Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 313
Filtrar
1.
Abdom Radiol (NY) ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39167238

RESUMO

PURPOSE: Placental site trophoblastic tumor (PSTT) is a rare form of gestational trophoblastic neoplasm with few previous imaging case reports. We report multiparametric MRI findings in four cases of PSTT with special emphasis on the "pseudo-myometrial thinning" underlying the tumor. METHODS: We reviewed multiparametric MRI and pathologic findings in four cases of PSTT from four institutions. Signal intensity, enhancement pattern, margins, and location of the tumors were evaluated, and myometrial thickness underlying the tumor and normal myometrial thickness contralateral to the tumor were measured on MRI. The myometrial thickness underlying the tumor was also measured in the resected specimen and compared with the myometrial thickness measured on MRI using the Friedman test. RESULTS: All tumors showed heterogeneous signal intensity on T1-weighted imaging, T2-weighted imaging (T2WI), and diffusion-weighted imaging. Three of the four tumors had a hypervascular area on dynamic contrast-enhanced (DCE) MRI. A hypointense rim on T2WI and DCE-MRI was seen in all tumors. All tumors protruded into the uterine cavity to varying degrees and extended into the myometrium close to the serosa. The myometrial thickness underlying the tumor measured on MRI (median thickness, 1.2 mm) was significantly thinner than that measured on pathology (median thickness, 9.5 mm) and normal myometrial thickness contralateral to the tumor on MRI (median thickness, 10.3 mm) (P = 0.02), and there was no significant difference between the latter two. CONCLUSIONS: The thickness of the myometrium underlying the tumor on MRI was approximately one tenth of the thickness on pathology. Thus, the tumors appeared to have almost transmural invasion even when pathologically located within the superficial myometrium. This "pseudo-thinning" of the underlying myometrium and the hypointense rim on MRI could be caused by focal compression of the myometrium by the tumor, possibly due to the fragility of the myometrium at the placental site.

2.
Eur J Radiol ; 179: 111651, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39128249

RESUMO

BACKGROUND: Usual interstitial pneumonia (UIP) cases without honeycombing (possible UIP) included various CT features and was often difficult to diagnose. PURPOSE: This study aimed to classify the cases with possible UIP on CT features using cluster analysis and evaluate the features of subsets of participants and the correlation of prognosis. MATERIALS AND METHODS: The study included 85 patients with possible UIP in the 2011 idiopathic pulmonary fibrosis (IPF) guideline with radiological diagnosis. All cases underwent surgical biopsies and were diagnosed by multidisciplinary discussion (MDD) from the nationwide registry in Japan. The readers evaluated pulmonary opacity, nodules, cysts, and predominant distribution which were reclassified by IPF guidelines in 2018. Additionally, cases were classified into four groups by cluster analysis based on CT findings. The differences in survival among IPF classification and the clusters were evaluated. RESULTS: Cases were diagnosed as IPF (n = 55), NSIP (n = 4), unclassifiable (n = 23), and others (n = 3) by MDD. Cluster analysis revealed 4 clusters by CT features (n = 47, 16, 19 and 3, respectively). Cluster 1 had fewer lesions overall. Cluster 2 have many pure ground-glass opacities and ground-glass opacities with reticulation. Cluster 3 had many reticular opacities and nodules with few lower predominant distributions. Cluster 4 was characterized by peribronchovascular consolidation.The mean survival time of cluster 1 (4518 days) was significantly better than cluster 2, 3, and 4 (1843, 2196, and 1814 days, respectively) (p = 0.03). CONCLUSION: In conclusion, UIP without honeycombing included various CT patterns and MDD diagnoses. Significangly differences in prognosis were observed among clusters classified by CT findings.

3.
Artigo em Inglês | MEDLINE | ID: mdl-39128972

RESUMO

To investigate the effect of heart rate and virtual monoenergetic image (VMI) on coronary stent imaging in dual-source photon-counting detector computed tomography (PCD-CT). A dynamic cardiac phantom was used to vary the heart rate at 50 beats per minute (bpm), 70 bpm, and 90 bpm. Five types of stents (4.0 mm, 3.5 mm, 3.0 mm, 2.75 mm, and 2.5 mm diameter) were scanned at three different locations and reconstructed VMI at 70 keV. In addition, 50% stenosis was assessed for 3.0 mm and 4.0 mm stents. To assess in-stent stenosis, 40 keV, 70 keV, and 100 keV images were compared. Measurable lumen and contrast to noise ratio (CNR) from lumen to stenosis were evaluated quantitatively. A-4-point scale was used for the qualitative image quality of in-stent stenosis. The measurable lumen had no significant differences among heart rates in patent stents (p = 0.55). In-stent stenosis, the residual lumen was significantly larger in 40 keV [27.5% (20.8-32.3%)] than in 70 keV [11.5% (10.0-23.0%), p < 0.05] and 100 keV [0% (0-5.2%), p < 0.05]. The CNR was higher in 40 keV [12.5 (7.5-18.2)] than in 70 keV [5.3 (2.9-7.7), p < 0.05] and 100 keV [1.3 (0.5-2.7), p < 0.05]. The image quality was better in 40 keV (3.4 ± 0.7) than in 70 keV [(2.6 ± 0.8), p < 0.05] and 100 keV [(1.3 ± 0.4), p < 0.05]. Dual-source PCD-CT maintains a measurable lumen even at high heart rates. Adjusting the VMI can be helpful in visualizing the in-stent stenosis.

4.
Sci Rep ; 14(1): 18310, 2024 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-39112802

RESUMO

We examined the association between texture features using three-dimensional (3D) io-dine density histogram on delayed phase of dual-energy CT (DECT) and expression of programmed death-ligand 1 (PD-L1) using immunostaining methods in non-small cell lung cancer. Consecutive 37 patients were scanned by DECT. Unenhanced and enhanced (3 min delay) images were obtained. 3D texture analysis was performed for each nodule to obtain 7 features (max, min, median, mean, standard deviation, skewness, and kurtosis) from iodine density mapping and extracellular volume (ECV). A pathologist evaluated a tumor proportion score (TPS, %) using PD-L1 immunostaining: PD-L1 high (TPS ≥ 50%) and low or negative expression (TPS < 50%). Associations between PD-L1 expression and each 8 parameter were evaluated using logistic regression analysis. The multivariate logistic regression analysis revealed that skewness and ECV were independent indicators associated with high PD-L1 expression (skewness: odds ratio [OR] 7.1 [95% CI 1.1, 45.6], p = 0.039; ECV: OR 6.6 [95% CI 1.1, 38.4], p = 0.037). In the receiver-operating characteristic analysis, the area under the curve of the combination of skewness and ECV was 0.83 (95% CI 0.67, 0.93) with sensitivity of 64% and specificity of 96%. Skewness from 3D iodine density histogram and ECV on dual energy CT were significant factors for predicting PD-L1 expression.


Assuntos
Antígeno B7-H1 , Iodo , Neoplasias Pulmonares , Tomografia Computadorizada por Raios X , Humanos , Antígeno B7-H1/metabolismo , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Idoso , Pessoa de Meia-Idade , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Iodo/metabolismo , Imageamento Tridimensional/métodos , Adenocarcinoma de Pulmão/diagnóstico por imagem , Adenocarcinoma de Pulmão/metabolismo , Adenocarcinoma de Pulmão/patologia , Idoso de 80 Anos ou mais , Curva ROC
5.
Artigo em Inglês | MEDLINE | ID: mdl-39190721

RESUMO

OBJECTIVE: This study aimed to evaluate the feasibility of the recently commercialized reverse encoding distortion correction (RDC) method for echo-planar imaging (EPI) diffusion-weighted imaging (DWI) by applying clinical head MRI. METHODS: This study included 50 consecutive patients who underwent head MRI, including single-shot (SS) EPI DWI and RDC-EPI DWI. For evaluation of normal structures, qualitative scores for image distortion, Dice similarity coefficient (DSC) values, distortion ratios, and mean apparent diffusion coefficient (ADC) values were assessed in the pons, temporal lobe at the skull base, and frontal lobe at the level of the lateral ventricles in 30 patients. To evaluate pathologies, qualitative scores for image distortion were assessed for 25 intracranial and 21 extracranial pathologies identified in 32 patients. RESULTS: Qualitative scores for image distortion, DSC values, distortion ratios, and mean ADC values of the pons and temporal lobe were significantly different between SS-EPI DWI and RDC-EPI DWI, whereas those of the frontal lobe at the level of the lateral ventricles were not significantly different between the 2 DWIs. The qualitative scores for image distortion and mean ADC values of extracranial pathologies were significantly different between the DWIs, whereas those of intracranial pathologies were not significantly different. CONCLUSIONS: RDC-EPI DWI significantly reduced image distortion and showed higher mean ADC values of the brain parenchyma in the skull base and extracranial pathologies.

6.
Eur Radiol ; 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39186105

RESUMO

OBJECTIVES: To create prediction models (PMs) for distinguishing between benign and malignant liver lesions using quantitative data from dual-energy CT (DECT) without contrast agents. MATERIALS AND METHODS: This retrospective study included patients with liver lesions who underwent DECT, including non-contrast-enhanced scans. Benign lesions included hepatic hemangioma, whereas malignant lesions included hepatocellular carcinoma, metastatic liver cancer, and intrahepatic cholangiocellular carcinoma. Patients were divided into derivation and validation groups. In the derivation group, two radiologists calculated ten multiparametric data using univariate and multivariate logistic regression to generate PMs. In the validation group, two additional radiologists measured the parameters to assess the diagnostic performance of PMs. RESULTS: The study included 121 consecutive patients (mean age 67.4 ± 13.8 years, 80 males), with 97 in the derivation group (25 benign and 72 malignant) and 24 in the validation group (7 benign and 17 malignant). Oversampling increased the benign lesion sample to 75, equalizing the malignant group for building PMs. All parameters were statistically significant in univariate analysis (all p < 0.05), leading to the creation of five PMs in multivariate analysis. The area under the curve for the five PMs of two observers was as follows: PM1 (slope K, blood) = 0.76, 0.74; PM2 (slope K, fat) = 0.55, 0.51; PM3 (effective-Z difference, blood) = 0.75, 0.72; PM4 (slope K, blood, fat) = 0.82, 0.78; and PM5 (slope K, effective-Z difference, blood) = 0.90, 0.87. PM5 yielded the best diagnostic performance. CONCLUSION: Multiparametric non-contrast-enhanced DECT is a highly effective method for distinguishing between liver lesions. CLINICAL RELEVANCE STATEMENT: The utilization of non-contrast-enhanced DECT is extremely useful for distinguishing between benign and malignant liver lesions. This approach enables physicians to plan better treatment strategies, alleviating concerns associated with contrast allergy, contrast-induced nephropathy, radiation exposure, and excessive medical expenses. KEY POINTS: Distinguishing benign from malignant liver lesions with non-contrast-enhanced CT would be desirable. This model, incorporating slope K, effective Z, and blood quantification, distinguished benign from malignant liver lesions. Non-contrast-enhanced DECT has benefits, particularly in patients with an iodine allergy, renal failure, or asthma.

7.
Invest Radiol ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39159364

RESUMO

OBJECTIVES: The aim of this study was to compare the performances of photon-counting detector computed tomography (PCD-CT) and energy-integrating detector computed tomography (EID-CT) for visualizing nodules and airways in human cadaveric lungs. MATERIALS AND METHODS: Previously obtained 20 cadaveric lungs were scanned, and images were prospectively acquired by EID-CT and PCD-CT at a radiation dose with a noise level equivalent to the diagnostic reference level. PCD-CT was scanned with ultra-high-resolution mode. The EID-CT images were reconstructed with a 512 matrix, 0.6-mm thickness, and a 350-mm field of view (FOV). The PCD-CT images were reconstructed at 3 settings: PCD-512: same as EID-CT; PCD-1024-FOV350: 1024 matrix, 0.2-mm thickness, 350-mm FOV; and PCD-1024-FOV50: 1024 matrix, 0.2-mm thickness, 50-mm FOV. Two specimens per lung were examined after hematoxylin and eosin staining. The CT images were evaluated for nodules on a 5-point scale and for airways on a 4-point scale to compare the histology. The Wilcoxon signed rank test with Bonferroni correction was performed for statistical analyses. RESULTS: Sixty-seven nodules (1321 µm; interquartile range [IQR], 758-3105 µm) and 92 airways (851 µm; IQR, 514-1337 µm) were evaluated. For nodules and airways, scores decreased in order of PCD-1024-FOV50, PCD-1024-FOV350, PCD-512, and EID-CT. Significant differences were observed between series other than PCD-1024-FOV350 versus PCD-1024-FOV50 for nodules (PCD-1024-FOV350 vs PCD-1024-FOV50, P = 0.063; others P < 0.001) and between series other than EID-CT versus PCD-512 for airways (EID-CT vs PCD-512, P = 0.549; others P < 0.005). On PCD-1024-FOV50, the median size of barely detectable nodules was 604 µm (IQR, 469-756 µm) and that of barely detectable airways was 601 µm (IQR, 489-929 µm). On EID-CT, that of barely detectable nodules was 837 µm (IQR, 678-914 µm) and that of barely detectable airways was 1210 µm (IQR, 674-1435 µm). CONCLUSIONS: PCD-CT visualized small nodules and airways better than EID-CT and improved with high spatial resolution and potentially can detect submillimeter nodules and airways.

8.
Cureus ; 16(6): e63106, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39055458

RESUMO

Background Although some reports have evaluated the safety and efficacy of central venous port (CVP) placement in pediatric patients, the data about the inversion rate of the device and its risk factors are scarce. Therefore, this study aimed to evaluate the inversion rates of CVPs and their associated risk factors in pediatric patients. Methodology Between January 2010 and December 2021, 154 consecutive children (75 boys; median age, 28.5 months; range, 2-71 months) who underwent CVP placement at our center were included in this study. The primary outcome was the CVP inversion rate, and the secondary outcomes included technical success rate, intraoperative complications, and infectious complications. Intraoperative complications were evaluated according to the Society of Interventional Radiology guidelines. Patients under two years old were classified as the younger group and those aged ≥two years as the older group. Results The CVP inversion rate was 4.6% (n = 7/153), equivalent to 0.08 × 1,000 catheter-days. The inversion rate was significantly higher in the younger group (under two years old, 11.2%) than in the older group (≥two years old, 1.0%) according to the univariate analysis (p = 0.00576). The technical success rate was 99.4% (n = 153/154), and mild adverse events were observed during the procedure in three (1.9%) patients. Infectious complications were observed in 16 (10.5%) patients, equivalent to 0.19 × 1,000 catheter-days. Conclusions The CVP inversion rate was significantly higher in younger children (under two years old) than in older children (≥two years old).

9.
Radiol Med ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39043979

RESUMO

OBJECTIVES: To evaluate the ability of 50-keV virtual monoenergetic images (VMI) to depict abdominal arteries in abdominal CT angiography (CTA) compared with 70-keV VMI with photon-counting detector CT (PCD-CT). METHODS: Fifty consecutive patients who underwent multiphase abdominal scans between March and April 2023 were included. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were quantitatively assessed for the abdominal aorta (AA), celiac artery (CeA), superior mesenteric artery (SMA), renal artery (RA), and right hepatic artery (RHA) at both 50- and 70-keV VMI. In addition, 3D images from CTA were analyzed to measure arterial lengths and evaluate the visualization of distal branches. RESULTS: Significantly higher SNR and CNR were observed at 50-keV compared to 70-keV VMI for all arteries: AA (36.54 and 48.28 vs. 25.70 and 28.46), CeA (22.39 and 48.38 vs. 19.09 and 29.15), SMA (23.34 and 49.34 vs. 19.67 and 29.71), RA (22.88 and 48.84 vs. 20.15 and 29.41), and RHA (14.38 and 44.41 vs. 13.45 and 27.18), all p < 0.05. Arterial lengths were also significantly longer at 50-keV: RHA (192.6 vs. 180.3 mm), SMA (230.9 vs. 216.5 mm), and RA (95.9 vs. 92.0 mm), all p < 0.001. CONCLUSION: In abdominal CTA with PCD-CT, 50-keV VMI demonstrated superior quantitative image quality compared to 70-keV VMI. In addition, 50-keV VMI 3D CTA allowed better visualization of abdominal artery branches, highlighting its potential clinical advantage for improved imaging and detailed assessment of abdominal arteries.

10.
Korean J Radiol ; 25(7): 603-612, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38942454

RESUMO

Artificial intelligence (AI) is rapidly gaining recognition in the radiology domain as a greater number of radiologists are becoming AI-literate. However, the adoption and implementation of AI solutions in clinical settings have been slow, with points of contention. A group of AI users comprising mainly clinical radiologists across various Asian countries, including India, Japan, Malaysia, Singapore, Taiwan, Thailand, and Uzbekistan, formed the working group. This study aimed to draft position statements regarding the application and clinical deployment of AI in radiology. The primary aim is to raise awareness among the general public, promote professional interest and discussion, clarify ethical considerations when implementing AI technology, and engage the radiology profession in the ever-changing clinical practice. These position statements highlight pertinent issues that need to be addressed between care providers and care recipients. More importantly, this will help legalize the use of non-human instruments in clinical deployment without compromising ethical considerations, decision-making precision, and clinical professional standards. We base our study on four main principles of medical care-respect for patient autonomy, beneficence, non-maleficence, and justice.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Ásia , Sociedades Médicas
11.
Abdom Radiol (NY) ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888738

RESUMO

Photon-counting CT has a completely different detector mechanism than conventional energy-integrating CT. In the photon-counting detector, X-rays are directly converted into electrons and received as electrical signals. Photon-counting CT provides virtual monochromatic images with a high contrast-to-noise ratio for abdominal CT imaging and may improve the ability to visualize small or low-contrast lesions. In addition, photon-counting CT may offer the possibility of reducing radiation dose. This review provides an overview of the actual clinical operation of photon-counting CT and its diagnostic utility in abdominal imaging. We also describe the clinical implications of photon-counting CT including imaging of hepatocellular carcinoma, liver metastases, hepatic steatosis, pancreatic cancer, intraductal mucinous neoplasm of the pancreas, and thrombus.

12.
Int J Mol Sci ; 25(11)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38891856

RESUMO

Astatine (211At) is a cyclotron-produced alpha emitter with a physical half-life of 7.2 h. In our previous study, the 211At-labeled prostate-specific membrane antigen (PSMA) compound ([211At]PSMA-5) exhibited excellent tumor growth suppression in a xenograft model. We conducted preclinical biodistribution and toxicity studies for the first-in-human clinical trial. [211At]PSMA-5 was administered to both normal male ICR mice (n = 85) and cynomolgus monkeys (n = 2). The mice were divided into four groups for the toxicity study: 5 MBq/kg, 12 MBq/kg, 35 MBq/kg, and vehicle control, with follow-ups at 1 day (n = 10 per group) and 14 days (n = 5 per group). Monkeys were observed 24 h post-administration of [211At]PSMA-5 (9 MBq/kg). Blood tests and histopathological examinations were performed at the end of the observation period. Blood tests in mice indicated no significant myelosuppression or renal dysfunction. However, the monkeys displayed mild leukopenia 24 h post-administration. Despite the high accumulation in the kidneys and thyroid, histological analysis revealed no abnormalities. On day 1, dose-dependent single-cell necrosis/apoptosis was observed in the salivary glands of mice and intestinal tracts of both mice and monkeys. Additionally, tingible body macrophages in the spleen and lymph nodes indicated phagocytosis of apoptotic B lymphocytes. Cortical lymphopenia (2/10) in the thymus and a decrease in the bone marrow cells (9/10) were observed in the 35 MBq/kg group in mice. These changes were transient, with no irreversible toxicity observed in mice 14 days post-administration. This study identified no severe toxicities associated with [211At]PSMA-5, highlighting its potential as a next-generation targeted alpha therapy for prostate cancer. The sustainable production of 211At using a cyclotron supports its applicability for clinical use.


Assuntos
Neoplasias da Próstata , Animais , Humanos , Masculino , Camundongos , Partículas alfa/uso terapêutico , Astato/farmacocinética , Astato/química , Glutamato Carboxipeptidase II/metabolismo , Macaca fascicularis , Camundongos Endogâmicos ICR , Neoplasias da Próstata/patologia , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/metabolismo , Compostos Radiofarmacêuticos/farmacocinética , Compostos Radiofarmacêuticos/química , Distribuição Tecidual
13.
EJNMMI Radiopharm Chem ; 9(1): 29, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619655

RESUMO

BACKGROUND: The alpha emitter astatine-211 (211At) is garnering attention as a novel targeted alpha therapy for patients with refractory thyroid cancer resistant to conventional therapy using beta emitter radioiodine (131I). Herein, we aimed to establish a robust method for the manufacturing and quality control of [211At]NaAt solution for intravenous administration under the good manufacturing practice guidelines for investigational products to conduct an investigator-initiated clinical trial. RESULTS: 211At was separated and purified via dry distillation using irradiated Bi plates containing 211At obtained by the nuclear reaction of 209Bi(4He, 2n)211At. After purification, the 211At trapped in the cold trap was collected in a reaction vessel using 15 mL recovery solution (1% ascorbic acid and 2.3% sodium hydrogen carbonate). After stirring the 211At solution for 1 h inside a closed system, the reaction solution was passed through a sterile 0.22 µm filter placed in a Grade A controlled area and collected in a product vial to prepare the [211At]NaAt solution. According to the 3-lot tests, decay collected radioactivity and radiochemical yield of [211At]NaAt were 78.8 ± 6.0 MBq and 40 ± 3%, respectively. The radiochemical purity of [211At]At- obtained via ion-pair chromatography at the end of synthesis (EOS) was 97 ± 1%, and remained > 96% 6 h after EOS; it was detected at a retention time (RT) 3.2-3.3 min + RT of I-. LC-MS analysis indicated that this principal peak corresponded with an astatide ion (m/z = 210.988046). In gamma-ray spectrometry, the 211At-related peaks were identified (X-ray: 76.9, 79.3, 89.3, 89.8, and 92.3 keV; γ-ray: 569.7 and 687.0 keV), whereas the peak at 245.31 keV derived from 210At was not detected during the 22 h continuous measurement. The target material, Bi, was below the 9 ng/mL detection limit in all lots of the finished product. The pH of the [211At]NaAt solution was 7.9-8.6; the concentration of ascorbic acid was 9-10 mg/mL. Other quality control tests, including endotoxin and sterility tests, confirmed that the [211At]NaAt solution met all quality standards. CONCLUSIONS: We successfully established a stable method of [211At]NaAt solution that can be administered to humans intravenously as an investigational product.

14.
Sci Rep ; 14(1): 8334, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594295

RESUMO

Fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) is widely used for the detection, diagnosis, and clinical decision-making in oncological diseases. However, in daily medical practice, it is often difficult to make clinical decisions because of physiological FDG uptake or cancers with poor FDG uptake. False negative clinical diagnoses of malignant lesions are critical issues that require attention. In this study, Vision Transformer (ViT) was used to automatically classify 18F-FDG PET/CT slices as benign or malignant. This retrospective study included 18F-FDG PET/CT data of 207 (143 malignant and 64 benign) patients from a medical institute to train and test our models. The ViT model achieved an area under the receiver operating characteristic curve (AUC) of 0.90 [95% CI 0.89, 0.91], which was superior to the baseline Convolutional Neural Network (CNN) models (EfficientNet, 0.87 [95% CI 0.86, 0.88], P < 0.001; DenseNet, 0.87 [95% CI 0.86, 0.88], P < 0.001). Even when FDG uptake was low, ViT produced an AUC of 0.81 [95% CI 0.77, 0.85], which was higher than that of the CNN (DenseNet, 0.65 [95% CI 0.59, 0.70], P < 0.001). We demonstrated the clinical value of ViT by showing its sensitive analysis of easy-to-miss cases of oncological diseases.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons/métodos
15.
Jpn J Radiol ; 42(8): 841-851, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38658500

RESUMO

PURPOSE: To investigate the relationship between interstitial lung abnormalities (ILAs) and mortality in patients with esophageal cancer and the cause of mortality. MATERIALS AND METHODS: This retrospective study investigated patients with esophageal cancer from January 2011 to December 2015. ILAs were visually scored on baseline CT using a 3-point scale (0 = non-ILA, 1 = indeterminate for ILA, and 2 = ILA). ILAs were classified into subcategories of non-subpleural, subpleural non-fibrotic, and subpleural fibrotic. Five-year overall survival (OS) was compared between patients with and without ILAs using the multivariable Cox proportional hazards model. Subgroup analyses were performed based on cancer stage and ILA subcategories. The prevalences of treatment complications and death due to esophageal cancer and pneumonia/respiratory failure were analyzed using Fisher's exact test. RESULTS: A total of 478 patients with esophageal cancer (age, 66.8 years ± 8.6 [standard deviation]; 64 women) were evaluated in this study. Among them, 267 patients showed no ILAs, 125 patients were indeterminate for ILAs, and 86 patients showed ILAs. ILAs were a significant factor for shorter OS (hazard ratio [HR] = 1.68, 95% confidence interval [CI] 1.10-2.55, P = 0.016) in the multivariable Cox proportional hazards model adjusting for age, sex, smoking history, clinical stage, and histology. On subgroup analysis using patients with clinical stage IVB, the presence of ILAs was a significant factor (HR = 3.78, 95% CI 1.67-8.54, P = 0.001). Subpleural fibrotic ILAs were significantly associated with shorter OS (HR = 2.22, 95% CI 1.25-3.93, P = 0.006). There was no significant difference in treatment complications. Patients with ILAs showed a higher prevalence of death due to pneumonia/respiratory failure than those without ILAs (non-ILA, 2/95 [2%]; ILA, 5/39 [13%]; P = 0.022). The prevalence of death due to esophageal cancer was similar in patients with and without ILA (non-ILA, 82/95 [86%]; ILA 32/39 [82%]; P = 0.596). CONCLUSION: ILAs were significantly associated with shorter survival in patients with esophageal cancer.


Assuntos
Neoplasias Esofágicas , Doenças Pulmonares Intersticiais , Humanos , Masculino , Feminino , Idoso , Neoplasias Esofágicas/mortalidade , Neoplasias Esofágicas/complicações , Neoplasias Esofágicas/diagnóstico por imagem , Estudos Retrospectivos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Doenças Pulmonares Intersticiais/mortalidade , Doenças Pulmonares Intersticiais/complicações , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade
16.
Comput Biol Med ; 172: 108197, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38452472

RESUMO

BACKGROUND: Health-related patient-reported outcomes (HR-PROs) are crucial for assessing the quality of life among individuals experiencing low back pain. However, manual data entry from paper forms, while convenient for patients, imposes a considerable tallying burden on collectors. In this study, we developed a deep learning (DL) model capable of automatically reading these paper forms. METHODS: We employed the Japanese Orthopaedic Association Back Pain Evaluation Questionnaire, a globally recognized assessment tool for low back pain. The questionnaire comprised 25 low back pain-related multiple-choice questions and three pain-related visual analog scales (VASs). We collected 1305 forms from an academic medical center as the training set, and 483 forms from a community medical center as the test set. The performance of our DL model for multiple-choice questions was evaluated using accuracy as a categorical classification task. The performance for VASs was evaluated using the correlation coefficient and absolute error as regression tasks. RESULT: In external validation, the mean accuracy of the categorical questions was 0.997. When outputs for categorical questions with low probability (threshold: 0.9996) were excluded, the accuracy reached 1.000 for the remaining 65 % of questions. Regarding the VASs, the average of the correlation coefficients was 0.989, with the mean absolute error being 0.25. CONCLUSION: Our DL model demonstrated remarkable accuracy and correlation coefficients when automatic reading paper-based HR-PROs during external validation.


Assuntos
Aprendizado Profundo , Dor Lombar , Ortopedia , Humanos , Dor Lombar/diagnóstico , Dor Lombar/terapia , Qualidade de Vida , Japão , Dor nas Costas , Inquéritos e Questionários
17.
Ann Nucl Med ; 38(5): 329-336, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38548987

RESUMO

Recently, an astatine-labeled prostate-specific membrane antigen (PSMA) ligand ([211At]PSMA-5) has been developed for the targeted alpha therapy of patients with prostate cancer. This manual delineates its physicochemical characteristics to assist healthcare professionals in understanding the α-ray-emitting drug of [211At]PSMA-5 when administered to patients. The safety considerations regarding the handling and use of this drug in clinical trials are outlined, based on the proper usage manual of previous studies. The dose limits, as defined by the guidelines of the International Commission on Radiological Protection (ICRP) and the International Atomic Energy Agency (IAEA), are assessed for patients' caregivers and the general public. According to the calculations provided in this manual, clinical trials involving [211At]PSMA-5 can be safely conducted for these populations even if patients are released after its administration. Moreover, this manual provides comprehensive guidance on the handling of [211At]PSMA-5 for healthcare facilities, and compiles a list of precautionary measures to be distributed among patients and their caregivers. While this manual was created by a research team supported by Ministry of Health, Labour, and Welfare in Japan and approved by Japanese Society of Nuclear Medicine, its applicability extends to healthcare providers in other countries. This manual aims to facilitate conducting clinical trials using [211At]PSMA-5 in patients with prostate cancer.


Assuntos
Neoplasias da Próstata , Compostos Radiofarmacêuticos , Masculino , Humanos , Ligantes , Compostos Radiofarmacêuticos/uso terapêutico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Japão , Antígeno Prostático Específico
18.
Radiographics ; 44(4): e230079, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38547031

RESUMO

The pleura is a thin, smooth, soft-tissue structure that lines the pleural cavity and separates the lungs from the chest wall, consisting of the visceral and parietal pleurae and physiologic pleural fluid. There is a broad spectrum of normal variations and abnormalities in the pleura, including pneumothorax, pleural effusion, and pleural thickening. Pneumothorax is associated with pulmonary diseases and is caused by iatrogenic or traumatic factors. Chest radiography and US help detect pneumothorax with various signs, and CT can also help assess the causes. Pleural effusion occurs in a wide spectrum of diseases, such as heart failure, cirrhosis, asbestos-related diseases, infections, chylothorax, and malignancies. Chest US allows detection of a small pleural effusion and evaluation of echogenicity or septa in pleural effusion. Pleural thickening may manifest as unilateral or bilateral and as focal, multifocal, or diffuse. Various diseases can demonstrate pleural thickening, such as asbestos-related diseases, neoplasms, and systemic diseases. CT, MRI, and fluorodeoxyglucose (FDG) PET/CT can help differentiate between benign and malignant lesions. Knowledge of these features can aid radiologists in suggesting diagnoses and recommending further examinations with other imaging modalities. The authors provide a comprehensive review of the clinical and multimodality imaging findings of pleural diseases and their differential diagnoses. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.


Assuntos
Amianto , Doenças Pleurais , Derrame Pleural , Neoplasias Pleurais , Pneumotórax , Humanos , Diagnóstico Diferencial , Pneumotórax/complicações , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Doenças Pleurais/diagnóstico por imagem , Derrame Pleural/complicações , Neoplasias Pleurais/complicações
19.
Jpn J Radiol ; 42(7): 697-708, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38551771

RESUMO

PURPOSE: To propose a five-point scale for radiology report importance called Report Importance Category (RIC) and to compare the performance of natural language processing (NLP) algorithms in assessing RIC using head computed tomography (CT) reports written in Japanese. MATERIALS AND METHODS: 3728 Japanese head CT reports performed at Osaka University Hospital in 2020 were included. RIC (category 0: no findings, category 1: minor findings, category 2: routine follow-up, category 3: careful follow-up, and category 4: examination or therapy) was established based not only on patient severity but also on the novelty of the information. The manual assessment of RIC for the reports was performed under the consensus of two out of four neuroradiologists. The performance of four NLP models for classifying RIC was compared using fivefold cross-validation: logistic regression, bidirectional long-short-term memory (BiLSTM), general bidirectional encoder representations of transformers (general BERT), and domain-specific BERT (BERT for medical domain). RESULTS: The proportion of each RIC in the whole data set was 15.0%, 26.7%, 44.2%, 7.7%, and 6.4%, respectively. Domain-specific BERT showed the highest accuracy (0.8434 ± 0.0063) in assessing RIC and significantly higher AUC in categories 1 (0.9813 ± 0.0011), 2 (0.9492 ± 0.0045), 3 (0.9637 ± 0.0050), and 4 (0.9548 ± 0.0074) than the other models (p < .05). Analysis using layer-integrated gradients showed that the domain-specific BERT model could detect important words, such as disease names in reports. CONCLUSIONS: Domain-specific BERT has superiority over the other models in assessing our newly proposed criteria called RIC of head CT radiology reports. The accumulation of similar and further studies of has a potential to contribute to medical safety by preventing missed important findings by clinicians.


Assuntos
Processamento de Linguagem Natural , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Japão , Algoritmos , Cabeça/diagnóstico por imagem , Sistemas de Informação em Radiologia , Feminino , Masculino , População do Leste Asiático
20.
Biol Pharm Bull ; 47(2): 532-538, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38417905

RESUMO

Patient derived xenograft (PDX) is a powerful tool to confirm pharmacological efficacy in non-clinical studies for the development of various drugs including anti-cancer agents and therapeutic research. A standardized extract of cultured Lentinula edodes mycelia, a product name AHCC® is produced by Amino Up Co., Ltd. (Sapporo, Japan). In this study, we investigated the inhibitory effect of AHCC® on the growth of tumor PDX in Super SCID (severe combined immunodeficiency) mice. Effects of AHCC® and BCG administration on the growth of renal cancer PDX implanted in Super SCID mice were evaluated by PDX growth curve. Tendency for the effects on the growth of renal cancer PDX in Super SCID by administration of AHCC® and BCG before implanting the PDX were demonstrated. The effects of the oral administration of AHCC® on the growth of renal, invasive and non-invasive breast cancer PDX in Super SCID mice were studied. In Super SCID mice transplanted with renal cancer PDX, AHCC® significantly suppressed tumor proliferation from the day 48 to 83 after transplantation. In two types of breast cancer PDX, tendency of the growth inhibitory effects of AHCC® were shown by PDX growth curve. Significant inhibitory effect was found at only one time point for during proliferation in each PDX. Super SCID-PDX model has the potential to be a useful tool to investigate for the effect of functional foods.


Assuntos
Neoplasias da Mama , Neoplasias Renais , Cogumelos Shiitake , Humanos , Camundongos , Animais , Feminino , Xenoenxertos , Camundongos SCID , Vacina BCG , Neoplasias da Mama/tratamento farmacológico , Neoplasias Renais/tratamento farmacológico , Ensaios Antitumorais Modelo de Xenoenxerto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...