Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
2.
Heart Rhythm ; 19(4): 516-524, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34915187

RESUMO

BACKGROUND: The ganglionated plexuses (GPs) of the intrinsic cardiac autonomic system may play a role in atrial fibrillation (AF). OBJECTIVE: We hypothesized that ablating the ectopy-triggering GPs (ET-GPs) prevents AF. METHODS: GANGLIA-AF (ClinicalTrials.gov identifier NCT02487654) was a prospective, randomized, controlled, 3-center trial. ET-GPs were mapped using high frequency stimulation, delivered within the atrial refractory period and ablated until nonfunctional. If triggered AF became incessant, atrioventricular dissociating GPs were ablated. We compared GP ablation (GPA) without pulmonary vein isolation (PVI) against PVI in patients with paroxysmal AF. Follow-up was for 12 months including 3-monthly 48-hour Holter monitors. The primary end point was documented ≥30 seconds of atrial arrhythmia after a 3-month blanking period. RESULTS: A total of 102 randomized patients were analyzed on a per-protocol basis after GPA (n = 52; 51%) or PVI (n = 50; 49%). Patients who underwent GPA had 89 ± 26 high frequency stimulation sites tested, identifying a median of 18.5% (interquartile range 16%-21%) of GPs. The radiofrequency ablation time was 22.9 ± 9.8 minutes in GPA and 38 ± 14.4 minutes in PVI (P < .0001). The freedom from ≥30 seconds of atrial arrhythmia at 12-month follow-up was 50% (26 of 52) with GPA vs 64% (32 of 50) with PVI (log-rank, P = .09). ET-GPA without atrioventricular dissociating GPA achieved 58% (22 of 38) freedom from the primary end point. There was a significantly higher reduction in antiarrhythmic drug usage postablation after GPA than after PVI (55.5% vs 36%; P = .05). Patients were referred for redo ablation procedures in 31% (16 of 52) after GPA and 24% (12 of 50) after PVI (P = .53). CONCLUSION: GPA did not prevent atrial arrhythmias more than PVI. However, less radiofrequency ablation was delivered to achieve a higher reduction in antiarrhythmic drug usage with GPA than with PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Gânglios/cirurgia , Átrios do Coração , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
Europace ; 23(7): 1003-1015, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33822029

RESUMO

AIMS: TeleCheck-AF is a multicentre international project initiated to maintain care delivery for patients with atrial fibrillation (AF) during COVID-19 through teleconsultations supported by an on-demand photoplethysmography-based heart rate and rhythm monitoring app (FibriCheck®). We describe the characteristics, inclusion rates, and experiences from participating centres according the TeleCheck-AF infrastructure as well as characteristics and experiences from recruited patients. METHODS AND RESULTS: Three surveys exploring centre characteristics (n = 25), centre experiences (n = 23), and patient experiences (n = 826) were completed. Self-reported patient characteristics were obtained from the app. Most centres were academic (64%) and specialized public cardiology/district hospitals (36%). Majority of the centres had AF outpatient clinics (64%) and only 36% had AF ablation clinics. The time required to start patient inclusion and total number of included patients in the project was comparable for centres experienced (56%) or inexperienced in mHealth use. Within 28 weeks, 1930 AF patients were recruited, mainly for remote AF control (31% of patients) and AF ablation follow-up (42%). Average inclusion rate was highest during the lockdown restrictions and reached a steady state at a lower level after easing the restrictions (188 vs. 52 weekly recruited patients). Majority (>80%) of the centres reported no problems during the implementation of the TeleCheck-AF approach. Recruited patients [median age 64 (55-71), 62% male] agreed that the FibriCheck® app was easy to use (94%). CONCLUSION: Despite different health care settings and mobile health experiences, the TeleCheck-AF approach could be set up within an extremely short time and easily used in different European centres during COVID-19.


Assuntos
Fibrilação Atrial , COVID-19 , Aplicativos Móveis , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Controle de Doenças Transmissíveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Avaliação de Resultados da Assistência ao Paciente , SARS-CoV-2
4.
J Cardiovasc Electrophysiol ; 32(4): 994-1004, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33570226

RESUMO

BACKGROUND: During automated radiofrequency (RF) annotation-guided pulmonary vein isolation (PVI), respiratory motion adjustment (RMA) is recommended, yet lacks in vivo validation. METHODS: Following contact force (CF) PVI (continuous RF, 30 W) using general anesthesia and automated RF annotation-guidance (VISITAG™: force-over-time 100% minimum 1 g; 2 mm position stability; ACCURESP™ RMA "off") in 25 patients, we retrospectively examined RMA settings "on" versus "off" at the left atrial posterior wall (LAPW). RESULTS: Respiratory motion detection occurred in eight, permitting offline retrospective comparison of RMA settings. Significant differences in LAPW RF auto-annotation occurred according to RMA setting, with curves displaying catheter position, CF and impedance data indicating "best-fit" for catheter motion detection using RMA "off." Comparing RMA "on" versus "off," respectively: total annotated sites, 82 versus 98; median RF duration per-site, 13.3 versus 10.6 s (p < 0.0001); median force time integral 177 versus 130 gs (p = 0.0002); mean inter-tag distance (ITD), 6.0 versus 4.8 mm (p = 0.002). Considering LAPW annotated site 1-to-2 transitions resulting from deliberate catheter movement, 3 concurrent with inadvertent 0 g CF demonstrated < 0.6 s difference in RF duration. However, 13 deliberate catheter movements during constant tissue contact (ITD range: 2.1-7.0 mm) demonstrated (mean) site-1 RF duration difference 3.7 s (range: -1.3 to 11.3 s): considering multiple measures of catheter position instability, the appropriate indication of deliberate catheter motion occurred with RMA "off" in all. CONCLUSIONS: ACCURESP™ respiratory motion adjustment importantly delayed the identification of deliberate and clinically relevant catheter motion during LAPW RF delivery, rendering auto-annotated RF display invalid. Operators seeking greater accuracy during auto-annotated RF delivery should avoid RMA use.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
7.
Pacing Clin Electrophysiol ; 42(7): 922-929, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31127636

RESUMO

BACKGROUND: To assess occurrence of a histologically validated measure of transmural (TM) atrial ablation-pure R unipolar electrogram (UE) morphology change-at first-ablated left atrial posterior wall (LAPW) sites during contact force (CF)-guided pulmonary vein isolation (PVI). METHODS: Objectively annotated VISITAG™ Module and CARTOREPLAY™ (Biosense Webster Inc., Diamond Bar, CA, USA) UE morphology data were retrospectively analyzed in 23 consecutive patients undergoing PVI under general anesthesia. RESULTS: PVI without spontaneous/dormant recovery was achieved in all, employing 16.3 (3.2) min of radiofrequency (RF; 30 W) energy. All first-ablated LAPW sites demonstrated RS UE morphology preablation, with RF-induced pure R UE morphology change in 98%. Time to pure R UE morphology was significantly shorter at left-sided LAPW sites (4.9 [2.1] vs 6.7 [2.5] s; P = .02), with significantly greater impedance drop (median 13.5 vs 9.9 Ω; P = .003). Importantly, neither first-site RF duration (14.9 vs 15.0 s) nor maximum ablation catheter tip distance moved (during RF) was significantly different, yet the mean CF was significantly higher at right-sided sites (16.5 vs 11.2 g; P = .002). Concurrent impedance and objectively annotated bipolar electrogram (BE) data demonstrated ∼6-8 Ω impedance drop and ∼30% BE decrease at the time of first pure R UE morphology change. CONCLUSIONS: Using objective ablation site annotation, UE morphology evidence of TM RF effect was demonstrated far sooner than considered biologically possible according to the "conventional" 20-40 s RF per-site approach, with significantly greater ablative effect evident at left-sided sites. This novel methodology represents a scientifically more rigorous foundation toward future research into the biological effects of RF ablation in vivo.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Veias Pulmonares/cirurgia , Feminino , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
8.
Heart Lung Circ ; 28(3): 389-396, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29501465

RESUMO

BACKGROUND: A reduction in surface electrocardiogram (ECG) P wave duration and dispersion is associated with improved outcomes in atrial fibrillation ablation. We investigated the effects of different ablation strategies on P wave duration and dispersion, hypothesising that extensive left atrial (LA) ablation with left atrial posterior wall isolation would give a greater reduction in P wave duration than more limited ablation techniques. METHODS: A retrospective analysis of ECGs from patients who have undergone atrial fibrillation (AF) ablation was performed and pre-procedural sinus rhythm ECGs were compared with the post procedure ECGs. Maximal P wave duration was measured in leads I or II, minimum P wave duration in any lead and values were calculated for P wave duration and dispersion. Left atrial dimensions and medications at the time of ECG were documented. Ablation strategies compared were; pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) and the persistent AF (PsAF) ablation strategies of pulmonary vein isolation plus additional linear lesions (Lines), left atrial posterior wall isolation via catheter (PWI) and left atrial posterior wall isolation via staged surgical and catheter ablation (Hybrid). RESULTS: Sixty-nine patients' ECGs were analysed: 19 PVI, 21 Lines, 14 PWI, 15 Hybrid. Little correlation was seen between pre-procedure left atrial size and P wave duration (r=0.24) but LA size and P wave duration was larger in PsAF patients. A significant difference was seen in P wave reduction driven by Hybrid AF ablation (p<0.005) and Lines (<0.02). There was no difference amongst P wave dispersion between groups but the largest reduction was seen in the Hybrid ablation group. CONCLUSIONS: P wave duration increased with duration of continuous atrial fibrillation. Hybrid AF ablation significantly reduced P wave duration and dispersion compared to other ablation strategies including posterior wall isolation via catheter despite this being the same lesion set.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Curva ROC , Estudos Retrospectivos , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 29(12): 1624-1634, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30168232

RESUMO

INTRODUCTION: The ganglionated plexuses (GPs) of the intrinsic cardiac autonomic system are implicated in arrhythmogenesis. GP localization by stimulation of the epicardial fat pads to produce atrioventricular dissociating (AVD) effects is well described. We determined the anatomical distribution of the left atrial GPs that influence atrioventricular (AV) dissociation. METHODS AND RESULTS: High frequency stimulation was delivered through a Smart-Touch catheter in the left atrium of patients undergoing atrial fibrillation (AF) ablation. Three dimensional locations of points tested throughout the entire chamber were recorded on the CARTO™ system. Impact on the AV conduction was categorized as ventricular asystole, bradycardia, or no effect. CARTO maps were exported, registered, and transformed onto a reference left atrial geometry using a custom software, enabling data from multiple patients to be overlaid. In 28 patients, 2108 locations were tested and 283 sites (13%) demonstrated (AVD-GP) effects. There were 10 AVD-GPs (interquartile range, 11.5) per patient. Eighty percent (226) produced asystole and 20% (57) showed bradycardia. The distribution of the two groups was very similar. Highest probability of AVD-GPs (>20%) was identified in: inferoseptal portion (41%) and right inferior pulmonary vein base (30%) of the posterior wall, right superior pulmonary vein antrum (31%). CONCLUSION: It is feasible to map the entire left atrium for AVD-GPs before AF ablation. Aggregated data from multiple patients, producing a distribution probability atlas of AVD-GPs, identified three regions with a higher likelihood for finding AVD-GPs and these matched the histological descriptions. This approach could be used to better characterize the autonomic network.


Assuntos
Atlas como Assunto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Gânglios Autônomos/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Idoso , Ablação por Cateter/métodos , Feminino , Gânglios Autônomos/anatomia & histologia , Átrios do Coração/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade
11.
Europace ; 15(6): 813-9, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23365069

RESUMO

AIMS: Absolute risk reduction (ARR) and number needed to treat (NNT) are considered by many to be the most appropriate figures to use for the informed consent process, yet the results of published implantable cardioverter defibrillators (ICD) trials are frequently presented as relative risk reduction or odds ratio. The period over which risk reduction is calculated also varies between trials, making comparison difficult. METHODS AND RESULTS: Published ICD trials used to formulate national and international guidelines were examined for 1, 2, and 3 year total mortality in ICD and medically treated patients. The number of patients enrolled and at risk at these time points were also sought. Where the raw data were not included in the original text, estimates were taken from published Kaplan-Meier graphs. Eight primary prevention (PP) trials, three secondary prevention (SP) trials, and one SP meta-analyses were included. For PP, ARR at 3-year follow-up ranged from 0 (no benefit) to 24.6% (NNT = 4). For SP, ARR at 3-year follow up ranged from 3.7% (NNT = 27) to 11.3% (NNT = 9). Absolute risk reduction increased with follow-up in PP trials, whereas there was considerable variation in SP trials. Overall, very few trial patients received 3-year follow-up, giving wide confidence intervals (CIs). CONCLUSION: Absolute risk reduction from ICD trials varies significantly depending upon trial entry criteria, subgroup characteristics, and duration of follow-up. The relatively small number of patients followed for 2 or more years leads to wide CIs. Despite these limitations, the standardized ARR and NNT data presented may give a more individualized estimate of risk/benefit that could potentially aid an informed consent process.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/mortalidade , Medicina Baseada em Evidências , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Prevenção Primária/estatística & dados numéricos , Prevenção Secundária/estatística & dados numéricos , Idoso , Ensaios Clínicos como Assunto , Cardioversão Elétrica/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Comportamento de Redução do Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
12.
Pacing Clin Electrophysiol ; 35(10): 1248-52, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22924789

RESUMO

BACKGROUND: Coronary sinus (CS) lead placement for cardiac resynchronization therapy has a failure rate of ∼5-10%. Here we describe a way of implanting an endocardial left ventricular (LV) lead via a transseptal puncture (TSP), using a GooseNeck snare and active fixation lead. METHODS: Three male patients (67-83 years) with failed or extracted epicardial LV leads implanted via the CS had an endocardial LV lead implanted. TSP was performed via a femoral vein. The active fixation pacing lead was advanced to the right atrium from a subclavian vein. A GooseNeck snare was passed via the TSP sheath and used to grasp the tip of the pacing lead. The sheath, GooseNeck snare, and pacing lead tip were then passed to the left atrium by sliding the system up the TSP guidewire and across the interatrial septum before deflecting the lead to permit implantation in the left ventricle. RESULTS: Successful implantation was performed in all patients with an LV implant time of 25-55 minutes. CONCLUSION: The use of a GooseNeck snare via a deflectable transseptal sheath represents a reliable alternative method for endocardial LV lead placement in patients with failed CS LV lead implantation.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Idoso , Idoso de 80 Anos ou mais , Fluoroscopia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Duração da Cirurgia , Veia Subclávia/diagnóstico por imagem , Veia Subclávia/cirurgia , Resultado do Tratamento
13.
Pacing Clin Electrophysiol ; 34(9): e82-4, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20546153

RESUMO

Blocked superior vena cava (SVC) presents a well-recognized problem for the implantation of device leads. Implantable cardioverter defibrillator (ICD) leads pose a greater challenge than the pacing leads by requiring an adequate shock vector for successful defibrillation. We present here a novel technique of opening the blocked SVC to facilitate ICD lead implantation through the upper venous system.


Assuntos
Cateterismo/métodos , Desfibriladores Implantáveis , Síndrome da Veia Cava Superior/terapia , Idoso , Cateterismo/instrumentação , Humanos , Masculino , Radiografia , Síndrome da Veia Cava Superior/diagnóstico por imagem , Resultado do Tratamento
14.
Diabetes ; 59(2): 509-18, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19934008

RESUMO

OBJECTIVE: The objectives of the study were to evaluate retrograde axonal transport of vascular endothelial growth factor A (VEGF-A) protein to sensory neurons after intramuscular administration of an engineered zinc finger protein activator of endogenous VEGF-A (VZ+434) in an experimental model of diabetes, and to characterize the VEGF-A target neurons. RESEARCH DESIGN AND METHODS: We compared the expression of VEGF-A in lumbar (L)4/5 dorsal root ganglia (DRG) of control rats and VZ+434-treated and untreated streptozotocin (STZ)-induced diabetic rats. In addition, axonal transport of VEGF-A, activation of signal transduction pathways in the DRG, and mechanical sensitivity were assessed. RESULTS: VEGF-A immunoreactivity (IR) was detected in small- to medium-diameter neurons in DRG of control rats. Fewer VEGF-A-IR neurons were observed in DRG from STZ-induced diabetic rats; this decrease was confirmed and quantified by Western blotting. VZ+434 administration resulted in a significant increase in VEGF-A protein expression in ipsilateral DRG, 24 h after injection. VEGF-A was axonally transported to the DRG via the sciatic nerve. VZ+434 administration resulted in significant activation of AKT in the ipsilateral DRG by 48 h that was sustained for 1 week after injection. VZ+434 protected against mechanical allodynia 8 weeks after STZ injection. CONCLUSIONS: Intramuscular administration of VZ+434 increases VEGF-A protein levels in L4/5 DRG, correcting the deficit observed after induction of diabetes, and protects against mechanical allodynia. Elevated VEGF-A levels result from retrograde axonal transport and are associated with altered signal transduction, via the phosphatidylinositol 3'-kinase pathway. These data support a neuroprotective role for VEGF-A in the therapeutic actions of VZ+434 and suggest a mechanism by which VEGF-A exerts this activity.


Assuntos
Diabetes Mellitus Experimental/fisiopatologia , Gânglios Espinais/fisiopatologia , Células Receptoras Sensoriais/fisiologia , Fator A de Crescimento do Endotélio Vascular/fisiologia , Dedos de Zinco/fisiologia , Animais , Glicemia/metabolismo , Peso Corporal , Regulação para Baixo , Lateralidade Funcional , Engenharia Genética , Aumento da Imagem , Imuno-Histoquímica , Masculino , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/fisiopatologia , Neurônios/fisiologia , Fenótipo , Ratos , Ratos Wistar , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Fator A de Crescimento do Endotélio Vascular/deficiência , Fator A de Crescimento do Endotélio Vascular/genética , Dedos de Zinco/genética
15.
Diabetes ; 58(12): 2893-903, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19720799

RESUMO

OBJECTIVE: The goal of this study was to characterize glycation adducts formed in both in vivo extracellular matrix (ECM) proteins of endoneurium from streptozotocin (STZ)-induced diabetic rats and in vitro by glycation of laminin and fibronectin with methylglyoxal and glucose. We also investigated the impact of advanced glycation end product (AGE) residue content of ECM on neurite outgrowth from sensory neurons. RESEARCH DESIGN AND METHODS: Glycation, oxidation, and nitration adducts of ECM proteins extracted from the endoneurium of control and STZ-induced diabetic rat sciatic nerve (3-24 weeks post-STZ) and of laminin and fibronectin that had been glycated using glucose or methylglyoxal were examined by liquid chromatography with tandem mass spectrometry. Methylglyoxal-glycated or unmodified ECM proteins were used as substrata for dissociated rat sensory neurons as in vitro models of regeneration. RESULTS: STZ-induced diabetes produced a significant increase in early glycation N(epsilon)-fructosyl-lysine and AGE residue contents of endoneurial ECM. Glycation of laminin and fibronectin by methylglyoxal and glucose increased glycation adduct residue contents with methylglyoxal-derived hydroimidazolone and N(epsilon)-fructosyl-lysine, respectively, of greatest quantitative importance. Glycation of laminin caused a significant decrease in both neurotrophin-stimulated and preconditioned sensory neurite outgrowth. This decrease was prevented by aminoguanidine. Glycation of fibronectin also decreased preconditioned neurite outgrowth, which was prevented by aminoguanidine and nerve growth factor. CONCLUSIONS: Early glycation and AGE residue content of endoneurial ECM proteins increase markedly in STZ-induced diabetes. Glycation of laminin and fibronectin causes a reduction in neurotrophin-stimulated neurite outgrowth and preconditioned neurite outgrowth. This may provide a mechanism for the failure of collateral sprouting and axonal regeneration in diabetic neuropathy.


Assuntos
Proteínas da Matriz Extracelular/metabolismo , Produtos Finais de Glicação Avançada/metabolismo , Regeneração Nervosa , Nervo Isquiático/fisiopatologia , Células Receptoras Sensoriais , Animais , Cromatografia Líquida , Diabetes Mellitus Experimental , Inibidores Enzimáticos/farmacologia , Fibronectinas/metabolismo , Guanidinas/farmacologia , Laminina/metabolismo , Regeneração Nervosa/efeitos dos fármacos , Neuritos/metabolismo , Ratos , Células Receptoras Sensoriais/metabolismo , Espectrometria de Massas em Tandem
16.
Europace ; 11(5): 638-42, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19174376

RESUMO

AIMS: Patients with left ventricular systolic dysfunction and electrocardiographic QRS duration (QRSd) >or=120 ms may obtain symptomatic and prognostic benefits from cardiac resynchronization therapy (CRT). However, clinical trials do not describe the methods used to measure QRSd. We investigated the effect of electrocardiogram (ECG) display format and paper speed on the accuracy of manual QRSd assessment and concordance of manual QRSd with computer-calculated mean and maximal QRSd. METHODS AND RESULTS: Six cardiologists undertook QRSd measurements on ECGs, with computer-calculated mean QRSd close to 120 ms. Display formats were 12-lead, 6-limb, and 6-precordial leads, each at 25 and 50 mm/s. When the computer-calculated mean was used to define QRSd, manual assessment demonstrated 97 and 83% concordance at categorizing QRSd as < and >or=120 ms, respectively. Using the computer-calculated maximal QRSd, manual assessment demonstrated 83% concordance when QRSd was <120 ms and 19% concordance when QRSd was >or=120 ms. The six-precordial lead format demonstrated significantly less intra and inter-observer variabilities than the 12-lead, but this did not improve concordance rates. CONCLUSION: Manual QRSd assessments demonstrate significant variability, and concordance with computer-calculated measurement depends on whether QRSd is defined as the mean or maximal value. Consensus is required both on the most appropriate definition of QRSd and its measurement.


Assuntos
Desfibriladores Implantáveis , Eletrocardiografia , Marca-Passo Artificial , Seleção de Pacientes , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Algoritmos , Diagnóstico por Computador/métodos , Humanos , Variações Dependentes do Observador , Prognóstico , Disfunção Ventricular Esquerda/diagnóstico
17.
Pacing Clin Electrophysiol ; 31(12): 1606-11, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19067814

RESUMO

BACKGROUND: Patients undergoing catheter ablation for atrial fibrillation (AF) frequently require redo procedures, but there are no data reporting interatrial septum thickness (IAS) and difficulty during repeat transseptal puncture (TSP). METHODS: Patients undergoing two separate AF ablation procedures had preprocedural fossa ovalis (FO) thickness measured using transesophageal echocardiography (TEE). "Difficult" TSP was defined by two observers as requiring excessive force, or conversion to TEE guidance. RESULTS: The study comprised 42 patients (37 male) with mean+/-SD age 55+/-9 years. Mean FO thickness was significantly greater at the time of redo TSP (2.2+/-1.6 mm vs 2.6+/-1.5 mm at redo, P=0.03); however, this finding was limited to those who underwent initial dual transseptal sheath procedures, FO thickness 2.0+/-1.5 mm and 2.5+/-1.4 mm for TEE 1 and 2, respectively (P=0.048). There was a trend for more frequent difficult redo TSP procedures, 7/42 (17%; 95% confidence interval [CI] 8-31) redo, versus 4/42 (10%; 95% CI 3-23) first TSP. On univariate analysis, FO thickness was not predictive of TSP difficulty; the only predictor of difficult redo TSP was diabetes. CONCLUSIONS: IAS thickness at the FO increased following catheter ablation of AF, yet on subgroup analysis this was limited to initial procedures utilizing dual transseptal sheaths. There was a trend toward more frequent difficulty during redo TSP, yet this was not associated with FO thickening. Diabetes may predispose to difficulty during redo TSP; this finding requires confirmation in a larger study population.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Punções/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/métodos , Resultado do Tratamento , Ultrassonografia
18.
J Peripher Nerv Syst ; 13(2): 112-21, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18601656

RESUMO

This review examines the putative role of glucose in the etiology of diabetic neuropathies. Excessive glucose generates several secondary metabolic anomalies - principally oxidative stress (via both the polyol pathway and glucoxidation) and non-enzymic glycation of macromolecules. The latter is also facilitated by glucoxidation. These metabolic deviations trigger cellular responses that are inappropriate to normal function. Principal among these are neurotrophic deficits and phosphorylation of mitogen-activated protein kinases (MAPK). Downstream of these events are aberrant ion channel function and disordered gene expression, leading to changes in cellular phenotype. This leads directly to disordered nerve conduction, a recognised early clinical sign, and indirectly, via as yet undisclosed links, to sensory loss and axonopathy. Recent work also links MAPK activation to the development of neuropathic pain.


Assuntos
Neuropatias Diabéticas/etiologia , Neuropatias Diabéticas/metabolismo , Animais , Neuropatias Diabéticas/enzimologia , Neuropatias Diabéticas/fisiopatologia , Glucose/metabolismo , Humanos , Insulina/metabolismo , Sistema de Sinalização das MAP Quinases/fisiologia , Estresse Oxidativo/fisiologia
19.
Heart Lung Circ ; 17(3): 173-85, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18222726

RESUMO

Detecting viable myocardium, whether hibernating or stunned, is of clinical significance in patients with coronary artery disease and left ventricular dysfunction. Echocardiographic assessments of myocardial thickening and endocardial excursion during dobutamine infusion provide a highly specific marker for myocardial viability, but with relatively less sensitivity. The additional modalities of myocardial contrast echocardiography and tissue Doppler have recently been proposed to provide further, quantitative measures of myocardial viability assessment. Cardiac magnetic resonance (CMR) has become popular for the assessment of myocardial viability as it can assess cardiac function, volumes, myocardial scar, and perfusion with high-spatial resolution. Both 'delayed enhancement' CMR and dobutamine stress CMR have important roles in the assessment of patients with ischaemic cardiomyopathy. This article reviews the recent advances in both echocardiography and CMR for the clinical assessment of myocardial viability. It attempts to provide a pragmatic approach toward the patient-specific assessment of this important clinical problem.


Assuntos
Ecocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/patologia , Humanos , Sensibilidade e Especificidade
20.
Nat Rev Neurosci ; 9(1): 36-45, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18094705

RESUMO

Neurons have a constantly high glucose demand, and unlike muscle cells they cannot accommodate episodic glucose uptake under the influence of insulin. Neuronal glucose uptake depends on the extracellular concentration of glucose, and cellular damage can ensue after persistent episodes of hyperglycaemia--a phenomenon referred to as glucose neurotoxicity. This article reviews the pathophysiological manifestation of raised glucose in neurons and how this can explain the major components of diabetic neuropathy.


Assuntos
Hiperglicemia/complicações , Síndromes Neurotóxicas/etiologia , Animais , Neuropatias Diabéticas/etiologia , Líquido Extracelular/metabolismo , Glucose/metabolismo , Humanos , Hiperglicemia/patologia , Neurônios/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...