Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 150
Filtrar
1.
Front Plant Sci ; 15: 1374937, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39135648

RESUMO

To study plant organs, it is necessary to investigate the three-dimensional (3D) structures of plants. In recent years, non-destructive measurements through computed tomography (CT) have been used to understand the 3D structures of plants. In this study, we use the Chrysanthemum seticuspe capitulum inflorescence as an example and focus on contact points between the receptacles and florets within the 3D capitulum inflorescence bud structure to investigate the 3D arrangement of the florets on the receptacle. To determine the 3D order of the contact points, we constructed slice images from the CT volume data and detected the receptacles and florets in the image. However, because each CT sample comprises hundreds of slice images to be processed and each C. seticuspe capitulum inflorescence comprises several florets, manually detecting the receptacles and florets is labor-intensive. Therefore, we propose an automatic contact point detection method based on CT slice images using image recognition techniques. The proposed method improves the accuracy of contact point detection using prior knowledge that contact points exist only around the receptacle. In addition, the integration of the detection results enables the estimation of the 3D position of the contact points. According to the experimental results, we confirmed that the proposed method can detect contacts on slice images with high accuracy and estimate their 3D positions through clustering. Additionally, the sample-independent experiments showed that the proposed method achieved the same detection accuracy as sample-dependent experiments.

2.
Biol Open ; 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39133170

RESUMO

The cephalopod eye lens is unique because it has evolved as a compound structure with two physiologically distinct segments. However, the detailed ultrastructure of this lens and precise optical role of each segment are far from clear. To help elucidate structure-function relationships in the cephalopod lens we conducted multiple structural investigations on squid. Synchrotron x-ray scattering and transmission electron microscopy disclose that an extensive network of structural features that resemble cell membrane complexes form a substantial component of both anterior and posterior lens segments. Optically, the segments are distinct, however, and Talbot interferometry indicates that the posterior segment possesses a noticeably higher refractive index gradient. We propose that the hitherto unrecognised network of membrane structures in the cephalopod lens has evolved to act as an essential conduit for the internal passage of ions and other metabolic agents through what is otherwise a highly dense structure owing to a very high protein concentration.

3.
Rev Sci Instrum ; 95(7)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38990080

RESUMO

We developed a near-infrared focused heating system (IRrDAC) for deformation experiments using a rotational diamond anvil cell. This study reports the results of annealing tests on silver and antigorite conducted at SPring-8 (BL47XU) using the IRrDAC system. The experimental results demonstrated the melting of silver and the dehydration of antigorite, confirming the capability of this system. The reproducible relationships between temperature and input power were also confirmed. The IRrDAC system enables deformation experiments at pressures equivalent to those of the lower mantle under homogeneous and stable temperatures and is expected to contribute to the understanding of deep Earth rheology.

4.
Appl Environ Microbiol ; : e0056324, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023264

RESUMO

We developed a nondestructive three-dimensional microbial visualization method utilizing synchrotron radiation X-ray microscale computed tomography to better understand the relationship between microorganisms and their surrounding habitats. The method was tested and optimized using a mixture of axenic Escherichia coli and Comamonas testosteroni. The osmium-thiocarbohydrazide-osmium method was used to stain all the microbial cells, and gold in situ hybridization was used to detect specific phylogenetic microbial groups. The stained samples were embedded in epoxy resin for microtomographic analysis. Differences in X-ray absorbances were calculated by subtracting the pre-L3-edge images from the post-L3-edge images to visualize the osmium and gold signals. Although we successfully detected cells stained with osmium, those labeled with gold were not detected, probably because of the insufficient density of gold atoms in the microbial cells. We then applied the developed technique to anaerobic granules and visualized the distribution of microbial cells and extracellular polymeric substances. Empty spaces were highlighted to determine the cavity distribution in granules. Numerous independent cavities of different sizes were identified in the granules. The developed method can be applied to various environmental samples for deeper insights into microbial life in their habitats. IMPORTANCE: Microorganisms inhabit diverse environments and often form biofilms. One factor that affects their community structure is the surrounding physical environment. The arrangement of residential space within the formed biofilm plays a crucial role in the supply and transportation of substances, as well as the discharge of metabolites. Conventional approaches, such as scanning electron microscopy and confocal laser scanning microscopy combined with fluorescence in situ hybridization, have limitations as they provide information primarily from the biofilm surface and cross-sections. In this study, we developed a method for detecting microorganisms in biofilms using synchrotron radiation X-ray microscale computer tomography. The developed method allows nondestructive three-dimensional observation of biofilms at a single-cell resolution (voxel size of approximately 200 nm), facilitating an understanding of the relationship between microorganisms and their physical habitats.

5.
Zoolog Sci ; 41(3): 281-289, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38809867

RESUMO

Platyhelminthes are a phylum of simple bilaterian invertebrates with prototypic body systems. Compared with non-bilaterians such as cnidarians, the bilaterians are likely to exhibit integrated free-moving behaviors, which require a concentrated nervous system "brain" rather than the distributed nervous system of radiatans. Marine flatworms have an early cephalized 'central' nervous system compared not only with non-bilaterians but also with parasitic flatworms or freshwater planarians. In this study, we used the marine flatworm Stylochoplana pusilla as an excellent model organism in Platyhelminthes because of the early cephalized central nervous system. Here, we investigated the three-dimensional structures of the flatworm central nervous system by the use of X-ray micro-computed tomography (micro-CT) in a synchrotron radiation facility. We found that the obtained tomographic images were sufficient to discriminate some characteristic structures of the nervous system, including nerve cords around the cephalic ganglion, mushroom body-like structures, and putative optic nerves forming an optic commissure-like structure. Through the micro-CT imaging, we could obtain undistorted serial section images, permitting us to visualize precise spatial relationships of neuronal subpopulations and nerve tracts. 3-D micro-CT is very effective in the volume analysis of the nervous system at the cellular level; the methodology is straightforward and could be applied to many other non-model organisms.


Assuntos
Sistema Nervoso Central , Platelmintos , Microtomografia por Raio-X , Animais , Microtomografia por Raio-X/veterinária , Platelmintos/anatomia & histologia , Platelmintos/classificação , Sistema Nervoso Central/diagnóstico por imagem , Sistema Nervoso Central/anatomia & histologia
6.
Exp Eye Res ; 241: 109858, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38467176

RESUMO

The eye lens is responsible for focusing objects at various distances onto the retina and its refractive power is determined by its surface curvature as well as its internal gradient refractive index (GRIN). The lens continues to grow with age resulting in changes to the shape and to the GRIN profile. The present study aims to investigate how the ageing process may influence lens optical development. Murine lenses of accelerated senescence-prone strain (SAMP8) aged from 4 to 50 weeks; senescence-resistant strain (SAMR1) aged from 5 to 52 weeks as well as AKR strain (served as control) aged from 6 to 70 weeks were measured using the X-ray interferometer at the SPring-8 synchrotron Japan within three consecutive years from 2020 to 2022. Three dimensional distributions of the lens GRIN were reconstructed using the measured data and the lens shapes were determined using image segmentation in MatLab. Variations in the parameters describing the lens shape and the GRIN profile with age were compared amongst three mouse strains. With advancing age, both the lens anterior and posterior surface flattens and the lens sagittal thickness increase in all three mouse strains (Anterior radius of curvature increase at 0.008 mm/week, 0.007 mm/week and 0.002 mm/week while posterior radius of curvature increase at 0.002 mm/week, 0.007 mm/week and 0.003 mm/week respectively in AKR, SAMP8 and SAMR1 lenses). Compared with the AKR strain, the SAMP8 samples demonstrate a higher rate of increase in the posterior curvature radius (0.007 mm/week) and the thickness (0.015 mm/week), whilst the SAMR1 samples show slower increases in the anterior curvature radius (0.002 mm/week) and its thickness (0.013 mm/week). There are similar age-related trends in GRIN shape in the radial direction (in all three types of murine lenses nr2 and nr6 increase with age while nr4 decrease with age consistently) but not in the axial direction amongst three mouse strains (nz1 of AKR lens decrease while of SAMP8 and SAMR1 increase with age; nz2 of all three models increase with age; nz3 of AKR lens increase while of SAMP8 and SAMR1 decrease with age). The ageing process can influence the speed of lens shape change and affect the GRIN profile mainly in the axial direction, contributing to an accelerated decline rate of the optical power in the senescence-prone strain (3.5 D/week compared to 2.3 D/week in the AKR control model) but a retardatory decrease in the senescence-resistant strain (2.1 D/week compared to the 2.3D/week in the AKR control model).


Assuntos
Envelhecimento , Cristalino , Camundongos , Animais , Japão
7.
Biol Trace Elem Res ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489123

RESUMO

For understanding trace element dynamics in tissues, methods for analyzing elemental distribution and localization without destroying tissue structures and cell arrangements are desired. Synchrotron radiation X-ray fluorescence (SR-XRF) analysis is one of the non-destructive and multi-element simultaneous analyses. The kidney is the major excretion pathway of cesium (Cs) taken into the body, and an understanding of cesium distribution in the kidney would be useful for establishing technology to facilitate the excretion of radioactive Cs from the body due to nuclear disasters. In the present study, the distribution of cesium and trace elements, such as iron (Fe) and zinc (Zn), corresponding to the kidney structure was examined in Cs-administered mice by SR-XRF imaging with high-energy excitation X-rays (40 keV). By beam scanning with a 200-µm square beam, clear Cs images corresponding to the renal layer structure were obtained for the renal specimen at the early phase after Cs administration with the mean renal Cs concentration of 24.1 ± 3.2 µg/g. Cs was distributed mainly in the medulla and the outer stripe of the outer medulla located in the center area of the kidney. Unlike the Cs distribution, endogenous Fe and Zn tended to be lower in the medulla than in the outer stripe of the outer medulla and the cortex. This method is effective for analyzing Cs distribution because it can simultaneously analyze the distribution of endogenous trace elements.

8.
Commun Biol ; 7(1): 17, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172227

RESUMO

High-resolution 3D imaging of species with exoskeletons such as shell-bearing mollusks typically involves destructive steps. Nondestructive alternatives are desirable since samples can be rare and valuable, and destructive steps are time-consuming and may distort the tissue. Here, we show for the first time that propagation-based phase-contrast X-ray imaging can significantly increase contrast in mollusks with intact shells. By using the recently upgraded monochromator at the SPring-8 BL20B2 synchrotron beamline, we imaged six species of mollusks, showing that X-ray phase contrast enhances soft-tissue contrast. Features that are almost invisible in conventional attenuation-based micro-computed tomography (micro-CT) are clearly reproduced with phase-contrast imaging under the same scan conditions. Furthermore, this method can reveal features such as growth rings in the shell and differentiate between calcite and aragonite crystal forms. Phase-contrast imaging can thus serve as a compelling alternative when destructive methods are not an option.


Assuntos
Moluscos , Síncrotrons , Animais , Microtomografia por Raio-X/métodos , Raios X
9.
Sci Adv ; 10(3): eadi7203, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38241366

RESUMO

The Hayabusa2 spacecraft delivered samples of the carbonaceous asteroid Ryugu to Earth. Some of the sample particles show evidence of micrometeoroid impacts, which occurred on the asteroid surface. Among those, particles A0067 and A0094 have flat surfaces on which a large number of microcraters and impact melt splashes are observed. Two impact melt splashes and one microcrater were analyzed to unveil the nature of the objects that impacted the asteroid surface. The melt splashes consist mainly of Mg-Fe-rich glassy silicates and Fe-Ni sulfides. The microcrater trapped an impact melt consisting mainly of Mg-Fe-rich glassy silicate, Fe-Ni sulfides, and minor silica-rich glass. These impact melts show a single compositional trend indicating mixing of Ryugu surface materials and impactors having chondritic chemical compositions. The relict impactor in one of the melt splashes shows mineralogical similarity with anhydrous chondritic interplanetary dust particles having a probable cometary origin. The chondritic micrometeoroids probably impacted the Ryugu surface during its residence in a near-Earth orbit.

10.
Sci Total Environ ; 902: 165957, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37543314

RESUMO

Recent studies apparently finding deleterious effects of radiation exposure on cataract formation in birds and voles living near Chernobyl represent a major challenge to current radiation protection regulations. This study conducted an integrated assessment of radiation exposure on cataractogenesis using the most advanced technologies available to assess the cataract status of lenses extracted from fish caught at both Chernobyl in Ukraine and Fukushima in Japan. It was hypothesised that these novel data would reveal positive correlations between radiation dose and early indicators of cataract formation. The structure, function and optical properties of lenses were analysed from atomic to millimetre length scales. We measured the short-range order of the lens crystallin proteins using Small Angle X-Ray Scattering (SAXS) at both the SPring-8 and DIAMOND synchrotrons, the profile of the graded refractive index generated by these proteins, the epithelial cell density and organisation and finally the focal length of each lens. The results showed no evidence of a difference between the focal length, the epithelial cell densities, the refractive indices, the interference functions and the short-range order of crystallin proteins (X-ray diffraction patterns) in lens from fish exposed to different radiation doses. It could be argued that animals in the natural environment which developed cataract would be more likely, for example, to suffer predation leading to survivor bias. But the cross-length scale study presented here, by evaluating small scale molecular and cellular changes in the lens (pre-cataract formation) significantly mitigates against this issue.


Assuntos
Catarata , Acidente Nuclear de Chernobyl , Cristalinas , Animais , Espalhamento a Baixo Ângulo , Difração de Raios X , Catarata/etiologia , Catarata/veterinária , Catarata/metabolismo
11.
PLoS One ; 18(6): e0287646, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37352288

RESUMO

Human mentality develops with age and is altered in psychiatric disorders, though their underlying mechanism is unknown. In this study, we analyzed nanometer-scale three-dimensional structures of brain tissues of the anterior cingulate cortex from eight schizophrenia and eight control cases. The distribution profiles of neurite curvature of the control cases showed a trend depending on their age, resulting in an age-correlated decrease in the standard deviation of neurite curvature (Pearson's r = -0.80, p = 0.018). In contrast to the control cases, the schizophrenia cases deviate upward from this correlation, exhibiting a 60% higher neurite curvature compared with the controls (p = 7.8 × 10-4). The neurite curvature also showed a correlation with a hallucination score (Pearson's r = 0.80, p = 1.8 × 10-4), indicating that neurite structure is relevant to brain function. This report is based on our 3D analysis of human brain tissues over a decade and is unprecedented in terms of the number of cases. We suggest that neurite curvature plays a pivotal role in brain aging and can be used as a hallmark to exploit a novel treatment of schizophrenia.


Assuntos
Esquizofrenia , Humanos , Envelhecimento , Alucinações , Neuritos , Encéfalo
12.
J Synchrotron Radiat ; 30(Pt 3): 627-633, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37026390

RESUMO

Palaeohistological analysis has numerous applications in understanding the palaeobiology of extinct dinosaurs. Recent developments of synchrotron-radiation-based X-ray micro-tomography (SXMT) have allowed the non-destructive assessment of palaeohistological features in fossil skeletons. Yet, the application of the technique has been limited to specimens on the millimetre to micrometre scale because its high-resolution capacity has been obtained at the expense of a small field of view and low X-ray energy. Here, SXMT analyses of dinosaur bones with widths measuring ∼3 cm under a voxel size of ∼4 µm at beamline BL28B2 at SPring-8 (Hyogo, Japan) are reported, and the advantages of virtual-palaeohistological analyses with large field of view and high X-ray energy are explored. The analyses provide virtual thin-sections visualizing palaeohistological features comparable with those obtained by traditional palaeohistology. Namely, vascular canals, secondary osteons and lines of arrested growth are visible in the tomography images, while osteocyte lacunae are unobservable due to their micrometre-scale diameter. Virtual palaeohistology at BL28B2 is advantageous in being non-destructive, allowing multiple sampling within and across skeletal elements to exhaustively test the skeletal maturity of an animal. Continued SXMT experiments at SPring-8 should facilitate the development of SXMT experimental procedures and aid in understanding the paleobiology of extinct dinosaurs.


Assuntos
Dinossauros , Fósseis , Animais , Dinossauros/anatomia & histologia , Síncrotrons , Raios X , Microtomografia por Raio-X/métodos
13.
Sci Rep ; 13(1): 5805, 2023 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-37037865

RESUMO

Notwithstanding the various uses of rubber, the fracture mechanism of filler-reinforced rubber remains unclear. This study used four-dimensional computed tomography (4D-CT) involving monochromatic synchrotron X-rays to examine the cavitation within silica-reinforced rubber quantitatively and systematically. The results suggested a threshold value of silica content for the cavitation morphology. Macroscopic fractures, such as those developed by void formation, occurred below the threshold value of silica content. Above this threshold, the density of rubber decreased but macroscopic voids rarely occurred. The lower-density rubber area in the high-silica-content rubber was reversible at the effective pixel size for 4D-CT. These results suggest that the growth of the damage points to macrosized voids could be stopped by the formation of a network of rigid polymer layers. This study allows the elucidation of the reinforcing mechanism and the cavitation morphology of filler-reinforced rubber.

14.
Microscopy (Oxf) ; 72(4): 310-325, 2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37098215

RESUMO

Studies visualizing plant tissues and organs in three-dimension (3D) using micro-computed tomography (CT) published since approximately 2015 are reviewed. In this period, the number of publications in the field of plant sciences dealing with micro-CT has increased along with the development of high-performance lab-based micro-CT systems as well as the continuous development of cutting-edge technologies at synchrotron radiation facilities. The widespread use of commercially available lab-based micro-CT systems enabling phase-contrast imaging technique, which is suitable for the visualization of biological specimens composed of light elements, appears to have facilitated these studies. Unique features of the plant body, which are particularly utilized for the imaging of plant organs and tissues by micro-CT, are having functional air spaces and specialized cell walls, such as lignified ones. In this review, we briefly describe the basis of micro-CT technology first and then get down into details of its application in 3D visualization in plant sciences, which are categorized as follows: imaging of various organs, caryopses, seeds, other organs (reproductive organs, leaves, stems and petioles), various tissues (leaf venations, xylems, air-filled tissues, cell boundaries, cell walls), embolisms and root systems, hoping that wide users of microscopes and other imaging technologies will be interested also in micro-CT and obtain some hints for a deeper understanding of the structure of plant tissues and organs in 3D. Majority of the current morphological studies using micro-CT still appear to be at a qualitative level. Development of methodology for accurate 3D segmentation is needed for the transition of the studies from a qualitative level to a quantitative level in the future.


Assuntos
Imageamento Tridimensional , Plantas , Microtomografia por Raio-X , Síncrotrons , Microscopia de Contraste de Fase
15.
J Synchrotron Radiat ; 30(Pt 2): 400-406, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36891853

RESUMO

High-energy X-ray micro-laminography has been developed to observe inner- and near-surface structures in dense planar objects that are not suitable for observation by X-ray micro-tomography. A multilayer-monochromator-based high-intensity X-ray beam with energy of 110 keV was used for high-energy and high-resolution laminographic observations. As a demonstration of high-energy X-ray micro-laminography for observing dense planar objects, a compressed fossil cockroach on a planar matrix surface was analyzed with effective pixel sizes of 12.4 µm and 4.22 µm for wide field of view and high-resolution observations, respectively. In this analysis, the near-surface structure was clearly observed without undesired X-ray refraction-based artifacts from outside of the region of interest, a problem typical in tomographic observations. Another demonstration visualized fossil inclusions in a planar matrix. Micro-scale features of a gastropod shell and micro-fossil inclusions in the surrounding matrix were clearly visualized. When observing local structures in the dense planar object with X-ray micro-laminography, the penetrating path length in the surrounding matrix can be shortened. This is a significant advantage of X-ray micro-laminography where desired signals generated at the region of interest including optimal X-ray refraction effectively contribute to image formation without being disturbed by undesired interactions in the thick and dense surrounding matrix. Therefore, X-ray micro-laminography allows recognition of the local fine structures and slight difference in the image contrast of planar objects undetectable in a tomographic observation.

16.
Nat Astron ; 7(2): 170-181, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36845884

RESUMO

Without a protective atmosphere, space-exposed surfaces of airless Solar System bodies gradually experience an alteration in composition, structure and optical properties through a collective process called space weathering. The return of samples from near-Earth asteroid (162173) Ryugu by Hayabusa2 provides the first opportunity for laboratory study of space-weathering signatures on the most abundant type of inner solar system body: a C-type asteroid, composed of materials largely unchanged since the formation of the Solar System. Weathered Ryugu grains show areas of surface amorphization and partial melting of phyllosilicates, in which reduction from Fe3+ to Fe2+ and dehydration developed. Space weathering probably contributed to dehydration by dehydroxylation of Ryugu surface phyllosilicates that had already lost interlayer water molecules and to weakening of the 2.7 µm hydroxyl (-OH) band in reflectance spectra. For C-type asteroids in general, this indicates that a weak 2.7 µm band can signify space-weathering-induced surface dehydration, rather than bulk volatile loss.

17.
Langmuir ; 38(44): 13497-13505, 2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36288501

RESUMO

In situ observation of the migration and structure formation of magnetic particles in polyurethane elastomers was carried out by X-ray computed tomography using synchrotron radiation. The mean diameter of the magnetic particles was 7.0 µm, and the volume fraction was ϕ= 0.24 at its maximum. The exposure time was 100 ms/frame, and the pixel size was 0.458 µm/pixel. The orientation angle and the volume fraction of the maximum aggregate were analyzed using commercial software for image analysis. The orientation angle for magnetic elastomers with ϕ = 0.24 was approximately 55° at 0 mT and decreased remarkably with the magnetic field. At magnetic fields above 150 mT, the orientation angle gradually decreased with the field and showed a constant value of 38° at 300 mT, suggesting that magnetic particles move and form a chain-like structure although the chains do not align perfectly in the direction of the magnetic field. On the other hand, the volume fraction of the maximum aggregate was constant at magnetic fields below 100 mT, and it significantly increased with the field, indicating that magnetic particles were connected to each other and developed into a macroscopic structure with anisotropy. Dynamic viscoelastic measurements revealed that the storage modulus of the magnetic elastomers cannot be simply scaled by the orientation angle. It was also found that the volume fraction of the maximum aggregate is a good parameter for explaining the huge increase in the storage modulus. The dynamic movement of magnetic particles when a magnetic field of 300 mT was switched on and off was also successfully observed. When the field was switched on, magnetic particles connected instantly and their aggregates were rapidly elongated in the direction of the magnetic field. When the field was switched off, some of the connections between aggregates were broken; however, most of the aggregates did not return to the original position even 5 min after being switched off.

18.
J Synchrotron Radiat ; 29(Pt 5): 1258-1264, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36073885

RESUMO

An X-ray computed nano-tomography (nano-CT) system has been established at the BL33XU beamline of SPring-8. The optical system consists of pseudo-Köhler illumination with a sector condenser zone plate, an apodization Fresnel zone plate as the objective lens, and a Zernike phase plate. The imaging detector is a fiber-coupling type X-ray camera. The performance of the X-ray nano-CT system was confirmed by imaging an X-ray test chart. The system was subsequently applied to the observation of a microporous layer for polymer electrolyte fuel cells and a simulated microporous layer including liquid water. The nano-CT system, which can perform a computed tomography measurement in less than 4 min, allowed visualization of a spherical water droplet produced in the microporous layer. In the present study, the shape of water droplets in a nanoscale porous structure is investigated.

19.
J Synchrotron Radiat ; 29(Pt 5): 1265-1272, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36073886

RESUMO

In this study, double-multilayer monochromators that generate intense, high-energy, pink X-ray beams are designed, installed and evaluated at the SPring-8 medium-length (215 m) bending-magnet beamline BL20B2 for imaging applications. Two pairs of W/B4C multilayer mirrors are designed to utilize photon energies of 110 keV and 40 keV with bandwidths of 0.8% and 4.8%, respectively, which are more than 100 times larger when compared with the Si double-crystal monochromator (DCM) with a bandwidth of less than 0.01%. At an experimental hutch located 210 m away from the source, a large and uniform beam of size 14 mm (V) × 300 mm (H) [21 mm (V) × 300 mm (H)] was generated with a high flux density of 1.6 × 109 photons s-1 mm-2 (6.9 × 1010 photons s-1 mm-2) at 110 keV (40 keV), which marked a 300 (190) times increase in the photon flux when compared with a DCM with Si 511 (111) diffraction. The intense pink beams facilitate advanced X-ray imaging for large-sized objects such as fossils, rocks, organs and electronic devices with high speed and high spatial resolution.


Assuntos
Fótons , Síncrotrons , Raios X
20.
Microscopy (Oxf) ; 71(6): 364-373, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-35993532

RESUMO

Land plants have two types of shoot-supporting systems, root system and rhizoid system, in vascular plants and bryophytes. However, since the evolutionary origin of the systems is different, how much they exploit common systems or distinct systems to architect their structures is largely unknown. To understand the regulatory mechanism of how bryophytes architect the rhizoid system responding to environmental factors, we have developed the methodology to visualize and quantitatively analyze the rhizoid system of the moss, Physcomitrium patens, in 3D. The rhizoids having a diameter of 21.3 µm on the average were visualized by refraction-contrast X-ray micro-computed tomography using coherent X-ray optics available at synchrotron radiation facility SPring-8. Three types of shape (ring-shape, line and black circle) observed in tomographic slices of specimens embedded in paraffin were confirmed to be the rhizoids by optical and electron microscopy. Comprehensive automatic segmentation of the rhizoids, which appeared in three different form types in tomograms, was tested by a method using a Canny edge detector or machine learning. The accuracy of output images was evaluated by comparing with the manually segmented ground truth images using measures such as F1 score and Intersection over Union, revealing that the automatic segmentation using machine learning was more effective than that using the Canny edge detector. Thus, machine learning-based skeletonized 3D model revealed quite dense distribution of rhizoids. We successfully visualized the moss rhizoid system in 3D for the first time.


Assuntos
Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...