Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 24(1): 293, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844866

RESUMO

Patients with previous interatrial shunt device (IASD) implantation may face greater challenges during future left atrial interventional procedures. Herein, we report the first case of left atrial appendage closure (LAAC) in a patient with previous IASD implantation. The patient successfully underwent LAAC using the LAmbre device without complications.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Masculino , Feminino , Ecocardiografia Transesofagiana , Idoso , Função do Átrio Esquerdo , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Forame Oval Patente/fisiopatologia , Forame Oval Patente/cirurgia , Oclusão do Apêndice Atrial Esquerdo
2.
Int J Cardiol ; 409: 132201, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38782071

RESUMO

BACKGROUND: To date, whether ascending aorta dilation (AAD) should be considered a contraindication for transcatheter aortic valve replacement (TAVR) remains a topic of debate.. OBJECTIVE: The study investigated the clinical outcome of TAVR in patients with bicuspid aortic valve stenosis (BAV-AS) complicated by AAD. METHODS: We included patients with BAV-AS who underwent TAVR between 2012 and 2019. We collected patient perioperative clinical data., tracked clinical outcomes for over four years post-TAVR, and obtained echocardiography images one year postoperatively. The Kaplan-Meier method was employed for analyzing both unadjusted and adjusted survival data, which was compared using the log-rank test. COX regression and nomograms were used to assess the impact of AAD on post-TAVR clinical outcomes in patients with aortic stenosis (AS), with all-cause mortality as the primary clinical endpoint. RESULTS: A total of 111 BAV patients were included in this study. Long-term follow-up showed an increased mortality risk in patients with BAV-AAD (adjusted Kaplan-Meier analysis: P = .02/0.001). Cox correlation analysis indicated that age (OR = 1.137; P = .034), AAD (OR = 3.51; P = .038), and postoperative left ventricular pressure (LVSP) (OR: 0.959; P = .044) were predictive factors for mortality more than four years after TAVR in patients with BAV. The area under the curve of the Nomogram predicting long-term survival for the training set of patients based on the above metrics was 0.845 (95% CI: 0.696-0.994). Short-term cardiac ultrasound follow-up showed a more rapid rate of AA expansion (0.29 [0-0.34] vs. -1 [-3.3-1] mm/month, P = .001) and a smaller proportion of AA diameter reduction (7.1% vs. 53.7%, P = .001) in patients who died. CONCLUSIONS: Patients with BAV-AAD-AS treated with TAVR have an increased risk of long-term mortality, and clinical prediction models, including AAD age and postoperative LVSP, may predict long-term patient survival. CONDENSED ABSTRACT: The study investigated the clinical outcome of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (BAV-AS) complicated by ascending aorta dilation (AAD). Patients with BAV-AAD-AS treated with TAVR have an increased risk of long-term mortality. AAD, age and postoperative LVSP, may predict long-term patient survival. Short-term cardiac ultrasound follow-up showed a more rapid rate of AA expansion and a smaller proportion of AA diameter reduction in patients who died. A high postoperative AAD expansion rate may indicate an adverse clinical outcome. Surgery regimens for tolerable BAV-AADs and can be considered as a treatment option.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Idoso , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/complicações , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Resultado do Tratamento , Seguimentos , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Fatores de Tempo , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...