Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Vasc Access ; : 11297298241282822, 2024 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-39402728

RESUMO

BACKGROUND: This study aimed to assess the safety and feasibility of a 3-month flushing interval for totally implantable venous access ports (TIVAPs), particularly regarding intraluminal clot formation. METHODS: Between May 2017 and September 2018, we established a single-center cohort of 151 patients who were referred for TIVAP removal and categorized them into three flushing-interval groups: A (⩽1 month), B (1-2 months), and C (2-3 months). Odds ratios (OR) with 95% confidence intervals (CI) were computed using logistic regression to determine the risk of intraluminal clot occurrence. To compare clot lengths among the groups, we employed linear regression. Restricted cubic splines were used to model the flushing interval as a continuous variable. RESULTS: Compared to Group A, Groups B and C had adjusted ORs of 0.82 (0.35-1.92) and 0.78 (0.29-2.11) for intraluminal clot risk. Occlusion was rare (1/151; 0.7%) and successfully treated with mechanical recanalization. Adjusted differences in clot length compared to Group A were 0.01 (-0.85 to 0.87) for Group B and -0.23 (-1.21 to 0.76) for Group C. Spline regression analysis showed no significant association between the flushing interval and clot length (p for trend = 0.84). CONCLUSION: The incidence and burden of intraluminal clots did not increase significantly within the first 3 months. Occlusion was rare, even in the presence of clots, and was successfully treated. Therefore, a 3-month flushing interval appears to be a safe and practical option, aligning with the common recommendation for surveillance intervals in patients with cancer.

2.
Hum Reprod Open ; 2024(3): hoae043, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39036364

RESUMO

STUDY QUESTION: What are the maternal and neonatal outcomes of second delivery in women who underwent uterine artery embolization (UAE) during their first delivery? SUMMARY ANSWER: Women who underwent UAE during their first delivery exhibited higher risks of placental problems, preterm births, and postpartum hemorrhage (PPH) in second delivery and the second offspring also showed increased risk of major congenital malformations, admission to the neonatal intensive care units (NICU), necrotizing enterocolitis, intraventricular hemorrhage, and bronchopulmonary dysplasia. WHAT IS KNOWN ALREADY: UAE is a minimally invasive procedure used as an alternative to hysterectomy for managing severe PPH. However, recent studies have raised concerns about potential obstetric complications, including recurrent PPH, placenta accreta spectrum (PAS), and fetal growth restriction in subsequent delivery following UAE. STUDY DESIGN SIZE DURATION: This was a nationwide retrospective cohort study using the Korean National Health Insurance Service (K-NHIS) database, covering 50 million individuals from 2004 to 2020. The cohort included 3 616 923 women with live births between 1 January 2005 and 31 December 2019 with follow-up data extending to 31 December 2020. PARTICIPANTS/MATERIALS SETTING METHODS: The study included women who had their first live birth between 2005 and 2019, excluding those who underwent hysterectomy (without UAE = 3 612 389, UAE = 4534). Among them, we selected women who had single gestation secondary delivery (without UAE = 1 694 600, UAE = 1146). Propensity score matching was used to control for confounding factors, resulting in 11 184 women without UAE and 1119 women with UAE for subsequent analysis. MAIN RESULTS AND THE ROLE OF CHANCE: Women in the UAE group had significantly higher risks of PAS (odds ratio (OR) = 38.91, 95% CI = 18.61-81.34), placenta previa (OR = 6.98, 95% CI = 5.57-8.75), and preterm birth (OR = 2.23, 95% CI = 1.71-2.90) during their second delivery. The risk of recurrent PPH was also significantly higher (OR = 8.94, 95% CI = 7.19-11.12). Their second offspring were more likely to have major congenital malformations (OR = 1.62, 95% CI = 1.25-2.11) and adverse neonatal outcomes, including NICU admissions (OR = 1.83, 95% CI = 1.48-2.25). Long-term outcomes showed a higher risk of attention-deficit/hyperactivity disorder (hazard ratio = 1.64, 95% CI = 1.03-2.63) but were otherwise comparable to those in the without UAE group. LIMITATIONS REASONS FOR CAUTION: Retrospective nature of the study may have introduced exposure and outcome misclassifications, despite the reliability of the K-NHIS database. Unmeasured confounders and selection bias due to only including live births could also have influenced the results. WIDER IMPLICATIONS OF THE FINDINGS: Women with a history of UAE require meticulous prenatal care and close monitoring during subsequent deliveries due to increased risks of complications. Counseling and referral to high-risk medical centers may improve outcomes. Further research is needed to understand the mechanisms of complications in both mothers and offspring at sequential delivery, as well as to refine UAE procedures. STUDY FUNDING/COMPETING INTERESTS: This study supported by Patient-Centered Clinical Research Coordinating Center (PACEN) funded by the Ministry of Health & Welfare, Republic of Korea (HC21C0123). This study was funded by S.-Y.O. The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article. TRIAL REGISTRATION NUMBER: N/A.

3.
Hemodial Int ; 28(2): 162-169, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38481062

RESUMO

PURPOSE: To evaluate the efficacy and outcome of the transjugular approach in endovascular recanalization of a thrombosed straight arteriovenous graft (AVG) compared to those of the direct hemodialysis access approach (conventional approach). MATERIALS AND METHODS: We retrospectively assessed patients who underwent aspiration thrombectomy and percutaneous transluminal angioplasty for thrombosed straight AVG performed at a single institution between October 2006 and October 2021. A total of 138 thrombosed AVGs in 83 patients (39 male and 44 females) were divided into the transjugular approach group (Group A) and the conventional approach group (Group B). Technical and clinical success, postintervention primary patency, cumulative patency, and periprocedural complications were compared. RESULTS: There was no statistical difference in demographic data between groups A and B. The technical success rate of group A and B was 96.4% (80/83) and 98.2% 54/55, respectively (p > 0.05). The mean procedure time was 61.4 min (Group A) and 70.5 min (Group B) (p > 0.05). There was no statistically significant difference between the two groups in postintervention primary patency. The cumulative patency of Groups A and B was 911.9 days (range 122-6277) and 1062.3 days (range 72-2302 days), respectively (p > 0.05). One patient in Group B experienced a major graft rupture. Pseudoaneurysm formation at the sheath insertion site occurred in two patients in Group B. No cases of stenosis or thrombosis of the IJV or hematoma at the puncture site were observed in Group A. CONCLUSION: The transjugular approach is as safe and effective as the conventional approach for aspiration thrombectomy and percutaneous transluminal angioplasty of thrombosed straight AVGs.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica , Trombose , Feminino , Humanos , Masculino , Estudos Retrospectivos , Grau de Desobstrução Vascular , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Diálise Renal/métodos , Trombose/etiologia , Trombose/cirurgia , Trombectomia/métodos , Angioplastia/efeitos adversos , Resultado do Tratamento , Oclusão de Enxerto Vascular/cirurgia , Oclusão de Enxerto Vascular/complicações , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos
4.
J Korean Soc Radiol ; 85(1): 161-170, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38362390

RESUMO

Purpose: To assess the safety and feasibility of intentionally positioning the catheter tip in the right atrium (RA) without an abutment during implantation of a totally implantable venous access port (TIVAP). Materials and Methods: We enrolled 330 patients who had undergone TIVAP implantation between January and December 2016 and postoperative chest CT. The TIVAP was placed using the single-incision technique to access the axillary vein directly from the incision line. To position the catheter tip in the RA without abutment, blood return was checked before cutting. Catheter length and complications were evaluated by retrospectively reviewing medical images and records. Results: All patients achieved successful catheter tip positioning without abutment or dysfunction. The median tip position was 15.3 mm distal to the cavoatrial junction (CAJ) on fluoroscopy and 6 mm distal to the CAJ on CT. Catheter tips migrated a median of 10.4 mm cephalically on CT compared to fluoroscopy. Thromboses were detected in the RA and superior vena cava in one patient each. Conclusion: Intentional catheter tip positioning in the RA without abutment is a safe and feasible technique with a low incidence of thrombosis and no observed dysfunction.

5.
J Vasc Access ; 24(3): 430-435, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-34387524

RESUMO

PURPOSE: To evaluate if the mechanical injection of saline is effective in restoring patency of a totally implantable venous access port (TIVAP) with an intraluminal occlusion. MATERIALS AND METHODS: From January 2017 to June 2019, 64 cases of dysfunction of a TIVAP were referred to interventional radiology. Among these, 16 cases showed normal function of the TIVAP, 19 cases the showed the appearance of a fibroblastic sheath, and 29 cases showed intraluminal occlusion. Mechanical recanalization was performed for intraluminal occlusion of the TIVAP with an indeflator and a 20G non-coring needle. Linograms were performed in all recanalized cases. The success or failure of recanalization and the pressure of the indeflator were recorded. Linograms were evaluated for breakage or migration of catheters. Medical records were retrospectively reviewed. RESULTS: Among the 29 intraluminal occlusion cases, 24 cases (82.7%) were recanalized by mechanical recanalization via an indeflator. The pressure of the indeflator ranged from 29 to 220 psi (median: 118 psi). Linograms revealed breakage of the catheter of the TIVAP in two failed cases. The median interval from implantation to dysfunction was 405 days (range: 43-1723 days). The median interval from last use to dysfunction was 8 days (mean: 15.4 days; range: 1-119 days). The median re-occlusion free period after successful mechanical recanalization was 100.5 days (range: 6-859 days). CONCLUSION: In the absence of an available thrombolytic agent, mechanical injection of saline was a tolerable alternative method for restoring occluded catheters and sustaining the function of catheters. Because breakage of the catheter can occur during mechanical recanalization of a TIVAP, a linogram should follow the procedure.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Humanos , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora , Estudos Retrospectivos
6.
Gut Liver ; 16(6): 976-984, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-35466091

RESUMO

Background/Aims: We studied the impact of socioeconomic status (SES) on mortality in hepatocellular carcinoma patients and analyzed the effect of SES on initial treatment allocation. Methods: A cohort study was conducted using data from the National Health Insurance Service- National Sample Cohort of Korea. A total of 3,032 hepatocellular carcinoma patients who were newly diagnosed between January 2003 and December 2013 were included. Income level was categorized as Medical Aid and ≤30th, 31st-70th, or >70th percentile as an SES indicator. Results: The proportion of Medical Aid was 4.3%. The highest risks of all-cause mortality associated with Medical Aid were evident in the transcatheter arterial chemoembolization group (fully adjusted hazard ratio [HR], 2.40; 95% confidence interval [CI], 1.25 to 4.58), the other treatments group (fully adjusted HR, 2.86; 95% CI, 1.85 to 4.41), and the no treatment group (fully adjusted HR, 2.69; 95% CI, 1.79 to 4.04) but not in the curative treatment group. An association between the lower-income percentile and higher liver cancer-specific mortality was also observed, except in the curative treatment group. The association between income percentile and all-cause mortality was nonlinear, with a stronger association in the lower-income percentiles than in the higher income percentiles (p-value for nonlinear spline terms <0.05). Conclusions: Patients in the lower SES group, especially patients not eligible for curative treatment, had an increased risk of mortality. In addition, the association between SES and the risk for mortality was stronger in the lower-income percentile than in the moderate to higher income percentiles.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/terapia , Estudos de Coortes , Neoplasias Hepáticas/terapia , Classe Social
7.
Acta Radiol ; 63(1): 48-58, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33356351

RESUMO

BACKGROUND: The inferior phrenic artery (IPA) is the most common extrahepatic feeder for hepatocellular carcinoma (HCC) during transhepatic arterial chemoembolization (TACE). PURPOSE: To compare the incidence of diaphragmatic weakness in patients with HCC after TACE of the right IPA conducted using either N-butyl cyanoacrylate (NBCA) or gelatin sponge particles. MATERIAL AND METHODS: Medical records of 111 patients who underwent TACE of the right IPA using NBCA were retrospectively reviewed and compared with data from 135 patients with IPA embolization using gelatin sponge particles. RESULTS: The incidence of diaphragmatic weakness after the initial TACE procedure did not significantly differ between the groups (NBCA group 16.2%; gelatin sponge group 20.7%; P = 0.458). Five patients in the NBCA group and 11 in the gelatin sponge group showed spontaneous resolution of diaphragmatic weakness after a mean period of 3.5 months. Diaphragmatic weakness developed after the initial follow-up visit in 17 patients from the gelatin sponge group due to repeated TACE of the right IPA (mean 2.4 sessions; range 2-4 sessions), while it spontaneously developed without additional TACE procedures in one patient from the NBCA group. Permanent diaphragmatic weakness was less common in the NBCA than in the gelatin sponge group (12.6% and 25.2%, respectively; P = 0.017). The complete response rate did not significantly differ between the groups (NBCA group 16.2%; gelatin sponge group 25.9%; P = 0.065). CONCLUSION: Use of NBCA rather than gelatin sponge particles for TACE of the right IPA resulted in a lower incidence of permanent diaphragmatic weakness.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/efeitos adversos , Diafragma/irrigação sanguínea , Diafragma/fisiopatologia , Embucrilato/efeitos adversos , Esponja de Gelatina Absorvível/efeitos adversos , Neoplasias Hepáticas/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
8.
Minim Invasive Ther Allied Technol ; 31(2): 197-205, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32678715

RESUMO

BACKGROUND: Arterioureteral fistula (AUF) is a condition resulting from the pathologic connection between the ureter and the artery. Despite the low incidence, it can lead to devastating clinical consequences due to massive hematuria with a considerable mortality rate. MATERIAL AND METHODS: From January 2009 to December 2018, eight patients with AUF from two tertiary referral centers were included. Clinical data including presenting symptoms, previous pelvic surgery or radiotherapy, indwelling ureteral stents, primary vascular pathology, angiographic findings, type of treatment, survival, and recurrence were analyzed. RESULTS: All eight patients (six women, mean age 62.4 ± 14.5 years) presented with macroscopic hematuria and were successfully treated by endovascular management. One patient developed AUF due to an underlying iliac artery aneurysm, and the rest were due to secondary causes. Six patients had a history of an indwelling ureteral stent for a median of 5.5 months (1-84 months). All of the patients were successfully treated by endovascular management. For the median follow up of 987 days, three patients had recurrence of hematuria in a mean of 6.3 months, two patients were treated by surgery, while one was treated by endovascular treatment. CONCLUSION: AUF should be confirmed through a purposeful iliac angiogram or ureterography when suspected based on a relevant history or CT findings. AUF can be successfully treated by endovascular management. The surgical option should be considered in cases of recurrence. ABBREVIATIONS: AUF: arterioureteral fistula; CIA: common iliac artery; DJ: double J; EIA: external iliac artery; IIA: internal iliac artery; NBCA: N-butyl cyanoacrylate; PCN: percutaneous nephrostomy.


Assuntos
Procedimentos Endovasculares , Doenças Ureterais , Fístula Urinária , Fístula Vascular , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Resultado do Tratamento , Doenças Ureterais/terapia , Fístula Urinária/diagnóstico por imagem , Fístula Urinária/etiologia , Fístula Urinária/cirurgia , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/terapia
10.
Sci Rep ; 11(1): 10234, 2021 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-33986427

RESUMO

The purpose of this study is to investigate strategies for peripherally inserted central catheter (PICC) placement in patients with venous steno-occlusive lesion (VSOL). We performed a retrospective cohort study in adults with central or peripheral VSOL who underwent PICC placement procedures from January 2015 to December 2018. Four different strategies [selecting alternative pathway/over the wire (SAP/OTW), percutaneous transluminal angioplasty (PTA), re-puncture in ipsilateral arm (RIA), and catheter placement in the contralateral arm (CICA)] were analyzed and we compared the clinical outcomes by strategy and compared the strategy between central and peripheral VSOLs. During 4 years, 258 PICC procedures performed in patients with VSOLs, 100 PICC were included in the analysis. The overall technical success rate of initial attempt with SAP/OTW was 32.2%. As a second-line technique, PTA was most frequently used in both central (100%) and peripheral (68.2%) VSOL groups. The clinical success rates within 2 months of SAP/OTW, PTA, RIA, CICA were 55.2%, 43.2%, 14.3%, and 33.3%, respectively (P = 0.24). In conclusion, when the SAP/OTW failed, the PTA can be preferred as a second-line technique for both central and peripheral VSOLs. When guidewire passage fails, the operator could adopt the RIA or CICA technique as an alternative method.


Assuntos
Cateterismo Venoso Central/métodos , Cateterismo Periférico/métodos , Cateteres Venosos Centrais/tendências , Adulto , Idoso , Cateteres Venosos Centrais/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Doenças Vasculares
11.
J Vasc Interv Radiol ; 31(4): 576-583, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31530489

RESUMO

PURPOSE: To report the efficacy of rectal artery embolization (RAE) for the treatment of rectal bleeding and the prognostic factors related to recurrent bleeding. MATERIALS AND METHODS: A total of 34 patients in a single center who underwent RAE for treatment of rectal bleeding between September 1998 and December 2018 were retrospectively reviewed. Procedure details including angiographic findings and embolic materials used, technical success rate, bleeding control rate during hospital stay, major adverse event rate, and prognostic factors associated with recurrent bleeding were evaluated. RESULTS: Technical success rate was 97.1% (33 of 34). Bleeding control during hospital stay was achieved in 64.7% of patients (n = 22). The most common bleeding focus was in the superior rectal artery. Recurrent bleeding occurred in 11 patients. Incomplete initial angiography with only an inferior mesenteric or internal iliac angiogram had been performed in 90.9% of patients with recurrent bleeding (10 of 11) and 52.2% of patients with bleeding control (12 of 23; P = .053). The use of N-butyl-2-cyanoacrylate was related to a significantly lower incidence of recurrent bleeding (P = .014), whereas coagulopathy (P = .001) and transfusion of > 10 U of packed red blood cells (PRBCs; P = .003) were related to higher recurrent bleeding rates. One patient had a puncture site-related complication, and no bowel infarction was noted during follow-up. CONCLUSIONS: RAE was feasible and safe. The use of N-butyl-2-cyanoacrylate, presence of coagulopathy, and transfusion of > 10 U of PRBCs were significant factors related to recurrent bleeding. Bilateral inferior mesenteric artery and internal iliac artery angiography is highly recommended in the initial RAE session to achieve a high rate of bleeding control.


Assuntos
Embolização Terapêutica , Embucrilato/administração & dosagem , Hemorragia Gastrointestinal/terapia , Reto/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Embolização Terapêutica/efeitos adversos , Embucrilato/efeitos adversos , Transfusão de Eritrócitos , Feminino , Hemorragia Gastrointestinal/diagnóstico por imagem , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
12.
J Vasc Interv Radiol ; 31(1): 155-161, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31420261

RESUMO

Although a snare is the commonly used device for antegrade double J (DJ) stent removal, there are some cases in which DJ stent removal using only a snare is particularly difficult. In the present study, an unfavorable positioning of the proximal DJ stent tip and tip embeddedness were significantly associated with a simple snare technique failure; thus, present the modified snare technique to overcome the simple snare technique failure. By applying these 2 techniques together, we can increase the overall technical success rate up to 97% (196/202). The modified snare technique is safe and effective in cases of simple snare technique failure.


Assuntos
Remoção de Dispositivo/métodos , Stents , Ureter , Obstrução Ureteral/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Ureter/diagnóstico por imagem , Obstrução Ureteral/diagnóstico por imagem , Obstrução Ureteral/etiologia , Adulto Jovem
13.
Cardiovasc Intervent Radiol ; 42(6): 873-879, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30919025

RESUMO

PURPOSE: To retrospectively evaluate the short-term outcomes of lymphangiography and lymphatic embolization in the treatment of pelvic lymphocele after radical prostatectomy in patients with prostate cancer. MATERIALS AND METHODS: The data of nine, consecutive patients who underwent lymphangiography and lymphatic embolization for pelvic lymphocele after radical prostatectomy with pelvic lymph node dissection (PLND) between January 2016 and May 2018, were retrospectively reviewed. Lymphangiography was performed through inguinal lymph nodes in order to identify the lymphatic leakage. When a leakage was found, lymphatic embolization was performed using a directly punctured fine needle at the closest upstream lymph node or lymphopseudoaneurysm and with N-butyl cyanoacrylate glue. RESULTS: Lymphangiography demonstrated extravasation and/or lymphopseudoaneurysm in all of these patients. A total of 13 sessions of lymphangiography and lymphatic embolization were performed. The median number of lymphangiography and lymphatic embolizations required to achieve clinical success was one (range, 1-3). Three patients underwent repeated embolization with successful results. The technical and clinical success rates were 100%, respectively. The median time to resolution was 7 days (range, 2-19 days). There was no recurrence and no procedure-related complications during the follow-up period (mean, 26 weeks; range, 8-77 weeks) in all patients. CONCLUSIONS: Lymphangiography and lymphatic embolization are safe and effective for the management of pelvic lymphoceles after radical prostatectomy with PLND.


Assuntos
Embolização Terapêutica/métodos , Doenças Linfáticas/terapia , Linfocele/terapia , Linfografia/métodos , Complicações Pós-Operatórias/terapia , Prostatectomia/efeitos adversos , Neoplasias da Próstata/cirurgia , Idoso , Embucrilato , Humanos , Excisão de Linfonodo/métodos , Doenças Linfáticas/diagnóstico por imagem , Doenças Linfáticas/etiologia , Vasos Linfáticos/diagnóstico por imagem , Linfocele/diagnóstico por imagem , Linfocele/etiologia , Masculino , Pessoa de Meia-Idade , Pelve , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...