Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1191: 339309, 2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35033252

RESUMO

The synthesis of polymers with tailored properties for the recognition of macromolecules such as proteins is challenging. In this work, the synthesis of a new polymer format, a linear polymer (LP), as the selective recognition element for the globular protein lactoferrin (LF) is proposed as a proof-of-concept study. For the synthesis, a solid-phase strategy using the reversible deactivation radical polymerisation (RDRP) mechanism is proposed. This approach, which is usually used in molecular imprinting, involves the immobilisation of LF on the surface of a solid support, but, unlike classical imprinting, a cross-linker in the polymerisation mixture is not required. Consequently, the copolymer is soluble and flexible, thus overcoming the drawbacks associated with traditional synthetic polymers for macromolecule imprinting. This new polymer format has great potential for replacing natural antibodies in bioassays such as enzyme-linked immunosorbent assays (ELISA), dot blot, western blot, or pull-down. In our case, the linear polymer was used as a recognition element to replace natural antibodies in a LF-selective ELISA. The responses of the linear polymer between LF concentrations of 0.1 nM and 0.25 µM were studied, and a significant difference was observed between the non-specific signals and the signals measured in the presence of the polymeric material. Further, the response versus log concentration curves were fitted to a logistic equation, allowing estimation of the EC50 value: 11.8 ± 1.4 nM. We also confirmed the selective detection of LF using the competitive inhibition of the selective LF-biotin conjugate (LF-Bi) binding to the plastic receptor (LP) for closely related proteins (e.g. those having similar molecular weights or isoelectric points) such as human lysozyme, trypsin, and albumin, which are present in human body fluids. The system presents a cross-reactivity value or selectivity of 1.95% for lysozyme, 0.028% for trypsin, and 0.016% for albumin. The applicability of this method for the determination of urine LF levels in inflammatory and infectious diseases of the human urinary tract is also demonstrated.


Assuntos
Impressão Molecular , Polímeros , Anticorpos , Ensaio de Imunoadsorção Enzimática , Humanos , Lactoferrina
3.
J Pharm Biomed Anal ; 169: 82-89, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-30844626

RESUMO

Pediatric chronic kidney disease (CKD) is currently assessed using glomerular filtration rate (GFR), which is calculated from different equations based on serum creatinine concentration. However, serum creatinine is affected by several factors and is not reliable enough for the diagnosis of CKD, especially at early stages. Recent targeted and untargeted metabolomics studies found 7 new potential biomarkers that could be useful for early pediatric chronic kidney disease diagnosis. Thus, a new LC-QQQ-MS analytical method has been developed and validated aimed at routine analysis of these 7 potential biomarkers: NG,NG'-dimethyl-l-arginine di(p-hydroxyazobenzene-p'-sulfonate) (SDMA), S-adenosyl-l-methionine (SAM), n-butyryl-l-carnitine (nC4), iso-butyryl-l-carnitine (iC4), citrulline (CIT), creatinine (CNN) and d-erytro-sphingosine-1-phosphate (S1P), in addition to creatinine, the classical biomarker for CKD diagnosis. Then, this analytical method has been used for the quantification of plasma samples from a heterogeneous group of CKD pediatric patients and a control pediatric population. Data analysis of these results showed that it is possible to differentiate between CKD and control populations based on the metabolite concentration in plasma.


Assuntos
Biomarcadores/sangue , Biomarcadores/química , Plasma/química , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/diagnóstico , Arginina/análogos & derivados , Arginina/sangue , Arginina/química , Criança , Pré-Escolar , Cromatografia Líquida/métodos , Citrulina/química , Creatinina/sangue , Diagnóstico Precoce , Feminino , Taxa de Filtração Glomerular/fisiologia , Humanos , Masculino , Metabolômica/métodos , S-Adenosilmetionina/sangue , S-Adenosilmetionina/química , Espectrometria de Massas em Tandem/métodos
4.
Cancer Chemother Pharmacol ; 83(6): 1175-1181, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30927036

RESUMO

PURPOSE: The phase III ToGA trial established cisplatin, fluoropyrimidine and trastuzumab as the standard treatment in HER2-positive advanced gastric cancer (AGC). However, as demonstrated in HER2-negative AGC, oxaliplatin-based regimens could improve tolerance remaining effective. The aim of this trial was to explore the potential activity and safety of capecitabine, oxaliplatin (XELOX) and trastuzumab in patients with HER-2 positive advanced gastric cancer. METHODS: We conducted a multicentre, prospective, non-randomised, non-controlled, open-label and national (Spanish) phase II study. Patients with HER2-positive advanced gastric or gastro-oesophageal junction (EGJ) cancer received XELOX and trastuzumab as first-line treatment. Primary endpoint was objective tumour response rate (ORR). RESULTS: 45 patients from ten hospitals in Spain were included from September 2011 to December 2013. Median age was 65 years, 82.2% were male, 69% had gastric cancer and 31% had EGJ tumours. At a median follow-up of 13.7 months (7.1-20.9), the estimated median progression-free survival and overall survival were 7.1 (95% CI 5.5-8.7) and 13.8 months (95% CI 10.1-17.4), respectively, with 8.9%, 37.8% and 31.1% of patients achieving complete response, partial response and stable disease. Regarding safety, 44.4% of the patients had grade 3 or greater adverse events, being the most frequent diarrhoea (26.6%), fatigue (15.5%), nausea (20%) and vomiting (13.3%). Only two patients (4.4%) developed asymptomatic grade 2 left ventricle ejection fraction reduction. CONCLUSIONS: XELOX-trastuzumab is a promising and effective therapy as first-line treatment for patients with HER2-positive AGC, with comparable results to the ones obtained with other "platinum-based" regimens. This scheme is feasible and tolerable with a low incidence of cardiac toxicity.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Desoxicitidina/análogos & derivados , Junção Esofagogástrica/patologia , Fluoruracila/análogos & derivados , Neoplasias Gástricas/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Capecitabina , Desoxicitidina/administração & dosagem , Desoxicitidina/efeitos adversos , Feminino , Fluoruracila/administração & dosagem , Fluoruracila/efeitos adversos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Oxaloacetatos , Intervalo Livre de Progressão , Estudos Prospectivos , Receptor ErbB-2/metabolismo , Espanha , Neoplasias Gástricas/patologia , Taxa de Sobrevida , Trastuzumab/administração & dosagem , Resultado do Tratamento
5.
Analyst ; 143(18): 4448-4458, 2018 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-30151522

RESUMO

Pediatric chronic kidney disease (CKD) is a clinical syndrome characterized by renal hypofunction occurring due to gradual and irreversible kidney damage that can further progress over time. New biomarkers may help early diagnosis of pediatric patients suffering from CKD and improve the outcome. Untargeted metabolomics based on LC-QTOF-MS has been used to find new biomarkers for the early diagnosis of CKD in plasma from pediatric patients. In order to avoid any bias in the determination of statistically significant entities as a consequence of the data analysis method followed, two different chemometric approaches have been used, Mass Profiler Professional (MPP) software and Matlab R2015a software. Metabolic fingerprints of control and CKD pediatric patients were compared and five metabolites which showed a significant change common to both data analysis procedures were identified. Sphingosine-1-phosphate, n-butyrylcarnitine, cis-4-decenoylcarnitine and an unidentified feature with 126.0930 m/z were found to be increased in plasma from pediatric patients with CKD, whereas bilirubin was significantly decreased. A partial least squares discriminant analysis model built with these 5 entities classified correctly 96% of the samples. In addition, when considering only early CKD patients against controls, a performance of 97% was obtained. Thus, these promising metabolites could be suitable biomarkers for the early diagnosis of pediatric CKD in a clinical setting.


Assuntos
Biomarcadores/sangue , Metabolômica/métodos , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/diagnóstico , Adolescente , Criança , Pré-Escolar , Cromatografia Líquida , Feminino , Humanos , Masculino , Espectrometria de Massas em Tandem
6.
J Pharm Biomed Anal ; 149: 46-56, 2018 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-29100030

RESUMO

Chronic kidney disease (CKD) is a progressive pathological condition in which renal function deteriorates in time. The first diagnosis of CKD is often carried out in general care attention by general practitioners by means of serum creatinine (CNN) levels. However, it lacks sensitivity and thus, there is a need for new robust biomarkers to allow the detection of kidney damage particularly in early stages. Multivariate data analysis of plasma concentrations obtained from LC-QTOF targeted metabolomics method may reveal metabolites suspicious of being either up-regulated or down-regulated from urea cycle, arginine methylation and arginine-creatine metabolic pathways in CKD pediatrics and controls. The results show that citrulline (CIT), symmetric dimethylarginine (SDMA) and S-adenosylmethionine (SAM) are interesting biomarkers to support diagnosis by CNN: early CKD samples and controls were classified with an increase in classification accuracy of 18% when using these 4 metabolites compared to CNN alone. These metabolites together allow classification of the samples into a definite stage of the disease with an accuracy of 74%, being the 90% of the misclassifications one level above or below the CKD stage set by the nephrologists. Finally, sex-related, age-related and treatment-related effects were studied, to evaluate whether changes in metabolite concentration could be attributable to these factors, and to correct them in case a new equation is developed with these potential biomarkers for the diagnosis and monitoring of pediatric CKD.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Metabolômica/métodos , Insuficiência Renal Crônica/diagnóstico , Espectrometria de Massas em Tandem/métodos , Adolescente , Fatores Etários , Arginina/análogos & derivados , Arginina/sangue , Arginina/metabolismo , Biomarcadores/sangue , Criança , Pré-Escolar , Cromatografia Líquida de Alta Pressão/instrumentação , Citrulina/sangue , Citrulina/metabolismo , Creatinina/sangue , Creatinina/metabolismo , Diagnóstico Precoce , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Redes e Vias Metabólicas , Metabolômica/instrumentação , Análise Multivariada , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/metabolismo , S-Adenosilmetionina/sangue , S-Adenosilmetionina/metabolismo , Fatores Sexuais , Espectrometria de Massas em Tandem/instrumentação
7.
Anal Bioanal Chem ; 397(3): 1097-111, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20099060

RESUMO

In recent years, the extensive use of chromium in industrial processes has led to the promotion of several directives and recommendations by the European Union, that try to limit and regulate the presence of Cr(VI) in the environment and to protect industrial workers using chromium and end-users of manufactured products. As a consequence, new standard methods and analytical procedures have been published at the EU level for Cr(VI) determination in soil, sludge, sediment, and similar waste materials, workplace atmospheres, cement, packaging materials, industrially produced samples, and corrosion-protection layers on some components of vehicles and electrical and electronic equipment. The objective of this article is to summarize the different directives and recommendations and to critically review the currently existing standard methods and the methods published in the literature for chromium speciation in the above mentioned solid matrices, putting the emphasis on the different extraction procedures which have been developed for each matrix. Particular attention has been paid to Cr(III) and Cr(VI) inter-conversions that can occur during extraction and efforts to minimize these unwanted reactions. Although the use of NaOH-Na(2)CO(3) solutions with hot plate extraction seems to be the more widespread procedure, species transformation can still occur and several studies suggest that speciated isotope-dilution mass spectrometry (SIDMS) could be a suitable tool for correction of these interconversions. Besides, recent studies have proved the role of Cr(III) in chromium toxicology. As a consequence, the authors suggest an update of standard methods in the near future.


Assuntos
Cromo/análise , Monitoramento Ambiental/métodos , Monitoramento Ambiental/normas , Cromo/isolamento & purificação , Europa (Continente)
8.
Anal Chim Acta ; 641(1-2): 110-6, 2009 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-19393374

RESUMO

An automated thermal desorption-gas chromatography-mass spectrometry method for the determination of triazin herbicides in aqueous solution with excellent sensitivity was developed. The method is based on the use of stir bar sorptive extraction. The main parameters such as extraction time, sample volume, the addition of salt and organic modifiers, desorption temperature, desorption flow and desorption time which affect the efficiency of the proposed methodology are fully discussed. The proposed method is sensitive and shows a good linearity within a range of 10-10000 ng L(-1) with correlation coefficients higher than 0.998. Quantitation limits are, in all cases, below the limits accepted by European legislation for human waters consumption and ranging between 11.3 ng L(-1) and 0.7 ng L(-1). The repetitivity, expressed as a relative standard deviation, has values of lower than 8% for all analytes. Using this method, determination of 10 triazines in underground water samples was successfully performed. The average concentrations obtained in the analysis of the spiked samples at two different levels of concentration correspond to mean recoveries ranging from 94.4+/-5.1% to 106.0+/-6.3% for a significance level of 0.05.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Resíduos de Praguicidas/análise , Triazinas/análise , Poluentes Químicos da Água/análise , Adsorção , Fracionamento Químico/métodos , Temperatura Alta , Resíduos de Praguicidas/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Triazinas/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação
9.
Biomed Chromatogr ; 22(3): 265-71, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18059062

RESUMO

A rapid and sensitive HPLC enantioselective method with fluorescence detection was developed to determine (-)-(R) and (+)-(S) enantiomers of the metabolites of citalopram, demethyl- and didemethyl-citalopram in plasma and brain tissue. This assay involves pre-column chiral derivatization with (-)-(R)-1-(1-naphthyl)ethyl isocyanate followed by separation on a normal-phase silica column. The developed liquid-liquid extraction procedure permits quantitative determination of analytes with recoveries ranged between 81 and 88% with intra- and inter-day relative standard deviations less than 10.5%. Linearity was obtained over the concentration range 5-1000 ng/mL and 100-10,000 ng/g for spiked drug-free plasma and brain tissue, respectively, with detection limits lower than 2.1 ng/mL and 42.8 ng/g.


Assuntos
Encéfalo/metabolismo , Cromatografia Líquida de Alta Pressão/métodos , Citalopram/metabolismo , Inibidores Seletivos de Recaptação de Serotonina/metabolismo , Espectrometria de Fluorescência/métodos , Animais , Citalopram/sangue , Masculino , Ratos , Ratos Sprague-Dawley , Padrões de Referência , Reprodutibilidade dos Testes , Inibidores Seletivos de Recaptação de Serotonina/sangue , Estereoisomerismo
10.
J Chromatogr A ; 1094(1-2): 70-6, 2005 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-16257291

RESUMO

The aim of this study was to develop a methodology for the analysis of the insecticide fenitrothion and its two main environmental metabolites, fenitrooxon and 3-methyl-4-nitrophenol. For this purpose, a solid-phase microextraction (SPME) method coupled to high performance liquid chromatography (LC) was optimized. Two on-line detectors, diode array (DAD) and direct current amperometrical (DCAD) were used in order to determine sensitivity and selectivity. The effects of the extraction parameters, including exposure and desorption time, pH, temperature, salt concentration and desorption mode on the extraction efficiency were studied. A satisfactory reproducibility for extractions from samples at 20 ppb-level with RSD < 12.5% (n = 10) was obtained. The calibration graphs were linear in the range of 10-1000 microg l(-1) and detection limits for the target compounds were between 1.2 and 11.8 microg l(-1) depending on which detector was used. The method was applied for determining fenitrothion and both its metabolites in river waters which run through forest areas near to aerial application of the pesticide.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Eletroquímica/métodos , Fenitrotion/análise , Inseticidas/análise , Poluentes Químicos da Água/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Artigo em Inglês | MEDLINE | ID: mdl-15717781

RESUMO

Several aromatic and chlorinated volatile hydrocarbons (VOCs) were measured in Vitoria-Gasteiz City (Spain) throughout the years 1999 and 2002 in order to find out the concentration of these pollutants in urban air. These VOCs were retained in Tenax TA, subsequently desorpted by using a thermal desorption cold trap injector (TCT), and thereafter analyzed by gas chromatography/mass spectrometry (GC/MS). This analytical methodology permits the determination of 42 VOCs at very low concentrations, although only 32 of them were found in the urban air of the city (ranging from 205.51 to 0.01 microg m(-3)), with high reproducibility (%RSD lower than 10%). Twenty-four-hour samples were taken each sampling day to ascertain their total daily concentration, and rigorous quality controls were carried out to check the representativeness of sampling. Results of this exhaustive study show that toluene (T), xylenes (X), ethylbenzene (E), and benzene (B) were, respectively, the most abundant of these VOCs in the urban area during that period. The total concentration of BTEX represented, on average, more than 72.6% of the VOC total concentration, with the highest concentrations being reached in autumn, except for benzene and derived compounds (in winter). Benzene was the minority BTEX pollutant, its yearly mean concentration being less than the maximum established by the European Directive 2000/69/CE (5 microg m(-3)).


Assuntos
Poluentes Atmosféricos/análise , Hidrocarbonetos Aromáticos/análise , Hidrocarbonetos Aromáticos/química , Hidrocarbonetos Clorados/análise , Hidrocarbonetos Clorados/química , Cidades , Cromatografia Gasosa-Espectrometria de Massas , Controle de Qualidade , Reprodutibilidade dos Testes , Espanha , Volatilização
12.
J Chromatogr A ; 1059(1-2): 165-70, 2004 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-15628137

RESUMO

An analytical methodology using thermal-desorption cold trap (TCT) and GC-MS was developed for the determination of the insecticide fenitrothion and its main metabolites, 3-methyl-4-nitrophenol and fenitrooxon, in forestry atmospheres. The sampled atmosphere was pumped through a glass tube containing 100 mg of Tenax adsorbent at a flow rate of 50 ml min(-1). Adsorption/thermal desorption and breakthrough experiments were performed to test the ability to quantitatively trap the compounds. The detection limits of method for these compounds ranged between 1.6 and 2.1 ng m(-3). This methodology was developed to evaluate the persistence of fenitrothion in forest atmospheres after treatment. Spray application at 21.5 mg active ingredient m(-2) resulted in atmosphere levels of the insecticide of 78.3 ng m(-3) (after 2 h of application). Within 2-4 days following treatment, the presence of fenitrooxon fell to 50-55%. During this period residues of metabolites began to appear, disappearing 19 days later.


Assuntos
Ar/análise , Fenitrotion/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Inseticidas/análise , Árvores
13.
J Chromatogr A ; 995(1-2): 135-42, 2003 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-12800930

RESUMO

A solid-phase microextraction (SPME) method coupled to high-performance liquid chromatography with diode array detection (HPLC-DAD) for the analysis of six organochlorine fungicides (nuarimol, triadimenol, triadimefon, folpet, vinclozolin and penconazole) in wine was developed. For this purpose, polydimethylsiloxane-divinylbenzene-coated fibers were utilized and all factors affecting throughput, precision, and accuracy of the SPME method were investigated and optimized. These factors include: matrix influence, extraction and desorption time, percentage of ethanol, pH, salt effect and desorption mode. The performed analytical procedure showed detectability ranging from 4 to 27 microg l(-1) and precision from 2.4 to 14.2% (as intra-day relative standard deviation, RSD) and 4.7-25.7% (as inter-day RSD) depending on the fungicide. The results demonstrate the suitability of the SPME-HPLC-DAD method to analyze these organochlorine fungicides in red wine.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Fungicidas Industriais/análise , Halogênios/química , Vinho/análise , Fungicidas Industriais/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Analyst ; 126(4): 495-500, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11340986

RESUMO

An electrochemical sensor for the determination of serotonin in urine was prepared using Ni(II)-phthalocyanine and Nafion to modify the surface of a 4 mm length carbon fiber microelectrode. The resultant sensor was found to improve the response towards this neuronal amine versus the microelectrode without the polymer films. Different polymerization conditions, as well as different conditioning solutions and buffer systems, were investigated in order to optimize the response of the electrodes. Square wave voltammetry (SWV) is proposed as a direct method for determination of serotonin in human urine, after a solid-liquid extraction process. The proposed method enables a detection limit for serotonin of 0.80 +/- 0.04 microgram L-1 to be achieved at a reduction potential of 0.35 V, with an overall prediction error of 2.2% and recoveries of 93%.


Assuntos
Serotonina/urina , Carbono , Eletroquímica/instrumentação , Humanos , Microeletrodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...