1.
Sensors (Basel) ; 18(4)2018 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-29565295

RESUMO

In water-quality, early warning systems and qualitative detection of contaminants are always challenging. There are a number of parameters that need to be measured which are not entirely linearly related to pollutant concentrations. Besides the complex correlations between variable water parameters that need to be analyzed also impairs the accuracy of quantitative detection. In aspects of these problems, the application of least-squares support vector machines (LS-SVM) is used to evaluate the water contamination and various conventional water quality sensors quantitatively. The various contaminations may cause different correlative responses of sensors, and also the degree of response is related to the concentration of the injected contaminant. Therefore to enhance the reliability and accuracy of water contamination detection a new method is proposed. In this method, a new relative response parameter is introduced to calculate the differences between water quality parameters and their baselines. A variety of regression models has been examined, as result of its high performance, the regression model based on genetic algorithm (GA) is combined with LS-SVM. In this paper, the practical application of the proposed method is considered, controlled experiments are designed, and data is collected from the experimental setup. The measured data is applied to analyze the water contamination concentration. The evaluation of results validated that the LS-SVM model can adapt to the local nonlinear variations between water quality parameters and contamination concentration with the excellent generalization ability and accuracy. The validity of the proposed approach in concentration evaluation for potassium ferricyanide is proven to be more than 0.5 mg/L in water distribution systems.

2.
Sensors (Basel) ; 17(3)2017 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-28335400

RESUMO

Water quality early warning system is mainly used to detect deliberate or accidental water pollution events in water distribution systems. Identifying the types of pollutants is necessary after detecting the presence of pollutants to provide warning information about pollutant characteristics and emergency solutions. Thus, a real-time contaminant classification methodology, which uses the multi-classification support vector machine (SVM), is proposed in this study to obtain the probability for contaminants belonging to a category. The SVM-based model selected samples with indistinct feature, which were mostly low-concentration samples as the support vectors, thereby reducing the influence of the concentration of contaminants in the building process of a pattern library. The new sample points were classified into corresponding regions after constructing the classification boundaries with the support vector. Experimental results show that the multi-classification SVM-based approach is less affected by the concentration of contaminants when establishing a pattern library compared with the cosine distance classification method. Moreover, the proposed approach avoids making a single decision when classification features are unclear in the initial phase of injecting contaminants.


Assuntos
Máquina de Vetores de Suporte , Algoritmos , Qualidade da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...