Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Br J Anaesth ; 119(4): 844, 2017 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29121318
2.
Br J Anaesth ; 119(6): 1244, 2017 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29156041
7.
Minerva Anestesiol ; 79(5): 564-70, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23419338

RESUMO

Traditionally, continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BiPAP) devices have been used to treat patients in acute respiratory failure. However they require an electric power source, are relatively large in size, and may be difficult to use in prehospital settings. The recently introduced Boussignac CPAP system is capable of delivering 10 cmH2O of CPAP, is compact, portable and requires only an oxygen source. This paper reviews the efficacy of using Boussignac CPAP as a treatment for acute respiratory failure in both prehospital and hospital settings. All studies mainly focused on patients treated for cardiogenic pulmonary edema. In the prehospital setting, Boussigac CPAP significantly improved respiratory parameters and oxygenation from baseline values. In the emergency department setting, Boussignac CPAP was more effective than standard oxygen delivery and just as effective as BiPAP in improving patient oxygenation and respiration. In one study, implementing Boussignac CPAP reduced intubation rate and hospital stay. Most hospital staff found Boussignac CPAP easy to use and complication rates were low. Boussigac CPAP is a useful device in the treatment of patients with acute respiratory failure, especially in the prehospital setting.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Insuficiência Respiratória/terapia , Serviços Médicos de Emergência , Serviço Hospitalar de Emergência , Hospitais , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
8.
Minerva Anestesiol ; 79(6): 679-82, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23370120

RESUMO

In extreme emergency situations, patients may need to undergo endotracheal intubation, while in a non-supine position. This manuscript offers several options to the anesthesiologist to cope with tracheal intubations in non-standard positions. The authors stress that there is a need for adequate training in an anaesthesia skills lab, whereby classic direct laryngoscopy and indirect videolaryngoscopy should be practiced on manikins, before our trainees actually practice anesthesia on patients in operating theatres. This manuscript is also a plea for developing an algorithm for emergency airway management in the non-supine position.


Assuntos
Anestesiologia/educação , Intubação Intratraqueal/métodos , Posicionamento do Paciente , Manuseio das Vias Aéreas/métodos , Algoritmos , Competência Clínica , Humanos , Laringoscopia , Manequins , Decúbito Dorsal/fisiologia
9.
Acta Anaesthesiol Scand ; 57(1): 77-81, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23167262

RESUMO

BACKGROUND: Many extraglottic airway devices allow the direct passage of an adult-sized tracheal tube, but this is not possible with the LMA-Supreme(TM) . We evaluated the feasibility of using the LMA-Supreme(TM) as a conduit for intubation in patients with known difficult airways. METHODS: Sixty-eight adult patients, with preoperative predictors of difficult intubation, were scheduled for elective surgery under general anaesthesia. After assessing the direct laryngoscopy view, 23 patients with Cormack-Lehane III/IV were included in the study. An LMA-Supreme(TM) was inserted, followed by the passage of a flexible bronchoscope loaded with an Aintree Intubation Catheter into the trachea. The bronchoscope and LMA-Supreme(TM) were removed, and a tracheal tube was railroaded over the Aintree Intubation Catheter into the trachea. RESULTS: Tracheal intubation was successful in all patients using the above technique. SpO(2) was >95% during the intubation procedure. CONCLUSIONS: We conclude that the LMA-Supreme(TM) is a successful conduit for bronchoscopic/Aintree Intubation Catheter-guided intubation in patients with known difficult airway.


Assuntos
Manuseio das Vias Aéreas/instrumentação , Intubação Intratraqueal/instrumentação , Máscaras Laríngeas , Adulto , Idoso , Manuseio das Vias Aéreas/efeitos adversos , Manuseio das Vias Aéreas/métodos , Anestesia por Inalação , Broncoscopia , Estudos de Viabilidade , Feminino , Humanos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/métodos , Máscaras Laríngeas/efeitos adversos , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Estudos Prospectivos
10.
Anaesthesia ; 67(12): 1375-85, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23130725

RESUMO

The practice of anaesthesia was revolutionised by the ideas of Archie Brain. The routine use of a facemask to manage the airway was not a hands-free technique, despite the development of various harnesses, and made adequate record-keeping difficult. The tracheal tube was associated with some morbidity, which some felt was unsuitable for day surgery. Brain developed an airway management device that was less stressful to the patient than tracheal intubation, and was, however, as safe as using a facemask and airway. Brain also hoped his device would function for cases where mask ventilation was particularly difficult and thus give anaesthetists a safer alternative to a complex intubation, especially in emergency scenarios.


Assuntos
Máscaras Laríngeas/história , Desenho de Equipamento/história , História do Século XX , Humanos , Londres , Masculino , Estados Unidos
11.
Acta Anaesthesiol Belg ; 63(1): 35-41, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22783708

RESUMO

INTRODUCTION: We test the hypothesis that there are differences in performance among three extra-glottic airway devices during spontaneous breathing anaesthesia. METHODS: One hundred and fifty consecutive patients (ASA Grade 1-2, aged 18-80 yr) were randomly allocated for airway management with the i-gel (Intersurgical Ltd, Wokingham, Berkshire UK), the LMA-ProSeal and the LMA-Supreme (The Laryngeal Mask Company Ltd, Wooburn Green, Bucks, UK). Anaesthesia was with fentanyl/propofol/sevoflurane mixture. A laryngoscope-guided, gastric tube-guided technique was used for insertion. The following primary variables were assessed: ease of insertion, effective airway time, anatomical position, oropharyngeal leak pressure among devices, and change in oropharyngeal leak pressure between 30 and 60 minutes for each device during the spontaneous breathing anaesthesia. RESULTS: Differences detected were that the LMA-Supreme was easier to insert and had a shorter effective airway time than the LMA-Proseal and i-gel. Anatomical position was better for the LMA-Supreme than for the i-gel. Oropharyngeal leak pressures were similar among devices during apnoea and spontaneous ventilation, but much higher than in the first generation classic type of laryngeal masks. There were no changes in oropharyngeal leak pressure for any device during the spontaneous breathing phase. There were no differences in performance for any variable between the LMA-ProSeal and i-gel. CONCLUSION: The LMA-Supreme is easier and quicker to insert than the LMA-ProSeal and i-gel using a laryngoscope-guided, gastric tube-guided technique and is associated with better anatomical positioning than the i-gel. Oropharyngeal leak pressures are similar among devices.


Assuntos
Anestesia Geral/métodos , Intubação Intratraqueal/instrumentação , Máscaras Laríngeas , Laringoscopia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Fentanila/administração & dosagem , Humanos , Masculino , Éteres Metílicos/administração & dosagem , Pessoa de Meia-Idade , Propofol/administração & dosagem , Sevoflurano , Fatores de Tempo , Adulto Jovem
12.
Anaesth Intensive Care ; 40(2): 311-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22417027

RESUMO

The demand for increased patient safety has led to greater use of simulation training of health professionals performing medical procedures. The study aim was to evaluate the usefulness of the Mediseus® Epidural Simulator in teaching basic epidural needle-handling skills. Three groups of 15 anaesthetists (Novice=zero to two year anaesthesia trainees; Intermediate=three- to five-year anaesthesia trainees; Expert=consultants and regional-specialist anaesthetists) from three different medical centres participated. Each participant performed 20 simulated epidural needle insertions and was scored on several parameters (e.g. time, success of the insertion, bone collisions). Following familiarisation with the simulator and the needle insertions, participants answered seven questions on the applicability of the simulator to the teaching of basic epidural needle-handling skills. There was a clear learning effect with regard to the simulation procedure time, this decreasing throughout the experiment (P=0.037). There was no significant influence of either group or experience with the simulator in the study on the number or type of errors made. The quality of the simulation was scored 2.3 out of 5.0 (for bone simulation) and 4.7 (for loss-of-resistance simulation). All groups considered that the simulator was best suited for training prospective anaesthetists. Each group rated the usefulness of the simulator for training novices at greater than 3.0 out of 5.0. The Mediseus® Epidural Simulator seems to be an appropriate training device for an introduction to epidural needle insertion. For medical professionals with procedural knowledge, the simulation is not realistic enough and the simulator did not distinguish between the groups based on the errors made.


Assuntos
Anestesia Epidural/métodos , Anestesiologia/educação , Competência Clínica , Espaço Epidural/fisiologia , Simulação por Computador , Computadores , Humanos , Injeções , Aprendizagem , Modelos Lineares , Modelos Anatômicos , Agulhas , Reprodutibilidade dos Testes , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...