Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
3.
Eur Radiol ; 27(11): 4846-4856, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28523354

RESUMO

OBJECTIVES: Endovascular aneurysm repair (EVAR) is considered the treatment of choice for abdominal aortic aneurysms with suitable anatomy. In order to improve radiation safety, European Directive (2013/59) requires member states to implement diagnostic reference levels (DRLs) in radio-diagnostic and interventional procedures. This study aimed to determine local DRLs for EVAR across five European centres and identify an interim European DRL, which currently remains unestablished. METHODS: Retrospective data was collected for 180 standard EVARs performed between January 2014 and July 2015 from five specialist centres in Ireland (n=2) and Italy (n=3). Data capture included: air kerma-area product (PKA), total air kerma at the reference point (Ka,r), fluoroscopic time (FT), number of acquisitions, frame rate of acquisition, type of acquisition, patient height, weight, and gender. RESULTS: The mean values for each site A, B, C, D, and E were: PKAs of 4343 ± 994 µGym2, 18,200 ± 2141 µGym2, 11,423 ± 1390 µGym2, 7796 ± 704 µGym2, 31,897 ± 5798 µGym2; FTs of 816 ± 92 s, 950 ± 150 s, 708 ± 70 s, 972 ± 61 s, 827 ± 118 s; and number of acquisitions of 6.72 ± 0.56, 10.38 ± 1.54, 4.74 ± 0.19, 5.64 ± 0.36, 7.28 ± 0.65, respectively. The overall pooled 75th percentile PKA was 15,849 µGym2. CONCLUSION: Local reference levels were identified. The pooled data has been used to establish an interim European DRL for EVAR procedures. KEY POINTS: • Abdominal endovascular aneurysm repair (EVAR) requires the use of ionising radiation. • EVAR is a minimally invasive procedure for the treatment of abdominal aortic aneurysms. • Diagnostic reference levels (DRLs) are used to monitor patient radiation exposure. • Radiation dose data was collected from five European centres for EVAR procedures. • Local DRLs have been determined and an interim European DRL is proposed.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Monitoramento de Radiação/normas , Idoso , Feminino , Fluoroscopia , Humanos , Irlanda , Itália , Masculino , Doses de Radiação , Exposição à Radiação , Valores de Referência , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
4.
Hosp Pharm ; 26(4): 309-13, 319-22, 325 passim, 1991 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10110244

RESUMO

This paper describes a conceptual decision analysis model for use in multidisciplinary decision making. Decision analysis was used to structure a decision process that ensured the best choice through consensus building among hospital decision makers. The four basic steps of the decision analysis model included: (1) identifying and establishing boundaries of the decision problem; (2) structuring the decision problem; (3) characterizing information needed to fill in the structure; and (4) choosing a preferred course of action. The selection of the best intermittent intravenous drug delivery system for Presbyterian Hospital illustrates the application of the conceptual model. This type of decision analysis model becomes a useful consensus building and communication device for the administrative pharmacist who is involved in multidisciplinary decision-making processes.


Assuntos
Tomada de Decisões Gerenciais , Técnicas de Apoio para a Decisão , Modelos Teóricos , Equipe de Assistência ao Paciente/organização & administração , Serviço de Farmácia Hospitalar/organização & administração , Hospitais com mais de 500 Leitos , Bombas de Infusão/normas , Serviço Hospitalar de Compras/organização & administração , Texas
5.
Science ; 218(4575): 859-64, 1982 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-17807127

RESUMO

The selection of sites to store high-level radioactive waste will require more than technical decisions; an acceptable site must gain widespread public support. Ad hoc approaches have recently served as a stimulus to overcome institutional inertia in radioactive waste management, as exemplified by the Interagency Review Group and the State Planning Council for Radioactive Waste Management, but ad hoc approaches have not characteristically succeeded in resolving intense conflicts. Acceptable sites can best be established through traditional processes of legal and scientific advocacy, and their ultimate legitimacy will depend on the proper use of established democratic processes.

6.
Arch Environ Health ; 32(5): 200-2, 1977.
Artigo em Inglês | MEDLINE | ID: mdl-911199

RESUMO

High school sophomores residing in a community with elevated levels of sodium in the drinking water (107 mg/1) exhibited a marked upward shift in blood pressure distribution patterns for systolic and diastolic blood pressures in both males and females as compared with a similar group in the control community (8 mg/1). The students group from the high sodium community appears to exhibit a blood pressure distribution characteristic of persons several years older.


Assuntos
Pressão Sanguínea/efeitos dos fármacos , Sódio/efeitos adversos , Abastecimento de Água/normas , Adolescente , Feminino , Humanos , Masculino , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...