Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
1.
J Am Coll Cardiol ; 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39222896

RESUMO

BACKGROUND: TRILUMINATE Pivotal is a prospective, randomized, controlled study of patients with severe tricuspid regurgitation (TR). Venous congestion due to TR may lead to end-organ dysfunction and failure. The potential to reverse or stop further deterioration in end-organ function is an important goal of treatment. OBJECTIVES: Examine changes in end-organ function after tricuspid transcatheter edge-to-edge repair (TEER) and assess the association of baseline end-organ function with heart failure (HF) hospitalizations and mortality. METHODS: Subjects were randomized 1:1 to either the TEER group (TriClip™ System + medical therapy) or Control group (medical therapy alone). Laboratory assessments and TR grading were performed at baseline and at all follow-up visits (discharge, 30 days, 6 months, and 12 months). An independent echocardiography core laboratory assessed TR severity and an independent clinical events committee adjudicated adverse events. RESULTS: 572 subjects were enrolled and randomized (285 TEER, 287 Control). Patients with moderate to severe end-organ impairment (eGFR <45 ml/min/1.73m2 or MELD-XI >15) at baseline had increased incidence of HF hospitalization and death through 12 months, regardless of treatment. There were no statistically significant differences between TEER and Control in eGFR or MELD-XI at 12 months. In subgroup analyses examining only successful TEER patients (moderate or less TR at discharge) compared to control patients, as well as when censoring patients with normal baseline values, both eGFR (+3.55 ± 1.04 vs 0.07 ± 1.10 , p=0.022) and MELD-XI (-0.52 ± 0.18 vs 0.34 ± 0.18, p=0.0007) improved. CONCLUSIONS: Baseline end-organ function were associated with HF hospitalization and death in patients with severe TR. At 12 months, eGFR and MELD-XI scores were not statistically significantly different between the overall TEER and Control groups. In patients who had successful TEER, statistically significant, yet small, favorable changes occurred for both eGFR and MELD-XI. Further investigation is needed to assess whether these changes in end-organ function after successful TEER are clinically meaningful and reduce HF hospitalization or death.

2.
J Soc Cardiovasc Angiogr Interv ; 3(5): 101345, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-39132458

RESUMO

Background: Transcatheter edge-to-edge repair (TEER) improved outcomes in patients with heart failure (HF) and severe secondary mitral regurgitation (SMR) compared with guideline-directed medical therapy (GDMT) alone regardless of the severity of baseline left ventricular ejection fraction (LVEF). The study aimed to evaluate the effect of early changes in LVEF after TEER and GDMT alone in patients with HF and severe SMR. Methods: Within the COAPT trial, we evaluated outcomes according to changes in LVEF from baseline to 30 days. The primary outcome was all-cause death or HF hospitalization (HFH) between 30 days and 2 years. Results: Among 432 patients with paired echocardiographic data, 182 (42.1%) had increased LVEF (LVEF change 6.0% ± 4.9%) and 250 (57.9%) had a decrease or no change in LVEF (LVEF change -6.6% ± 5.6%) from baseline to 30 days. LVEF at 30 days increased more frequently with GDMT alone compared with TEER plus GDMT (51.4% vs 33.0%; P = .0001). Between 30 days and 2 years, there were no significant differences in death or HFH in the increase LVEF and the decrease LVEF groups (58.8% vs 51.4%; multivariable-adjusted HR, 0.97; 95% CI, 0.87-1.08; P = .59). TEER plus GDMT reduced the 30-day to 2-year rate of death or HFH compared with GDMT alone consistently in patients with increase LVEF and decrease LVEF (Pint = 0.75). Conclusions: Among patients with HF and severe SMR, early improvements in LVEF were more frequent with GDMT alone compared with TEER plus GDMT but were not associated with subsequent outcomes at 2 years. TEER reduced death or HFH during 2-year follow-up irrespective of early LVEF changes.

3.
Circulation ; 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39101203

RESUMO

BACKGROUND: Previous transcatheter valve therapy registry analyses of transcatheter mitral valve in valve (MViV) replacement of degenerated bioprosthesis reported early experience in the United States. Given recent increases in transseptal MViV volumes and introduction of the SAPIEN 3 Ultra valve, it is important to determine contemporary outcomes for patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV replacement. METHODS: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy Registry was used to extract data for all patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV from 2015 to September 2022. Primary efficacy outcome was 1-year all-cause mortality. Secondary end points included 30-day mortality, functional class, quality of life, and mitral valve performance. Primary safety outcomes were device success and in-hospital complications. RESULTS: A total of 4243 patients with a mean STS score of 9.2±7.7 underwent transseptal MViV at 455 sites. The rate of Mitral Valve Academic Research Consortium technical (96.6%) success was high, and procedural complications were low. All-cause in-hospital, 30-day, and 1-year mortality rates were 3.2%, 4.3%, and 13.4%, respectively. Significant improvements in New York Heart Association class (New York Heart Association I/II, 18% to 87%) and quality of life (Kansas City Cardiomyopathy Questionnaire score, 38 to 78) were noted at 1 year (P<0.0001 for both) after MViV. Upon stratifying by STS scores, it was observed that the low-risk group (STS<4) had a significantly lower in-hospital mortality rate of 0.4%, whereas the intermediate-risk group (STS, 4-8) had an in-hospital mortality rate of 1.9%. From 2015 to 2022, the number of transseptal MViV cases/year increased significantly, whereas procedure times, length of stay, and intensive care unit hours shortened significantly. At the same time, there was a significant trend toward reduced in-hospital (P=0.0005), 30-day (P=0.004), and 1-year mortality rates (P=0.01). CONCLUSIONS: This multicenter, prospective study reports excellent procedural outcomes, 1-year mortality rates, and a significant improvement in quality of life for patients undergoing transseptal MViV in the contemporary era. Patients in the low-risk and intermediate-risk STS score categories had significantly better outcomes compared with those in the high-risk category. MViV is a reasonable therapy for the majority of patients with degenerated bioprosthetic mitral valves, who are anatomical candidates.

5.
Eur Heart J ; 45(33): 3031-3041, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38747561

RESUMO

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all [100%; 95% confidence interval (CI) 94%-100.0%, P < .001] patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 [98.3%; 95% CI (91.1%-100%)] patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1%-99.0%). Within 90 days, freedom from mortality was 95% [95% CI (86.1%-99.0%)], without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favourable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Idoso , Estudos Prospectivos , Estenose da Valva Aórtica/cirurgia , Falha de Prótese , Desenho de Prótese , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Oclusão Coronária/cirurgia , Complicações Pós-Operatórias/epidemiologia
6.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599690

RESUMO

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Cateterismo Cardíaco/métodos
7.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
8.
Circ Cardiovasc Interv ; 17(2): e013298, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38235547

RESUMO

BACKGROUND: Frailty associates with worse outcomes after transcatheter aortic valve replacement (TAVR). Sarcopenia underlies frailty, but the association between a comprehensive assessment of sarcopenia-muscle mass, strength, and performance-and outcomes after TAVR has not been examined. METHODS: From a multicenter prospective registry of patients with symptomatic severe aortic stenosis undergoing TAVR, 445 who had a preprocedure computed tomography and clinical assessment of frailty were included. Cross-sectional muscle (psoas and paraspinal) areas were measured on computed tomography and indexed to height. Gait speed and handgrip strength were obtained, and patients were dichotomized into fast versus slow; strong versus weak; and normal versus low muscle mass. As measures of body composition, cross-sectional fat (subcutaneous and visceral) was measured and indexed to height. RESULTS: The frequency of patients who were slow, weak, and had low muscle mass was 56%, 59%, and 42%, respectively. Among the 3 components of sarcopenia, only slower gait speed (muscle performance) was independently associated with increased post-TAVR mortality (adjusted hazard ratio, 1.12 per 0.1 m/s decrease [95% CI, 1.04-1.21]; P=0.004; adjusted hazard ratio, 1.38 per 1 SD decrease [95% CI, 1.11-1.72]; P=0.004). Meeting multiple sarcopenia criteria was not associated with higher mortality risk than fewer. Lower indexed visceral fat area (adjusted hazard ratio, 1.48 per 1 SD decrease [95% CI, 1.15-1.89]; P=0.002) was associated with mortality but indexed subcutaneous fat was not. Death occurred in 169 (38%) patients. CONCLUSIONS: Among patients with symptomatic severe aortic stenosis and comprehensive sarcopenia and body composition phenotyping, gait speed was the only sarcopenia measure associated with post-TAVR mortality. Lower visceral fat was also associated with increased risk pointing to an obesity paradox also observed in other patient populations. These findings reinforce the clinical utility of gait speed as a measure of risk and a potential target for adjunctive interventions alongside TAVR to optimize clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Sarcopenia , Substituição da Valva Aórtica Transcateter , Humanos , Sarcopenia/diagnóstico por imagem , Sarcopenia/complicações , Fragilidade/diagnóstico , Fragilidade/complicações , Resultado do Tratamento , Força da Mão , Estudos Transversais , Medição de Risco , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Composição Corporal , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
9.
Circulation ; 149(10): 734-743, 2024 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-37874908

RESUMO

BACKGROUND: Atrial fibrillation (AF) is common in patients undergoing transcatheter aortic valve replacement (TAVR) and is associated with increased risk of bleeding and stroke. While left atrial appendage occlusion (LAAO) is approved as an alternative to anticoagulants for stroke prevention in patients with AF, placement of these devices in patients with severe aortic stenosis, or when performed at the same time as TAVR, has not been extensively studied. METHODS: WATCH-TAVR (WATCHMAN for Patients with AF Undergoing TAVR) was a multicenter, randomized trial evaluating the safety and effectiveness of concomitant TAVR and LAAO with WATCHMAN in AF patients. Patients were randomized 1:1 to TAVR + LAAO or TAVR + medical therapy. WATCHMAN patients received anticoagulation for 45 days followed by dual antiplatelet therapy until 6 months. Anticoagulation was per treating physician preference for patients randomized to TAVR + medical therapy. The primary noninferiority end point was all-cause mortality, stroke, and major bleeding at 2 years between the 2 strategies. RESULTS: The study enrolled 349 patients (177 TAVR + LAAO and 172 TAVR + medical therapy) between December 2017 and November 2020 at 34 US centers. The mean age of patients was 81 years, and the mean scores for CHA2DS2-VASc and HAS-BLED (Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile INR, Elderly, Drugs/alcohol concomitantly) were 4.9 and 3.0, respectively. At baseline, 85.4% of patients were taking anticoagulants and 71.3% patients were on antiplatelet therapy. The cohorts were well-balanced for baseline characteristics. The incremental LAAO procedure time was 38 minutes, and the median contrast volume used for combined procedures was 119 mL versus 70 mL with TAVR alone. At the 24-month follow-up, 82.5% compared with 50.8% of patients were on any antiplatelet therapy, and 13.9% compared with 66.7% of patients were on any anticoagulation therapy in TAVR + LAAO compared with TAVR + medical therapy group, respectively. For the composite primary end point, TAVR + LAAO was noninferior to TAVR + medical therapy (22.7 versus 27.3 events per 100 patient-years for TAVR + LAAO and TAVR + medical therapy, respectively; hazard ratio, 0.86 [95% CI, 0.60-1.22]; Pnoninferiority<0.001). CONCLUSIONS: Concomitant WATCHMAN LAAO and TAVR is noninferior to TAVR with medical therapy in severe aortic stenosis patients with AF. The increased complexity and risks of the combined procedure should be considered when concomitant LAAO is viewed as an alternative to medical therapy for patients with AF undergoing TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03173534.


Assuntos
Estenose da Valva Aórtica , Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/induzido quimicamente , Anticoagulantes/efeitos adversos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
10.
JACC Case Rep ; 23: 101979, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37954956
11.
Artigo em Inglês | MEDLINE | ID: mdl-37962288

RESUMO

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

12.
JACC Cardiovasc Interv ; 16(21): 2615-2627, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37968032

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. OBJECTIVES: This study aimed to determine whether device position and asymmetry are associated with these outcomes. METHODS: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. RESULTS: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). CONCLUSIONS: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.


Assuntos
Fibrilação Atrial , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Constrição Patológica/etiologia , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Hemodinâmica , Sistema de Registros , Desenho de Prótese
13.
JACC Cardiovasc Interv ; 16(23): 2820-2832, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37905772

RESUMO

BACKGROUND: Favorable 6-month outcomes from the CLASP IID Registry (Edwards PASCAL transcatheter valve repair system pivotal clinical trial) demonstrated that mitral valve transcatheter edge-to-edge repair with the PASCAL transcatheter valve repair system is safe and beneficial for treating prohibitive surgical risk degenerative mitral regurgitation (DMR) patients with complex mitral valve anatomy. OBJECTIVES: The authors sought to assess 1-year safety, echocardiographic and clinical outcomes from the CLASP IID Registry. METHODS: Patients with 3+ or 4+ DMR who were at prohibitive surgical risk, had complex mitral valve anatomy based on the MitraClip Instructions for Use, and deemed suitable for treatment with the PASCAL system were enrolled prospectively. Safety, clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. Study oversight included a central screening committee, echocardiographic core laboratory, and clinical events committee. RESULTS: Ninety-eight patients were enrolled. One-year Kaplan-Meier (KM) estimates of freedom from composite major adverse events, all-cause mortality, and heart failure hospitalization were 83.5%, 89.3%, and 91.5%, respectively. Significant mitral regurgitation (MR) reduction was achieved at 1 year (P < 0.001 vs baseline) including 93.2% at MR ≤2+ and 57.6% at MR ≤1+ with improvements in related echocardiographic measures. NYHA functional class and Kansas City Cardiomyopathy Questionnaire score also improved significantly (P < 0.001 vs baseline). CONCLUSIONS: At 1 year, treatment with the PASCAL system demonstrated safety and significant MR reduction, with continued improvement in clinical, echocardiographic, functional, and quality-of-life outcomes, illustrating the value of the PASCAL system in the treatment of prohibitive surgical risk patients with 3+ or 4+ DMR and complex mitral valve anatomy.


Assuntos
Cateterismo Cardíaco , Insuficiência da Valva Mitral , Humanos , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Ensaios Clínicos como Assunto
14.
J Am Coll Cardiol ; 82(13): 1281-1297, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37730284

RESUMO

BACKGROUND: Real-world applicability of the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) randomized controlled trial (RCT) has been debated because of careful patient selection and the contrasting results of the MITRA-FR (Multicentre Study of Percutaneous Mitral Valve Repair MitraClip Device in Patients with Severe Secondary Mitral Regurgitation) RCT. OBJECTIVES: The COAPT-PAS (COAPT Post-Approval Study) was initiated to assess the safety and effectiveness of the MitraClip in patients with secondary mitral regurgitation (SMR). METHODS: COAPT-PAS is a prospective, single-arm, observational study of 5,000 consecutive patients with SMR treated with the MitraClip at 406 U.S. centers participating in the TVT (Transcatheter Valve Therapy) registry from 2019 to 2020. The 1-year outcomes from the COAPT-PAS full cohort and the COAPT-like and MITRA-FR-like subgroups who met RCT inclusion/exclusion criteria are reported. RESULTS: Patients in the COAPT-PAS had more comorbidities, more severe HF and functional limitations, and less guideline-directed medical therapy than those in the COAPT or MITRA-FR RCTs. Patients in the COAPT-PAS full cohort and the COAPT-like (n = 991) and MITRA-FR-like (n = 917) subgroups achieved a 97.7% MitraClip implant rate, a similar and durable reduction of mitral regurgitation to ≤2+ at 1 year (90.7%, 89.7%, and 86.6%, respectively), a large improvement in quality of life at 1 year (Kansas City Cardiomyopathy Questionnaire +29 COAPT-PAS, +27 COAPT-like, and +33 MITRA-FR-like), faster procedure times, similar or lower clinical event rates compared with the RCTs' MitraClip arms, and lower clinical event rates than the RCTs' guideline-directed medical therapy only arms. One-year heart failure hospitalizations was 18.9% in COAPT-PAS, 19.7% in COAPT-like compared with 24.9% in COAPT-RCT, and 28.7% in COAPT-PAS-MITRA-FR-like compared with 47.4% in MITRA-FR-RCT. CONCLUSIONS: This large, contemporary, real-world study reinforces the safety and effectiveness of the MitraClip System in patients with SMR, including those who met the COAPT or MITRA-FR RCT inclusion/exclusion criteria and patients excluded from the RCTs.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Hospitalização , Avaliação de Resultados em Cuidados de Saúde , Seleção de Pacientes
15.
Struct Heart ; 7(5): 100204, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37745681
16.
JACC Cardiovasc Interv ; 16(18): 2211-2227, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37758379

RESUMO

BACKGROUND: The MITRAL (Mitral Implantation of Transcatheter Valves) trial is the first prospective trial to evaluate the safety and feasibility of balloon-expandable aortic transcatheter heart valves in patients with failed surgical bioprostheses or annuloplasty rings and severe mitral annular calcification treated with mitral valve-in-valve (MViV), valve-in-ring (MViR), or valve-in-mitral annular calcification (ViMAC). OBJECTIVES: The aim of this study was to evaluate 5-year outcomes among these patients. METHODS: A multicenter prospective study was conducted among patients at high surgical risk at 13 U.S. sites. Patients underwent MViV (n = 30), MViR (n = 30), or ViMAC (n = 31) and were followed annually for 5 years. Kansas City Cardiomyopathy Questionnaire scores were obtained at baseline and follow-up visits. Echocardiograms were analyzed at independent core laboratories. RESULTS: A total of 91 patients underwent transcatheter mitral valve replacement (February 2015 to December 2017). The mean age was 74.3 ± 8.9 years. At 5-year follow-up, the lowest all-cause mortality was observed in the MViV group (21.4%), 94.7% of patients were in NYHA functional class I or II, and the mean mitral gradient was 6.6 ± 2.5 mm Hg. The MViR and ViMAC groups had higher all-cause mortality (65.5% and 67.9%), most survivors were in NYHA functional classes I and II (50% and 55.6%), and mean mitral gradients remained stable (5.8 ± 0.1 and 6.7 ± 2.5 mm Hg). Significant improvements in Kansas City Cardiomyopathy Questionnaire scores were observed when all 3 arms were pooled. CONCLUSIONS: MViV, MViR, and ViMAC procedures were associated with sustained improvement of heart failure symptoms and quality of life among survivors at 5 years. Transcatheter heart valve function remained stable in all 3 groups. Patients treated with MViV had excellent survival at 5 years, whereas survival was lower in the MViR and ViMAC groups, consistent with underlying disease severity. Patients with more residual mitral regurgitation had higher mortality.


Assuntos
Calcinose , Cardiomiopatias , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Doenças Vasculares , Humanos , Idoso , Idoso de 80 Anos ou mais , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Calcinose/cirurgia , Doenças Vasculares/etiologia
17.
Circ Cardiovasc Interv ; 16(8): e012875, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37503662

RESUMO

BACKGROUND: Depression and cognitive dysfunction (CD) are not routinely screened for in patients before transcatheter aortic valve replacement (TAVR) and their association with postprocedural outcomes is poorly understood. The objectives of this study are to determine the prevalence of depression and CD in patients with aortic stenosis undergoing TAVR and evaluate their association with mortality and quality of life. METHODS: We analyzed a prospective, multicenter TAVR registry that systematically screened patients for preexisting depression and CD with the Patient Health Questionnaire-2 and Mini-Cog, respectively. The associations with mortality were assessed with Cox proportional hazard models and quality of life (Kansas City Cardiomyopathy Questionnaire and EuroQol visual analogue scale) were evaluated using multivariable ordinal regression models. RESULTS: A total of 884 patients were included; median follow-up was 2.88 years (interquartile range=1.2-3.7). At baseline, depression was observed in 19.6% and CD in 31.8%. In separate models, after adjustment, depression (HR, 1.45 [95% CI, 1.13-1.86]; P<0.01) and CD (HR, 1.27 [95% CI, 1.02-1.59]; P=0.04) were each associated with increased mortality. Combining depression and CD into a single model, mortality was greatest among those with both depression and CD (n=62; HR, 2.06 [CI, 1.44-2.96]; P<0.01). After adjustment, depression was associated with 6.6 (0.3-13.6) points lower on the Kansas City Cardiomyopathy Questionnaire 1-year post-TAVR and 6.7 (0.5-12.7) points lower on the EuroQol visual analogue scale. CD was only associated with lower EuroQol visual analogue scale. CONCLUSIONS: Depression and CD are common in patients that undergo TAVR and are associated with increased mortality and worse quality of life. Depression may be a modifiable therapeutic target to improve outcomes after TAVR.


Assuntos
Estenose da Valva Aórtica , Cardiomiopatias , Disfunção Cognitiva , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Qualidade de Vida , Estudos Prospectivos , Depressão/diagnóstico , Depressão/epidemiologia , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/epidemiologia , Disfunção Cognitiva/etiologia , Assistência Centrada no Paciente , Cardiomiopatias/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
18.
J Am Heart Assoc ; 12(14): e029504, 2023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37421291

RESUMO

Background The incidence and implications of worsening renal function (WRF) after mitral valve transcatheter edge-to-edge repair (TEER) in patients with heart failure (HF) are unknown. Therefore, the aim of this study was to determine the proportion of patients with HF and secondary mitral regurgitation who develop persistent WRF within 30 days following TEER, and whether this development portends a worse prognosis. Methods and Results In the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial, 614 patients with HF and severe secondary mitral regurgitation were randomized to TEER with the MitraClip plus guideline-directed medical therapy (GDMT) versus GDMT alone. WRF was defined as serum creatinine increase ≥1.5× or ≥0.3 mg/dL from baseline persisting to day 30 or requiring renal replacement therapy. All-cause death and HF hospitalization rates between 30 days and 2 years were compared in patients with and without WRF. WRF at 30 days was present in 11.3% of patients (9.7% in the TEER plus GDMT group and 13.1% in the GDMT alone group; P=0.23). WRF was associated with all-cause death (hazard ratio [HR], 1.98 [95% CI, 1.3-3.03]; P=0.001) but not HF hospitalization (HR, 1.47 [ 95% CI, 0.97-2.24]; P=0.07) between 30 days and 2 years. Compared with GDMT alone, TEER reduced both death and HF hospitalization consistently in patients with and without WRF (Pinteraction=0.53 and 0.57, respectively). Conclusions Among patients with HF and severe secondary mitral regurgitation, the incidence of WRF at 30 days was not increased after TEER compared with GDMT alone. WRF was associated with greater 2-year mortality but did not attenuate the treatment benefits of TEER in reducing death and HF hospitalization compared with GDMT alone. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01626079.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Incidência , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Prognóstico , Rim/fisiologia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos
19.
J Am Heart Assoc ; 12(13): e029542, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37345820

RESUMO

Background Studies in mice and small patient subsets implicate metabolic dysfunction in cardiac remodeling in aortic stenosis, but no large comprehensive studies of human metabolism in aortic stenosis with long-term follow-up and characterization currently exist. Methods and Results Within a multicenter prospective cohort study, we used principal components analysis to summarize 12 echocardiographic measures of left ventricular structure and function pre-transcatheter aortic valve implantation in 519 subjects (derivation). We used least absolute shrinkage and selection operator regression across 221 metabolites to define metabolic signatures for each structural pattern and measured their relation to death and multimorbidity in the original cohort and up to 2 validation cohorts (N=543 for overall validation). In the derivation cohort (519 individuals; median age, 84 years, 45% women, 95% White individuals), we identified 3 axes of left ventricular remodeling, broadly specifying systolic function, diastolic function, and chamber volumes. Metabolite signatures of each axis specified both known and novel pathways in hypertrophy and cardiac dysfunction. Over a median of 3.1 years (205 deaths), a metabolite score for diastolic function was independently associated with post-transcatheter aortic valve implantation death (adjusted hazard ratio per 1 SD increase in score, 1.54 [95% CI, 1.25-1.90]; P<0.001), with similar effects in each validation cohort. This metabolite score of diastolic function was simultaneously associated with measures of multimorbidity, suggesting a metabolic link between cardiac and noncardiac state in aortic stenosis. Conclusions Metabolite profiles of cardiac structure identify individuals at high risk for death following transcatheter aortic valve implantation and concurrent multimorbidity. These results call for efforts to address potentially reversible metabolic biology associated with risk to optimize post-transcatheter aortic valve implantation recovery, rehabilitation, and survival.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Animais , Camundongos , Idoso de 80 Anos ou mais , Masculino , Multimorbidade , Estudos Prospectivos , Resultado do Tratamento , Valva Aórtica/cirurgia , Função Ventricular Esquerda
20.
JACC Cardiovasc Interv ; 16(12): 1448-1459, 2023 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-37380226

RESUMO

BACKGROUND: Little is known regarding the risk of cerebrovascular events (CVE) in patients with heart failure and severe secondary mitral regurgitation treated with transcatheter edge-to-edge repair (TEER). OBJECTIVES: The study sought to examine the incidence, predictors, timing, and prognostic impact of CVE (stroke or transient ischemic attack) in the COAPT (Cardiovascular Outcomes Assessment of the Mitraclip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) trial. METHODS: A total of 614 patients with heart failure and severe secondary mitral regurgitation were randomized to TEER plus guideline-directed medical therapy (GDMT) vs GDMT alone. RESULTS: At 4-year follow-up, 50 CVEs occurred in 48 (7.8%) of the 614 total patients enrolled in the COAPT trial; Kaplan-Meier event rates were 12.3% in the TEER group and 10.2 in the GDMT alone group (P = 0.91). Within 30 days of randomization, CVE occurred in 2 (0.7%) patients randomized to TEER and 0% randomized to GDMT (P = 0.15). Baseline renal dysfunction and diabetes were independently associated with increased risk of CVE, while baseline anticoagulation was associated with a reduction of CVE. A significant interaction was present between treatment group and anticoagulation such that TEER compared with GDMT alone was associated with a reduced risk of CVE among patients with anticoagulation (adjusted HR: 0.24; 95% CI: 0.08-0.73) compared with an increased risk of CVE in patients without anticoagulation (adjusted HR: 2.27; 95% CI: 1.08-4.81; Pinteraction = 0.001). CVE was an independent predictor of death within 30 days after the event (HR: 14.37; 95% CI: 7.61, 27.14; P < 0.0001). CONCLUSIONS: In the COAPT trial, the 4-year rate of CVE was similar after TEER or GDMT alone. CVE was strongly associated with mortality. Whether anticoagulation is effective at reducing CVE risk after TEER warrants further study. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [The COAPT Trial] and COAPT CAS [COAPT); NCT01626079).


Assuntos
Insuficiência Cardíaca , Ataque Isquêmico Transitório , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Anticoagulantes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...