1.
Sci Rep ; 9(1): 9927, 2019 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-31289314

RESUMO

The ability to manipulate the structure and function of promising systems via external stimuli is emerging with the development of reconfigurable and programmable multifunctional materials. Increasing antifungal and antitumor activity requires novel, effective treatments to be diligently sought. In this work, the synthesis, characterization, and in vitro biological screening of pure α-Ag2WO4, irradiated with electrons and with non-focused and focused femtosecond laser beams are reported. We demonstrate, for the first time, that Ag nanoparticles/α-Ag2WO4 composite displays potent antifungal and antitumor activity. This composite had an extreme low inhibition concentration against Candida albicans, cause the modulation of α-Ag2WO4 perform the fungicidal activity more efficient. For tumor activity, it was found that the composite showed a high selectivity against the cancer cells (MB49), thus depleting the populations of cancer cells by necrosis and apoptosis, without the healthy cells (BALB/3T3) being affected.


Assuntos
Antifúngicos/farmacologia , Antineoplásicos/farmacologia , Candida albicans/efeitos dos fármacos , Elétrons , Nanopartículas Metálicas/química , Óxidos/química , Prata/química , Tungstênio/química , Neoplasias da Bexiga Urinária/tratamento farmacológico , Animais , Apoptose , Células 3T3 BALB , Proliferação de Células , Humanos , Nanopartículas Metálicas/administração & dosagem , Nanopartículas Metálicas/efeitos da radiação , Camundongos , Óxidos/efeitos da radiação , Prata/efeitos da radiação , Células Tumorais Cultivadas , Tungstênio/efeitos da radiação , Neoplasias da Bexiga Urinária/patologia , Ensaios Antitumorais Modelo de Xenoenxerto
2.
Clin Oral Investig ; 22(2): 733-744, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28667399

RESUMO

OBJECTIVES: The morphology and chemical composition of enamel submitted to different sterilization methods was studied. METHODS: X-ray photoelectron spectroscopy (XPS), field emission gun scanning electron microscopy (FEG-SEM), and energy-dispersive X-ray spectroscopy (EDS) were performed to evaluate 50 bovine enamel specimens sterilized using four methods: microwaving (MI), gamma irradiation (GI), ethylene oxide (EO), and steam autoclave (SA). Non-sterilized specimens were used as control. RESULTS: XPS indicated that the concentration of P (phosphorus), CO3 (carbonate), and CO3/P was not changed in all groups. GI produced no significant change on elemental composition. SA produced the major decrease in calcium (Ca), Ca/P ratio, and increase in N (nitrogen). MI was found to decrease Ca, Ca/P ratio and O (oxygen), and increase in C (carbon) and N. EO produced decrease in Ca and O with increased C concentration. FEG-SEM revealed surface and in-depth morphological changes on SA specimens. Minor surface alterations were observed for EO and for MI groups, and no alteration was observed on GI group. EDS indicated no difference on elemental composition of enamel bulk among groups. CONCLUSIONS: SA produced mineral loss and morphological alterations on surface and in depth. MI and EO sterilization caused mineral loss showing only slight alteration on enamel surface. GI sterilization preserves the morphological characteristics of enamel. The sterilization methods could be classified from lower to high damage as GI < MI < EO < SA. CLINICAL RELEVANCE: This is a comprehensive comparative study where different methods for enamel sterilization were investigated in terms of chemical changes. The results presented here may help researchers to choose the most appropriate method for their research setting and purpose.


Assuntos
Esmalte Dentário/química , Esterilização/métodos , Animais , Bovinos , Técnicas In Vitro , Teste de Materiais , Microscopia Eletrônica de Varredura , Espectroscopia Fotoeletrônica , Espectrometria por Raios X , Propriedades de Superfície
3.
Biofouling ; 29(9): 1057-67, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24025068

RESUMO

This study evaluated the photodynamic inactivation (PDI) mediated by Photodithazine(®) (PDZ) against 15 clinical isolates of Candida albicans, Candida glabrata and Candida tropicalis. Each isolate, in planktonic and biofilm form, was exposed to PDI by assessing a range of PDZ concentrations and light emitting diode fluences. Cell survival of the planktonic suspensions was determined by colony forming units (CFU ml(-1)). The antifungal effects of PDI against biofilms were evaluated by CFU ml(-1) and metabolic assay. Data were analyzed by non-parametric tests (α = 0.05). Regardless of the species, PDI promoted a significant viability reduction of planktonic yeasts. The highest reduction in cell viability of the biofilms was equivalent to 0.9 log10 (CFU ml(-1)) for C. albicans, while 1.4 and 1.5 log10 reductions were obtained for C. tropicalis and C. glabrata, respectively. PDI reduced the metabolic activity of biofilms by 62.1, 76.0, and 76.9% for C. albicans, C. tropicalis, and C. glabrata, respectively. PDZ-mediated PDI promoted significant reduction in the viability of Candida isolates.


Assuntos
Biofilmes/efeitos dos fármacos , Biofilmes/efeitos da radiação , Candida/fisiologia , Fungicidas Industriais/farmacologia , Glucosamina/análogos & derivados , Candida/efeitos dos fármacos , Candida/efeitos da radiação , Candida albicans , Candida glabrata , Candida tropicalis , Relação Dose-Resposta a Droga , Glucosamina/farmacologia , Testes de Sensibilidade Microbiana , Plâncton/efeitos dos fármacos , Plâncton/microbiologia , Plâncton/efeitos da radiação , Especificidade da Espécie
4.
Clin Microbiol Infect ; 18(10): E380-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22731617

RESUMO

In this randomized clinical trial, the clinical and mycological efficacy of Photodynamic Therapy (PDT) was compared with that of topical antifungal therapy for the treatment of denture stomatitis (DS) and the prevalence of Candida species was identified. Patients were randomly assigned to one of two groups (n = 20 each); in the nystatin (NYT) group patients received topical treatment with nystatin (100,000 IU) four times daily for 15 days and in the PDT group the denture and palate of patients were sprayed with 500 mg/L of Photogem(®), and after 30 min of incubation, were illuminated by light emitting-diode light at 455 nm (37.5 and 122 J/cm(2), respectively) three times a week for 15 days. Mycological cultures taken from dentures and palates and standard photographs of the palates were taken at baseline (day 0), at the end of the treatment (day 15) and at the follow-up time intervals (days 30, 60 and 90). Colonies were quantified (CFU/mL) and identified by biochemical tests. Data were analysed by Fisher's exact test, analysis of variance and Tukey tests and κ test (α = 0.05). Both treatments significantly reduced the CFU/mL at the end of the treatments and on day 30 of the follow-up period (p <0.05). The NYT and PDT groups showed clinical success rates of 53% and 45%, respectively. Candida albicans was the most prevalent species identified. PDT was as effective as topical nystatin in the treatment of DS.


Assuntos
Antifúngicos/administração & dosagem , Nistatina/administração & dosagem , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Estomatite sob Prótese/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Candida/classificação , Candida/isolamento & purificação , Candidíase Bucal/tratamento farmacológico , Candidíase Bucal/microbiologia , Candidíase Bucal/terapia , Contagem de Colônia Microbiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Estomatite sob Prótese/microbiologia , Resultado do Tratamento
5.
J Appl Microbiol ; 112(6): 1163-72, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22452416

RESUMO

AIM: This study firstly evaluated the activity of a silver nanoparticle (AgNPs) solution against Candida albicans and then the effect of incorporation of AgNPs into a denture base acrylic resin on the material's hydrophobicity, C. albicans adhesion and biofilm formation. METHODS AND RESULTS: The AgNPs solution was synthesized by chemical reduction and characterized. Minimum inhibitory (MIC) and minimum fungicidal (MFC) concentrations for planktonic cells and sessile cells (MFCs) of the AgNPs solution against C. albicans were determined. Specimens (n = 360) of silver-incorporated acrylic resin at concentrations of 1000, 750, 500, 250 and 30 ppm were also prepared and stored in PBS for 0, 7, 90 and 180 days. Control was acrylic resin without AgNPs (0 ppm). After the storage periods, contact angles were measured and the specimens were used for C. albicans adherence (37°C; 90 min; n = 9) and biofilm formation (37°C; 48 h; n = 9) by XTT reduction assay. MIC, MFC and MFCs values were 3·98, 15·63 and 1000 ppm, respectively. Incorporation of AgNPs reduced the hydrophobicity of the resin. No effect on adherence and biofilm formation was observed. At 90 and 180 days of storage, there was significant increase in adherence and biofilm formation. CONCLUSIONS: Although the AgNPs solution had antifungal activity, no effect on C. albicans adherence and biofilm formation was observed after its incorporation into a denture base resin. SIGNIFICANCE AND IMPACT OF THE STUDY: The synthesized AgNPs solution is a promising antifungal agent, warranting investigations of more efficient methods of incorporation into denture base resins.


Assuntos
Antifúngicos/farmacologia , Biofilmes/efeitos dos fármacos , Candida albicans/fisiologia , Bases de Dentadura/microbiologia , Nanopartículas/microbiologia , Prata/química , Resinas Acrílicas/química , Adesão Celular/efeitos dos fármacos , Nanopartículas/química
6.
Mycoses ; 54(5): e344-51, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20557466

RESUMO

There is a propensity for fungal adherence to the polymethylmethacrylate used for making denture bases. Therefore, this study investigated whether surface modifications with plasma treatments would reduce the adherence of Candida albicans to a denture base resin. Samples (n = 180) with smooth and rough surfaces were made and divided into five groups: control - non-treated; experimental groups - submitted to plasma treatments to obtain surfaces with different hydrophobicities (Ar/50 W; ArO(2) /70 W; AAt/130 W) or with incorporated fluoride (Ar/SF(6) 70 W). Contact angles were measured immediately after treatments and after samples were immersed in water for 48 h. For each group, half the samples were incubated with saliva before the adherence test. The number of adhered C. albicans was evaluated by counting after crystal violet staining. The plasma treatments were effective in modifying the polymethylmethacrylate surface. However, there was a significant alteration in the contact angle measured after immersion in water. No statistically significant difference in the adherence of C. albicans was observed between the experimental and control groups, irrespective of the presence or absence of saliva, and surface roughness.


Assuntos
Candida albicans/fisiologia , Adesão Celular , Bases de Dentadura/microbiologia , Plasma/metabolismo , Polimetil Metacrilato/metabolismo , Adulto , Contagem de Colônia Microbiana , Experimentação Humana , Humanos
7.
J Oral Rehabil ; 35(11): 836-46, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18466276

RESUMO

UNLABELLED: The effectiveness of microwave disinfection of maxillary complete dentures on the treatment of Candida-related denture stomatitis was evaluated. Patients (n = 60) were randomly assigned to one of four treatment groups of 15 subjects each; CONTROL GROUP: patients performed the routine denture care; Mw group: patients had their upper denture microwaved (650 W per 6 min) three times per week for 30 days; group MwMz: patients received the treatment of Mw group in conjunction with topical application of miconazole three times per day for 30 days; group Mz: patients received the antifungal therapy of group MwMz. Cytological smears and mycological cultures were taken from the dentures and the palates of all patients before treatment at day 15 and 30 of treatment and at follow-up (days 60 and 90). The effectiveness of the treatments was evaluated by Kruskal-Wallis and Mann-Whitney tests. Microbial and clinical analysis of the control group demonstrated no significant decrease in the candidal infection over the clinical trial. Smears and cultures of palates and dentures of the groups Mw and MwMz exhibited absence of Candida at day 15 and 30 of treatment. On day 60 and 90, few mycelial forms were observed on 11 denture smears (36.6%) from groups Mw and MwMz, but not on the palatal smears. Miconazole (group Mz) neither caused significant reduction of palatal inflammation nor eradicated Candida from the dentures and palates. Microwaving dentures was effective for the treatment of denture stomatitis. The recurrence of Candida on microwaved dentures at follow-up was dramatically reduced.


Assuntos
Candidíase Bucal/radioterapia , Prótese Total Superior/microbiologia , Desinfecção/métodos , Micro-Ondas , Estomatite sob Prótese/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antifúngicos/uso terapêutico , Candida albicans/isolamento & purificação , Candidíase Bucal/tratamento farmacológico , Desinfetantes de Equipamento Odontológico/uso terapêutico , Feminino , Humanos , Masculino , Miconazol/uso terapêutico , Pessoa de Meia-Idade , Estomatite sob Prótese/tratamento farmacológico , Estomatite sob Prótese/microbiologia
8.
J Oral Rehabil ; 34(3): 222-7, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17302951

RESUMO

Prosthodontics should be one of the means of establishing conditions for the maintenance of periodontal health. The forces applied to the abutment teeth and their effects are very important considerations in the design and construction of the removable partial dentures. This 6-month follow-up clinical study evaluated the degree of mobility of abutment teeth of distal extension and tooth supported removable partial dentures by using Periotest. Two types of clasp design were selected for evaluation. In cases with unilateral and bilateral distal-extension, a clasp design including a T clasp of Roach retentive arm, a rigid reciprocal arm and a mesial rest were used. For the abutments of tooth-supported removable partial dentures, a second clasp design with a cast circumferential buccal retentive arm, a rigid reciprocal clasp arm and a rest adjacent to the edentulous ridges was selected. A total of 68 abutment teeth was analysed. Periotest values were made at the time of denture placement (control) and at 1, 3 and 6 months after the denture placement. The statistical analysis was performed using Friedman test. All analysis was performed at a 0.05 level of significance. The results revelled that no significant changes in tooth mobility were observed during the 6-months follow-up (P > 0.05). In conclusion, our findings suggest that adequate oral hygiene instructions, careful prosthetic treatment planning and regular recall appointments play an important role in preventing changes in abutment tooth mobility caused by removable partial denture placement.


Assuntos
Dente Suporte , Prótese Parcial Removível , Idoso , Fenômenos Biomecânicos , Grampos Dentários , Desenho de Equipamento , Seguimentos , Humanos , Pessoa de Meia-Idade , Periodonto/fisiopatologia , Estresse Mecânico , Mobilidade Dentária/fisiopatologia
9.
J Oral Rehabil ; 31(11): 1085-9, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15525387

RESUMO

The aim of this study was to evaluate the effect of ageing in distilled water on the hardness and compressive strength of a direct composite resin Z100, a feldspatic porcelain (Noritake) and three indirect composites (Artglass, Solidex and Targis). For the Vickers hardness tests, five disk-shaped specimens (2 x 4 mm) of each material were prepared according to the manufacturers' instructions. The hardness tests were conducted using a Vickers diamond indentor. Compressive strength measurements were recorded on cylindrical specimens with a diameter of 6 mm and a length of 12 mm. The compression tests were carried out with a constant cross-head speed of 0.5 mm min(-1) on a mechanical test machine. For each material, 10 specimens were tested after 7 days of dry storage at 37 +/- 1 degrees C and 10 specimens were tested after water storage at 37 +/- 1 degrees C for 180 days. Noritake porcelain specimens showed higher hardness values than the composites. Among the composite materials, Z100 promoted the highest VHN values, regardless of the ageing periods. The results showed that Solidex and Z100 had the highest compressive strength values. Ageing in water reduced the hardness for all composites, but had no long-term effect on the compressive strength.


Assuntos
Resinas Compostas , Força Compressiva , Dureza , Teste de Materiais , Fatores de Tempo
10.
J Oral Rehabil ; 30(11): 1085-9, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14641673

RESUMO

The disinfection of dental prostheses by immersion in a chemical solution should be capable of rapid inactivation of pathogenic microorganisms, without causing any adverse effect on the denture base resins. This study evaluated the effect of disinfection immersion on the transverse strength of two heat-cured resins. The denture base resins (Lucitone 550 and QC 20) were polymerized according to the manufacturers' instructions. After polymerization, the specimens were polished, and then stored in water at 37 degrees C for 50 +/- 2 h prior immersion in one of the following solutions for 10 min: 4% chlorhexidine, 1% sodium hypochlorite and 3.78% sodium perborate. The specimens were submitted to disinfection twice, simulating when dentures come from the patient and before being returned to the patient. Ten specimens were made for each group. The transverse strength was evaluated by a 3-point bend test. The flexural strength of the two denture base acrylic resins evaluated remained unaffected after immersion in the three solutions evaluated. In general, the QC 20 resin specimens exhibited lower transverse strength than the Lucitone 550 resin specimens, regardless of immersion solutions.


Assuntos
Resinas Acrílicas/química , Bases de Dentadura , Desinfetantes/farmacologia , Análise de Variância , Infecção Hospitalar/prevenção & controle , Dentaduras , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Temperatura Alta , Humanos , Controle de Infecções/métodos , Substâncias Macromoleculares , Teste de Materiais/métodos , Estresse Mecânico
11.
J Oral Rehabil ; 30(7): 749-52, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12791163

RESUMO

This investigation studied the effects of disinfectant solutions on the hardness of acrylic resin denture teeth. The occlusal surfaces of 64 resin denture teeth were ground flat with abrasives up to 400-grit silicon carbide paper. Measurements were made after polishing and after the specimens were stored in water at 37 degrees C for 48 h. The specimens were then divided into four groups and immersed in chemical disinfectants (4% chlorhexidine; 1% sodium hypochlorite and sodium perborate) for 10 min. The disinfection methods were performed twice to simulate clinical conditions and hardness measurements were made. Specimens tested as controls were immersed in water during the same disinfection time. Eight specimens were produced for each group. After desinfection procedures, testing of hardness was also performed after the samples were stored at 37 degrees C for 7, 30, 60, 90 and 120 days. Data were analysed using two-way analysis of variance (anova) and Tukey's test at 95% confidence level. According to the results, no significant differences were found between materials and immersion solutions (P > 0.05). However, a continuous decrease in hardness was noticed after ageing (P < 0.05). It was conclude that the surfaces of both acrylic resin denture teeth softened upon immersion in water regardless the disinfecting solution.


Assuntos
Resinas Acrílicas/química , Materiais Dentários/química , Desinfetantes/farmacologia , Análise de Variância , Boratos/farmacologia , Compostos Inorgânicos de Carbono/farmacologia , Clorexidina/farmacologia , Porcelana Dentária/farmacologia , Dureza/efeitos dos fármacos , Humanos , Teste de Materiais , Compostos de Silício/farmacologia , Hipoclorito de Sódio/farmacologia , Propriedades de Superfície/efeitos dos fármacos , Clareamento Dental
12.
J Oral Rehabil ; 30(5): 532-6, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12752936

RESUMO

This investigation evaluated the effectiveness of an infection control protocol for cleansing and disinfecting removable dental prostheses. Sixty-four dentures were rubbed with sterile cotton swab immediately after they had been taken from patients' mouths. Samples were individually placed in the culture medium and immediately incubated at 37 +/- 2 degrees C. The dentures were scrubbed for 1 min with 4% chlorhexidine, rinsed for 1 min in sterile water and placed for 10 min in one of the following immersion solutions: 4% chlorhexidine gluconate, 1% sodium hypochlorite, Biocide (iodophors) and Amosan (alkaline peroxide). After the disinfection procedures, the dentures were immersed in sterile water for 3 min, reswabbed and the samples were incubated. All samples obtained in the initial culture were contaminated with micro-organisms. All the lower dentures immersed in Biocide showed positive growth, and the upper dentures were positive for growth in six of eight dentures. The 4% chlorhexidine gluconate, 1% sodium hypochlorite and Amosan solutions have been proved effective to reduce the growth of the micro-organisms in the 10 min immersion period. The protocol evaluated in this study seems to be a viable method to prevent cross-contamination between dental personnel and patients.


Assuntos
Anti-Infecciosos Locais , Clorexidina/análogos & derivados , Prótese Dentária , Higienizadores de Dentadura , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Clorexidina/análise , Feminino , Humanos , Masculino , Hipoclorito de Sódio/análise
13.
J Prosthet Dent ; 86(6): 574-7, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11753305

RESUMO

The orofacial characteristics of ectodermal dysplasia include anodontia or hypodontia, hypoplastic conical teeth, underdevelopment of the alveolar ridges, frontal bossing, a depressed nasal bridge, protuberant lips, and hypotrichosis. Patients with this disease often need complex prosthetic treatment. The options for a definitive treatment plan may include fixed, removable, or implant-supported prostheses, singly or in combination. However, financial constraints and other priorities can prevent patients from choosing the most desirable treatment. This clinical report describes the diagnosis and treatment of ectodermal dysplasia in an 18-year-old man. The treatment included interim removable partial dentures fabricated to establish an acceptable therapeutic occlusal vertical dimension, followed by definitive overlay removable partial dentures and composite restorations.


Assuntos
Anodontia/terapia , Assistência Odontológica para Doentes Crônicos , Revestimento de Dentadura , Prótese Parcial Removível , Displasia Ectodérmica/complicações , Adolescente , Anodontia/etiologia , Prótese Parcial Temporária , Displasia Ectodérmica/terapia , Humanos , Masculino , Mandíbula , Maxila
14.
J Oral Rehabil ; 28(12): 1153-7, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11874516

RESUMO

Direct relining of dentures made with hard chairside reline resins is faster than laboratory-processed reline systems and the patient is not without the prosthesis for the time necessary to perform the laboratory procedures. However, a weak bond between the autopolymerizing acrylic reline resins and the denture base material has been observed. This study evaluated the effect of six different surface treatments on the bond strength between a hard chairside reline acrylic resin and a heat-cured acrylic resin. Specimens of the heat-cured acrylic resin were divided into seven groups. One of these groups remained intact. In the other groups, a 10-mm square section was removed from the centre of each specimen. The bonding surfaces were then treated with (i) methyl methacrylate monomer, (ii) isobutyl methacrylate monomer, (iii) chloroform, (iv) acetone, (v) experimental adhesive and (vi) no surface treatment -- control group. Kooliner acrylic resin was packed into the square sections and polymerized. The bonding strength was evaluated by a three-point loading test. The results were submitted to one-way analysis of variance (ANOVA) followed by a Tukey multiple range test at a 5% level of significance. No significant difference was found between the surface treatment with Lucitone 550 monomer or chloroform, but both were stronger than the majority of the other groups. The bond strength provided by all the surface treatments was lower than that of the intact heat-cured resin.


Assuntos
Resinas Acrílicas/química , Colagem Dentária , Bases de Dentadura , Reembasadores de Dentadura , Reembasamento de Dentadura , Acetona/química , Adesivos/química , Análise de Variância , Clorofórmio/química , Temperatura Alta , Humanos , Teste de Materiais , Metilmetacrilato/química , Ácidos Polimetacrílicos/química , Solventes/química , Estatística como Assunto , Estresse Mecânico , Propriedades de Superfície
15.
Int J Prosthodont ; 13(5): 383-6, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11203658

RESUMO

PURPOSE: This investigation studied the effects of 3 surface treatments on the shear bond strength of a light-activated composite resin bonded to acrylic resin denture teeth. MATERIALS AND METHODS: The occlusal surfaces of 30 acrylic resin denture teeth were ground flat with up to 400-grit silicon carbide paper. Three different surface treatments were evaluated: (1) the flat ground surfaces were primed with methyl methacrylate (MMA) monomer for 180 seconds; (2) light-cured adhesive resin was applied and light polymerized according to the manufacturer's instructions; and (3) treatment 1 followed by treatment 2. The composite resin was packed on the prepared surfaces using a split mold. The interface between tooth and composite was loaded at a cross-head speed of 0.5 mm/min until failure. RESULTS: Analysis of variance indicated significant differences between the surface treatments. Results of mean comparisons using Tukey's test showed that significantly higher shear bond strengths were developed by bonding composite resin to the surfaces that were previously treated with MMA and then with the bonding agent when compared to the other treatments. CONCLUSION: Combined surface treatment of MMA monomer followed by application of light-cured adhesive resin provided the highest shear bond strength between composite resin and acrylic resin denture teeth.


Assuntos
Resinas Acrílicas/química , Resinas Compostas/química , Colagem Dentária , Dente Artificial , Agentes Molhantes/química , Adesivos/química , Análise de Variância , Teste de Materiais , Metilmetacrilato/química , Distribuição Aleatória , Cimentos de Resina/química , Estatísticas não Paramétricas , Resistência à Tração
16.
J Oral Rehabil ; 26(8): 631-4, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10447815

RESUMO

Due to gradual resorption of the edentulous ridge bone, removable prostheses often require denture base relines to improve fit and stability. This research evaluated the bond strength between one heat-cured acrylic resin (Lucitone 550(R)) and two hard chairside reline resins, after two different periods of storage in water (50 h and 30 days). The bond strength was evaluated using a tensile test. The mode of failure, adhesive or cohesive, was also recorded. The results submitted to the Kruskal-Wallis test indicated that the highest tensile strengths were achieved with intact Lucitone 550(R) denture base resin in both periods of storage in water. After 50 h of storage in water, Duraliner II(R) reline material exhibited the highest bond strength to the denture base resin. After 30 days of storage in water, Duraliner II(R) reline resin demonstrated a significant reduction in adhesion, showing lower tensile bond strength than Kooliner(R) material. Both hard chairside reline materials failed adhesively across Lucitone 550(R) denture base resin, in both periods of time.


Assuntos
Resinas Acrílicas/química , Reembasadores de Dentadura , Reembasamento de Dentadura , Água/química , Adesividade , Colagem Dentária , Bases de Dentadura , Retenção de Dentadura , Humanos , Teste de Materiais , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
17.
J Prosthet Dent ; 80(4): 434-8, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9791790

RESUMO

STATEMENT OF PROBLEM: Because water sorption of autopolymerizing acrylic reline resins is accompanied by volumetric change, it is a physical property of importance. As residual monomer leaches into the oral fluids and causes tissue irritation, low solubility of these resins is desired. Another requirement is a satisfactory bond between the autopolymerizing acrylic resins and the denture base acrylic resin. PURPOSE: This study compared the water sorption, solubility, and the transverse bond strength of 2 autopolymerizing acrylic resins (Duraliner II and Kooliner) and 1 heat-polymerizing acrylic resin (Lucitone 550). MATERIAL AND METHODS: The water sorption and solubility test was performed as per International Standards Organization Specification No. 1567 for denture base polymers. Bond strengths between the autopolymerizing acrylic resins and the heat-polymerizing acrylic resin were determine with a 3-point loading test made on specimens immersed in distilled water at 37 degrees C for 50 hours and for 30 days. Visual inspection determined whether failures were adhesive or cohesive. RESULTS: Duraliner II acrylic resin showed significantly lower water sorption than Kooliner and Lucitone 550 acrylic resins. No difference was noted in the solubility of all materials. Kooliner acrylic resin demonstrated significantly lower transverse bond strength to denture base acrylic resin and failed adhesively. The failures seen with Duraliner II acrylic resin were primarily cohesive in nature. CONCLUSIONS: Autopolymerizing acrylic reline resins met water sorption and solubility requirements. However, Kooliner acrylic resin demonstrated significantly lower bond strength to denture base acrylic resin.


Assuntos
Resinas Acrílicas/química , Colagem Dentária , Água/química , Absorção , Adsorção , Análise de Variância , Bases de Dentadura , Reembasamento de Dentadura , Temperatura Alta , Humanos , Teste de Materiais , Solubilidade , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo
18.
J Prosthet Dent ; 77(3): 328-31, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9069091

RESUMO

Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to a loss of chewing efficiency and a loss of vertical dimension of occlusion. The use of metal occlusal surfaces on the acrylic resin denture teeth will minimize occlusal wear. Several articles have described methods to construct metal occlusal surfaces; however, these methods are time-consuming, costly, and sometimes considered to be unesthetic. These methods also require that the patient be without the prosthesis for the time necessary to perform the laboratory procedures. This article presents a quick, simple, and relatively inexpensive procedure for construction of composite occlusal surfaces on complete and partial dentures.


Assuntos
Resinas Compostas , Dente Artificial , Resinas Acrílicas , Planejamento de Dentadura , Humanos , Tecnologia Odontológica/métodos
19.
J Prosthet Dent ; 76(4): 414-7, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8897299

RESUMO

The selection and use of hard chairside reline resins must be made with regard to dimensional stability, which will influence the accuracy of fit of the denture base. This study compared the dimensional change of two hard chairside reline resins (Duraliner II and Kooliner) and one heat-curing denture base resin (Lucitone 550). A stainless steel mold with reference dimensions (AB, CD) was used to obtain the samples. The materials were processed according to the manufacturer's recommendations. Measurements of the dimensions were made after processing and after the samples had been stored in distilled water at 37 degrees C for eight different periods of time. The data were recorded and then analyzed with analysis of variance. All materials showed shrinkage immediately after processing (p < 0.05). The only resin that exhibited shrinkage after 60 days of storage in water was Duraliner II; these changes could be clinically significant in regard of tissue fit.


Assuntos
Resinas Acrílicas/química , Bases de Dentadura , Reembasadores de Dentadura , Reembasamento de Dentadura , Análise de Variância , Humanos , Polímeros/química , Água/química