Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Fluoresc ; 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795209

RESUMO

Owing to the extreme toxicity and easy synthesis protocol of G-series nerve agents, developing an efficient sensor for selective detection is necessary. Although various traditional methods are utilized to identify these nerve agents, chromo-fluorogenic probes have gained attractive attention from the scientific communities. In the present contribution, we have introduced a new symmetrical aza-substituted chromo-fluorogenic sensor, BPH, for specific detection of sarin gas, one of the fatal G-series nerve agents surrogate, diethylchlorophosphate (DCP). BPH shows a noticeable naked eye colorimetric change from pale yellow to light pink in the presence of DCP, displaying highly intense bright greenish cyan color photoluminosity under a 365 nm UV lamp,which is also manifested from the color chromaticity diagram. A BPH-staining paper stirps-based test kit experiment has been demonstrated for the on-site detection of nerve agent mimics. A more attractive and efficient application of BPH as a sarin gas vapor phase sensor mimics DCP in solid and solution phases. The BPH-based chromo-fluorogenic sensor shows excellent selectivity toward DCP with a detection and quantification limit in the µM range. This report invokes a new way for the researchers to detect DCP employing a simple chromo-fluorogenic sensor, which could be prepared by a time-saving, straightforward, handy protocol from the cost-effective starting materials.

2.
Luminescence ; 39(4): e4731, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38566570

RESUMO

Nerve agents are becoming serious issues for the healthy and sustainable environment of modern civilization. Therefore, its detection and degradation are of paramount importance to the scientific community. In the present contribution, we have introduced a chromo-fluorogenic pyrene-based  probe, (E)-2-methoxy-3-(pyren-1-ylimino)-3,8a-dihydro-2H-chromen-4-ol (PMCO) to detect sarin stimulant diethylchlorophosphate (DCP) in solution and gaseous phases. On inserting DCP in PMCO solution, a visual colorimetric change from yellow to clear colourless in daylight and highly intensified blue fluorescence was observed instantly under a 365 nm portable UV lamp light. PMCO has outstanding selectivity and high sensitivity with a limit of detection of 1.32 µM in dimethyl sulfoxide (DMSO) medium and 77.5 nM in 20% H2O-DMSO. A handy strained paper strip-based experiment was demonstrated to recognize DCP in a mixture of similar toxic analytes. A dip-stick experiment was performed to identify DCP vapour, and may be used as an effective photonic tool. We also demonstrated real sample analysis utilizing different DCP-spiked water samples and validating DCP detection even in various types of soils such as sand, field, and mud. Therefore, this present study provides an effective chemosensor for instant and on-site detection of toxic nerve agents in dangerous circumstances.


Assuntos
Agentes Neurotóxicos , Compostos Organofosforados , Sarina , Sarina/análise , Agentes Neurotóxicos/análise , Corantes Fluorescentes , Dimetil Sulfóxido , Gases
3.
Photochem Photobiol Sci ; 23(4): 763-780, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38519812

RESUMO

Nerve agents are the most notorious substances, which can be fatal to an individual because they block the activity of acetylcholinesterase. Fighting against unpredictable terrorist assaults and wars requires the simple and quick detection of chemical warfare agent vapor. In the present contribution, we have introduced a rhodamine-based chemosensor, BDHA, for the detection of nerve gas-mimicking agents diethylchlorophosphate (DCP) and diethylcyanophosphonate (DCNP) and mustard gas-mimicking agent 2-chloroethyl ethyl sulfide (CEES), both in the liquid and vapor phase. Probe BDHA provides the ability for detection by the naked eye in terms of colorimetric and fluorometric changes. It has been revealed that the interaction between nerve agents mimics and probe BDHA facilitates spirolactam ring opening due to the phosphorylation process. Thus, the highly fluorescent and colored species developed while probe BDHA is colorless and non-fluorescent due to the intramolecular spirolactam ring. Moreover, probe BDHA can effectively recognize DCP, DCNP, and CEES in the µM range despite many toxic analytes and could be identified based on the response times and quantum yield values. Inexpensive, easily carried paper strips-based test kits were developed for the quick, on-location solid and vapor phase detection of these mustard gas imitating agents (CEES) and nerve gas mimicking agents (DCP and DCNP) without needing expensive equipment or skilled personnel. More remarkably, the test strips' color and fluorescence can be rapidly restored, exposing them to triethyl amine (TEA) for cyclic use, suggesting a potential application in the real-time identification of chemical warfare agents. To accomplish the on-location application of BDHA, we have experimented with soil samples to find traces of DCP. Therefore, the chromo-fluorogenic probe BDHA is a promising, instantaneous, and on-the-spot monitoring tool for the selective detection of DCP, DCNP, and CEES in the presence of others.


Assuntos
Substâncias para a Guerra Química , Gás de Mostarda/análogos & derivados , Agentes Neurotóxicos , Nitrofenóis , Organofosfatos , Compostos Organofosforados , Sarina , Agentes Neurotóxicos/química , Acetilcolinesterase , Corantes Fluorescentes/química , Substâncias para a Guerra Química/análise , Substâncias para a Guerra Química/química
4.
J Fluoresc ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38421600

RESUMO

The simplicity of synthesis, significant toxicity of organophosphorus-containing nerve agents, and ease of use of their in-terrorism attacks highlight the necessity to create efficient probes and precise methods for detecting these chemicals. This study developed luminogenic probe 4-(1 H-phenanthrene imidazole-2-yl) benzaldehyde, PB for selectively recognizing lethal chemical sarin mimicking diethylchlorophosphate (DCP) with µM detection limit. Following the addition of DCP to the PB solution, the fluorescence changed from bluish-cyan to green simultaneously; after the insertion of triethylamine (TEA) into the PB-DCP phosphorylated solution, the fluorescence of the original one came back, and it occurred five times. A paper strip-based test kit and dip-stick experiments have been executed to demonstrate the practical applicability of our sensor PB and instant, on-site recognition of the target analyte DCP. An experiment has been investigated using a smartphone and red-green-blue (RGB) color analysis, which offers a novel way for the fast, on-site visual detection and quantification of DCP in actual samples. It also reduces equipment costs, speeds up detection times, and substantially simplifies the operation procedure.

5.
Anal Methods ; 16(9): 1371-1382, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38349024

RESUMO

The high-level toxic effects of organophosphate (OP) nerve agents severely threaten national security and public health. Generating trustworthy, accurate methods for quickly identifying these poisonous chemicals is urgently necessary. In this study, we have presented an azine-based colorimetric sensor (HBD) for the highly sensitive and selective identification of poisonous sarin gas surrogate diethylchlorophosphate (DCP). Our introduced sensor shows a purple color in contact with DCP, which is fully reversible upon the addition of triethylamine (TEA). The detection limit of our sensor for the toxic nerve agent mimic DCP is in the µM range. We have fabricated a test kit to verify the capability of HBD for on-the-spot identification of DCP to execute its practical use. To prove that HBD is an effective chemosensor, dip-stick investigation was conducted to detect DCP in the vaporous stage in the presence of different OPs, inorganic phosphates (IPs), and many other deadly analytes. A cellphone-based display method was also undertaken for on-the-spot recognition and measurement of DCP in isolated regions.


Assuntos
Agentes Neurotóxicos , Sarina , Corantes Fluorescentes , Compostos Organofosforados
6.
Anal Methods ; 16(5): 759-771, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38227020

RESUMO

In this study, an excellent chromo-fluorogenic PMPA probe, (E)-4-(((4-(benzoxazole-2-yl)phenyl)imino)methyl)-N,N-diphenylamine, is introduced for the detection of sarin gas mimic diethyl chlorophosphate (DCP) in solution and gaseous phases. On adding DCP into PMPA solution in a pure DMSO and water-DMSO (4 : 1) medium, it exhibits a hypsochromic shift from yellow to colorless and from no fluorescence to highly intense blue-violet photoluminescence via the formation of a phosphorylated PMPA-DCP product due to the inhibition of intramolecular charge transfer (ICT) and photoinduced electron transfer (PET) mechanism. The sensor could detect DCP in the presence of several other notorious guest analytes with a detection limit in the µM range. Moreover, to accomplish the on-spot detection of DCP and explore the practical applicability of the probe, a paper strip-based test kit, "dip-stick" method, and, more interestingly, a real sample analysis was demonstrated in spiked soil samples.

7.
J Fluoresc ; 2023 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-38158478

RESUMO

Nitroaromatic compounds are illicit explosive chemicals. For environmental security and homeland safety, selective and sensitive identification of these secondary-class explosives has been a reason for the exhaustive research arena of chemists for about a decade. We introduced a sensitive optical sensor with desalted neutral red (NR) dye. After ingressing picric acid (PA) in acetonitrile, the probe becomes non-fluorescent, displaying a colorimetric change from yellow to pink. The quenched phenomena and the changed color were re-established with aliphatic amine, trimethylamine (TEA). The reversibility is produced cyclically, both in fluorimetrically and spectrophotometrically. The detection limit for PA with our probe comes out as 0.639 µM; this value is significantly lower than many chemosensors available in the literature. Also, NR-stained filter paper strips-based test kit analysis has been deployed as a displayable photonic device for in-situ detection of PA. Furthermore, the whole system was conceptualized to produce single input, single output, and double input single output logic gates, which can be applied to digital devices. The chronological input manner as NTP (NR- TEA-PA) pushed us to configure a molecular keypad lock system, the basis of digital locking devices. The repeatable & reversible detection system exhibits "Write read- Erase-read Write-read' type memory devices.

8.
Anal Chim Acta ; 1255: 341111, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37032052

RESUMO

A benzoxazole-based fluorosensor (IMP) has been synthesized and employed for the selective and sensitive detection of sarin surrogate, diethylchlorophosphate (DCP) in solution, and gas phase, respectively. Remarkable turn-on fluorescence is observed due to the introduction of DCP in the solution of IMP because of inhibition of the intramolecular charge transfer process and disruption of the excited state intramolecular proton transfer (ESIPT) mechanism. The synthesized IMP-based fluorescence sensor exhibits excellent selectivity, high sensitivity, and a wide linear range of 15-60 µM with a detection limit of 44 nM. Low-intense to highly intensified visible violet color could be seen by the naked eye under a portable 365 nm UV lamp due to the addition of DCP in the solution of IMP. IMP-stained paper strips-based test kit experiment has been demonstrated to detect traces of DCP in stockpiles of related analytes. A dip-stick experiment for the detection of DCP vapor has also been demonstrated. The effectiveness of IMP in detecting DCP established that it might be used as a signal tool for real sample analysis.

9.
Talanta ; 258: 124448, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36940571

RESUMO

Fast and precise identification of toxic G-series nerve agents in the solution and vapor phase is urgently needed to save human beings from unwanted wars and terrorist attacks, which is challenging to execute practically. In this article, we have designed and synthesized a sensitive and selective phthalimide-based chromo-fluorogenic sensor, DHAI, by a simple condensation process that shows ratiometric and turns on chromo-fluorogenic behavior towards Sarin gas mimic diethylchlorophosphate (DCP) in liquid and vapor phases, respectively. A colorimetric change, from yellow to colorless, is observed in the DHAI solution due to the introduction of DCP in daylight. A remarkable cyan color photoluminescence enhancement is noticed in the presence of DCP in the DHAI solution, which is observable to the naked under a portable 365 nm UV lamp. The mechanistic aspects of the detection of DCP by employing DHAI have been revealed by time-resolved photoluminescence decay analysis and 1H NMR titration investigation. Our probe DHAI exhibits linear photoluminescence enhancement from 0 to 500 µM with a detection limit of nanomolar range from non-aqueous to semi-aqueous media. For practical utility, a DHAI-stained test kit employing Whatman-41 filter paper has been fabricated and used as a portable and displayable photonic device for on-site detection of Sarin gas surrogate, DCP. Also, a dip-stick experiment has been demonstrated to identify the vapor of Sarin gas mimics DCP colorimetrically and fluorometrically. The concentrations of DCP in various water samples have been evaluated with the help of a standard fluorescence curve for real sample analysis.

10.
J Fluoresc ; 33(3): 1027-1039, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36565413

RESUMO

This article highlights the investigation of anion interactions and recognition abilities of naphthalene derivative, [(E)-1-(((4-nitrophenyl)imino)methyl)naphthalen-2-ol], (NIMO) by UV-visible spectroscopically and colorimetrically. NIMO shows selective recognition of F- ions colorimetrically, and a visual color change from yellow to pink is observed by the naked eye. The F- ions recognition is fully reversible in the presence of HSO4- ions. The limit of F- ions detection by NIMO could be possible down to 0.033 ppm-level. A paper strips-based test kit has been demonstrated to detect F- ions selectively by the naked eye, and a smartphone-based method for real sample analysis in the non-aqueous medium has also been demostrated. Spectroscopic behavior is well supported by pKa value calculation and DFT analysis, to find a correlation with receptor analyte interaction. The optical response of NIMO towards the accumulation of F- ions and, subsequently, HSO4- ions as chemical inputs provides an opportunity to construct INH and IMP molecular logic gates.

11.
Spectrochim Acta A Mol Biomol Spectrosc ; 278: 121310, 2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-35561445

RESUMO

This report explores the reversible acidochromism of a benzoxazole-based scaffold (BPP), which is highly sensitive to the acid-base in the liquid and gas phases. With the addition of acid, the solution of BPP changes its color from yellow to pink fuchsia due to the transformation of its imine into quinonoid form. Colour change is completely reversible in the presence of the base, confirming the reversible acidochromic behavior of the present BPP system. Further, a paper strips-based test kit has been demonstrated for the practical utility of the present acidochromic BPP to identify a trace amount of acid-base in solution and gas-phase, respectively. The mechanistic aspect of detection of acid-base and colorimetric change in the presence of acid-base have been explored by density functional theoretical investigations and 1H NMR experiments. Moreover, we have constructed a reconfigurable dual-output combinatorial logic circuit by utilizing the spectral shift between two wavelengths at 404 nm and 552 nm, respectively, and colorimetric change of the BPP in the presence and absence of acid-base.


Assuntos
Benzoxazóis , Lógica , Colorimetria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...