Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38430228

RESUMO

PURPOSE: This review explores mathematical models, blinking characterization, and non-invasive techniques to enhance understanding and refine clinical interventions for ocular conditions, particularly for contact lens wear. METHODS: The review evaluates mathematical models in tear film dynamics and their limitations, discusses contact lens wear models, and highlights computational mechanical models. It also explores computational techniques, customization of models based on individual blinking dynamics, and non-invasive diagnostic tools like high-speed cameras and advanced imaging technologies. RESULTS: Mathematical models provide insights into tear film dynamics but face challenges due to simplifications. Contact lens wear models reveal complex ocular physiology and design aspects, aiding in lens development. Computational mechanical models explore eye biomechanics, often integrating tear film dynamics into a Multiphysics framework. While different computational techniques have their advantages and disadvantages, non-invasive tools like OCT and thermal imaging play a crucial role in customizing these Multiphysics models, particularly for contact lens wearers. CONCLUSION: Recent advancements in mathematical modeling and non-invasive tools have revolutionized ocular health research, enabling personalized approaches. The review underscores the importance of interdisciplinary exploration in the Multiphysics approach involving tear film dynamics and biomechanics for contact lens wearers, promoting advancements in eye care and broader ocular health research.

2.
Children (Basel) ; 11(2)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38397251

RESUMO

BACKGROUND: Childhood myopia represents a global concern with increasing prevalence in recent decades. Lifestyle factors significantly impact myopia. AIM: To evaluate lifestyle factors in myopic children from a metropolitan area in Europe. METHODS: This was a descriptive study including myopic subjects aged 4-18 years. Patient demographic and clinical data were collected, including cycloplegic refraction in spherical equivalent refraction (SER) and axial length (AL). In addition, a questionnaire on lifestyle factors was conducted between September 2022 and April 2023. RESULTS: A total of 321 myopic children were included, aged 10.72 ± 3.05 years, of whom 51.4% were boys, with SER -2.25 ± 1.9 D and AL 24.54 ± 0.98 mm. The mean age of myopia onset was 7.69 ± 3.05 years. A total of 59.8% had family history of myopia. Those children who had <2 h/day of screen time (on weekdays) presented SER -2 ± 1.91 D, compared to those who had >2 h/day, SER: -2.50 ±1.88 D (p = 0.009). Children who spent <2 h/day doing near work after school were less myopic compared to those who spent >2 h/day (SER: -1.75 ± 1.83 vs. SER: -2.75 ± 1.82, respectively, p = 0.03). However, no significant association was observed between SER and AL and time spent outdoors nor between SER and AL and academic performance (p > 0.05). CONCLUSIONS: Screen time and near-work time appear to be lifestyle factors related to myopia.

3.
J Vet Intern Med ; 38(1): 161-166, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38100467

RESUMO

BACKGROUND: The utility of neutrophil-to-lymphocyte ratio (NLR), platelet to-lymphocyte ratio (PLR) and monocyte-to-lymphocyte ratio (MLR) as prognostic indicators has not been investigated in canine parvovirosis (CPV). HYPOTHESIS: To evaluate whether these hematological ratios obtained at hospital admission in CPV are associated with outcome or duration of hospitalization. ANIMALS: Four hundred one client-owned dogs presented with CPV. Methods-Retrospective multicenter cohort study. Medical records were reviewed to identify dogs with CPV. Data regarding signalment, complete blood count at admission, duration of hospitalization and outcome were collected. RESULTS: Of the 401 dogs included in the study, 336 (83.8%) survived to discharge. The median (25th and 75th percentiles) PLR in nonsurvivors (336.56 [159.84-635.77]) was significantly higher than in survivors (217.65 [117.67-389.65]) (P = .003). The area under the receiver-operating characteristic curve for nonsurvival was 0.615 (95% CI [0.593-0.691], P = .003). A cut off of 700 showed a 21.5% sensitivity and 90% specificity for nonsurvival. No association was observed between hospitalization duration and either hematological ratios or total WBC counts. The median (25th and 75th percentiles) lymphocyte count was below reference interval in all dogs and was significantly lower in the dogs which died (0.82 × 109 /L [0.5-1.87]) than in survivors (1.27 × 109 /L [0.73-2.22]) (P = .005). The median (25th and 75th percentiles) monocyte count however was lower in survivors (0.38 × 109 /L [0.29-1.59]), than in nonsurvivors (0.73 × 109 /L [0.1-2]) (P = .002). CONCLUSIONS: Evaluation of PLR at hospital admission might be a useful marker of disease severity and could have prognostic value in dogs with CPV.


Assuntos
Plaquetas , Linfócitos , Humanos , Cães , Animais , Estudos Retrospectivos , Estudos de Coortes , Contagem de Leucócitos/veterinária , Prognóstico , Neutrófilos
4.
J Eye Mov Res ; 16(3)2023.
Artigo em Inglês | MEDLINE | ID: mdl-38111688

RESUMO

This systematic review examines the use of eye-tracking devices in optometry, describing their main characteristics, areas of application and metrics used. Using the PRISMA method, a systematic search was performed of three databases. The search strategy identified 141 reports relevant to this topic, indicating the exponential growth over the past ten years of the use of eye trackers in optometry. Eye-tracking technology was applied in at least 12 areas of the field of optometry and rehabilitation, the main ones being optometric device technology, and the assessment, treatment, and analysis of ocular disorders. The main devices reported on were infrared light-based and had an image capture frequency of 60 Hz to 2000 Hz. The main metrics mentioned were fixations, saccadic movements, smooth pursuit, microsaccades, and pupil variables. Study quality was sometimes limited in that incomplete information was provided regarding the devices used, the study design, the methods used, participants' visual function and statistical treatment of data. While there is still a need for more research in this area, eye-tracking devices should be more actively incorporated as a useful tool with both clinical and research applications. This review highlights the robustness this technology offers to obtain objective information about a person's vision in terms of optometry and visual function, with implications for improving visual health services and our understanding of the vision process.

5.
Int J Mol Sci ; 24(21)2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37958577

RESUMO

Climate-change-induced temperature fluctuations pose a significant threat to crop production, particularly in the Southern Hemisphere. This study investigates the transcriptome and physiological responses of rapeseed to post-flowering temperature increases, providing valuable insights into the molecular mechanisms underlying rapeseed tolerance to heat stress. Two rapeseed genotypes, Lumen and Solar, were assessed under control and heat stress conditions in field experiments conducted in Valdivia, Chile. Results showed that seed yield and seed number were negatively affected by heat stress, with genotype-specific responses. Lumen exhibited an average of 9.3% seed yield reduction, whereas Solar showed a 28.7% reduction. RNA-seq analysis of siliques and seeds revealed tissue-specific responses to heat stress, with siliques being more sensitive to temperature stress. Hierarchical clustering analysis identified distinct gene clusters reflecting different aspects of heat stress adaptation in siliques, with a role for protein folding in maintaining silique development and seed quality under high-temperature conditions. In seeds, three distinct patterns of heat-responsive gene expression were observed, with genes involved in protein folding and response to heat showing genotype-specific expression. Gene coexpression network analysis revealed major modules for rapeseed yield and quality, as well as the trade-off between seed number and seed weight. Overall, this study contributes to understanding the molecular mechanisms underlying rapeseed tolerance to heat stress and can inform crop improvement strategies targeting yield optimization under changing environmental conditions.


Assuntos
Brassica napus , Brassica rapa , Brassica napus/genética , Transcriptoma , Temperatura , Brassica rapa/genética , Genótipo , Sementes/metabolismo
6.
Diagnostics (Basel) ; 13(20)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37892009

RESUMO

OBJECTIVE: To describe corneal confocal microscopy findings in patients with long COVID-19 with persistent symptoms over 20 months after SARS-CoV-2 infection. DESIGN: A descriptive cross-sectional study that included a total of 88 patients; 60 patients with Long COVID-19 and 28 controls. Long COVID-19 diagnosis was established according to the World Health Organization criteria. Corneal confocal microscopy using a Heidelberg Retina Tomograph II (Heidelberg Engineering, Heidelberg, Germany) was performed to evaluate sub-basal nerve plexus morphology (corneal nerve fiber density, nerve fiber length, nerve branch density, nerve fiber total branch density, nerve fiber area, and nerve fiber width). Dendritic cell density and area, along with microneuromas and other morphological changes of the nerve fibers were recorded. RESULTS: Long COVID-19 patients presented with reduced corneal nerve density and branch density as well as shorter corneal nerves compared to the control group. Additionally, Long COVID-19 patients showed an increased density of dendritic cells also with a greater area than that found in the control group of patients without systemic diseases. Microneuromas were detected in 15% of Long COVID-19 patients. CONCLUSIONS: Long COVID-19 patients exhibited altered corneal nerve parameters and increased DC density over 20 months after acute SARS-CoV-2 infection. These findings are consistent with a neuroinflammatory condition hypothesized to be present in patients with Long COVID-19, highlighting the potential role of corneal confocal microscopy as a promising noninvasive technique for the study of patients with Long COVID-19.

7.
PLoS One ; 18(6): e0286884, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37289791

RESUMO

PURPOSE: To investigate the possible risk factors for treatment failure in patients who had undergone Preserflo Microshunt (PMS) implantation, using anterior-segment optical coherence tomography (AS-OCT) to analyze the internal structures of the bleb. METHODS: The PMS blebs of 54 patients were evaluated with AS-OCT. A mathematical model was used to calculate the total filtering surface of the episcleral fluid cavity (EFC) and the hydraulic conductivity (HC) of the bleb wall. Complete and qualified success were defined as IOP between 6 and 17 mmHg with or without glaucoma medication. The relation between baseline characteristics and probability of bleb success was analyzed by bivariate and multivariate logistic regression. The main outcome measures were mean bleb wall thickness (BWT), reflectivity (BWR), HC, mean horizontal and vertical diameter and total filtering surface (TFS) of the EFC. RESULTS: Blebs from 74% patients were considered as complete success and 26% as failure. BWR and BWT increased linearly up to the first year in both groups. BWR was higher in the group failure (p = 0.02) and BWT in the group success (p<0.001). EFC was wider and shorter in the success group (p = 0.009, p = 0.03). Higher TFS showed a negative correlation with IOP (r = -0.4, p = 0.002). Higher baseline IOP was associated with success of PMS by multivariate analysis (p = 0.01). Mean HC, 0.034 ± 0.008 (µL/min)/mm2/mmHg, was negatively correlated with bleb surface (r = -0.5, p<0.0001) and wall´s thickness (r = -0.3, p = 0.01). CONCLUSIONS: AS-OCT revealed that successful PMS blebs could show either thick hyporreflective walls or wide filtering surfaces with thin capsules. A higher baseline IOP increased the probability of surgical success.


Assuntos
Glaucoma , Trabeculectomia , Humanos , Trabeculectomia/métodos , Segmento Anterior do Olho , Pressão Intraocular , Túnica Conjuntiva/cirurgia , Glaucoma/cirurgia , Tomografia de Coerência Óptica/métodos
8.
Vet Rec ; 192(10): e2683, 2023 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-36755402

RESUMO

BACKGROUND: Myocarditis frequently occurs in canine leishmaniosis (CanL). Heart fatty acid-binding protein (HFABP) is a biomarker of myocardial damage. METHODS: This study aimed to compare HFABP concentration (HFABPc) in healthy dogs and dogs at different stages of CanL and evaluate the correlation of this biomarker with several clinicopathological and echocardiographic variables. Thirty-one dogs diagnosed with CanL and 10 healthy dogs were included. RESULTS: HFABPc was not statistically different (p > 0.05) between groups of dogs at different LeishVet stages of CanL or between groups with high versus low to intermediate serology titres. In 70% of CanL dogs, HFABPc was within the 95% confidence interval limits of the mean of healthy dogs. A moderate negative correlation with globulin (r = -0.519; p = 0.03) and haematocrit (HCT) (r = -0.538; p = 0.02) was observed. No other significant correlation (p > 0.05) was observed with any other variable. LIMITATIONS: Many statistical tests were performed, and therefore, type I error cannot be ruled out. CONCLUSION: HFABPc is not consistently elevated in dogs with CanL and is not associated with the severity of the disease, or most echocardiographic or clinicopathological variables studied. The correlation with globulin and HCT was not strong and not considered clinically significant. HFABPc lacks sufficient predictive capacity in dogs with CanL, discouraging further research or clinical use of this biomarker in this disease.


Assuntos
Doenças do Cão , Leishmania infantum , Leishmaniose Visceral , Leishmaniose , Cães , Animais , Doenças do Cão/diagnóstico , Leishmaniose/veterinária , Biomarcadores , Leishmaniose Visceral/veterinária
9.
J Clin Med ; 11(13)2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35807117

RESUMO

Background: Due to the importance of choroidal thickness in the development of myopia, this study examined the effect of MiSight contact lenses (CLs) on the choroidal thickness of myopic children and the differences between responders and non-responders to the treatment with these CLs. Methods: A total of 41 myopic children were fitted with MiSight CLs and 33 with single-vision spectacles. They were followed up for two years. Subfoveal choroidal thickness and choroidal thickness 1 and 3 mm temporal and nasal to the fovea were measured by OCT at baseline and one and two years after the treatment. Differences in all the choroidal thickness parameters were assessed in each group over time. Patients from the MiSight group were classified based on a specific range of changes in axial length at the end of the second year of treatment as "responders" (AL change < 0.22 mm/per year) and "non-responders", and the choroidal thickness of both groups was analyzed. Results: The subfoveal choroidal thickness of the MiSight and single-vision spectacle groups did not show any changes over time. Wearing MiSight CLs induced relative choroidal thickening in the responder group in the first year of treatment. Conclusion: Choroidal thickness might work as a predictor of the effectiveness of MiSight in myopia treatment.

10.
Chemosphere ; 300: 134517, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35398065

RESUMO

Metal contamination of soil has become a serious environmental problem worldwide. Many studies have attempted to infer metal ecotoxicity from soil microbial responses. However, much of the data from these studies tends to be inconsistent and difficult to interpret. We hypothesized that microbial response would be a useful indicator of metal toxicity in soils contaminated by copper mining in Chile. Eighty-four topsoils (0-20 cm) were collected from three areas historically contaminated by copper mining (total Cu: 46-1106 mg kg-1, soluble Cu: 0.05-2.3 mg kg-1, pCu2+: 6.3-10, pH: 5.1-7.8, organic matter: 1.1-10%, clay: 0-28%). Based on soil metal concentrations and ecotoxicity thresholds, Cu was expected to be toxic to microorganisms in the studied soils, while the effects of other metals (total Zn: 79-672, As: 1.9-60, Pb: 19-220, Cd: 0.4-5.1 mg kg-1) were expected to be minor. Soil microbial responses (microbial biomass and numbers, nitrogen mineralization and nitrification, and community-level physiological profiles) were also measured. The results showed that the different responses of soil microbes were not correlated with each other. Furthermore, the soil microbial responses were mainly influenced by the physicochemical properties of the soil, not by the metal concentrations in the soil. The effect of copper on the microbial response was either stimulating (positive) or toxic (negative). Of the soil microbial responses measured in this study, only the microbial biomass was useful for calculating dose-response curves. However, the microbial biomass response was not consistent among the different soil copper pools (total copper, soluble copper, and activity of free Cu2+ ions). It is important to emphasize that the thresholds obtained for copper toxicity cannot be adopted in a robust manner because of the different microbial responses in different sampling areas. Thus, in the copper-contaminated soils under study, microbial response was found to be an unreliable indicator of metal toxicity.


Assuntos
Metais Pesados , Poluentes do Solo , Cobre/análise , Cobre/toxicidade , Poluição Ambiental , Intoxicação por Metais Pesados , Humanos , Metais , Mineração , Solo/química , Poluentes do Solo/análise , Poluentes do Solo/toxicidade
11.
J Optom ; 15(1): 78-87, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33750678

RESUMO

PURPOSE: To investigate which baseline factors are predictive for success in controlling myopia progression in a group of children wearing MiSight Contact Lens (CLs). METHODS: Myopic patients (n=41) fitted with MiSight CLs and followed up two years were included in this study. Bivariate analysis, a logistic regression analysis (LG) and a decision tree (DT) approach were used to screen for the factors influencing the success of the treatment. To assess the response, axial length (AL) changes were considered as main variable. Patients were classified based on a specific range of change of axial length at the end of each year of treatment as "responders" (R) (AL change <0.11mm/per year) and "non-responders" (NR) (AL change ≥0.11mm/per year). RESULTS: Of a total of forty-one Caucasian patients treated with MiSight CLs, 21 and 16 were considered responders in the first and the second year of follow-up, respectively. LG analysis showed that the only factor associated with smaller axial length growth was more time spent outdoors (p=0.0079) in the first year of treatment. The decision tree analysis showed that in the responding group spending more than 3 and 4h outdoors per week was associated with the best response in the first year and in the second year of treatment respectively. CONCLUSIONS: The LR and the DT approach of this pilot study identifies time spent outdoors as a main factor in controlling axial eye growth in children treated with MiSight CLs.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Comprimento Axial do Olho , Criança , Progressão da Doença , Humanos , Miopia/diagnóstico , Miopia/terapia , Projetos Piloto , Refração Ocular , Espanha
12.
Eur J Ophthalmol ; 32(3): 1441-1447, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34313139

RESUMO

PURPOSE: To analyse the effect of femtosecond laser-assisted in situ keratomileusis (FS-LASIK) on the electrical response of retinal ganglion cells using pattern electroretinography (pERG). METHODS: This was a longitudinal, prospective, observational pilot study. We included consecutive myopic patients who underwent FS-LASIK to correct up to 6 dioptres of myopia and up to 2 dioptres of astigmatism. Patients with excessive blinking or tearing and those with Snellen uncorrected visual acuity less than 0.9 dec on postop day 1 were excluded. Diopsys NOVA® (Diopsys Inc., NJ) pERG records, using high- and low-contrast patterns, were obtained 16 h and 1 month after FS-LASIK was performed. Magnitude (µV), Magnitude D (µV), Magnitude D/Magnitude ratio and signal-to-noise ratio (dB) were analysed. Wilcoxon test for nonparametric paired data was employed. RESULTS: pERG data from 24 eyes were analysed from 24 patients who underwent FS-LASIK. Mean age was 35.79 ± 9.86 years. Mean preoperative refraction was -2.69 ± 7.6 D (spherical) and -0.38 ± 0.40 D (cylinder). Mean surgical time was 56.88 ± 7.6 s. No statistically significant differences were obtained for any of the studied parameters when comparing 16 h with 1 month after FS-LASIK, with the exception of Magnitude with low contrast, which increased from 1.21 ± 0.2 to 1.39 ± 0.29 µV at 16 h and 1 month postoperatively, respectively (p = 0.03). CONCLUSIONS: FS-LASIK seems to induce a mild and transitory defect in retinal ganglion cell function. Only a mild decrease was detected in the magnitude value for low-contrast stimuli when pERG was performed 16 h postoperatively, and it returned to normal 1 month after surgery.


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Adulto , Humanos , Lasers de Excimer/uso terapêutico , Pessoa de Meia-Idade , Miopia/cirurgia , Estudos Prospectivos , Refração Ocular , Células Ganglionares da Retina , Resultado do Tratamento
13.
Diagnostics (Basel) ; 13(1)2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36611338

RESUMO

In vivo corneal confocal microscopy (IVCM) is a non-invasive ophthalmic imaging technique that provides images of the cornea at the cellular level. Despite the uses in ocular surface pathologies, in the last decades IVCM has been used to provide more knowledge in refractive surgery wound healing, in neuropathies diagnosis, etc. The observation of the corneal cells, both normal and inflammatory, and the possibility of quantification of the corneal nerve density with manual or automated tools, makes IVCM have a significant potential to improve the diagnosis and prognosis in several systemic and corneal conditions.

14.
Transl Vis Sci Technol ; 10(13): 26, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34792556

RESUMO

Purpose: To measure the in vitro flow properties of the PRESERFLO implant for comparison with the theoretical resistance to flow. Methods: The PRESERFLO was designed to control the flow of aqueous humor according to the Hagen-Poiseuille (HP) equation. Scanning electron microscopy (SEM) was performed to analyze the ultrastructure, and flow measurements were carried out using a gravity-flow setup. Results: SEM images of the PRESERFLO showed luminal diameters of 67.73 × 65.95 µm and 63.66 × 70.54 µm. The total diameter was 337.2 µm, and the wall was 154 µm wide. The theoretical calculation of the resistance to flow (R) for an aqueous humor (AH) viscosity of 0.7185 centipoises (cP) was 1.3 mm Hg/(µL/min). Hence, assuming a constant AH flow of 2 µL/min, the pressure differential across the device (ΔP) was estimated to be 2.6 mm Hg. The gravity-flow experiment allowed us to measure the experimental resistance to flow, which was RE = 1.301 mm Hg/(µL/min), in agreement with the theoretical resistance to flow R given by the HP equation. Conclusions: The experimental and theoretical flow testing showed that the pressure drop across this device would not be large enough to avoid hypotony unless the resistance to outflow of the sub-Tenon space was sufficient to control the intraocular pressure in the early postoperative period. Translational Relevance: The fluid properties of glaucoma subconjunctival drainage devices determine their specific bleb-forming capacity and ability to avoid hypotony and therefore their safety and efficacy profile.


Assuntos
Implantes para Drenagem de Glaucoma , Humor Aquoso , Pressão Intraocular , Tonometria Ocular
15.
Transl Vis Sci Technol ; 10(3): 9, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34003943

RESUMO

Purpose: The purpose of this study was to measure the intraocular pressure (IOP) elevation during laser assisted in situ keratomileusis (LASIK) flap creation using the WaveLight FS200 femtosecond (FS) laser platform. Methods: We conducted an ex vivo experimental study in an animal model. The WaveLight FS200 FS laser platform was used to perform the corneal LASIK flap in freshly enucleated porcine eyes. We measured the changes in IOP from the application of the suction ring (suctioning phase) through the creation of the lamellar corneal flap (cutting phase). The IOP was recorded using a manometric technique with direct cannulation to the anterior chamber. Results: Nine freshly enucleated porcine eyes were included in the study. The mean baseline IOP before the procedure was 20.33 ± 5.9 mm Hg. The mean IOP increase over baseline IOP was 32.33 ± 11.3 mm Hg at the suctioning phase, and 38.22 ± 11.3 mm Hg at the cutting phase. The total surgical time needed to complete the procedure was 29.5 ± 4.4 seconds. Conclusions: The WaveLight FS200 FS laser platform produces a low to moderate increase in IOP during LASIK flap creation. Translational Relevance: The WaveLight FS200 is a safe FS laser platform because it induces a low to moderate IOP increase during LASIK flap creation.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Animais , Pressão Intraocular , Lasers , Retalhos Cirúrgicos , Suínos , Tonometria Ocular
16.
Int J Mol Sci ; 22(9)2021 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-33923211

RESUMO

A critical barrier to improving crop yield is the trade-off between seed weight (SW) and seed number (SN), which has been commonly reported in several crops, including Brassica napus. Despite the agronomic relevance of this issue, the molecular factors involved in the interaction between SW and SN are largely unknown in crops. In this work, we performed a detailed transcriptomic analysis of 48 seed samples obtained from two rapeseed spring genotypes subjected to different source-sink (S-S) ratios in order to examine the relationship between SW and SN under different field conditions. A multifactorial analysis of the RNA-seq data was used to identify a group of 1014 genes exclusively regulated by the S-S ratio. We found that a reduction in the S-S ratio during seed filling induces the expression of genes involved in sucrose transport, seed weight, and stress responses. Moreover, we identified five co-expression modules that are positively correlated with SW and negatively correlated with SN. Interestingly, one of these modules was significantly enriched in transcription factors (TFs). Furthermore, our network analysis predicted several NAC TFs as major hubs underlying SW and SN compensation. Taken together, our study provides novel insights into the molecular factors associated with the SW-SN relationship in rapeseed and identifies TFs as potential targets when improving crop yield.


Assuntos
Brassica napus/genética , Regulação da Expressão Gênica de Plantas , Proteínas de Plantas/metabolismo , Sementes/genética , Transcriptoma , Brassica napus/anatomia & histologia , Brassica napus/crescimento & desenvolvimento , Genótipo , Tamanho do Órgão , Proteínas de Plantas/genética , Locos de Características Quantitativas , Sementes/anatomia & histologia , Sementes/química , Sementes/crescimento & desenvolvimento
17.
Vet Rec ; 189(6): e198, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33899945

RESUMO

BACKGROUND: The association between myocardial parasitic load (MPL) and cardiac biomarkers in Canine Leishmaniasis (CanL) has not been studied. METHODS: Dogs with advanced CanL were prospectively recruited and were included if they were euthanised. Prior to euthanasia these variables were assessed: hematocrit, globulin, creatinine, N-terminal-pro brain natriuretic peptide (NT-proBNP), cardiac troponin I (cTnI), blood pressure, urine protein/creatinine ratio and echocardiographic parameters. A left ventricular (LV) sample was taken for histopathology and MPL evaluation by quantitative PCR. Correlation of MPL with all variables was analysed. Dogs with lower and higher histopathology scores were compared. RESULTS: Ten dogs were included. NT-proBNP was 6946 pmol/ (interquartile range [IQR] 3751-9268 pmol/L) and cTnI 4.56 ng/mL (IQR 0.46-13.1 ng/mL). In all dogs, echocardiography showed an increase in LV thickening, and histopathology revealed moderate to severe lympho-plasmocytic myocarditis and/or myocardial cell degeneration. MPL was 215.53 parasites/gram (IQR 21.2-1372.63 parasites/gram). A strong correlation (p < 0.001; R = 0.90; R2 0.81) with cTnI was observed but correlation with any of the other variables or differences between the two histopathological scores, were not detected. CONCLUSIONS: MPL in dogs with advanced CanL shows variable but generally high levels. A strong association between MPL and cTnI was observed, which encourages the exploration of cTnI as a marker in CanL.


Assuntos
Doenças do Cão , Leishmaniose , Animais , Biomarcadores , Doenças do Cão/parasitologia , Cães , Leishmaniose/veterinária , Carga Parasitária/veterinária , Troponina I
18.
Curr Eye Res ; 46(8): 1223-1226, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33460537

RESUMO

PURPOSE: To investigate whether cessation of MiSight contact lens (CLs) wear for myopia control produces rebound effect. MATERIAL AND METHODS: This study recruited participants who had just completed the MASS Study, a two-year randomized clinical trial designed to assess the efficacy of MiSight® CLs versus distance single vision (SV) spectacles in myopic children. To assess the rebound effect, axial length progression was taken into account in those children that continued one more year of follow-up. At this visit, children were divided into three groups: MiSight-C group, in which children from the original study group continued MiSight CLs wear for the duration of the study; MiSight-D group, in which children from the original study group discontinued MiSight CLs wear in the last year; and SV-C group, in which children from the original control group continued wearing single-vision spectacles for the duration of the study. The last group was considered as the control group. RESULTS: Of the 74 children who completed the MASS study, 55 children completed the 1-year follow-up and were included in the analysis. Thirteen children were included in the MiSight-C group, 18 in the MiSight-D group, and 24 in the Single Vision-C group. Axial length and myopia progression in the last year were 0.15± 0.11 mm, 0.22± 0.11 mm, 0.21± 0.10 mm and -0.37±0.44D, -0.46±0.39D and -0.55±0.45D for the three groups, respectively. No significant differences in axial elongation and myopia progression were found among the three groups of participants. CONCLUSIONS: Over a one-year period, neither myopia progression nor eye growth was faster for the subjects who discontinued MiSight contact lens wear compared to those who continued to wear MiSight contact lenses or those who continued to wear single-vision spectacles, indicating no rebound effect with MiSight contact lenses for 2 years.ClinicalTrials.gov Identifier: NCT01917110.


Assuntos
Lentes de Contato , Miopia/diagnóstico , Miopia/terapia , Procedimentos Ortoceratológicos , Adolescente , Comprimento Axial do Olho/fisiopatologia , Criança , Progressão da Doença , Óculos , Feminino , Seguimentos , Humanos , Masculino , Miopia/fisiopatologia , Estudos Prospectivos , Recidiva , Refração Ocular/fisiologia , Espanha , Acuidade Visual/fisiologia , Suspensão de Tratamento
19.
J Refract Surg ; 36(7): 435-441, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32644165

RESUMO

PURPOSE: To assess the effect of prior myopic ablations on the optical performance of a trifocal diffractive intraocular lens (IOL) and a novel extended depth of focus (EDOF) diffractive design. METHODS: The novel XACT Mono-EDOF ME4 diffractive IOL (Santen Pharmaceutical) and the trifocal diffractive FineVision IOL (PhysIOL) were analyzed standing alone and combined with a simulated myopic corneal ablation. The optical quality of the IOLs in both situations was evaluated with the PMTF optical bench (LAMBDA-X). The through-focus modulation transfer function (MTF) curves and the MTF at three different focal points (+0.50, 0.00, and -0.50 diopters [D]) were recorded. RESULTS: The through-focus MTF curves showed three differentiated peaks for the trifocal IOL and two overlapped peaks for the EDOF IOL. The presence of simulated myopic corneal ablations induces a -0.50 D shift on the overall through-focus curves and softens the multifocal properties of both lenses by decreasing the variations through focus of the MTF. For the analysis of the lenses standing alone, the highest MTF values were obtained for an object vergence of 0.00 D. For a simulated myopic corneal ablation, both IOLs showed better optical quality results at -0.50 D. CONCLUSIONS: The trifocal IOL provides better optical quality at far and near distances when analyzed alone. The EDOF IOL optical properties are more stable when a myopic ablation is introduced. Preoperative calculations of both lenses should consider that prior myopic corneal ablations induce a -0.50 D shift on their far peak quality. [J Refract Surg. 2020;36(7):435-441.].


Assuntos
Córnea/diagnóstico por imagem , Modelos Teóricos , Lentes Intraoculares Multifocais , Miopia/cirurgia , Óptica e Fotônica , Refração Ocular/fisiologia , Humanos , Miopia/fisiopatologia , Desenho de Prótese
20.
J Ophthalmol ; 2019: 4921538, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31360543

RESUMO

OBJECTIVE: The aim of this study was to investigate tear film optical quality dynamics for four types of silicone hydrogel contact lenses (SHCLs) for daily wear over a 15-day period and for different blink rate (BR) patterns. METHODS: A prospective randomized, double-blind, cross-over pilot study including four SHCLs (A: lotrafilcon B (Air Optix plus HydraGlyde, Alcon Laboratories); B: samfilcon A (Ultra, Bausch & Lomb); C: comfilcon A (Biofinity, CooperVision); and D: filcom V3 (Blu:gen, Mark'Ennovy)). Serial measurements of Objective Scatter Index (OSI) using the HD Analyzer (Visiometrics S.L., Terrassa, Spain) were taken at different blinking patterns: blinking every 2.5 seconds (high BRs) and every 9 seconds (low BRs). They were performed during the first visit before CL insertion (baseline), after 20 minutes of CL wear (Day 1), and during the last visit after 8 hours of CL wear on day 15 of use (Day 15). RESULTS: Normal young healthy subjects were recruited and fitted with the four lenses. For low BRs, the mean OSI value increased over time for all CLs and the slope of the curve also increased for all CLs, except for CL D. However, for high BRs, the mean OSI value increased only for CLs B and C and the slope of the curve did not change over time for any of them. CONCLUSIONS: These results suggest that the tear film optical quality dynamics after wearing SCHLs for 15 days seems to undergo a slight deterioration only for lowest BR.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...