Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Sci Rep ; 14(1): 5551, 2024 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448440

RESUMO

Patients with an implantable cardioverter-defibrillator (ICD) often report psychological distress. Literature suggests that patients with physical disease often compare their well-being and coping to fellow patients. However, we lack knowledge on social comparison among patients with ICD. In this study, we examined psychological distress and social comparison selection in patients with (ICD+) and without experienced ICD shocks (ICD-). We theorized that relative to ICD- patients, those with ICD+ display higher levels of psychological distress and thereby compare more frequently with fellow patients with more severe disease, but better disease coping and try to identify more strongly with these standards to improve their own coping. We recruited 92 patients with (ICD+, n = 38) and without an experienced ICD shock (ICD-, n = 54), who selected one of four comparison standards varying in disease severity and coping capacity. Relative to ICD-, ICD+ patients reported higher levels of device-related distress, but there were no significant differences in anxiety, depression, or quality of life. ICD+ patients selected more often comparison standards with poor coping and, irrespective of standard choice, displayed more negative mood following comparison. Our results show that ICD+ patients tend to perform unfavorable comparisons to fellow patients, which might explain higher psychological distress and worse coping. These findings warrant further research into social comparison as a relevant coping mechanism in ICD patients.


Assuntos
Desfibriladores Implantáveis , Choque , Humanos , Qualidade de Vida , Comparação Social , Afeto , Ansiedade
2.
Heart Rhythm ; 21(7): 1057-1063, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38382685

RESUMO

BACKGROUND: To assess the risk of unsuccessful conversion of ventricular fibrillation during defibrillation testing (DFT) with the subcutaneous implantable cardioverter-defibrillator (S-ICD), the PRAETORIAN score has been proposed. OBJECTIVE: The purpose of this study was to validate the PRAETORIAN score in a large S-ICD collective. METHODS: A retrospective single-center analysis of S-ICD patients receiving intraoperative DFT was performed. DFT was performed using a stepwise protocol with 65-J standard polarity, change of polarity, increase to 80 J, and repositioning if necessary. If all DFTs failed, we switched to a transvenous ICD. RESULTS: Overall, 398 patients were analyzed (268 male [67.3%]; mean age 42.4 ± 15.9 years; mean body mass index [BMI] 25.9 ± 4.8 kg/m2). Successful DFT with the first ICD shock was observed in 264 patients (66.3%). One hundred fourteen patients were defibrillated with the second (n = 104) or third (n = 10) DFT after changing shock polarity and/or shock energy. Overall, 20 patients needed at least 3 DFT (ie, 80 J and/or re-positioning). The majority (n = 88 [65.7%]) of DFT failures occurred before 2015 with the first-generation S-ICD. PRAETORIAN score was an independent predictor of DFT failure (odds ratio [OR] 1.007; 95% confidence interval [CI] 1.003-1.011 P ≤.001), while whereas BMI alone was not (P = .31). Presence of hypertrophic cardiomyopathy (HCM) (OR 2.6; 95% CI 1.3-4.4; P = .004) was predictive for at least 1 unsuccessful DFT in our multivariate regression analysis. CONCLUSION: PRAETORIAN score proved to be a useful and valid predictive tool for successful DFT, whereas BMI only had a limited role. Patients with HCM were at increased risk for DFT failure or needed higher DFT energy.


Assuntos
Desfibriladores Implantáveis , Fibrilação Ventricular , Humanos , Masculino , Estudos Retrospectivos , Feminino , Adulto , Fibrilação Ventricular/terapia , Pessoa de Meia-Idade , Medição de Risco/métodos , Cardioversão Elétrica/métodos , Cardioversão Elétrica/instrumentação , Morte Súbita Cardíaca/prevenção & controle , Seguimentos
3.
Clin Res Cardiol ; 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38112746

RESUMO

BACKGROUND: Cryoballoon ablation is a widely used single-shot technique for pulmonary vein isolation (PVI) in the treatment of paroxysmal atrial fibrillation (AF). Procedural endpoints ensuring maximal PVI durability are important. OBJECTIVE: To assess the performance of cryoablation procedural markers to predict long-term PVI. METHODS: In a single center, consecutive patients who underwent redo ablation with high-density mapping for symptomatic AF recurrence after cryoballoon ablation were included and cryoballoon procedural data were collected, including temperature values at 30 and 60 s, time to isolation, nadir temperature and the velocity of temperature decline estimated with the temperature/time catch-up point (T2T-Catch-Up) defined as positive when the freeze temperature in minus degree equals the time in seconds after cryoablation initiation (e.g. - 15 °C in the first 15 s of the ablation impulse). RESULTS: 47 patients (62% male; 58.3 ± 11.2 years) were included. Overall, 38 (80.9%) patients had ≥ 1 reconnected PV. Among 186 PVs, 56 (30.1%; 1.2 per patient on average) were reconnected. Univariate analysis revealed T2T-Catch-Up in 103 (56%) and more frequent in durably isolated than in reconnected PVs (93 [72%] vs 10 [19%], p < 0.0001). Among binary endpoints, T2T-Catch-Up had the highest specificity (82%) and predictive value for durable PVI at redo ablation (90%). In multivariable analyses, absence of T2T-Catch-Up (Odds-ratio 0.12, 95% CI [0.05-0.31], p < 0.0001) and right superior PV (Odds-ratio 3.14, 95% CI [1.27-7.74], p = 0.01) were the only variables independently associated with PV reconnection. CONCLUSION: T2T-Catch-Up, a new and simple cryoballoon procedural endpoint demonstrated excellent predictive value and strong statistical association with durable PVI.

5.
Clin Res Cardiol ; 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37902845

RESUMO

AIM: COVID-19 has been associated with cardiovascular complications including ventricular arrhythmias (VA) and an increased number of out-of-hospital cardiac arrests. Nevertheless, several authors described a decrease of VA burden in patients with an implantable defibrillator (ICD) during the first wave of the COVID-19 pandemic. The objective of this study was to determine if these observations could be transferred to later periods of the pandemic as well. METHODS: We retrospectively analyzed a total of 1674 patients with an ICD presenting in our outpatient clinic during the second wave of the COVID-19 pandemic and during a control period for the occurrence of VA requiring ICD interventions. RESULTS: Seven hundred ninety-five patients with an ICD had a device interrogation in our ambulatory clinic during the second wave of the COVID-19 pandemic compared to eight hundred seventy-nine patients in the control period. There was significant higher amount of adequate ICD therapies in the course of the COVID-19 period. Thirty-six patients (4.5%) received in total eighty-five appropriate ICD interventions during COVID-19, whereas only sixteen patients (1.8%) had sustained VA in the control period (p = 0.01). CONCLUSION: In contrast to the first wave of COVID-19, which was characterized by a decrease or least stable number of ICD therapies in several centers, we found a significant increase of VA in ICD patients during the second wave of COVID-19. Possible explanations for this observation include higher infectious rates, potential cardiac side effects of the vaccination as well as personal behavioral changes, or reduced utilization of medical services.

6.
Clin Res Cardiol ; 112(12): 1778-1789, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37162594

RESUMO

OBJECTIVE AND BACKGROUND: Catheter-based treatment of patients with ventricular arrhythmias (VA) reduces VA and mortality in selected patients. With regard to potential risks of catheter ablation, a benefit-risk assessment should be carried out. This can be performed with risk scores such as the recently published "Risk in Ventricular Ablation (RIVA) Score". We sought to validate this score and to test for possible additional predictors in a large database of VT ablations. METHODS AND RESULTS: We analyzed 1964 catheter ablations for VA in patients with (1069; 54.4%) and without (893, 45.6%) structural heart disease (SHD) and observed an overall major adverse event rate of 4.0% with an in-hospital mortality of 1.3% with significantly less complications occurring in patients without structural heart disease (6.5% vs. 1.1%; p ≤ 0.01). The RIVA Score demonstrated to be a valid predictive tool for major in-hospital complications (OR 1.18; 95% CI 1.12, 1.25; p ≤ 0.001). NYHA Class ≥ III (OR 2.5; 95% CI 1.5, 4.2; p < 0.001) and age (OR 1.04; 95% CI 1.02, 1.07; p ≤ 0.001) proved to be additional predictive parameters. Hence, a modified RIVA Score (mRIVA) model was analyzed with a subset of established predictors (SHD, eGFR, epicardial puncture) as well as new predictive parameters (age, NYHA Class ≥ III), that achieved a higher predictive value for major complications compared with the model based on all RIVA variables. CONCLUSION: Adding age and functional heart failure status (NYHA class) as simple clinical parameters to the recently published RIVA Score increases the predictive value for ablation-associated complications in a large VT ablations registry.


Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Cardiopatias/etiologia , Fatores de Risco , Hospitais , Ablação por Cateter/métodos , Resultado do Tratamento
7.
Clin Res Cardiol ; 112(12): 1748-1753, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36401623

RESUMO

BACKGROUND: Early repolarization pattern (ERP) has been associated with idiopathic ventricular fibrillation (IVF) and with cardiovascular mortality in the general population. As there is limited data about long- term outcome of IVF, the aim of our study was to observe ventricular arrhythmia (VA) recurrences in these patients and to identify a possible correlation of VA with ECG markers of early repolarization. METHODS AND RESULTS: We investigated 56 consecutive IVF patients who received an implantable cardioverter-defibrillator for secondary prevention. ERP was defined as a J-point elevation ≥ 0.1 mV in two or more contiguous inferior or lateral leads. Markers of early repolarization were present in 32.1% of cases with a preponderance of QRS slurring (77.8%). During a mean follow-up of 41.2 months, 11 patients (19.6%) received in total 18 adequate ICD-therapies. VF was most the common cause for ICDtherapy (61.1%) but monomorphic VT also occurred in four patients. Presence of ERP was associated with a significant trend towards arrhythmia recurrences. 38.9% patients with ERP received appropriate ICD-therapies whereas only 10.5% of patients without ERP had arrhythmia recurrence (p = 0.05). Inappropriate ICD-therapies occurred in seven patients (12.5%) with a non-significant trend towards a higher incidence in patients with a transvenous ICD (p = 0.15). CONCLUSION: A significant correlation between ERP and VA recurrences in patients with IVF could be observed. Though monomorphic VA also play a role in the studied IVF-population, our data support the use of the S-ICD in this collective.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Eletrocardiografia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia , Arritmias Cardíacas/etiologia , Coração , Desfibriladores Implantáveis/efeitos adversos
9.
J Clin Med ; 11(21)2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36362562

RESUMO

Background: Timing and mode of delivery in women with preeclampsia remains challenging, often balancing the risk of severe maternal complications and preterm delivery with its risks for the newborn. It is known that women with very high blood pressure levels in pregnancy have more unfavourable outcomes, but there is little data on neonatal outcome in these cases and the effect of the delivery mode. Methods: We included 158 preeclamptic women in our single-centre retrospective cohort study. Patients were divided into three subgroups depending on blood pressure levels, and delivery mode as well as neonatal outcomes were analysed. Furthermore, the effect of gestational age at delivery was assessed. Results: Maternal blood pressure levels correlated negatively with gestational age at delivery (p = 0.007) and positively with delivery via caesarean section (p = 0.003). Induction of labour was more frequent in women with lower blood pressure levels (p = 0.008) and higher gestational age (p < 0.001). If labour was induced, vaginal delivery was achieved equally often in all gestational ages. Neonatal outcome appears to be more favourable after vaginal delivery compared to planned caesarean section (p < 0.001). Conclusions: Induction of labour should be discussed generously in preeclamptic women, even if blood pressure levels are high and/or gestational age is young, as success rates seem to be adequate and neonatal outcome is more favourable after vaginal delivery. Large prospective trials are needed to better evaluate success rates, risks and complications of induced labour and the effects of delivery mode on neonatal outcome in preeclampsia.

10.
Pharmacology ; 107(11-12): 608-614, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36174497

RESUMO

INTRODUCTION: Hormone-mediated therapies are on the rise and are key therapies in the treatment of some of the most common cancer entities. Proarrhythmic effects have been described in patients treated with SERMs while little to none is known about the electrophysiological effects of the potentially less arrhythmogenic selective estrogen receptor degraders. METHODS: Twenty hearts of female New Zealand White rabbits were excised and retrogradely perfused employing a Langendorff setup. An electrophysiology study was performed to obtain CL-dependent action potential duration at 90% of repolarization (APD90), QT interval, effective refractory period (ERP), and post-repolarization refractoriness (PRR = ERP-APD90). After generating baseline data, the hearts were assigned to two groups and perfused with (n = 10) increasing doses of fulvestrant (1 µM and 5 µM; n = 10) or tamoxifen (2.5 µM and 7.5 µM; n = 10), and the protocol was repeated again. RESULTS: Fulvestrant led to a decrease in APD90 and QT interval and an increased PRR. The inducibility of ventricular tachycardia (VT) episodes was unaltered. Tamoxifen showed similar effects, resulting in a shortened APD90 and QT interval and no increased VT incidence in the setting of a prolonged PRR. CONCLUSION: The present study shows no acute proarrhythmic effect of tamoxifen and fulvestrant in an established whole heart model when employing clinically relevant concentrations.


Assuntos
Antiarrítmicos , Arritmias Cardíacas , Coelhos , Feminino , Animais , Antiarrítmicos/farmacologia , Fulvestranto/farmacologia , Fulvestranto/uso terapêutico , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/tratamento farmacológico , Coração , Potenciais de Ação , Tamoxifeno/farmacologia , Tamoxifeno/uso terapêutico
11.
Herzschrittmacherther Elektrophysiol ; 33(3): 290-296, 2022 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-35970909

RESUMO

Catheter-based ablation is nowadays a safe and widespread procedure for the treatment of cardiac arrhythmia. This requires exact anatomical knowledge both before and during the examination and is an important prerequisite for targeted treatment. At the beginning of the era of interventional catheter-based treatment, fluoroscopy was the only and usual means of visualization, whereas in the middle of the 1990s continuous 3D-mapping systems were developed for the non-fluoroscopic examination of patients. The correct use of these 3­D systems, which non-fluoroscopically visualize the catheter and mostly identify mechanisms of arrhythmia in great detail, nowadays makes an important contribution to successful interventional catheter treatment of arrhythmia; however, it is not uncommon for patients with ventricular arrhythmia to also carry implanted electronic devices, such as pacemakers, defibrillators or less frequently left ventricular hemodynamic support systems. All implantable devices lead to electromagnetic interferences, which can complicate the diagnostics and treatment during electrophysiological examinations and ablation. This article addresses the adversities and experiences associated with magnet-based 3D systems and implantable electromagnetically active cardiac devices.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Marca-Passo Artificial , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Fenômenos Eletromagnéticos , Humanos
12.
J Pers Med ; 12(8)2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-36013189

RESUMO

Background: Decision-making in primary prevention is not always trivial and many clinical scenarios are not reflected in current guidelines. To help evaluate a patient's individual risk, a new score to predict the benefit of an implantable defibrillator (ICD) for primary prevention, the MADIT-ICD benefit score, has recently been proposed. The score tries to predict occurrence of ventricular arrhythmias and non-arrhythmic death based on data from four previous MADIT trials. We aimed at examining its usefulness in a large single-center register of S-ICD patients with various underlying cardiomyopathies. Methods and results: All S-ICD patients with a primary preventive indication for ICD implantation from our large single-center database were included in the analysis (n = 173). During a follow-up of 1227 ± 978 days, 27 patients developed sustained ventricular arrhythmias, while 6 patients died for non-arrhythmic reasons. There was a significant correlation for patients with ischemic cardiomyopathy (ICM) (n = 29, p = 0.04) to the occurrence of ventricular arrhythmia. However, the occurrence of ventricular arrhythmias could not sufficiently be predicted by the MADIT-ICD VT/VF score (p = 0.3) in patients with (n = 142, p = 0.19) as well as patients without structural heart disease (n = 31, p = 0.88) and patients with LV-EF < 35%. Of the risk factors included in the risk score calculation, only non-sustained ventricular tachycardias were significantly associated with sustained ventricular arrhythmias (p = 0.02). Of note, non-arrhythmic death could effectively be predicted by the proposed non-arrhythmic mortality score as part of the benefit score (p = 0.001, r = 0.3) also mainly driven by ICM patients. Age, diabetes mellitus, and a BMI < 23 kg/m2 were key predictors of non-arrhythmic death implemented in the score. Conclusion: The MADIT-ICD benefit score adds a new option to evaluate expected benefit of ICD implantation for primary prevention. In a large S-ICD cohort of primary prevention, the value of the score was limited to patients with ischemic cardiomyopathy. Future research should evaluate the performance of the score in different subgroups and compare it to other risk scores to assess its value for daily clinical practice.

13.
J Cardiovasc Dev Dis ; 9(8)2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-36005421

RESUMO

The implantation of cardiac devices significantly reduces morbidity and mortality in patients with cardiac arrhythmias. Arrhythmias as well as therapy delivered by the device may impact quality of life of patients concerned considerably. Therefore we aimed at conducting a systematic search and meta-analysis of trials examining the impact of the implantation of cardiac devices, namely implantable cardioverter-defibrillators (ICD), pacemakers and left-ventricular assist devices (LVAD) on quality of life. After pre-registering the trial with the PROSPERO database, we searched Medline, PsycINFO, Web of Science and the Cochrane databases for relevant publications. Study quality was assessed by two independent reviewers using standardized protocols. A total of 37 trials met our inclusion criteria. Of these, 31 trials were cohort trials while 6 trials used a randomized controlled design. We found large pre-post effect sizes for positive associations between quality of life and all types of devices. The effect sizes for LVAD, pacemaker and ICD patients were g = 1.64, g = 1.32 and g = 0.64, respectively. There was a lack of trials examining the effect of implantation on quality of life relative to control conditions. Trials assessing quality of life in patients with cardiac devices are still scarce. Yet, the existing data suggest beneficial effects of cardiac devices on quality of life. We recommend that clinical trials on cardiac devices routinely assess quality of life or other parameters of psychological well-being as a decisive study endpoint. Furthermore, improvements in psychological well-being should influence decisions about implantations of cardiac devices and be part of patient education and may impact shared decision-making.

14.
J Cardiovasc Dev Dis ; 9(8)2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36005439

RESUMO

1. Introduction: Pulmonary vein isolation (PVI) is an established procedure used to achieve rhythm control in atrial fibrillation (AF). In obese patients (pts), in whom AF occurs more frequently, a reduced effectiveness of PVI has been observed. Therefore, this study's aim was to compare the long-term efficacy of PVI between obese and non-obese patients. 2. Methods: We enrolled 111 consecutive pts with a body mass index (BMI) of >30 kg/m2 undergoing PVI from our large registry. Procedural data and outcomes were compared with a matched group of 115 non-obese PVI pts and the long-term outcomes were analyzed. 3. Results: Overall follow-up duration was 314 patient-years in the obese and 378 patient-years in the non-obese group. The follow-up rate was 71% in the obese and 76% in the non-obese group. In both groups, their AF-characteristics did not differ significantly, while known risk factors were significantly more prevalent in the obese group. Procedural characteristics were similar in both groups. During follow-up, the obese pts demonstrated significant weight loss compared to the non-obese pts, while at the same time, the overall recurrence rate during follow-up did not differ significantly between both groups (obese: 39.2% and non-obese: 43.7%). PVI related and long-term complications were comparable between both groups. In the univariate analysis, obesity was not found to be associated with an increased AF recurrence risk. 4. Conclusion: These real-life data demonstrate that obese pts may not show higher AF recurrence rates after PVI compared to pts with normal body weight. Furthermore, PVI was found to be safe and effective in obese patients; thus, a BMI alone may not be a criterion for refusal of PVI.

15.
J Pers Med ; 12(7)2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35887632

RESUMO

INTRODUCTION: The long-QT syndrome (LQTS) is the most common ion channelopathy, typically presenting with a prolonged QT interval and clinical symptoms such as syncope or sudden cardiac death. Patients may present with a concealed phenotype making the diagnosis challenging. Correctly diagnosing at-risk patients is pivotal to starting early preventive treatment. OBJECTIVE: Identification of congenital and often concealed LQTS by utilizing novel deep learning network architectures, which are specifically designed for multichannel time series and therefore particularly suitable for ECG data. DESIGN AND RESULTS: A retrospective artificial intelligence (AI)-based analysis was performed using a 12-lead ECG of genetically confirmed LQTS (n = 124), including 41 patients with a concealed LQTS (33%), and validated against a control cohort (n = 161 of patients) without known LQTS or without QT-prolonging drug treatment but any other cardiovascular disease. The performance of a fully convolutional network (FCN) used in prior studies was compared with a different, novel convolutional neural network model (XceptionTime). We found that the XceptionTime model was able to achieve a higher balanced accuracy score (91.8%) than the associated FCN metric (83.6%), indicating improved prediction possibilities of novel AI architectures. The predictive accuracy prevailed independently of age and QTc parameters. CONCLUSIONS: In this study, the XceptionTime model outperformed the FCN model for LQTS patients with even better results than in prior studies. Even when a patient cohort with cardiovascular comorbidities is used. AI-based ECG analysis is a promising step for correct LQTS patient identification, especially if common diagnostic measures might be misleading.

16.
J Pers Med ; 12(8)2022 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-35893313

RESUMO

Syncopes are a very common phenomenon and have a high recurrence rate. The differentiation between the psychogenic and physical, especially of arrhythmic origin, remains difficult. In many cases, an implantable loop recorder is used for the detection of possible arrhythmias, leading to syncopes. Yet, the existing literature suggests that psychological factors may play a significant role in recurrent syncopes. We aimed at analyzing the potential role of several psychological factors on the recurrence of arrhythmic or non-arrhythmic syncopes. Methods and results: A total of 119 patients, who had received an implantable loop recorder for recurrent syncopes at our center between 01/2018 and 12/2021, participated in this retrospective cohort study. Anxiety, depression and quality of life were assessed using extensively validated questionnaires (GAD-7, PHQ-9 and SF-12). The mean follow-up after loop recorder implantation was 710 ± 430 days and 50% of patients were female. The mean patient age was 54.8 ± 18.6 years. Most patients had no evidence of structural heart disease (84%), and normal LV function (92%). A statistical analysis revealed that the presence of structural heart disease was the strongest predictor for arrhythmic syncope during follow-up. In patients with non-arrhythmic syncopes, we found significantly higher levels of anxiety (GAD-7 score: 2.5 ± 2.6 vs. 4.8 ± 4.3) and depression (PHQ-9 score: 3.9 ± 3.6 vs. 6.8 ± 5.1), and a lower quality of life (SF-12 score: 33.7 ± 6.4 vs. 29.6 ± 7.8). Discussion: We identified factors as contributors to a better identification of patients at risk for arrhythmic as well as non-arrhythmic syncopes. Especially anxious or depressive symptoms may hinted at non-arrhythmic causes of syncope. However, the study was limited by its retrospective design and low patient number. Further trials should likewise combine the diagnostic yield of loop recorders with psychometric evaluations before implantation and combine it with additional diagnostic measures, such as video monitoring, to further examine the role of psychological factors in the pathomechanism and treatment of syncope.

17.
Geburtshilfe Frauenheilkd ; 82(5): 528-534, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35528191

RESUMO

Introduction Patients with high blood pressure levels are at high risk for acute complications as well as serious long-term consequences. Women with preeclampsia often experience very high blood pressure levels during pregnancy and postpartum and are also known to have a higher cardiovascular risk in later life. Material and Methods In our single-centre retrospective cohort study, we analysed 158 pregnancies complicated by preeclampsia in regard to maternal outcome. We divided the patient cohort into three subgroups according to the blood pressure levels during hospital stay. Results Pre-existing arterial hypertension was significantly more common in patients with a hypertensive crisis (systolic blood pressure ≥ 180 mmHg and/or diastolic blood pressure ≥ 120 mmHg) during pregnancy than in patients with moderate or severe hypertension (p = 0.001). Women with a hypertensive crisis had an unfavourable outcome compared to women with lower blood pressure levels. These women developed a HELLP-syndrome significantly more often (p = 0.013). Moreover, most of the women with a hypertensive crisis during pregnancy were still hypertensive at hospital discharge (p = 0.004), even though they were administrated antihypertensive agents more often (p < 0.001) compared to women with lower blood pressure values. Conclusion Preeclamptic women with hypertensive crises should be identified quickly and monitored closely to avoid further complications. Standardized follow-up programs are lacking, but especially these patients seem to be at high risk for persistent hypertension and increased cardiovascular morbidity and therefore should receive specialist follow-up, including hypertensiologists, cardiologists and gynaecologists. Large prospective trials are required for a better understanding of these interrelations and to develop a specific follow-up program.

18.
Herzschrittmacherther Elektrophysiol ; 33(2): 161-174, 2022 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-35556156

RESUMO

As with all cardiac interventions, performing left ventricular ablation requires profound knowledge of cardiac anatomy. The aim of this article is to provide an overview of left ventricular anatomy and to characterize complex and clinically relevant structures from an electrophysiologist-centered perspective. In addition to the different access routes, the trabecular network, the left ventricular outflow tract, and the left ventricular conduction system, complex anatomical structures such as the aortomitral continuity and the left ventricular summit are also explained. In addition, this article offers multiple clinical examples that combine ECG, anatomy, and electrophysiologic study.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/cirurgia
19.
J Cardiol ; 80(4): 298-302, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35589465

RESUMO

INTRODUCTION: Recent studies suggest cardiac involvement with an increased incidence of arrhythmias in the setting of coronavirus disease 2019 (COVID-19). The aim of this study was to evaluate the risk of potentially lethal arrhythmias and atrial fibrillation in patients with COVID-19-induced acute respiratory distress syndrome (ARDS) and to elicit possible predictors of arrhythmia occurrence. METHODS AND RESULTS: A total of 107 patients (82 male, mean age 60 ±â€¯12 years, median body mass index 28 kg/m2) treated for COVID-19-induced ARDS in a large tertiary university hospital intensive care unit between March 2020 and February 2021 were retrospectively analyzed. Eighty-four patients (79%) had at least moderate ARDS, 88 patients (83%) were mechanically ventilated, 35 patients (33%) received vvECMO. Forty-three patients (40%) died during their hospital stay. Twelve patients (11%) showed potentially lethal arrhythmias (six ventricular tachycardia, six significant bradycardia). Atrial fibrillation occurred in 27 patients (25%). In a multivariate logistic regression analysis, duration of hospitalization was associated with the occurrence of potentially lethal arrhythmias (p = 0.006). There was no association between possible predictive factors and the occurrence of atrial fibrillation. Invasive ventilation, antipsychotics, and the QTc interval were independently associated with acute in-hospital mortality, but this was not arrhythmia-driven as there was no association between the occurrence of arrhythmias and mortality. CONCLUSION: In this relatively young population with COVID-19-induced ARDS, the incidence of potentially lethal arrhythmias was low. While overall mortality was high in these severely affected patients, cardiac involvement and arrhythmia occurrence was not a significant driver of mortality.


Assuntos
Fibrilação Atrial , COVID-19 , Síndrome do Desconforto Respiratório , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , COVID-19/complicações , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Síndrome do Desconforto Respiratório/epidemiologia , Síndrome do Desconforto Respiratório/etiologia , Estudos Retrospectivos
20.
J Cardiovasc Electrophysiol ; 33(6): 1290-1297, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35304782

RESUMO

BACKGROUND: Several case reports have suggested an increased risk of sudden cardiac death due to energy drinks. Therefore, the purpose of this study was to assess acute electrophysiologic effects of caffeine and taurine, two of the main ingredients of energy drinks, in an experimental whole-heart model. METHODS AND RESULTS: Twenty-five rabbit hearts were excised, retrogradely perfused, and assigned to two groups. Hearts were perfused with caffeine (2, 10, and 50 µM) or taurine (2, 10, and 50 µM) after generating baseline data. Eight monophasic action potentials and electrocardiography recordings showed a significant abbreviation of action potential duration (APD90 ), QT interval, and effective refractory periods (ERP) after caffeine treatment. With taurine, cardiac repolarization duration and ERP were significantly shortened. A ventricular vulnerability was assessed by a predefined pacing protocol. With caffeine, we observed a trend towards more ventricular arrhythmias in a dose-dependent manner. After treatment with taurine, significantly more episodes of ventricular arrhythmias occurred. CONCLUSION: In this experimental whole-heart study, treatment with caffeine and taurine provoked ventricular arrhythmias. The underlying mechanism was an abbreviation of cardiac repolarizations and effective refractory periods that may facilitate re-entry and thereby provokes arrhythmias. These findings help to understand the potentially hazardous and fatal outcomes after intoxication with energy drinks.


Assuntos
Doenças Cardiovasculares , Bebidas Energéticas , Potenciais de Ação , Animais , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/diagnóstico , Cafeína/efeitos adversos , Bebidas Energéticas/efeitos adversos , Fatores de Risco de Doenças Cardíacas , Humanos , Preparação de Coração Isolado , Coelhos , Fatores de Risco , Taurina/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...