuspid valve annuloplasty (TA) during mitral valve repair (MVr) is associated with increased risk of permanent pacemaker (PPM) implantation, but the magnitude of risk and long-term clinical consequences have not been firmly established. OBJECTIVES: This study assesses the incidence rates of PPM implantation after isolated MVr and following MVr with TA as well as the associated long-term clinical consequences of PPM implantation. METHODS: State-mandated hospital discharge databases of New York and California were queried for patients undergoing MVr (isolated or with concomitant TA) between 2004 and 2019. Patients were stratified by whether or not they received a PPM within 90 days of index surgery. After weighting by propensity score, survival, heart failure hospitalizations (HFHs), endocarditis, stroke, and reoperation were compared between patients with or without PPM. RESULTS: A total of 32,736 patients underwent isolated MVr (n = 28,003) or MVr + TA (n = 4,733). Annual MVr + TA volumes increased throughout the study period (P < 0.001, trend), and PPM rates decreased (P < 0.001, trend). The incidence of PPM implantation <90 days after surgery was 7.7% for MVr and 14.0% for MVr + TA. In 90-day conditional landmark-weighted analyses, PPMs were associated with reduced long-term survival among MVr (HR: 1.96; 95% CI: 1.75-2.19; P < 0.001) and MVr + TA recipients (HR: 1.65; 95% CI: 1.28-2.14; P < 0.001). In both surgical groups, PPMs were also associated with an increased risk of HFH (HR: 1.56; 95% CI: 1.27-1.90; P < 0.001) and endocarditis (HR: 1.95; 95% CI: 1.52-2.51; P < 0.001), but not with stroke or reoperation. CONCLUSIONS: Compared to isolated MVr, adding TA to MVr was associated with a higher risk of 90-day PPM implantation. In both surgical groups, PPM implantation was associated with an increase in mortality, HFH, and endocarditis.


Assuntos
Marca-Passo Artificial , Valva Tricúspide , Humanos , Feminino , Masculino , Idoso , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/cirurgia , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Estudos Retrospectivos , Anuloplastia da Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
15.
Ann Thorac Surg ; 118(1): 155-162, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38580202

RESUMO

BACKGROUND: Reports of cardiac operations after transcatheter aortic valve replacement (TAVR) and early TAVR explantation are increasing. The purpose of this report is to document trends and outcomes of cardiac surgery after initial TAVR. METHODS: The Society of Thoracic Surgeons Adult Cardiac Surgery Database was queried for all adult patients undergoing cardiac surgery after a previously placed TAVR between January 2012 and March 2023. This identified an overall cohort and 2 subcohorts: nonaortic valve operations and surgical aortic valve replacement (SAVR) after previous TAVR. Cohorts were examined with descriptive statistics, trend analyses, and 30-day outcomes. RESULTS: Of 5457 patients who were identified, 2485 (45.5%) underwent non-SAVR cardiac surgery, and 2972 (54.5%) underwent SAVR. The frequency of cardiac surgery after TAVR increased 4235.3% overall and 144.6% per year throughout the study period. The incidence of operative mortality and stroke were 15.5% and 4.5%, respectively. Existing The Society of Thoracic Surgeons risk models performed poorly, because observed-to-expected mortality ratios were significantly >1.0. Among those undergoing SAVR after TAVR, increasing preoperative surgical urgency, age, dialysis, need for SAVR, and concomitant procedures were associated with increased mortality, whereas type of TAVR explant was not. CONCLUSIONS: The need for cardiac surgery, including redo SAVR after TAVR, is increasing rapidly. Risks are higher, and outcomes are worse than predicted. These data should closely inform heart team decisions if TAVR is considered at lowering age and risk profiles in the absence of longitudinal evidence.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Feminino , Masculino , Idoso , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Reoperação/estatística & dados numéricos , Estados Unidos/epidemiologia , Incidência
16.
Ann Thorac Surg ; 2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38522771

RESUMO

BACKGROUND: There is a recognized lack of diversity among patients enrolled in cardiovascular interventional and surgical trials. Diverse patient representation in clinical trials is necessary to enhance generalizability of findings, which may lead to better outcomes across broader populations. The Cardiothoracic Surgical Trials Network (CTSN) recently developed a plan of action to increase diversity among participating investigators and trial participants and is the focus of this review. METHODS: A review of literature and enrollment data from CTSN trials was conducted. RESULTS: CTSN completed more than a dozen major clinical trials (2008-2022), enrolling >4000 patients, of whom 30% were women, 11% were non-White, and 5.6% were Hispanic. CTSN also completed trials of hospitalized patients with coronavirus disease 2019, wherein enrollment was more diverse, with 42% women, and 58% were Asian, Black, Hispanic, or from another underrepresented racial group. The discrepancy in diversity of enrollment between cardiac surgery trials and coronavirus disease trials highlights the need for a more comprehensive understanding of (1) the prevalence of underlying disease requiring cardiac interventions across broad populations, (2) differences in access to care and referral for cardiac surgery, and (3) barriers to enrollment in cardiac surgery trials. CONCLUSIONS: Committed to diversity, CTSN's multifaceted action plan includes developing site-specific enrollment targets, collecting social determinants of health data, understanding reasons for nonparticipation, recruiting sites that serve diverse populations, emphasizing greater diversity among clinical trial teams, and implicit bias training. The CTSN will prospectively assess how these interventions influence enrollment as we work to ensure trial participants are more representative of the communities we serve.

17.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38316377

RESUMO

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Humanos , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Idoso de 80 Anos ou mais , Resultado do Tratamento , Ajuste de Prótese
19.
Arch Cardiol Mex ; 94(2): 219-239, 2024 02 07.
Artigo em Espanhol | MEDLINE | ID: mdl-38325117

RESUMO

This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.


Este consenso de nomenclatura y clasificación para la válvula aórtica bicúspide congénita y su aortopatía está basado en la evidencia y destinado a ser utilizado universalmente por médicos (tanto pediatras como de adultos), médicos ecocardiografistas, especialistas en imágenes avanzadas cardiovasculares, cardiólogos intervencionistas, cirujanos cardiovasculares, patólogos, genetistas e investigadores que abarcan estas áreas de investigación clínica y básica. Siempre y cuando se disponga de nueva investigación clave y de referencia, este consenso internacional puede estar sujeto a cambios de acuerdo con datos basados en la evidencia1.

20.
JTCVS Tech ; 23: 5-17, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38352010

RESUMO

Objective: After transcatheter aortic valve replacement, the mean transvalvular pressure gradient indicates the effectiveness of the therapy. The objective is to develop artificial intelligence to predict the post-transcatheter aortic valve replacement aortic valve pressure gradient and aortic valve area from preprocedural echocardiography and computed tomography data. Methods: A retrospective study was conducted on patients who underwent transcatheter aortic valve replacement due to aortic valve stenosis. A total of 1091 patients were analyzed for pressure gradient predictions (mean age 76.8 ± 9.2 years, 57.8% male), and 1063 patients were analyzed for aortic valve area predictions (mean age 76.7 ± 9.3 years, 57.2% male). An artificial intelligence learning model was trained (training: n = 663 patients, validation: n = 206 patients) and tested (testing: n = 222 patients) to predict pressure gradient, and a separate artificial intelligence learning model was trained (training: n = 640 patients, validation: n = 218 patients) and tested (testing: n = 205 patients) for predicting aortic valve area. Results: The mean absolute error for pressure gradient and aortic valve area predictions was 3.0 mm Hg and 0.45 cm2, respectively. Valve sheath size, body surface area, and age were determined to be the top 3 predictors for pressure gradient, and valve sheath size, left ventricular ejection fraction, and aortic annulus mean diameter were identified to be the top 3 predictors of post-transcatheter aortic valve replacement aortic valve area. A training dataset size of more than 500 patients demonstrated good robustness of the artificial intelligence models for pressure gradient and aortic valve area. Conclusions: The artificial intelligence-based algorithm has demonstrated potential in predicting post-transcatheter aortic valve replacement transvalvular pressure gradient predictions for patients with aortic valve stenosis. Further studies are necessary to differentiate pressure gradient between valve types.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA