Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Oral Radiol ; 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39405015

RESUMO

OBJECTIVE: To assess quantitatively the effect of metallic materials on MR image uniformity using a standardized method. METHODS: Six types of 1 cm cubic metallic materials (i.e., Au, Ag, Al, Au-Ag-Pd alloy, Ti, and Co-Cr alloy) embedded in a glass phantom filled were examined and compared with no metal condition inserted as a reference. The phantom was scanned five times under each condition using a 1.5-T MR superconducting magnet scanner with an 8-channel phased-array brain coil and head and neck coil. For each examination, the phantom was scanned in three planes: axial, coronal, and sagittal using T1-weighted spin echo (SE) and gradient echo (GRE) sequences in accordance with the American Society for Testing and Materials (ASTM) F2119-07 standard. Image uniformity was assessed using the non-uniformity index (NUI), which was developed by the National Electrical Manufacturers Association (NEMA), as an appropriate standardized measure for investigating magnetic field uniformity. RESULTS: T1-GRE images with Co-Cr typically elicited the lowest uniformity, followed by T1-GRE images with Ti, while all other metallic materials did not affect image uniformity. In particular, T1-GRE images with Co-Cr showed significantly higher NUI values as far as 6.6 cm at maximum equivalent to 11 slices centering around it in comparison with the measurement uncertainty from images without metallic materials. CONCLUSION: We found that MR image uniformity was influenced by the scanning sequence and coil type when Co-Cr and Ti were present. It is assumed that the image non-uniformity in Co-Cr and Ti is caused by their high magnetic susceptibility.

2.
J Contemp Brachytherapy ; 14(3): 268-272, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36199998

RESUMO

High-dose-rate interstitial brachytherapy (HDR-ISBT) has recently come to be considered one of the most effective treatments for oral cancer. On the other hand, it is important to note that radiation therapy has some side effects. Especially, radiation-induced malignancy is probably the most serious complication affecting long-term survivors. We report a case of a radiation-induced undifferentiated spindle cell sarcoma that developed following HDR-ISBT for tongue squamous cell carcinoma (SCC). A 39-year-old woman with right tongue SCC underwent HDR-ISBT (60 Gy, 10 fractions, 8 days) treatment. Five years and one month later, a tumor had developed at the primary site. Surgery was performed for the tumor, which was histopathologically diagnosed as an undifferentiated spindle cell sarcoma. That was distinct from the squamous cell origin of the primary cancer. According to recently established criteria for radiation-induced malignancy, this case was classified as a radiation-induced sarcoma. A search of the literature revealed no previous report of radiation-induced malignancy following HDR-ISBT for tongue cancer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...