Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Eur J Pediatr ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38771374

RESUMO

To determine the diaphragm thickness, thickening fraction, and excursion and thickness of the quadriceps femoris muscle in full-term newborns and to evaluate the intra- and interrater reliability of these measurements. This was a prospective, observational clinical study including full-term newborns born within the first 48 h after birth. Serial measurements of the thickness, thickening fraction, and mobility of the diaphragm muscles and the thickness of the quadriceps muscle were obtained using ultrasound images. A total of 69 newborns with a mean gestational age of 39 weeks were included. The following measurements were obtained and are expressed as the mean (standard deviation): inspiratory diaphragm thickness, 0.19 cm (0.04); expiratory diaphragm thickness, 0.16 cm (0.04); diaphragm thickness fraction, 16.70 cm (10.27); diaphragmatic excursion, 0.68 cm (0.22); and quadriceps thickness, 0.99 cm (0.14). Intrarater reliability was assessed using intraclass correlation coefficients (ICCs). Excellent intrarater agreement was observed for the two groups of operators (ICC > 0.86, p < 0.001) for all measurements except for the diaphragm thickening fraction, which showed good agreement for both operator groups (ICC = 0.70, p < 0.001). Regarding interrater reliability, moderate agreement between the raters was observed in the means of all measures (ICC > 0.49, p < 0.001), except for the diaphragm thickening fraction, which showed poor agreement.    Conclusion: Good intrarater and moderate interrater reliability were achieved in ultrasound evaluations of the thickness and mobility of the diaphragm and quadriceps femoris muscles in full-term newborns, demonstrating the feasibility of this technique for clinical use. This pioneering study offers reference values for these muscles in a single study, allowing comparisons between different clinical conditions. What is Known: • Ultrasound is a highly reliable tool for muscle assessment that can be used to assess muscular atrophy in critically ill patients. • Muscle atrophy worsens the patient's condition and has been associated with worse outcomes. What is New: • To our knowledge, this is the first study to jointly evaluate the diaphragm and quadriceps muscle thickness and evaluate the reliability of all measurements. • Our study presents reference values for both muscles, enabling comparisons between different clinical conditions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...