Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Am Heart J ; 275: 128-137, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38838970

RESUMO

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, P = .33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 P = .46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, P = .04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, P = .02), reduced SVi (34.2 vs 38 mL/m2, P < .01) and transaortic flow rate (190.6 vs 211 mL/s, P < .01). At predischarge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, P < .01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, P = .03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs 44 IQR 35-59 in those without, P = .02)). No evidence of a significant impact of PPM on overall (P = .71) and CV (P = .70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, P = .03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, P < .001) and LVOT diameter (OR 0.79, 0.65-0.95, P = .01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia , Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas/efeitos adversos , Ecocardiografia/métodos , Estenose da Valva Aórtica/cirurgia , Idoso , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ajuste de Prótese
3.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37138103

RESUMO

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Sistema de Registros , Desenho de Prótese
6.
Eur Radiol ; 33(11): 7756-7768, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37166497

RESUMO

OBJECTIVE: To assess the value of opportunistic biomarkers derived from chest CT performed at hospital admission of COVID-19 patients for the phenotypization of high-risk patients. METHODS: In this multicentre retrospective study, 1845 consecutive COVID-19 patients with chest CT performed within 72 h from hospital admission were analysed. Clinical and outcome data were collected by each center 30 and 80 days after hospital admission. Patients with unknown outcomes were excluded. Chest CT was analysed in a single core lab and behind pneumonia CT scores were extracted opportunistic data about atherosclerotic profile (calcium score according to Agatston method), liver steatosis (≤ 40 HU), myosteatosis (paraspinal muscle F < 31.3 HU, M < 37.5 HU), and osteoporosis (D12 bone attenuation < 134 HU). Differences according to treatment and outcome were assessed with ANOVA. Prediction models were obtained using multivariate binary logistic regression and their AUCs were compared with the DeLong test. RESULTS: The final cohort included 1669 patients (age 67.5 [58.5-77.4] yo) mainly men 1105/1669, 66.2%) and with reduced oxygen saturation (92% [88-95%]). Pneumonia severity, high Agatston score, myosteatosis, liver steatosis, and osteoporosis derived from CT were more prevalent in patients with more aggressive treatment, access to ICU, and in-hospital death (always p < 0.05). A multivariable model including clinical and CT variables improved the capability to predict non-critical pneumonia compared to a model including only clinical variables (AUC 0.801 vs 0.789; p = 0.0198) to predict patient death (AUC 0.815 vs 0.800; p = 0.001). CONCLUSION: Opportunistic biomarkers derived from chest CT can improve the characterization of COVID-19 high-risk patients. CLINICAL RELEVANCE STATEMENT: In COVID-19 patients, opportunistic biomarkers of cardiometabolic risk extracted from chest CT improve patient risk stratification. KEY POINTS: • In COVID-19 patients, several information about patient comorbidities can be quantitatively extracted from chest CT, resulting associated with the severity of oxygen treatment, access to ICU, and death. • A prediction model based on multiparametric opportunistic biomarkers derived from chest CT resulted superior to a model including only clinical variables in a large cohort of 1669 patients suffering from SARS- CoV2 infection. • Opportunistic biomarkers of cardiometabolic comorbidities derived from chest CT may improve COVID-19 patients' risk stratification also in absence of detailed clinical data and laboratory tests identifying subclinical and previously unknown conditions.


Assuntos
COVID-19 , Doenças Cardiovasculares , Fígado Gorduroso , Osteoporose , Masculino , Humanos , Idoso , Feminino , Estudos Retrospectivos , SARS-CoV-2 , Mortalidade Hospitalar , Tomografia Computadorizada por Raios X/métodos , Biomarcadores
7.
Eur Heart J Cardiovasc Imaging ; 24(8): 1052-1061, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-36752044

RESUMO

AIMS: The prognostic impact of flow trajectories according to stroke volume index (SVi) and transvalvular flow rate (FR) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) remains poorly assessed. We evaluated and compared SVi and FR prior and after TAVR for severe AS. METHODS AND RESULTS: Patients were categorized according to SVi (<35 mL/m2) and FR (<200 mL/s). The association of pre- and post-TAVR SVi and FR with all-cause mortality up to 3 years was assessed with multivariable Cox regression models. Among 980 patients with pre-TAVR flow assessment, SVi was reduced in 41.3% and FR in 48.1%. Baseline flow status was not an independent mortality predictor [SVi: hazard ratio (HR) 1.22, 95% confidence interval (CI) 0.85-1.82, FR: HR 0.78, 95% CI 0.48-1.27]. Among 731 patients undergoing early (5 days, interquartile range 2-29) post-TAVR flow assessment, SVi recovered in 40.1% and FR in 49.0% patients with baseline low flow. Reduced FR following TAVR was an independent predictor of mortality (HR 1.67, 95% CI 1.02-2.74), whereas SVi was not (HR 0.97, 95% CI 0.53-1.78). Three-year estimated mortality in patients with recovered FR was lower than that in patients with reduced FR (13.3 vs. 37.7% vs, P = 0.003) and similar to that in patients with normal baseline FR (P = 0.317). CONCLUSION: Baseline flow status was not an independent predictor of mid-term mortality among all-comers with severe AS undergoing TAVR. Flow recovery early after TAVR was frequent. Post-TAVR FR, but not SVi, was independently associated with mid-term all-cause mortality. By impacting flow status, AV replacement modifies the association of flow status with outcomes.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
9.
Minerva Cardiol Angiol ; 71(1): 35-43, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35332744

RESUMO

BACKGROUND: The distal radial represents an evolution of the standard radial approach. Distal radial arterial access (DRA) in the so-called "anatomical snuffbox" is technically more difficult but offers potential advantages for patients. Moreover, the use of the distal radial would preserve the proximal radial from the risk of arterial occlusion after interventional procedures performed through the radial artery. METHODS: We enrolled 100 consecutive elective patients undergoing cardiac catheterization (diagnostic or procedural). Arterial access to the distal radial was entirely managed by nursing staff supervised by the interventional cardiologist. In this single-centre single-operator experienced study, the same nurse operator performed puncture, wiring, and sheath advancement. RESULTS: The technical feasibility was 89% and the failure rate occurred in the first 50 cases as evidenced by the learning curve. There were no major complications and the rate of minor complications is in line with that of the radial literature. BMI (OR 1.19; 95% CI: 1.03-1.38), non-radial dominance (OR 3.5; 95% CI: 1.04-12.3) and operator's experience (OR 0.59; 95% CI: 0.35-0.99 for every 20 consecutive cases performed) were associated with DRA failures. CONCLUSIONS: The experience is encouraging and beneficial for all staff and patients with a high percentage of technical success and few mild complications.


Assuntos
Curva de Aprendizado , Intervenção Coronária Percutânea , Humanos , Papel do Profissional de Enfermagem , Artéria Radial/cirurgia , Punho , Intervenção Coronária Percutânea/efeitos adversos
10.
J Clin Med ; 13(1)2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38202217

RESUMO

BACKGROUND: Stent implantation represents the standard of care in coronary intervention. While a short stent implanted on a focal lesion located on the left anterior descending artery (LAD) seems a reasonable alternative to an internal mammary implant, the same for long stents is still debated. METHODS: We reported the long-term data of 531 consecutive patients who underwent Percutaneous Coronary Intervention (PCI) with long stents in two highly specialized centres. The main inclusion criteria were the implantation of stents longer than 30 mm on the LAD and a minimum follow-up (FU) of five years. The primary endpoint was mortality, and the secondary endpoints were any myocardial infarction (MI), target vessel and lesion revascularization (TVR and TLR, respectively), and stent thrombosis (ST) observed as definite, probable, or possible. RESULTS: In this selected population with characteristics of complex PCI (99.1%), the long-term follow-up (mean 92.18 ± 35.5 months) estimates of all-cause death, cardiovascular death, and any myocardial infarction were 18.3%, 10.5%, and 9.3%, respectively. Both all-cause and cardiovascular deaths are significantly associated with three-vessel disease (HR 6.8; confidence of interval (CI) 95% 3.844-11.934; p < 0.001, and HR 4.7; CI 95% 2.265-9.835; p < 0.001, respectively). Target lesion (TLR) and target vessel revascularization (TVR) are associated with the presence of three-lesion disease on the LAD (HR 3.4; CI 95% 1.984-5.781; p < 0.001; HR 3.9 CI 95% 2.323-6.442; p < 0.001, respectively). Re-PCI for any cause occurred in 31.5% of patients and shows an increased risk for three-lesion stenting (HR 4.3; CI 95% 2.873-6.376; p < 0.001) and the treatment of bifurcation with two stents (HR 1.6; 95% CI 1.051-2.414; p = 0.028). Stent thrombosis rate at the 5-year FU was 4.4% (1.3% definite; 0.9% probable; 2.1% possible), including a 1.7% rate of very-late thrombosis. The stent length superior to 40 mm was not associated with poor outcomes (all-cause death p = 0.349; cardiovascular death p = 0.855; MI p = 0.691; re-PCI p = 0.234; TLR p = 0.805; TVR p = 0.087; ST p = 0.189). CONCLUSION: At an FU of longer than five years, patients treated with stents longer than 30 mm in their LAD showed acceptable procedural results but poor outcomes.

11.
Front Cardiovasc Med ; 9: 902564, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36187005

RESUMO

Background: Coronary access after transcatheter aortic valve implantation (TAVI) with supra-annular self-expandable valves may be challenging or un-feasible. There is little data concerning coronary access following transcatheter aortic valve-in-valve implantation (ViV-TAVI) for degenerated surgical bioprosthesis. Aims: To evaluate the feasibility and challenge of coronary access after ViV-TAVI with the supra-annular self-expandable ACURATE neo valve. Materials and methods: Sixteen patients underwent ViV-TAVI with the ACURATE neo valve. Post-procedural computed tomography (CT) was used to create 3D-printed life-sized patient-specific models for bench-testing of coronary cannulation. Primary endpoint was feasibility of diagnostic angiography and PCI. Secondary endpoints included incidence of challenging cannulation for both diagnostic catheters (DC) and guiding catheters (GC). The association between challenging cannulations with aortic and transcatheter/surgical valve geometry was evaluated using pre and post-procedural CT scans. Results: Diagnostic angiography and PCI were feasible for 97 and 95% of models respectively. All non-feasible procedures occurred in ostia that underwent prophylactic "chimney" stenting. DC cannulation was challenging in 17% of models and was associated with a narrower SoV width (30 vs. 35 mm, p < 0.01), STJ width (28 vs. 32 mm, p < 0.05) and shorter STJ height (15 vs. 17 mm, p < 0.05). GC cannulation was challenging in 23% of models and was associated with narrower STJ width (28 vs. 32 mm, p < 0.05), smaller transcatheter-to-coronary distance (5 vs. 9.2 mm, p < 0.05) and a worse coronary-commissural overlap angle (14.3° vs. 25.6 o , p < 0.01). Advanced techniques to achieve GC cannulation were required in 22/64 (34%) of cases. Conclusion: In this exploratory bench analysis, diagnostic angiography and PCI was feasible in almost all cases following ViV-TAVI with the ACURATE neo valve. Prophylactic coronary stenting, higher implantation, narrower aortic sinus dimensions and commissural misalignment were associated with an increased challenge of coronary cannulation.

12.
Radiol Med ; 127(9): 960-972, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36038790

RESUMO

PURPOSE: To develop and validate an effective and user-friendly AI platform based on a few unbiased clinical variables integrated with advanced CT automatic analysis for COVID-19 patients' risk stratification. MATERIAL AND METHODS: In total, 1575 consecutive COVID-19 adults admitted to 16 hospitals during wave 1 (February 16-April 29, 2020), submitted to chest CT within 72 h from admission, were retrospectively enrolled. In total, 107 variables were initially collected; 64 extracted from CT. The outcome was survival. A rigorous AI model selection framework was adopted for models selection and automatic CT data extraction. Model performances were compared in terms of AUC. A web-mobile interface was developed using Microsoft PowerApps environment. The platform was externally validated on 213 COVID-19 adults prospectively enrolled during wave 2 (October 14-December 31, 2020). RESULTS: The final cohort included 1125 patients (292 non-survivors, 26%) and 24 variables. Logistic showed the best performance on the complete set of variables (AUC = 0.839 ± 0.009) as in models including a limited set of 13 and 5 variables (AUC = 0.840 ± 0.0093 and AUC = 0.834 ± 0.007). For non-inferior performance, the 5 variables model (age, sex, saturation, well-aerated lung parenchyma and cardiothoracic vascular calcium) was selected as the final model and the extraction of CT-derived parameters was fully automatized. The fully automatic model showed AUC = 0.842 (95% CI: 0.816-0.867) on wave 1 and was used to build a 0-100 scale risk score (AI-SCoRE). The predictive performance was confirmed on wave 2 (AUC 0.808; 95% CI: 0.7402-0.8766). CONCLUSIONS: AI-SCoRE is an effective and reliable platform for automatic risk stratification of COVID-19 patients based on a few unbiased clinical data and CT automatic analysis.


Assuntos
COVID-19 , Adulto , Inteligência Artificial , Cálcio , Humanos , Estudos Retrospectivos , SARS-CoV-2
15.
Panminerva Med ; 64(4): 427-437, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35638242

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established management strategy for severe aortic valve stenosis. Percutaneous axillary approach for TAVI holds the promise of improving safety without jeopardizing effectiveness in comparison to surgical access. We aimed at appraising the comparative effectiveness of percutaneous vs. surgical axillary approaches for TAVI. METHODS: We performed an international retrospective observational study using de-identified details on baseline, procedural, and 1-month follow-up features. Valve Academic Research Consortium (VARC)-3 criteria were applied throughout. Outcomes of interest were clinical events up to 1 month of follow-up, compared with unadjusted and propensity score-adjusted analyses. RESULTS: A total of 432 patients were included, 189 (43.8%) receiving surgical access, and 243 (56.2%) undergoing percutaneous access. Primary hemostasis failure was more common in the percutaneous group (13.2% vs. 4.2%, P<0.001), leading to more common use of covered stent implantation (13.2% vs. 3.7%, P<0.001). Irrespectively, percutaneous access was associated with shorter hospital stay (-2.6 days [95% confidence interval: -5.0; -0.1], P=0.038), a lower risk of major adverse events (a composite of death, myocardial infarction, stroke, type 3 bleeding, and major access-site related complication; odds ratio=0.44 [0.21; 0.95], P=0.036), major access-site non-vascular complications (odds ratio=0.21 [0.06; 0.77], P=0.018), and brachial plexus impairment (odds ratio=0.16 [0.03; 0.76], P=0.021), and shorter hospital stay (-2.6 days [-5.0; -0.1], P=0.038). CONCLUSIONS: Percutaneous axillary access provides similar or better results than surgical access in patients undergoing TAVI with absolute or relative contraindications to femoral access.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Sistema de Registros , Estudos Retrospectivos , Valva Aórtica/cirurgia , Fatores de Risco
16.
Cardiovasc Revasc Med ; 43: 104-111, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35398008

RESUMO

BACKGROUND: Coronary chronic total occlusion lesions (CTOs) confer an increased risk of arrhythmic events among patients with ischemic cardiomyopathy (ICM) and implantable cardioverter-defibrillator (ICD) carriers, however the impact of CTO recanalization in this population remains unassessed. AIMS: Evaluate the impact of CTOs percutaneous coronary interventions (PCI) on arrhythmic events. METHODS: Patients with ICM and ICD from the VACTO I-II registries: patients with medically treated CTO (CTO-OMT group) and without CTO (no-CTO group) were compared after inverse-probability-weighting adjustment (IPWT) with a similar population of consecutive patients undergoing CTO-PCI. The primary endpoint was appropriate ICD therapy. The secondary endpoint was all-cause mortality. RESULTS: The total of 622 patients (mean age 67 ± 10 years, mean left ventricular ejection fraction 36 ± 11%) included in the analysis was composed by: CTO-PCI patients n = 113, CTO-OMT patients n = 286, no-CTO patients n = 223. In the CTO-PCI group, compared to the CTO-OMT group, 5-year Kaplan Meier estimates for appropriate ICD therapy (20.4% vs. 56.4%, IPW-adjusted HR: 0.45, 95% CI 0.29-0.71) and mortality (8.8% vs. 23%, IPW-adjusted HR: 0.43, 95% CI 0.22-0.85) were lower, driven by infarct related artery CTO (IRA-CTO) PCI, while similar to those occurring in the no-CTO group. CONCLUSIONS: In this large population, those with CTO receiving PCI had lower arrhythmic event rates and lower mortality compared to the CTO-OMT group, while showing an event rate similar to no-CTO patients. Sensitivity analyses suggest that the beneficial effect on the arrhythmic outcome was driven by IRA-CTO revascularization. CLASSIFICATION: Chronic total occlusion.


Assuntos
Cardiomiopatias , Oclusão Coronária , Desfibriladores Implantáveis , Intervenção Coronária Percutânea , Idoso , Arritmias Cardíacas/terapia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/terapia , Doença Crônica , Oclusão Coronária/complicações , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Humanos , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
18.
Hypertens Res ; 45(2): 333-343, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34789917

RESUMO

Hypertension is associated with more severe disease and adverse outcomes in COVID-19 patients. Recent investigations have indicated that hypertension might be an independent predictor of outcomes in COVID-19 patients regardless of other cardiovascular and noncardiovascular comorbidities. We explored the significance of coronary calcifications in 694 hypertensive patients in the Score-COVID registry, an Italian multicenter study conducted during the first pandemic wave in the Western world (March-April 2020). A total of 1565 patients admitted with RNA-PCR-positive nasopharyngeal swabs and chest computed tomography (CT) at hospital admission were included in the study. Clinical outcomes and cardiovascular calcifications were analyzed independently by a research core lab. Hypertensive patients had a different risk profile than nonhypertensive patients, with more cardiovascular comorbidities. The deceased hypertensive patients had a greater coronary calcification burden at the level of the anterior descending coronary artery. Hypertension status and the severity cutoffs of coronary calcifications were used to stratify the clinical outcomes. For every 100-mm3 increase in coronary calcium volume, hospital mortality in hypertensive patients increased by 8%, regardless of sex, age, diabetes, creatinine, and lung interstitial involvement. The coronary calcium score contributes to stratifying the risk of complications in COVID-19 patients. Cardiovascular calcifications appear to be a promising imaging marker for providing pathophysiological insight into cardiovascular risk factors and COVID-19 outcomes.


Assuntos
COVID-19 , Doença da Artéria Coronariana , Hipertensão , Calcificação Vascular , Cálcio , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Hipertensão/complicações , Hipertensão/epidemiologia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2 , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...